Загрузил Виктор Прошкин

VRS1 Programming Manual 2.0

реклама
PP – V 401 Elektroplanung und -anlagenbau
VRS1
Programming manual
Team leader
Software
Hardware
E-Plan
Sensor technology
Programming
Fax:
Mail:
Version: 2.0 Date: 08.03.02
Contact partner:
Reinhardt Mielke
Dieter Niehues
Maik König
Peter Lammert
Manfred Borgwardt
Michael Mischke
Peter Traichel
Rene Smolka
Telefon:
05361 9 27870
05361 9 29272
05361 9 29272
05361 9 29272
05361 9 20092
05361 9 29272
05361 9 70405
05361 9 78065
05361 9 25805
forename.surname@volkswagen.de
VRS 1
TABLE OF CONTENTS
0
INITIAL HELP
1
STOPPED WHEN ACTUATOR OFF/ON
2
PROGRAMMING CONVENTIONS
3
HAND CONSOLE (TEACH BOX)
4
COMMISSIONING
5
HAND OPERATION
6
PROGRAMMING SEQUENCES
7
PROGRAM EDITING
8
PLC PROGRAMMING
9
SINGLE STEP
10
AUTOMATIC
11
SERVICE PROGRAM
12
TESTS
13
MODIFY CONSTANTS
14
AUXILIARY MODUL
15
OPERATING SYSTEM VERSION 2.0 issued
08.01.2002
Page:0-2
Elektroplanung-und Anlagenbau
08.03.02
VRS 1
0. Table of contents
1. Table of contents
1.
Initial help ............................................................................................. 1-1
Teaching with the wrong tool ....................................................................... 1-3
Remedy: ......................................................................................................... 1-3
Implementation: ............................................................................................. 1-3
Correcting all sequences and sub-programs.............................................. 1-3
The tool dimensions have been changed.................................................... 1-5
Remedy: ......................................................................................................... 1-5
Implementation: ............................................................................................. 1-5
Problems after updating to version 1.13 ..................................................... 1-7
Spot welding robot ........................................................................................ 1-7
Increasing the cycle time .............................................................................. 1-7
2. Stopped when actuator OFF/ON
2.
Stopped when actuator OFF/ON......................................................... 2-1
3. Programming conventions
3.
Programming conventions ................................................................. 3-1
General information....................................................................................... 3-3
Conventions for setting up the program sequences.................................. 3-4
Guide to operating robots using VRS1........................................................ 3-7
Preface: .......................................................................................................... 3-7
Commissioning.............................................................................................. 3-7
Setting up the robot sequences ................................................................... 3-8
Specifications for point inputs ..................................................................... 3-9
Jobs using PVC and epoxy-hard adhesive ............................................... 3-10
Re-welding using VRS 1 robots ................................................................. 3-12
PLC programming ....................................................................................... 3-13
Interlocking .................................................................................................. 3-13
Prior to transferring to production............................................................. 3-14
Changing the operating system version ................................................... 3-14
4. Hand console (teach box)
4.
Hand console (teach box) ................................................................... 4-1
The hand console (teach box) ...................................................................... 4-3
Hand console display.................................................................................... 4-4
Function keys F1 - F5 .................................................................................... 4-5
Hand console keys ........................................................................................ 4-6
Joystick-key ................................................................................................... 4-6
Joystick-key with single traversing keys .................................................... 4-6
Co-ordinates system-key .............................................................................. 4-7
New start-key ................................................................................................. 4-7
Cursor-keys.................................................................................................... 4-8
Clear-key ........................................................................................................ 4-8
Abort-key........................................................................................................ 4-8
Return-key...................................................................................................... 4-8
Axis-traversing keys 1V - 6V 1R - 6R ........................................................ 4-8
Shift-key ......................................................................................................... 4-9
08.03.02
Elektroplanung-und Anlagenbau
Page:0-3
VRS 1
+/– Keys .......................................................................................................... 4-9
Decimal-keys.................................................................................................. 4-9
Pre-selecting the gripper-No. ....................................................................... 4-9
Gripper OPEN, gripper CLOSED .................................................................. 4-9
Drive system ON / OFF keys....................................................................... 4-10
Operating mode selection keys.................................................................. 4-10
Confirmation key ......................................................................................... 4-11
Joystick (optional)....................................................................................... 4-12
5. Commissioning
5.
Commissioning.................................................................................... 5-1
Error clearing procedures............................................................................. 5-4
Checking the robot model ............................................................................ 5-5
Changing the robot model ............................................................................ 5-7
Checking drive system ON ........................................................................... 5-8
Commissioning the robots ........................................................................... 5-9
Checking the robot operating and traversing ranges .............................. 5-10
Checking the maximum operating range .................................................. 5-10
Checking the standardised position.......................................................... 5-11
Commissioning the additional axes .......................................................... 5-11
Constant 201 ................................................................................................ 5-12
Constant 209 ................................................................................................ 5-12
Constant 207 ................................................................................................ 5-12
Constant 204 ................................................................................................ 5-12
Constant 202 ................................................................................................ 5-13
Constants 205+206 ...................................................................................... 5-13
Constant 103 ................................................................................................ 5-13
Constant 102 ................................................................................................ 5-13
Constant 108 ................................................................................................ 5-14
Constants 106 ... 111 ................................................................................... 5-14
Tools ............................................................................................................. 5-15
Selecting tools for teaching........................................................................ 5-16
Entering the tool measurements (TCP) ..................................................... 5-17
Tool assignments ........................................................................................ 5-17
Automatic tool measuring .......................................................................... 5-17
Gripper.......................................................................................................... 5-18
Assigning the gripper-No. and the gripper models .................................. 5-18
6. Hand operation
6.
Hand operation .................................................................................... 6-1
The Hand Operating Mode ............................................................................ 6-3
Operating in the Hand operating mode ....................................................... 6-4
Traversing individual axes............................................................................ 6-5
Traversing the additional axes ..................................................................... 6-6
Cartesian traversing ...................................................................................... 6-6
Selecting the traversing ................................................................................ 6-7
Cartesian movement in BAS0WA global co-ordinates system ................. 6-8
Cartesian movement in BAS1WA basic co-ordination system ................. 6-9
Cartesian movement in HEADWA head co-ordination system.................. 6-9
Rotating the tool tip (TCP) SWVLWA (PIVOWA) ....................................... 6-10
Incremental traversing ................................................................................ 6-11
Page:0-4
Elektroplanung-und Anlagenbau
08.03.02
VRS 1
Traversing velocity in hand mode.............................................................. 6-12
Gripper functions ........................................................................................ 6-13
Pre-selecting the gripper-No. ..................................................................... 6-13
Gripper functions [Gripper OPEN] and [Gripper CLOSED]...................... 6-13
Releasing the gripper function through a permanent signal................... 6-14
Gripper text editor ....................................................................................... 6-16
Linking out the protection lattices ............................................................. 6-17
7. Programming sequences
7.
Programming sequences .................................................................... 7-1
The "Teaching" function ............................................................................... 7-3
New teaching ................................................................................................. 7-3
Editing ............................................................................................................ 7-3
Inserting ......................................................................................................... 7-3
Delete.............................................................................................................. 7-3
New teaching ................................................................................................. 7-4
Setting up a TCP............................................................................................ 7-5
Setting up a sequence................................................................................... 7-6
Entering a sequence-No................................................................................ 7-7
TCP teaching (point-No. 0)............................................................................ 7-8
Entering additional information ................................................................... 7-9
Teaching of other TCP's ............................................................................. 7-11
Finalising a sequence ................................................................................. 7-12
Interpolation methods ................................................................................. 7-13
PTP interpolation......................................................................................... 7-15
Linear interpolation ..................................................................................... 7-16
Swivel interpolation..................................................................................... 7-17
Circular interpolation .................................................................................. 7-18
Spline interpolation ..................................................................................... 7-20
MPG - interpolation...................................................................................... 7-21
Velocity profile............................................................................................. 7-22
Trajectory velocity Vb ................................................................................. 7-23
End velocity Ve ............................................................................................ 7-24
Start acceleration Aa ................................................................................... 7-25
End acceleration -Ae ................................................................................... 7-25
Filter (jerk) .................................................................................................... 7-26
Velocity profile for PTP ............................................................................... 7-29
Accuracy ...................................................................................................... 7-30
Accuracy of PTP points .............................................................................. 7-30
Accuracy of trajectory points ..................................................................... 7-31
Controlled corner creep .............................................................................. 7-33
Automatic reduction of the accuracy radius and the point end velocity 7-34
Weaving........................................................................................................ 7-36
Sensor functions ......................................................................................... 7-39
Commentary................................................................................................. 7-42
Search run.................................................................................................... 7-43
Co-ordinates display ................................................................................... 7-46
Modifying the displayed difference co-ordinates: .................................... 7-52
Setting up a sub-program ........................................................................... 7-53
Calling up a sub-program ........................................................................... 7-53
Example of an operating sequence with sub-program branching: ......... 7-54
08.03.02
Elektroplanung-und Anlagenbau
Page:0-5
VRS 1
Programming sub-programs ...................................................................... 7-54
Finalising sub-programs............................................................................. 7-55
Calling up a sub-program ........................................................................... 7-55
Sequences and sub-program overview ..................................................... 7-56
8. Program editing
8.
Program editing ................................................................................... 8-1
Correcting ...................................................................................................... 8-3
Correcting individual TCP's.......................................................................... 8-4
Correcting the PLC instructions .................................................................. 8-5
Correcting the co-ordinates.......................................................................... 8-5
Editing the co-ordinates................................................................................ 8-7
Correcting the interpolation method ........................................................... 8-8
Calling the next / previous point for correction ........................................ 8-10
Correcting additional information.............................................................. 8-10
Correcting the tool No................................................................................. 8-11
Correcting the kinematic No....................................................................... 8-11
Correcting the weave parameters .............................................................. 8-11
Correcting the sensor functions ................................................................ 8-13
Correcting the commentaries..................................................................... 8-14
Correcting the search run parameters....................................................... 8-14
Correcting the complete program.............................................................. 8-16
Complete program: Geometry.................................................................... 8-17
Point translation according to angles....................................................... 8-17
Carrying out the correction (shifting the joining angle)........................... 8-20
Cartesian point shifting............................................................................... 8-21
Example of a head or basic co-ordinates cartesian program shift ......... 8-22
EULER cartesian shift ................................................................................. 8-23
Example of a head co-ord. cartesian program shift using Euler-angles 8-23
Example of a head co-ord. cartesian program shift using RPY-angles .. 8-23
Program mirroring ....................................................................................... 8-25
Tool symmetry for program mirroring ....................................................... 8-29
Program transformation.............................................................................. 8-31
Mirroring and transformation ..................................................................... 8-35
Complete program: additional information ............................................... 8-36
PLC instruction programming corrections ............................................... 8-38
Traversing parameter programming corrections ..................................... 8-39
Interpolation method programming corrections ...................................... 8-40
Weaving parameter programming corrections ......................................... 8-40
Programming Tool No. corrections ........................................................... 8-41
Editing program names............................................................................... 8-41
Inserting a TCP ............................................................................................ 8-41
Modifying additional information ............................................................... 8-44
Inserting in an existing point sequence .................................................... 8-45
Inserting in front of "0" ............................................................................... 8-45
Inserting behind the last point in the sequence (SE) ............................... 8-45
Collisions due to insertions........................................................................ 8-46
Deleting a TCP ............................................................................................. 8-47
Deleting the current TCP............................................................................. 8-47
Deleting a specific TCP ............................................................................... 8-48
Deleting: from one point-No. to another point-No. ................................... 8-48
Page:0-6
Elektroplanung-und Anlagenbau
08.03.02
VRS 1
Deleting an entire program (sequence) ..................................................... 8-49
Deleting several programs (sequences).................................................... 8-50
Deleting a selected sequence..................................................................... 8-50
Deleting all sequences simultaneously ..................................................... 8-50
Danger of collisions due to deleting .......................................................... 8-51
9. PLC programming
9.
PLC programming ............................................................................... 9-1
The PLC controller ........................................................................................ 9-3
Outputs:.......................................................................................................... 9-3
Inputs:............................................................................................................. 9-4
General information regarding PLC programming ..................................... 9-5
PLC operators................................................................................................ 9-6
PLC-inputs and outputs ................................................................................ 9-9
PLC-inputs ................................................................................................... 9-11
PLC-outputs ................................................................................................. 9-11
PLC outputs ................................................................................................. 9-12
Switching on the PLC output...................................................................... 9-12
Switching off the PLC output ..................................................................... 9-13
Linking to an PLC output ............................................................................ 9-13
Inserting, correcting and deleting PLC lines: ........................................... 9-16
Inserting other links within the same line ................................................. 9-17
Correcting links within a line...................................................................... 9-21
Deleting links within a line.......................................................................... 9-22
Deleting an operand: ................................................................................... 9-22
Deleting an operator: .................................................................................. 9-23
PLC macros.................................................................................................. 9-24
Programming PLC macro calls .................................................................. 9-24
Displaying the PLC macro contents .......................................................... 9-25
PLC - wait conditions (WAIT)..................................................................... 9-26
PLC - gripper functions............................................................................... 9-29
Programming "QUICK" gripper functions ................................................. 9-30
Gripper and interbus docking function ..................................................... 9-31
PLC - flags.................................................................................................... 9-33
Switching PLC flags on and off and linking .............................................. 9-34
PLC - static flags ......................................................................................... 9-35
PLC arithmetical verification ...................................................................... 9-36
PLC markers ................................................................................................ 9-38
Switching on and off / linking PLC markers.............................................. 9-39
PLC - counter (arithm.)................................................................................ 9-41
PLC-counter programming ......................................................................... 9-42
PLC-timer ..................................................................................................... 9-46
PLC-timer in a point related PLC................................................................ 9-47
PLC-timer in a free running PLC ................................................................ 9-47
Timer value allocation................................................................................. 9-48
Starting / stopping the timer....................................................................... 9-49
PLC timer flag T ........................................................................................... 9-51
PLC-binary outputs ..................................................................................... 9-52
PLC binary output allocation...................................................................... 9-54
Analog output .............................................................................................. 9-58
Basis ............................................................................................................. 9-58
08.03.02
Elektroplanung-und Anlagenbau
Page:0-7
VRS 1
Programming the analog output ................................................................ 9-59
Compatibility................................................................................................ 9-61
PLC jump command .................................................................................... 9-62
Programming a jump command:................................................................ 9-62
Switching on a jump command:................................................................. 9-63
Switching off a jump command: ................................................................ 9-63
In order to link jump commands, proceed as follows: ............................. 9-63
PLC traversing conditions (TC).................................................................. 9-66
Programming ............................................................................................... 9-67
PLC jump conditions (JC)........................................................................... 9-69
Jump types................................................................................................... 9-70
Executing a jump ......................................................................................... 9-70
Sub-programs (S-P)..................................................................................... 9-71
Sub-program calls ....................................................................................... 9-71
What are relative S-Ps?............................................................................... 9-71
Relative 1...................................................................................................... 9-72
Relative 2...................................................................................................... 9-73
Special .......................................................................................................... 9-74
Calling up sub-programs ............................................................................ 9-74
Trajectory switching functions (TS)........................................................... 9-76
Boundary conditions and limitations......................................................... 9-77
Programming ............................................................................................... 9-81
The free running PLC .................................................................................. 9-86
Editing free running PLC programs [F1]: .................................................. 9-87
Copying free running PLC programs......................................................... 9-88
Deleting free running PLC programs ......................................................... 9-89
Setting the cycle time.................................................................................. 9-89
Starting a free running PLC program......................................................... 9-90
Stopping the free running PLC programs ................................................. 9-91
PLC operands .............................................................................................. 9-92
10. Single Step
10. Single Step ......................................................................................... 10-1
Operating mode: Single Step ..................................................................... 10-3
Running a programmed sequence............................................................. 10-4
Single Step FORWARDS (SSF)................................................................... 10-5
Continuing with wait or run conditions ..................................................... 10-6
SSF running up to the sequence end (SE) ................................................ 10-7
Single Step STOP (SSS).............................................................................. 10-8
Single Step REVERSE (SSR) ...................................................................... 10-9
SSR run up to the sequence start .............................................................. 10-9
Switching from SSF / SSR in sub-programs ........................................... 10-10
Traversing velocities when the protection lattice are linked out .......... 10-11
Modifying the settings............................................................................... 10-12
Setting the velocity override..................................................................... 10-12
Changing the sequence-No. ..................................................................... 10-12
Online information display ....................................................................... 10-13
Point selection ........................................................................................... 10-15
11. Automatic
11. Automatic ........................................................................................... 11-1
Page:0-8
Elektroplanung-und Anlagenbau
08.03.02
VRS 1
The automatic operating mode .................................................................. 11-3
Interruptions ................................................................................................ 11-4
Switching back on after an interruption .................................................... 11-4
Retaining the PLC outputs during drive OFF or EMERGENCY-OFF ....... 11-5
Ramp brakes in automatic .......................................................................... 11-5
Interruptions caused by system errors ..................................................... 11-6
Interruptions caused by timeouts .............................................................. 11-7
Retaining the free running PLC.................................................................. 11-8
Changing the velocity override online....................................................... 11-8
Online information display ......................................................................... 11-9
Remote diagnostics .................................................................................. 11-11
Diagnostic code table ............................................................................... 11-14
Example: evaluation of system errors by the free running PLC............ 11-15
Example of a peripheral error................................................................... 11-15
12. Service program
12. Service program ................................................................................ 12-1
Service program .......................................................................................... 12-3
Printing ......................................................................................................... 12-5
Setting the baud rate ................................................................................... 12-6
Printing the assignment lists...................................................................... 12-7
Printing the robot constants....................................................................... 12-7
Printing the PLC macros and the free running PLC programs............... 12-8
Printing the PLC macros............................................................................. 12-8
Printing the free running PLC programs ................................................... 12-8
Printing the point lists (sequences, sub-programs) ................................. 12-9
Formatting.................................................................................................. 12-11
Formatting a floppy disc (FD)................................................................... 12-11
Formatting an SRAM disc (RD) ................................................................ 12-13
Copying sequences to RD & RAM............................................................ 12-17
Duplicating special functions................................................................... 12-18
Insert mode (default setting) .................................................................... 12-18
Overwrite mode ......................................................................................... 12-18
Overwrite co-ordinates only mode........................................................... 12-19
Change co-ordinates only overwrite mode ............................................. 12-19
Saving / loading / comparing / deleting ................................................... 12-20
Marking....................................................................................................... 12-20
Marking sequences ................................................................................... 12-21
Marking of constants ................................................................................ 12-22
Saving......................................................................................................... 12-23
Loading....................................................................................................... 12-24
Error codes generated when reading in the seq. from FD, RD & RAM . 12-26
General information regarding logbooks ................................................ 12-27
Reading the logbook ................................................................................. 12-27
Saving the logbook to a floppy disc ........................................................ 12-28
Reading the logbook from a floppy disc ................................................. 12-29
Loading a new operating system using CPU 30 Rev 4........................... 12-30
Setting the time and date .......................................................................... 12-32
Updating from Version 1.13 or 1.14 to Version 2.0 ................................. 12-33
Loading and activating the auxiliary module .......................................... 12-35
Loading, saving, deleting and activating the sensor module:............... 12-36
08.03.02
Elektroplanung-und Anlagenbau
Page:0-9
VRS 1
Network configuration............................................................................... 12-39
Commissioning.......................................................................................... 12-39
Loading and saving a network configuration ......................................... 12-42
Modifying a network configuration .......................................................... 12-42
Deleting Multi-Point files from the RAM – disc ....................................... 12-43
13. Tests
13. Tests ................................................................................................... 13-1
Function tests .............................................................................................. 13-3
Testing the system inputs and outputs ..................................................... 13-4
Testing the PLC inputs and outputs .......................................................... 13-7
Testing the PLC outputs ............................................................................. 13-7
Displaying the PLC inputs .......................................................................... 13-9
Testing the joystick functions .................................................................... 13-9
Testing the robot axes .............................................................................. 13-11
Standardising the angle encoder (zero adjustment) .............................. 13-13
Standardising the angle encoder using adjustment offsets.................. 13-14
Standardising the axis using adjustment offsets ................................... 13-15
Reference position: automatic traversing ............................................... 13-16
Testing the digital / analog channels ....................................................... 13-18
14. Modifying the constants
14. Modifying the constants ................................................................... 14-1
Constants ..................................................................................................... 14-5
Modifying the constants ............................................................................. 14-5
Key disc........................................................................................................ 14-6
100 - 199 Servo constants........................................................................... 14-8
100 P-control amplification factor............................................................. 14-9
101 Velocity pre-control ............................................................................ 14-10
102 The maximum position error ............................................................. 14-12
103 Maximum bandwidth .......................................................................... 14-13
104 Vmax voltage ...................................................................................... 14-14
105 Acceleration pre-control .................................................................... 14-15
106 - 111 Servo parameters (VRS1C) ....................................................... 14-17
106 Amplification (P-content) ................................................................... 14-18
107 Time constant (I-content)................................................................... 14-19
108 Peak current reduction (PI-limit) ....................................................... 14-21
109 Nominal current monitoring (I2T)....................................................... 14-22
110 Inverting the servo set value ............................................................. 14-23
111 Inverting the positioning set value.................................................... 14-24
120 Integral content of the positioning control....................................... 14-25
130 Editing the incremental step widths ................................................. 14-26
200 - 299 Manipulator constants .............................................................. 14-27
200 Manipulator type ................................................................................. 14-28
201 Number of additional axes................................................................. 14-30
202 Maximum axis velocity (bit/5 ms) ...................................................... 14-31
203 - 230 Robot data.................................................................................. 14-32
203 Axis geometry..................................................................................... 14-33
204 AE basic settings................................................................................ 14-35
205 AE lower limit (lower software limit) ................................................. 14-36
Automatic setting of the AE lower limit ................................................... 14-37
Page:0-10
Elektroplanung-und Anlagenbau
08.03.02
VRS 1
206 AE upper limit (upper software limit) ................................................ 14-38
Automatic setting of the AE upper limit .................................................. 14-39
207 AE resolution (bit/90 degrees)........................................................... 14-39
208 Maximum axis acceleration (degs/sec2) ........................................... 14-40
Axis acceleration in Hand mode .............................................................. 14-41
209 Angle encoder rotational speed ........................................................ 14-42
210 Operating system version.................................................................. 14-43
211 ACTUATORS OFF time....................................................................... 14-44
212 Maximum axis velocity in Hand mode in %...................................... 14-45
213 Running in Automatic mode.............................................................. 14-46
214 Filter functions.................................................................................... 14-47
Trajectory filter .......................................................................................... 14-48
Axis filter .................................................................................................... 14-49
215 Joystick - selection............................................................................. 14-50
216 System and station editing ................................................................ 14-50
The text editor............................................................................................ 14-51
220 Angle offsets (degrees)....................................................................... 14-51
221 Axis coupling factors ......................................................................... 14-52
222 Automatic adjustment velocity (bit/5 ms)......................................... 14-53
223 EMT - Offset ........................................................................................ 14-54
224 Adjustment offsets ............................................................................. 14-55
230 Editing AE values ............................................................................... 14-57
231 Accelerating factors and braking factors for stopping ................... 14-58
300 - 349 Input / output constants............................................................ 14-60
300 Allocating gripper............................................................................... 14-60
Gripper type allocation.............................................................................. 14-62
The gripper text editor............................................................................... 14-64
301 Output attributes ................................................................................ 14-69
Condition.................................................................................................... 14-70
Dependencies ............................................................................................ 14-70
Compatibility.............................................................................................. 14-70
302 Defining static flags............................................................................ 14-70
303 Selective setting/clearing of flags (editing)...................................... 14-71
304 Entering the binary output format..................................................... 14-72
305 Defining the static outputs ................................................................ 14-74
306 Displaying a point number on a counter .......................................... 14-75
307 Displaying a velocity on a counter.................................................... 14-75
310 ... 319 SYSTEM I / O .......................................................................... 14-76
310 Sequence selection (binary/1 from n) ............................................... 14-77
311 Number of PLC-inputs........................................................................ 14-84
312 Number of PLC-outputs ..................................................................... 14-85
313 Inter-bus outputs ................................................................................ 14-86
314 Inter-bus inputs................................................................................... 14-87
315 SYS I/O displayed with FLAGS .......................................................... 14-89
320 Assigning the analog output channels............................................. 14-92
321 Attributes for analog outputs ............................................................ 14-95
330 PLC-macros ........................................................................................ 14-95
340 Setting the PLC-counters (arithm.) ................................................... 14-98
350 - 354 Interbus master menu ............................................................. 14-100
General information................................................................................. 14-100
Installation information:.......................................................................... 14-100
08.03.02
Elektroplanung-und Anlagenbau
Page:0-11
VRS 1
Preconditions: ......................................................................................... 14-101
Entering / Displaying of “Hexadecimal numbers”: ............................... 14-101
350 Executing interbus operations ........................................................ 14-102
351 Setting-up and editing the interbus ................................................ 14-103
Editing the IBM CFG ................................................................................ 14-104
IBM process data reference list.............................................................. 14-105
IBM Process data description list .......................................................... 14-106
Interbus – docking function: .................................................................. 14-107
352 Setting-up the interbus slave .......................................................... 14-109
353 Editing the interbus module names ................................................ 14-110
354 Interbus configuration...................................................................... 14-111
Activating / deactivating the master ...................................................... 14-112
Reading out the IBM configuration ........................................................ 14-112
IBM automatic configuration .................................................................. 14-112
Configuring using the control system ................................................... 14-113
Changing the output bytes using the control system .......................... 14-114
400 - 419 Tool constants ......................................................................... 14-116
400 Setting the tool for teaching ............................................................ 14-117
401 Tool measuring (TCP) ...................................................................... 14-117
Tool measuring (TCP external)............................................................... 14-119
Automatic tool measuring ...................................................................... 14-120
Automatic TCP-measuring...................................................................... 14-121
Procedure:................................................................................................ 14-121
Teaching the reference sequence .......................................................... 14-123
Automatic calculation of the TCP .......................................................... 14-123
TCP automatic measuring (using reference tool)................................. 14-124
Teaching the reference sequence .......................................................... 14-125
Automatic calculation of the TCP .......................................................... 14-126
Automatic determination of the tool orientation (RPY-angle) ............. 14-127
Teaching a reference sequence ............................................................. 14-128
Automatic calculation of the tool orientation........................................ 14-128
402 Tool loading data .............................................................................. 14-130
403 Calibration plate position for tool-piece determination ................ 14-131
Teaching a calibration plate positioning sequence: ............................ 14-133
420 - 439 Sensor constants .................................................................... 14-134
420 Switching on and off sensor functions........................................... 14-134
421 Loading the sensor module............................................................. 14-135
422 Sensor module constants................................................................ 14-136
460 - 479 Trajectory module constants ................................................. 14-139
460 Alternate inverse transformation (AIT) ........................................... 14-139
461 Additional axes transformation (AATF) .......................................... 14-140
462 AATF constants ................................................................................ 14-142
463 Transformation module.................................................................... 14-142
464 Kinematics in the [Hand] operating mode...................................... 14-143
465 Loading the S-P- module ................................................................. 14-144
466 Accuracy ball parameters ................................................................ 14-145
Radius matching...................................................................................... 14-145
467 Loading the robot model.................................................................. 14-146
468 Velocity profile selection ................................................................. 14-146
480 Hand console (teach box) language ............................................... 14-147
490 The free running PLC ....................................................................... 14-149
Page:0-12
Elektroplanung-und Anlagenbau
08.03.02
VRS 1
500 PLC-Operands .................................................................................. 14-150
555 Setting the system clock time ......................................................... 14-151
Stopping the load conditions ................................................................. 14-151
556 Setting the PLC - load ...................................................................... 14-152
08.03.02
Elektroplanung-und Anlagenbau
Page:0-13
VRS 1
Page:0-14
Elektroplanung-und Anlagenbau
08.03.02
VRS 1
1. Initial help
1.
Initial help ............................................................................................. 1-1
Teaching with the wrong tool ....................................................................... 1-3
Remedy: ......................................................................................................... 1-3
Implementation: ............................................................................................. 1-3
Correcting all sequences and sub-programs.............................................. 1-3
The tool dimensions have been changed.................................................... 1-5
Remedy: ......................................................................................................... 1-5
Implementation: ............................................................................................. 1-5
Problems after updating to version 1.13 ..................................................... 1-7
Spot welding robot ........................................................................................ 1-7
Increasing the cycle time .............................................................................. 1-7
07.03.02
Elektroplanung-und Anlagenbau
Page:1-1
VRS 1
Page:1-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Teaching with the wrong tool
The geometrical dimensions for the tool being used do not concur with those entered in the
constant type 401.
Remedy:
$ The correct tool dimensions must be entered in the constant type 401.
Read section "Setting 401 tool centre point (TCP)" that refers to this in chapter 14
"Modifying the constants".
$
$
Shift the axis angle back to '0'. A shift to '0' degree or '0' bit affects both the
recalculation and the saving of the previously programmed points via the trajectory
module.
The program optimisation is thereby carried out, so that after the correction of the tool
dimensions a shift in the joining angle having the correction value of '0' mm will be
started. With the shift to "0" bit (degree) the axis angle setting remains unchanged but
the cartesian co-ordinates will be recalculated. The trajectory module now has the
precise programmed points of the cartesian positions attained from the axis angles of
the programmed points and the now exact tool dimensions. These will be saved and
this guarantees the correct running of the programmed sequence.
Implementation:
] Press the function key [F1] in order to carry out the recalculation. The value '0' is
displayed automatically.
Shift joining angles
Start pos: 0
in 1/10 degree
A1 : 0
A2 : 0
A3 : 0
Start
Add. axis.
F1
F2
Ei 1 - 6 100% Z1
SEQUENCE:
End pos:
11
A4: 0
A5: 0
A6: 0
Bit
F3
5
|| HAND- ||
|| inputs
==========
TEACH
Cur-pos
F4
F5
Correcting all sequences and sub-programs
Should all of the programs and sub-programs need to be corrected to a specific value, i.e.
shifted to "0" bit linking angle after a software update was made, use "Shift-F1
(implementation) to select whether all sequences, all sub-programs or everything must be
shifted.
07.03.02
Elektroplanung-und Anlagenbau
Page:1-3
VRS 1
]
Press the function key Shift - F1 in order to carry out the recalculation. The value '0' is
displayed automatically.
Shift joining angle
Start pos: 0
in 1/10 degree
A1 : 0
A2 : 0
A3 : 0
Start
All
F1
F2
Ei 1 - 6 100% Z1
SEQUENCE: 5
End pos:
11
A4: 0
A5: 0
A6: 0
Sequence
F3
|| HAND- ||
|| inputs||
==========
F4
F5
$
Use [F1] to shift the currently selected sequence / sub-program
$
Use [F2] to shift all programmed sequences and sub-programs
$
Use [F3] to shift all the programmed sequences.
$
If the menu was called up using "Correct S-P", this is displayed under F3 = S-P.
Page:1-4
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The tool dimensions have been changed
The geometrical dimensions of the tool being used have been changed.
Remedy:
$ The correct tool dimensions must be entered in constant type 401.
Read section "Setting the 401 tool tip (TCP)" that refers to this in chapter 14
"Modifying the constants“.
$
$
Shifting the cartesian to '0'. A shift to '0' mm affects the recalculation and the saving
of the previously programmed points via the trajectory module.
The program optimisation is thereby carried out, so that after the correction of the tool
dimensions a cartesian shift having the correction value of '0' mm will be started. With
a cartesian shift to "0" mm the co-ordinates remain unchanged, the axis angle
settings will be recalculated. The trajectory module now has the precise axis angle
settings of the programmed points attained from the programmed cartesian points
and the now exact tool dimensions. These will be saved and guarantees the correct
running of the programmed sequence.
Implementation:
]
Press the function key [F1] in order to carry out the recalculation. The value '0' is
displayed automatically.
Shift cartesian point
Start pos: 0
In 0.1 mm
x:0
y:0
z:0
START EULER
F1
F2
Ei 1 - 6 100% Z1
SEQUENCE: 5
End pos:
11
in 0.1 degree
RPY BASIS
E1-R: 0
|| HAND- ||
E2-P: 0
|| inputs
||
E3-Y: 0
==========
HEAD
TEACH Cur-pos
F3
F4
F5
You also have the opportunity to correct all programs and sub-programs here, i.e. if the tool
dimensions have been changed. Use Shift-F1 (implement) to select whether all sequences,
all sub-programs or everything should be shifted.
07.03.02
Elektroplanung-und Anlagenbau
Page:1-5
VRS 1
]
Press the function key Shift - F1 in order to carry out the recalculation. The value '0' is
displayed automatically.
Shift cartesian points
Ei 1 - 6 100% Z1
SEQUENCE: 5
End pos:
11
in 0.1 degree
RPY BASIC
E1-R : 0
|| Hand||
E2-P: 0
|| inputs
||
E3-Y: 0
==========
Sequence
Start pos: 0
in 0.1 mm
x: 0
y: 0
z: 0
Start
All
F1
F2
F3
F4
F5
$
Use [F1] to shift the currently selected sequence/sub-program
$
Use [F2] to shift all programmed sequences and sub-programs
$
Use [F3] to shift all programmed sequences.
$
If the menu was called up using "Correct S-P", this is displayed under F3 = S-P.
Example:
Cartesian settings for a robot with a new tool. In this case a longer tool has been fitted.
3
2
4
1
5
Pa rt to b e p ro c e sse d
6 “SE”
O ld to o l
0
2
3
1
0
N e w to o l
Page:1-6
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Problems after updating to version 1.13
Spot welding robot
With version 1.13, the programmed tool centre point will be shifted regardless of the selected
velocity override. The time period that a spot welding piece requires for the shift, will be
realised with the programming of the accuracy sphere. With the older versions the shift
radius depended on the reduction of the velocity radius, so that the spot weld, regardless of
the selected velocity radius, always laid three dimensionally around the same position.
This functionality can be selected in version 1.13 by using constant type 466.
After the software update to version 1.13 has been made, the constant "Radius
optimisation" must be activated for spot welding robots!
Read the section for constant type 466 that refers to the above in chapter 14
"Modifying the constants".
Increasing the cycle time
In order to prevent the robot from moving, due to a multitude of SPS instructions, there is a
loading condition delay included in version 1.13. Increase the cycle time after the software
update to version 1.13, so that the constant types 555 and 556 are optimised accordingly.
Read the section for constant types 555 and 556 that refers to the above in chapter
14 "Modifying the constants".
07.03.02
Elektroplanung-und Anlagenbau
Page:1-7
VRS 1
Page:1-8
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
2. Stopped when actuator OFF/ON
07.03.02
Elektroplanung-und Anlagenbau
Page:2-1
VRS 1
Page:2-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
3. Programming conventions
3.
Programming conventions ................................................................. 3-1
General information....................................................................................... 3-3
Conventions for setting up the program sequences.................................. 3-4
Guide to operating robots using VRS1........................................................ 3-7
Preface: .......................................................................................................... 3-7
Commissioning.............................................................................................. 3-7
Setting up the robot sequences ................................................................... 3-8
Specifications for point inputs ..................................................................... 3-9
Jobs using PVC and epoxy-hard adhesive ............................................... 3-10
Re-welding using VRS 1 robots ................................................................. 3-12
PLC programming ....................................................................................... 3-13
Interlocking .................................................................................................. 3-13
Prior to transferring to production............................................................. 3-14
Changing the operating system version ................................................... 3-14
07.03.02
Elektroplanung-und Anlagenbau
Page:3-1
VRS 1
Page:3-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
General information
This chapter will help you to set up the initial program (movement sequence) for your robot
application.
Prior to the initial programming, please read the whole of chapter 5
"Commissioning".
•
•
•
•
Have you set the correct robot model?
Has the equipment been correctly standardised?
Have you measured the tool correctly and entered the dimensions under a tool number?
Have you selected the relevant tool number for teaching?
Learn by gaining experience from using the robot system. Program simple sequences using
different types of movements. The program that you have set up can be tested step by step.
Please read through the whole of chapter 10 "Single Step" which refers to this.
07.03.02
Elektroplanung-und Anlagenbau
Page:3-3
VRS 1
Conventions for setting up the program sequences
Certain programming conventions have been combined in the following. These should serve
as a guide when programming your application. It is necessary that you should have
programmed and tested specific sequences before you attend to your special automation
jobs.
it is important, that you learn to use the system through "playing" with simple jobs.
Try the following:
• Use a pencil to draw simple contours on paper that has been placed on the manual fitting
plate.
• Mill circles or squares in a block of polystyrene
After 2 or 3 days you should have the learnt the necessary routines and you can then start
with the programming of your own robot application.
You will find it easier to maintain the systems if you become accustomed to using the
following programming conventions.
]
Select the starting point (point 0) of a movement sequence so that this is positioned
out of the way of the part to be processed, supply direction and other transient
contours (e.g. standard position).
This makes it easier for you and as well as for the service personnel to service the
system.
“0 ” p o int fo r the
m o ve m e nt se q u e nc e
Pa rt to b e
p ro c e sse d
Ro b o t in sta nd a rd p o sitio n
Page:3-4
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Always program the end point (last point) of a sequence with the same position coordinates as the starting point of a sequence.
This prevents any possible collisions from occurring. The starting point co-ordinates
can be copied and used for the end point.
]
Terminate each sequence with the final characters "SE" (sequence end).
Read through the "Accepting imported co-ordinates“ section in chapter 8
"Program editing“, which refers to this.
3
2
1
4
5
Ro b o t o p e ra tin g se q u e n c e
Po in ts 1 - 7
0
6
7 “SE”
Sta rt a nd
end
]
Select the exact same positioning points as the start points (point 0) and end points
(last point) for all other sequences that you will be programming. This will prevent a
collision during a sequence changeover.
]
Accept the filter value for the start and end accelerations or return to the default
standard control value.
]
Set up the program so that a problem free automatic program run is guaranteed at
100% traversing velocity.
]
Program the manipulation robot so that the gripper are not scratched when being
opened or closed.
]
Document the PLC operands that have been used in your system (constant No.
500).
]
Copy the original movement sequence in a sequence No. that has not yet been
used before each correction job. Then it is always possible to undo the corrections
that you have made.
Read through the "Copying sequences to SRAM-DISC & RAM" section in
chapter 12.
07.03.02
Elektroplanung-und Anlagenbau
Page:3-5
VRS 1
]
After each programming or correction job, the new or modified sequences, subprograms, macros, PLC programs and constants must be archived to disc. Keep the
disc in a clean, secure location away from the production system.
]
Make a print out of a closed program and the constants.
]
Delete all programs that are no longer required from the robot system or archive
them to disc.
]
At the end of the program, reset all of the PLC outputs that have been used.
Page:3-6
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Guide to operating robots using VRS1
Preface:
This guide to programming robot runs is used to show the standard that is generally valid
throughout Volkswagen. It is normally accepted that different application cases have to have
their own standards and that is why there are minor changes to the standards in individual
factories or systems.
This guide does not make any claim to completeness. Changes are possible at any time.
Should it become necessary to deviate from this guide, this must only be undertaken after
consultation with the responsible department (E-planning, robot system or responsible
maintenance department).
Commissioning
] The system that is running should be standardised to the model of robot that it is
connected to, or checked to see that the robot model is correct (constant type 200).
]
Ensure that the operating system is at its normal status (constant type 210).
]
The tool diameters (TCP) of all tools (tongs, grippers and external TCPs) contained
in the system should be measured using the robot and entered (constant type
401).
]
The following Input - output constants must be checked or modified:
304: Binary output format
310: Sequence selection
313: Inter-bus outputs
314: Inter-bus inputs
350 – 354 : Interbus master/slave (an IBM master/slave card is a precondition
here)
]
The number of gripper and the gripper assignments must be entered via text
(constant type 300).
]
A check of the input / output levels must be carried out.
]
As an alternative, systems having several robots and identical Inter-bus input /
output assignments, can be tested up to 100% by using the Inter-bus inputs /
outputs of just one robot.
]
Because of this there is no need to test the following in-line equipment for
positioning or safety related Inter-bus inputs / outputs. (Positioning or safety
related reports such as, for example, profile free or lock-ups should normally
be checked out.)
]
The robot must be checked for the correct standardisation before each NEW
TEACHING or prior to any correction being carried out.
07.03.02
Elektroplanung-und Anlagenbau
Page:3-7
VRS 1
In order to prevent a manual axis error caused by relative movement during
standardisation, the following procedures must be adhered too:
1. Standardise axis 4.
2. Run axis 4 to electrical 0 degree (display in test).
3. Standardise axis 5 and leave in 0 degree position.
4. Standardise axis 6 (axes 1, 2 and 3 can be set up during any in-between
time).
]
Ensure that the tool number is correct before the new teaching of a sequence
(constant type 400).
]
A suitable method of storing the hand console must be found (this suitable storage
method must prevent the hand console from falling down. This could be, for
example, a hook from which the hand console clip can be hung).
Setting up the robot sequences
]
ESC must be used unconditionally for exiting the new teaching, correction and insert
menus. (Exit - together with operating mode selection switch prevents it being saved
to RAM - DISC).
]
A service position sequence must be set up according to the documentation. This
sequence should be set up so that it is guaranteed to run with each system status.
]
All start and end points and point 1 must be set on the same co-ordinate (in
corrections - single points - co-ordinates - external co-ordinates from point x).
]
When using sub-programs, the start and end points of the sub-programs may have
different co-ordinates.
]
If a sub-program is used, it must be ensured that the respective sequence can also
traverse forward and backwards without any sub-program jumps.
]
Vb=10% must be entered at point 0.
]
The sequences should be set so that a problem free automatic run is guaranteed at
100% traversing velocity (no bumping against the part, no leaving the trajectory with
error reports such as, for example, towing error, band width error etc.).
]
With welding robots, the electrode distance from the plate for new E-caps should be
selected so that the E-caps do not hit the plate whilst being closed. The approach
angle to the plate must be 90°.
]
The welding gripper are not to be shifted during closing (too large an accuracy ball)
and are not to cause a shunt during welding.
]
Manipulation robots are to be taught in such a way that the gripper are not scratched
during opening and closing.
]
You must keep to the standard specifications.
Page:3-8
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
The required cycle time is to be attained together with the gripper pressure settings,
the correct welding parameters as well as the correct traversing parameters (for
PTP - Vb, Ve, Aa and Ae a maximum of 100%, for LIN Aa and Ae a maximum of
1500 mm/s²).
]
Sequences, sub-programs and macros that are no longer required should be
deleted.
]
The cabinet and factory discs should be updated after each new teaching or
correcting (use "Verify" checking). Sequences, sub-programs, macros, inter-bus
assignments and gripper texts, as well as any available free-running PLC, axis
transformations and sensor constants should be saved to disc. Should the "Verify"
check generate a checksum error, the sequence should be shifted to "0" bit. ("0" bit
shifting - procedure: TEACH IN - CORRECTING - ENTIRE SEQUENCE - POINT
SHIFTING UP TO THE JOINING ANGLE - IMPLEMENTATION). Afterwards the
sequence should be resaved to disc.
Specifications for point inputs
]
PTP is normally entered for spot welding robots.
]
Jump commands online are normally forbidden.
]
Entering the traversing parameters for PTP : The standard values are to be retained
(100%). The accuracy can be varied (for rounding points between 10 and 200 1/10
DEGREES, for working points between 1 and 5 1/10 DEGREES).
]
LIN, CIR, and SPLINE interpolation:
The traversing velocities must be individually optimised, (max. 1500 mm/sec.)
maximum acceleration of 2300 mm/sec², standard values must be maintained for
return or filter. With regards to the accuracy, you must ensure that radius of the
accuracy ball is not greater than 40% of the path between the Px and Px - 1 or Px
and Px + 1 (Px = point to be processed) points, an accuracy of between 0 and 3
is permissible in the working point.
A max. of 10% of the path length is permissible with circular and spline points.
If it becomes necessary to modify the trajectory velocity, then the acceleration
must be realised with Vb and the deceleration realised with Ve.
If the robot swings or stagers during traversing, reduce the parameters.
(Reduce Aa or Ae for acceleration and reduce the velocity for staggering in the
curves).
]
LINEAR rounding points have an accuracy (Ac) that amounts to 1/5 of Ve.
]
CIRCULAR rounding points have an accuracy (Ac) that amounts to 1/10 of Ve.
]
SPLINE rounding points have an accuracy (Ac) that amounts to 1/5 of Ve.
07.03.02
Elektroplanung-und Anlagenbau
Page:3-9
VRS 1
]
If several points have been set on one co-ordinate, then Ve = 0 must be entered.
]
If several tools are to be used in a sequence, these must also be programmed in the
sequence as auxiliary information. During the new teaching the tool dimensions can
be entered using constant type 400.
]
If this was forgotten, then the tool diameters can be changed in the correction later
on. Afterwards the sequence must be shifted to "0" degree. (CORRECTING ENTIRE SEQUENCE - SHIFTING UP TO THE JOINING ANGLE IMPLEMENTATION)
Jobs using PVC and epoxy-hard adhesive
] The details of the quantity of adhesive should be entered together with Vtcp
(velocity dependent) and with an Offset of 900 mV.
]
The details for the quantity of air should also be entered with Vtcp and the same
value as for the quantity of adhesive but without an Offset.
]
Setting the sequence with 50% analogue output for the adhesive and air
quantities controls the adhesive.
]
Example:
]
Only after the optimisation of the adhesive control should you deviate from the 50%
setting.
]
If the Vtcp-value of a medium (adhesive / air) is changed, then the Vtcp-value for the
other medium must be changed to the same ratio.
Vb= 300 mm/sec
Ve= 300 mm/sec. ⇒
Vtcp = Vmax 600 mm/sec.
Note: A reduction in the Vtcp-value results in an increase in the quantity of adhesive
and a much stronger air-flow for the sequence. An increase in the Vtcp-value has the
opposite effect.
]
The distance to the component should amount to 30 - 40 mm.
Normally an adhesive weld is comprised of four points. Example:
Point Interpolation Vb=mm/s Ve=mm/s Aa=mm/s² Ae=mm/s² Accuracy Adhesive
No.
= mm
1
Lin
1000
1000
2300
2300
100
Off
2
Lin
max 400 max 400
2300
2300
1
On
3
Lin
max 400 max 400
2300
2300
1
Off
4
Lin
1000
1000
2300
2300
100
Off
]
In order to prevent a robot transient from occurring when changing the type of
interpolation, an additional LIN-point must be entered in front of the first or last LINpoint of the adhesive weld.
]
Setting up an adhesive weld:
Page:3-10
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
In order to start, points 1 and 4 must be taught. These points should be approx.
20mm in front of or after the actual adhesive weld. Afterwards the robot is allowed to
run from point 1 in the direction of point 4, up to the start of the adhesive weld. When
this position is reached, insert point 2.
Let the robot continue to run in the direction of point 4 and when the end of the weld
is reached, enter point 3.
Example for a short through-going adhesive weld:
Point Interpolation Vb=mm/s Ve=mm/s Aa=mm/s² Ae=mm/s² Accuracy Adhesive
No.
= mm
1
Lin
1000
1000
2300
2300
100
Off
2
Lin
max 400 max 400
2300
2300
1/5 of Ve
On
3
Lin
max 400 max 400
2300
2300
1/5 of Ve
4
Lin
max 400 max 400
2300
2300
1/5 of Ve
5
Lin
max 400 max 400
2300
2300
1/5 of Ve
6
Lin
max 400 max 400
2300
2300
1/5 of Ve
7
Lin
max 400 max 400
2300
2300
1/5 of Ve
Off
8
Lin
1000
1000
2300
2300
100
]
Correcting an adhesive weld:
Points 2 and 3 must be deleted from the weld that is to be corrected. Afterwards
points 1 and 4 can be geometrically modified. When the position of the weld is
correct, points 2 and 3 must be re-entered (see: Setting up an adhesive weld).
A useful aid for programming adhesive applications is the use of trajectory switching
functions. With these the adhesive track can be positioned with millimetre accuracy.
Read through the "Programming the trajectory switching functions" section in
chapter 9 "PLC programming".
07.03.02
Elektroplanung-und Anlagenbau
Page:3-11
VRS 1
Re-welding using VRS 1 robots
]
Three analog output sets must be used for re-welding. The output channels used for
this must be in accordance with the electrical planning.
1. Wire feeder: controls the wire quantity via an analogue value.
2. Welding current: controls the welding current via an analogue value.
3. Re-heating time: controls the re-heating time via an analogue value.
]
It must be taken into consideration that when setting up the sequence the welding
wire must be approx. 17mm out of the welding torch and the TCP positioned
precisely on the end of the weld.
]
The point related analog output sets for wire quantity, welding current and re-heating
time are to be declared as constant potentials in the sequence and individually
aligned to the point relationship.
]
The Vtcp velocity should amount to 12 mm/s - 17mm/s during the welding process, the
acceleration values Aa and Ae of 2300 mm/s² must be retained.
]
Linear and circular types of interpolation can be used, but the spline type of
interpolation cannot be used.
]
During the welding process you are not permitted to enter traversing conditions in
the point related robot-PLC.
]
The welding torch should be moved at an angle of 10° - 15° for the wire feeder.
]
It must be taken into consideration with sloping parts that are to be processed, that
the welding process follows the physical flow direction of the filler metal.
]
With regards to the precise alignment of parts that are to be processed, you must
also take into consideration that the column dimension of 0.5 mm must not be
exceeded.
]
The welding torch must be moved below an angle of 45° to the welding seam for
fillet welds.
]
The default macros for re-welding of the electrical planning are to be used.
Page:3-12
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
PLC programming
] The profile free zero point is to be switched on in point 0 and at the sequence end
and switched off in point 1.
]
Default macros are to be retained and can only be modified after consultation with
the responsible department, if this is necessary for functionality reasons.
]
The PLC interface is to be entered in accordance with the E-planning documentation
and the associated text should be transferred to the documentation for the PLC
operands.
]
If a sequence of PLC instructions is to be used several times in the same sequence,
these instructions are to be entered into a macro. The assignment of the macros
must agree with the E-planning.
]
Should other macros be necessary in addition to the default macros, macro overnesting (macro calls inside macros) must be avoided.
]
All outputs that have been switched on must be definitely switched off again, at the
latest at the end of the sequence. The exceptions from this are the binary and the
static outputs.
]
Position enabling and gripper functions that are required in the main and subprograms, should be set up in the respective main and sub-programs. If there are
positional inquiries in the sub-program (points 0, 1), you must be able to program
the inquiries online.
]
Position enabling and part controls must be prepared as additional traversing
conditions in the necessary sections of the sequence.
]
Outputs, that will still be required after the end of the sequence, are to be defined as
static.
]
The operands for the wait or traverse conditions can be combined in the flags,
provided that they will be used several times in the sequence. It must be taken into
consideration here, that only the flag in the declared sequence, that is also in this
sequence will be polled.
Interlocking
]
When interlocking two or more robots, the macros specifically provided for this must
be used. If the start of the interlocking is linked with wait conditions (e.g. for devices,
storage), these macros must not be used. An alternative method is to link the wait
conditions for the interlocking together with the other wait conditions (e.g. devices,
storage) in the robot PLC. The outputs for the interlocking can then be switched in
the point related PLC.
]
In areas where interlocking is to be used, an inquiry must be set up as a traversing
condition.
07.03.02
Elektroplanung-und Anlagenbau
Page:3-13
VRS 1
It must be taken into consideration in the last point of the interlocking, in which
the output of a locking "On" will be controlled, that no traversing condition has
been programmed for the associated locking.
Prior to transferring to production
]
The traversing range of axis 1 must be restricted so that there is no possibility of
collisions with the protection grills. Normally the software limits (constant types 205
and 206), hardware switching off and end stops are set, so that approx. 5° - 10°
more movement is permitted than is required by the sequences.
]
After the final setting up of the basic run, a print out of the system constants, marked
inputs, outputs and sequences for checking must be produced for the department
responsible (see preface). Projects using several robots, where the specific
application is the same, only require a sample print out from one robot.
]
After the final setting up of the entire run, an acceptance appointment must be
agreed with the department responsible. A print out must be produced from each
robot showing the system constants, written assignment lists, written macros and
written sequences for the acceptance. Furthermore, you must also prove that a disc
and an extra backup copy of the current status exist in each switching cabinet.
Changing the operating system version
It is also be taken into consideration that when changing the version of the operating system,
all those sequences and sub-programs that are already present must be shifted to "0" bit.
(Menu: press teaching (F1), enter sequence-up, correction (F2), entire program: geometry
(F2), point shifted up to the joining angle (F1), implement (Shift F1).
Should the shifting of certain sequences and sub-programs be lost, this can
result in the robot moving in other areas after the operating system has been
changed.
All operating system versions are upwards compatible only!
Page:3-14
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
4. Hand console (teach box)
4.
Hand console (teach box) ................................................................... 4-1
The hand console (teach box) ...................................................................... 4-3
Hand console display.................................................................................... 4-4
Function keys F1 - F5 .................................................................................... 4-5
Hand console keys ........................................................................................ 4-6
Joystick-key ................................................................................................... 4-6
Joystick-key with single traversing keys .................................................... 4-6
Co-ordinates system-key .............................................................................. 4-7
New start-key ................................................................................................. 4-7
Cursor-keys.................................................................................................... 4-8
Clear-key ........................................................................................................ 4-8
Abort-key........................................................................................................ 4-8
Return-key...................................................................................................... 4-8
Axis-traversing keys 1V - 6V 1R - 6R ........................................................ 4-8
Shift-key ......................................................................................................... 4-9
+/– Keys .......................................................................................................... 4-9
Decimal-keys.................................................................................................. 4-9
Pre-selecting the gripper-No. ....................................................................... 4-9
Gripper OPEN, gripper CLOSED .................................................................. 4-9
Drive system ON / OFF keys....................................................................... 4-10
Operating mode selection keys.................................................................. 4-10
Confirmation key ......................................................................................... 4-11
Joystick (optional)....................................................................................... 4-12
07.03.02
Elektroplanung-und Anlagenbau
Page:4-1
VRS 1
Page:4-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The hand console (teach box)
The following can be undertaken via the hand console:
• communicating with the robot controls
• the selection of the operating mode
• the displaying of error and status reports
• traversing the robot axes
• the programming of the operating sequences
• entering additional information
EMERG.-OFF
push button
Function
keys
Contrast
adjustment
Axis
traversing
buttons
Gripper
function
buttons
Drive
ON / OFF
07.03.02
Operating mode
selection button
Elektroplanung-und Anlagenbau
Page:4-3
VRS 1
Hand console display
The screen consists of 16 lines each having 40 positions for displaying alphanumerical
characters (letters and numbers). The upper 8 lines are supported in operating system
version 1.13 together with hand console software version 1.2 and SCC or RSC software
version 1.44 onwards.
The display is "cursor driven", i.e. the cursor control keys (up, down, left, right) can address
all possible input positions.
The following information is displayed in clear text:
• Displays the operating status
• Error and information reports
• Options (menu) that can be selected for display and
• Entering conditional operating characteristics.
Line 1
.
.
.
Line 15
Line 16
F1
F2
F3
F4
F5
Line 1:
This line can be used as a notepad by the operator or for orientation
purposes. The operating mode or the menu range that is currently selected is
always documented here.
Line 2:
Displays the name of the current sequence or sub-program.
Lines 3 - 9:
Commentary lines
Lines 15+16: These lines normally contain information or entries regarding further menu
branches thought the function keys F1 - F5 (soft-keys) that lay directly at the
bottom.
All other lines are used for displaying and entering correction data. You will find a description
of the function keys on the next pages.
Page:4-4
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Function keys F1 - F5
These function keys are assigned functions in accordance with the menus being shown in
the display.
These function assignments are displayed in the last lines of the screen (lines 16 or 15 + 16).
New
teaching
Correction
Insert
Delete
F1
F2
F3
F4
F5
Here is an example:
In the menus listed below, pressing the respective function key has the following effect:
[F1]
Select and branch to menu
New teaching
[F2]
Select and branch to menu
Edit
[F3]
Select and branch to menu
Insert
[F4]
Select and branch to menu
Delete
[F5]
No function assigned
07.03.02
Elektroplanung-und Anlagenbau
Page:4-5
VRS 1
Hand console keys
The hand console keys are described in detail on the following pages.
Joystick-key
This key functions the same as an activation key for the traversing of the robot axes
together with the option of using the joystick. When the key is not pressed down, the
joystick is no longer active.
Joystick-key with single traversing keys
The cartesian traversing of the axes in the [Hand] operating mode can be undertaken by
using either the joystick or a combination of joystick keys and individual axis traversing.
+
1V
+
1R
+
2V
+
2R
+
3V
+
3R
+
4V
+
4R
+
z
z
+
z
z
+
z
z
+
z
z
Page:4-6
Fast cartesian
in
X-direction
positive
negative
Y-direction
positive
negative
Z-direction
positive
negative
Slow cartesian
in
X-direction
positive
negative
Y-direction
positive
negative
Z-direction
positive
negative
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Co-ordinates system-key
This key sets the type of manual traversing of the robot axes. With systems that
have more than 6 axes, pressing this key effects a switching over from axes 1 - 6 to
axes 7 - 12 and vice versa.
In conjunction with the [Joystick-key] this is used to switch between the different types of
cartesian traversing.
New start-key
NEW A new start includes the resetting of the current sequence-No., all flags, outputs,
START timer, binary outputs and static flags.
For safety reasons the [New start] button only first become active in combination with two
other keys:
Press the following keys within 2 seconds to force the implementation of the new start:
NEW
START
©
]
Press [New start] key.
]
Afterwards press the [Joystick] key in addition to this,
]
let both keys go and then
]
acknowledge by pressing the [Return] key within 2 sec.
Attention! Danger of collisions!
After a new start and the switching on of the drive system, the robot will traverse
the direct path of its axis to the sequence "0" point.
07.03.02
Elektroplanung-und Anlagenbau
Page:4-7
VRS 1
Cursor-keys
Î Ð Í Ï
Use these keys to bring the display cursor to the required
entering position.
Clear-key
Every time this is pressed the position to the left of the cursor in the display will
be deleted!
Abort-key
An abort here means aborting the current menu that is being used.
ESC
Press this key to jump back the next higher menu.
Return-key
Press this key to mark the entry as valid and transfer it to the controller.
©
Axis-traversing keys 1V - 6V 1R - 6R
If the drive system is switched on, robot axes 1 - 6 traverse in direction F
F 1 /6 R
(forwards) or in direction R (reverse) according to which key has been
pressed.
NOTE:
If there are more than 6 axes, you can switch over to axis traversing keys 7 - 12 by pressing
the co-ordinating key. The traversing keys are then assigned to the axes as follows:
1V / 1R
=
axis 7
2V / 2R
=
axis 8
3V / 3R
=
axis 9
4V / 4R
=
axis 10
5V / 5R
=
axis 11
6V / 6R
=
axis 12
Page:4-8
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Shift-key
If the shift key is pressed, a pre-defined 2nd level hand console key will be activated,
e.g. by pressing this key conjunction with the left / right cursor keys in the correction
function, you can page (forwards or backwards) from one point-No. to another
without having to leave the programming level.
+/– Keys
+
These keys are used for entering the signed values.
Use these keys to switch the online display level in [Automatic] and [Single
Step] operating modes.
-
Decimal-keys
Use these keys to enter all numerical values, e.g. sequence-No., point-No.,
0
9
part constants etc.
Pre-selecting the gripper-No.
Press the [Gripper+] key to increase the gripper-No. displayed on the screen
by 1, reduce it by 1 by pressing the [Gripper-] key.
Gripper OPEN, gripper CLOSED
Use this key to (OPEN) and (CLOSE) the gripper.
Attention! Danger of injury!
With these keys you cancel actions of the connected equipment. This means that
there is a danger to life and limb for both you and third parties. Follow the safety
instructions for the robots and the connected equipment. Handle carefully and
conscientiously so that other people are not endangered.
For safety reasons the selected function will not be implemented when the respective
key is pressed, but a gripper information menu will be displayed on the screen and an
acknowledgement is required first.
07.03.02
Elektroplanung-und Anlagenbau
Page:4-9
VRS 1
Drive system ON / OFF keys
Use these keys to switch each drive system on or off.
Drive
OFF
Drive
ON
Attention! Danger of injury!
The robot can undertake dangerous movements when the drive system is
switched on. These can result in being crushed, broken bones, severing of limbs
or in death. Abide by the instructions given in chapter 5 "Commissioning" during
commissioning as well as after any modifications have been made to the system.
Operating mode selection keys
The following operating modes can be selected via the keys:
AUTOMATIC
Automatic running of the
programmed working sequences
SINGLE-STEP
Single-step control for the
Alignment mode
HAND
Teaching, test, delete,
inserting and correcting.
Page:4-10
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Confirmation key
This key has been provided for your personal safety. It is required for the testing of
movement sequences when the protection lattices have been removed or linked out. It is
linked to the drive-on circuit and has 2 switch positions. The key is fitted on the rear side of
the hand console and can be used by both left and right-handed people.
You then only have to switch the drive system on, if a confirmation is present.
Key not pressed:
No confirmation
Key pressed:
Confirmation
07.03.02
Elektroplanung-und Anlagenbau
Page:4-11
VRS 1
Joystick (optional)
The joystick enables you to co-ordinate the traversing of all axes together with the individual
axis traversing keys.
By switching on the drive system and using the hand console Joystick key, the robot tip
(TCP) can be moved under cartesian traversing or swung around.
A further description of the cartesian traversing options can also be found in
chapter 6 in the "Cartesian traversing" section.
The traversing velocity is dependant on the amount of joystick displacement from the centre
and the axis traversing direction is also dependant on the displacement direction.
+Y
-X
+Z
-Z
+X
-Y
Page:4-12
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
5. Commissioning
5.
Commissioning.................................................................................... 5-1
Error clearing procedures............................................................................. 5-4
Checking the robot model ............................................................................ 5-5
Changing the robot model ............................................................................ 5-7
Checking drive system ON ........................................................................... 5-8
Commissioning the robots ........................................................................... 5-9
Checking the robot operating and traversing ranges .............................. 5-10
Checking the maximum operating range .................................................. 5-10
Checking the standardised position.......................................................... 5-11
Commissioning the additional axes .......................................................... 5-11
Constant 201 ................................................................................................ 5-12
Constant 209 ................................................................................................ 5-12
Constant 207 ................................................................................................ 5-12
Constant 204 ................................................................................................ 5-12
Constant 202 ................................................................................................ 5-13
Constants 205+206 ...................................................................................... 5-13
Constant 103 ................................................................................................ 5-13
Constant 102 ................................................................................................ 5-13
Constant 108 ................................................................................................ 5-14
Constants 106 ... 111 ................................................................................... 5-14
Tools ............................................................................................................. 5-15
Selecting tools for teaching........................................................................ 5-16
Entering the tool measurements (TCP) ..................................................... 5-17
Tool assignments ........................................................................................ 5-17
Automatic tool measuring .......................................................................... 5-17
Gripper.......................................................................................................... 5-18
Assigning the gripper-No. and the gripper models .................................. 5-18
07.03.02
Elektroplanung-und Anlagenbau
Page:5-1
VRS 1
Page:5-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Activating the controls
The system must be electrically and mechanically checked prior to the
commissioning. Abide by the safety instructions and operating procedures for
your specific robot model.
]
Switch on the mains switch on the switching cabinet.
The following is displayed on the screen.
V
V
V
V
V
V
V
V
V
V
V V
V
F1
F2
RRRR
R
R
R
R
RRRR
RR
R R
R
R
F3
SSS
1
S S 11
S
1 1
SSS
1
S
1
S
S
1
SSS
1
F4
F5
Starting VRS1 Vx_version 2.0
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:5-3
VRS 1
The system will now run up and be configured.
COLD START
VRS1 is reading the point lists
F1
F2
F3
F4
F5
VRS 1 is waiting for the PLC to be initialised
VRS 1 is waiting for AUTO to be initialised
VRS 1 is waiting for HAND/HART to be initialised
F1
]
F2
F3
F4
F5
Select the operating mode [Hand].
The system will report this in the main menu displayed on the screen.
HAND – mode
Ei 1 .. 6 100% Z1
F1 = TEACH - IN
F2 = MODIFY CONSTANTS
F3 = TEST
F4 = SERVICE PROGRAM
F5 = OVERVIEW
F1
F2
F3
F4
F5
If this screen is not displayed after selecting the operating mode [Hand], an error has
occurred.
Error clearing procedures
Carry out a new system start. To do this, switch off at the switching cabinet and then switch
back on again.
If the error appears again, check the system according to the operating manual. Also read
through the "Function descriptions" and "Service" chapters in the operating manual.
Page:5-4
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Checking the robot model
The controller has been so designed, that different mechanical offsets and traversing
characteristics can be set up for the robot mechanics. However this is conditional on those
model specific constants required for an exact calculation of the axis movement for the
respective robots being available to the controller.
During the commissioning, the model number of the robot that has been installed must be
checked and corrected if necessary.
]
Select the [Hand] operating mode.
HAND – mode
Ei 1 .. 6 100% Z1
F1 = TEACH - IN
F2 = MODIFY CONSTANTS
F3 = TEST
F4 = SERVICE PROGRAM
F5 = OVER VIEW
F1
]
F2
F3
F4
F5
Press the [F2] function key.
The following menu will be displayed.
CONSTANTS
F1 = Servo constants
F2 = Manipulator constants
F3 = On/Off constants
F4 = Tool constants
F5 = Continue
Input:
F1
07.03.02
F2
F3
100
200
300
400
F4
.. 199
.. 299
.. 399
.. 499
F5
Elektroplanung-und Anlagenbau
Page:5-5
VRS 1
]
Enter the number "200" to bring up the Equipment model menu and press the
[Return] key.
]
To check the model number of the robot, press the [Esc] key. The following screen
will be displayed.
200:
Manipulator type
Installed type:
VK010 (35)
Key disc is missing. No modifications!
F1
]
F2
F3
F4
F5
If the displayed model number concurs with the robot, return to the constants menu
by pressing the [Esc] key.
If the displayed equipment model number does not concur with the installed robot, the
relevant model must be corrected.
Page:5-6
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Changing the robot model
]
In order to change the number of the robot model, enter constant No. 200 and press
the [Return] key.
The installed robot model can now be corrected using the key disc.
Please put the key disc in...
and acknowledge using F1 !
F1
F2
F3
F4
F5
Modifying the permanently saved system data is only possible in
conjunction with the key disc!
]
Place the key disc in the controller floppy drive.
]
Acknowledge using [F1].
After you have put the disc in and acknowledged using [F1], the disc will be checked. The
following report will be displayed:
Checking disc...
F1
F2
F3
F4
F5
When the disc has been successfully checked, the model number of the installed robot will
be displayed.
200:
Manipulator type
Installed type:
VK010 ( 35)
25: G100LCP
29: G121LH
33: G81LH
26: G121
30: G81
34: VK120_1
27: G121L
31: G81L
35:>VK010
28: G121H
32: G81H
36: VK030
Select: VK010 ( 35)
Standardise
Info
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:5-7
VRS 1
Use the [Cursor] keys to select the robot model:
[Cursor up]
=
Line +
[Cursor down] =
Line [Cursor right] =
Column +
[Cursor left]
=
Column ]
After selecting the applicable robot model, press the [F1] function key.
The system specific constants for the new robot model will be loaded in from the disc
afterwards and immediately used by the controller.
Checking drive system ON
When the correct robot model has been installed, the checking of the "Drive-ON" circuit is
carried out.
Attention! Danger of injury!
When the drive system is switched on, the robot can undertake dangerous
movements. During the commissioning, only switch the drive system on, when
no other personnel are working behind the protection devices. Abide by the other
safety instructions.
Switch on the drive system by pressing both of the [Drive ON] keys.
If the drive system does not switch on, check the protection devices.
If the drive system only switches on for a short period of time, a standardisation
or servo error has occurred.
The relevant error will be displayed in an error report on the screen.
• If a standardisation error has occurred, then the relevant axis must be adjusted as
described in the "Standardising the angle encoder (zero adjustment)" section in
chapter 13 "Testing".
Page:5-8
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Commissioning the robots
During the commissioning of the robots, each axis must be individual traversed using the
[1V] - [6V] or [1R] - [6R] axis traversing keys.
If an error occurs during the traversing, e.g. a brake does not release or a motor or resolver
connection is not in order, the drive system will be automatically switched off.
The relevant error report will be displayed on the screen.
The axis displayed on the screen must be checked along with all of the components (motor /
resolver / servo lag error constant).
POSITION ERROR CONTROL
AXIS:
POSITION ERROR:
Acknowledge with ESC / MOS
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:5-9
VRS 1
Checking the robot operating and traversing ranges
Without fail, the installation site of the robot must be checked to see whether the tool piece
that is to be processed can be reached by the robot (operating area).
]
Select the operating mode [Hand].
]
Traverse the axis that has the flange mounted tool to the maximum operating range,
use the axis traversing keys [1V-6V] or [1R-6R] or [Joystick] for this.
]
If the traversing range is insufficient, the robot's tool position must be changed
or
]
the location of the robot must be moved.
Checking the maximum operating range
Without fail, the installation site of the robot must be checked to see whether the three basic
axes (axes 1, 2, 3) must be limited within the movement areas (problem areas within the
maximum range of the robots are, for example, walls, columns, ceiling beams, fencing and
supply lines).
If the robot is mechanically limited, the software limits must be re-adjusted accordingly. This
prevents the axis inadvertently running into a mechanical stop during the programming.
Further information regarding the setting up can be found in the "205 AE minimum"
or "206 AE maximum" sections of chapter 14 "Modifying the constants".
Page:5-10
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Checking the standardised position
After you have traversed all 6 axes in the forward and backwards directions, the standard
position for each axis must be checked.
]
To do this, traverse each axis to the reference position.
Also read the "Automatic running to the reference position" section in chapter 13
"Testing".
The relevant axis must be at the mechanically marked position after running to its reference
position. Otherwise the axis must be re-calibrated and standardised.
Also read the "Standardising the angle encoder (zero position adjustment)" section
in chapter 13 "Testing".
In order to check the manual axes (axes 4, 5, 6), all 3 manual axes must be in their reference
positions. Otherwise this can result in the wrong adjustment being made due to the
mechanical linking.
Commissioning the additional axes
If additional axes have been integrated into the robot system, the respective constants for the
axes definition of the mechanics that have not been linked to the robot must be additionally
defined and entered.
These entries are also required if a robot is being used that is not an articulated arm robot
(e.g. gantry robot).
A precise description can be found in chapter 14 "Modifying the constants".
The constants that are required for the commissioning of the robots are listed together with a
short description on the following pages.
07.03.02
Elektroplanung-und Anlagenbau
Page:5-11
VRS 1
Constant 201
The number of additional axes is set in this type of constant. This is the pre-requisite for
entering all other constants.
Constant 209
The entered angle encoder revolutions for each axis are shown here and must be corrected
without fail during a AE-change.
256 revolutions = 18 bit encoder
4096 revolutions = 24 bit encoder
Axis drive systems that have AC motors use the resolver as the path measuring system. In
this case, a rotational velocity of 4096 is set as the default.
Constant 207
The angle encoder resolution (bit/90 degree) is shown in this type of constant. This value
corresponds to the number of bits that are set up for a AE carrying out a mechanical axis
rotation of 90 degrees.
Formula:
Angle encoder resolution =
entire transfer x AE rotational velocity x 90°/360°
Constant 204
The angle encoder basic settings are determined and entered here. The initial AE settings
should be entered for the approximate centre of the traversing range, i.e. with regards to the
initial AE settings, no overrunning or under-running may occur during the entire traversing.
The lower limit cannot be smaller than "0" and the upper limit cannot be greater than the
maximum AE value.
Example:
Axis traversing range
Bits per 90 degrees
Encoding
1:256
Selected basic setting for AE
Page:5-12
=
=
=
=
+/- 180 degrees
136.168 bit
1.048.576 bit
500.000 bit
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The angle encoder 1:4096 as well as all of the resolvers have a resolution of 16.777.216 bits.
Normally the initial AE settings will be selected at 8,000,000 bits.
Constant 202
The maximum axis velocity (bit/5ms) is determined here. Normally this constant has already
been entered.
Pre-requisites for the calculation are the entering of the bit/90 degrees and the traversing
velocity of the axis.
Formula:
Axis velocity (bit/5ms ) =
angle encoder resolution (bit/90degrees) x 4 traversing velocity (degrees/5ms )
Setting of the degrees for the rotating axes, are set in mm, cm or m for linear axes,
depending on the requirements.
Constants 205+206
The axis traversing range limits that will be monitored by the computer (software controlled)
are specified in these constants. The traversing range is divided between the upper and
lower limits.
For a precise description of the types of constants, please read through the "205
and 206" section in chapter 14 "Modifying the constants".
Constant 103
The maximum bandwidth is determined here. This value should be greater than that in
constant 202 (axis velocity) by a factor of 2.
Constant 102
The maximum permitted servo lag is entered in these types of constants. It should be greater
than the axis velocity (constant 202) by an approximate factor of 4.
A precise setting can only be made after the axis has been moved in the [Automatic]
operating mode and the dynamic of the entire system has been optimised.
07.03.02
Elektroplanung-und Anlagenbau
Page:5-13
VRS 1
Constant 108
This acceleration constant enables the approximate axis velocity and run-up time of the
respective axis to be calculated.
A = V / ∆ t (degree / s²)
The acceleration setting for linear axes must be entered in degrees/s, in cm/s or mm/s.
Example for the robot axis run-up time:
∆t basic axes 0.5 - 1 s
∆t manual axes 0.2 - 0.5 s
The acceleration can also be determined using measuring techniques to measure the tacho
signals and the motor currents and optimising it afterwards.
Constants 106 ... 111
When using a VRS1C controller, additional control constants must be entered. This control
constant overrides the servo amplifier control procedures.
Attention!
The control constants must be handled with great care. The servo module and
the motors can be destroyed when handled improperly.
In order to set up the servo constants, please read the "Servo constants"
section in chapter 14 "Modifying the constants".
Page:5-14
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Tools
The controller "Tool" command covers all of the devices fitted to the robot. Therefore the
device name is irrelevant, e.g. handling gripper, welding gripper, adhesive pistol, multigripper, screws, etc.
It is critical that when fitting a tool (flange mounted on axis 6), the geometrical offsets and
consequently the robot's working point (TCP) are modified.
]
It is therefore a necessary requirement that before starting the programming of the
TCP the tool fitted on the flange is measured and the corresponding values
(measurements taken in x, y, z as well as the turning angles a, b, c) are entered in
the controller.
]
Up to 16 tool-pieces with different measurements can be used within a robot
application. The respective measurements should be entered and saved under the
relevant 1 - 16 tool-piece numbers. Furthermore, tool-piece 8 is the reference toolpiece.
]
When changing tools, you must take into account that the relevant tool-No. is preselected together with constant type 400.
Warning! Danger of collisions!
Only when the correct tool number has been entered will the mechanical offsets
(TCP) be correctly set up in automatic or in single-step operation. Otherwise this
can result in a collision. During teaching of the operating sequence, pay attention
to the correct tool number.
For a precise description of the tool selection process, please read through the
"Tool constants" section in chapter 14 "Modifying the constants".
07.03.02
Elektroplanung-und Anlagenbau
Page:5-15
VRS 1
Selecting tools for teaching
Hand-F2-F4-F1
(400)
Up to 16 tool-pieces having different measurements can be used within a robot application.
The respective measurements must be entered and saved under the relevant tool-piece
number 1-16.
The relevant tool No. that will be used must be entered for the teaching of an
operating sequence. Tool No. 1 has been pre-entered as the default.
Remarks:
The reference tool needed for the entering of the automatic measuring of the TCP does not
need to be taken into consideration, as it is separately defined and handled as an additional
(8) tool by the controller.
For a precise description please read the "Measuring TCP using reference tools"
section in chapter 14 "Modifying the constants".
]
Select the [Hand] operating mode. Press the [F2], [F4] and [F1] function keys.
]
The following menu will be displayed on the screen:
400: Select tool for TEACHING
Minimum : 1
Maximum : 16
Default: 1
Abort using ESC
Input:
(1 .. 16)
F1
]
F2
F3
F4
F5
After entering and acknowledging by using the [Return] key, the mechanical offset
values of the selected tool-No. must be activated for calculating the area point coordinates.
For a precise description of the tool selection, please read the "Setting up the tools
for teaching" section in chapter 14 "Modifying the constants".
Page:5-16
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Entering the tool measurements (TCP)
Hand-F2-F4-F2
(401)
For each tool that is included in the robot operating sequence, the so-called operating point
(TCP = Tool Centre Point) must be measured and entered as tool offsets before the
programming is carried out.
The TCP is the point on the tool, where the actual processing of the tool piece will be carried
out, e.g.:
Welding gripper
Handling gripper
Spray gun
:TCP between both electrodes
:TCP between the gripping jaws
:TCP at the nozzle head
A precise description can be found in the "401 tool TCP offsets" section in chapter
14 "Modifying the constants".
Tool assignments
The controller supports two options for tool assignments:
• HEAD:
permanently fitted on robot head (flange axis 6)
• BASIC:
Externally fitted tool (here the robot moves the work piece to the tool)
Automatic tool measuring
In addition to the manual measuring the tool offsets can also be made automatically.
A precise description can be found in the " Automatic tool measuring" section in
chapter 14 "Modifying the constants".
07.03.02
Elektroplanung-und Anlagenbau
Page:5-17
VRS 1
Gripper
The "Gripper" command is not present in the controller for the handling gripper or the welding
gripper, but for the functional status of the tools (e.g. handling gripper OPEN / CLOSED,
docking cylinder FORWARDS / BACKWARDS, interlock OPEN / CLOSED, welding gripper
OPEN / CLOSED, actual OPEN / actual CLOSED, adhesive pistol OPEN / CLOSED etc.).
A total of 16 gripper numbers (1-16) are available for use, to which, depending on the
application, a type can be allocated:
Type 1 = HANDLING
this type always has 2 output relays assigned as the default for
Oopen and Oclose. (Oopen signifies "Output for function gripper
open“)
Type 2 = WELDING
In addition to the 2 output relays, 2 inputs for the ACTUAL OPEN
and ACTUAL CLOSED (Iopen / Iclose) acknowledgement
reports must also be assigned for this type.
Type 3 = WELDING
MACRO
Complex welding runs can be combined in one macro and
saved under a freely selectable macro-No. (0 - 99).
Type 4 = GRIPPER SENSOR This model can only be programmed in conjunction with a
ZTF-module
A precise description can be found in the "PLC macro" section in chapter 9 "PLC
programming".
Assigning the gripper-No. and the gripper models
Hand-F2-F3-F1-F1 (300)
The controller differentiates between the different types of gripper:
Type 1= Handling (Hand operation)
Type 2= Welding
Type 3= Welding macro
Up to 16 sets of gripper can be operated (gripper-No. 1-16). The GRIPPER OPEN /
CLOSED functions are operated by relays, that are controlled via the programmable output
commands Oopen or Oclosed.
When using the welding gripper it is an additional requirement, that the implemented function
GRIPPER ARE OPEN / CLOSED is sent to the controller as an acknowledgement.
This is carried out via the input commands Iopen or Iclosed.
In order to reduce the amount of programming for a complex welding process, the
corresponding welding gripper-No. for type 3 = can be assigned to a welding macro.
!
This welding macro must be programmed into the PLC once. The PLC instructions as
agreed for the complex welding process must be saved under MACRO - No. 0.
Page:5-18
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
In order to be able to start the welding program now, only the PLC instruction: MACRO 0 has
to be entered into the respective area point.
Provided the output as well as the input commands are controlled and operated by the PLC.
For this it is necessary that the specific outputs and corresponding inputs are assigned to
these gripper functions.
]
Select the [HAND] operating mode
]
Press the [F2], [F3], [F1] and [F1] function keys one after the other.
The following report will be displayed on the screen:
300:
Gripper assignments
NO. Type
1
1
Aopen Aclosed
11
12
NR. +
NR.-
F1
F2
DELETE
F3
Eopen Eclosed
EDIT
F4
EDITOR
F5
If a gripper has not been entered, the cursor blinks beneath the empty input field for ‘Type’.
The remaining fields are empty in any case.
The following are displayed in this example:
Gripper-No. 1
Gripper-type 1 = HANDLING
Output relay No. 11 for OPEN-gripper
Output relay No. 12 for CLOSE-gripper
Function key assignments:
F1 = gripper -No. +1
F2 = gripper -No. -1
F3 = deletes the displayed assignment
F4 = corrects the type of gripper displayed
F5 = gripper -editor (clear text input for gripper identification).
07.03.02
Elektroplanung-und Anlagenbau
Page:5-19
VRS 1
Page:5-20
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
6. Hand operation
6.
Hand operation .................................................................................... 6-1
The Hand Operating Mode ............................................................................ 6-3
Operating in the Hand operating mode ....................................................... 6-4
Traversing individual axes............................................................................ 6-5
Traversing the additional axes ..................................................................... 6-6
Cartesian traversing ...................................................................................... 6-6
Selecting the traversing ................................................................................ 6-7
Cartesian movement in BAS0WA global co-ordinates system ................. 6-8
Cartesian movement in BAS1WA basic co-ordination system ................. 6-9
Cartesian movement in HEADWA head co-ordination system.................. 6-9
Rotating the tool tip (TCP) SWVLWA (PIVOWA) ....................................... 6-10
Incremental traversing ................................................................................ 6-11
Traversing velocity in hand mode.............................................................. 6-12
Gripper functions ........................................................................................ 6-13
Pre-selecting the gripper-No. ..................................................................... 6-13
Gripper functions [Gripper OPEN] and [Gripper CLOSED]...................... 6-13
Releasing the gripper function through a permanent signal................... 6-14
Gripper text editor ....................................................................................... 6-16
Linking out the protection lattices ............................................................. 6-17
07.03.02
Elektroplanung-und Anlagenbau
Page:6-1
VRS 1
Page:6-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The Hand Operating Mode
The programming, system definition, system testing and diverse service program functions
are made available for use in this operating mode.
]
After selecting the [Hand] operating mode, the following main menu will be
displayed on the screen:
HAND – MODE
Ei 1 - 6 100% Z01
F1 = TEACHING
Tool 1
F2 = MODIFY CONSTANTS
F3 = TEST
F4 = SERVICE PROGRAM
F5 = OVERVIEW
F1
]
F2
F3
F4
F5
Press one of the [F1] - [F5] function keys to jump to the required function as
displayed on the screen.
Teaching
The teaching for the robot traversing program (sequences) and all modifications (entering,
deleting and corrections) to the existing programmed sequences are made here.
Modifying constants
The entries or the corrections to system specific constants can be entered under this menu
option.
Read chapter 14 "Modifying the constants" for more information.
Testing
The operating functions of all individual system components can be tested here.
Read chapter 13 "Testing" for more information.
07.03.02
Elektroplanung-und Anlagenbau
Page:6-3
VRS 1
Service program
Use the service program to format the SRAM disc and the floppy, copy data and to make
backups. In addition, you can also make printouts, read in and save sequences and
constants, use the upload/download function as well as loading a new operating system.
Read chapter 12 "Service Program" for more information.
Operating in the Hand operating mode
In the [Hand] operating mode, there are two modes of basic traversing for the robot using
the traversing keys: individual axes or cartesian in the area.
]
Select the [Hand] operating mode. The following main menu will be displayed:
HAND–MODE
Ei 1 - 6
F1 = TEACHING
F2 = MODIFY CONSTANTS
F3 = TEST
F4 = SERVICE PROGRAM
F5 = OVERVIEW
F1
F2
F3
100% Z01
Tool 1
F4
F5
The following information is displayed in the 1st line of the screen alongside the selected
[Hand] operating mode:
• The selected type of traversing is displayed via [Ei 1 - 6] (Ia = individual axis). In
this case the individual traversing of axes 1 - 6 is possible.
• The traversing velocity in [Hand]. Here the velocity is "100%" of the maximum
permitted velocity in Hand mode.
• The selected gripper-No. Here "Z1" = gripper No. 1.
• The tool number selected by using constant 400. Here it is tool 1.
Page:6-4
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Before you can traverse the robot, you must switch on the drive system.
Attention! Danger of being injured
The robot can undertake dangerous movements when the drive system is
switched on. Adhere to the instructions given in chapter 5 "Commissioning"
during the commissioning as well as after any modifications to the system have
been made.
In order to switch on the drive system, you must press both [Drive-ON] keys.
This combination of both keys prevents unauthorised switching on of the
robot.
Traversing individual axes
The basic robot axes (axes 1 - 3) and the Hand robot axes (axes 4 - 6) can
be individually traversed forwards using the axes traversing keys 1V - 6V or
R
F
1/6
traversed in reverse using the 1R - 6R keys. You can push several direction
keys at the same time. All of the selected axes will then traverse
simultaneously.
Attention! Danger of collisions
When you traverse the robot in the [Hand] operating mode, it is possible that
collisions between the robot and other devices will occur. Robots, tools, tool
pieces or other devices can be damaged or destroyed by a collision.
07.03.02
Elektroplanung-und Anlagenbau
Page:6-5
VRS 1
Traversing the additional axes
If additional axes have been integrated into the robot system, these can also be moved via
the axes traversing keys. To do this, change the axes traversing key assignments from axes
1 - 6 over to axes 7 - 12.
In order to change between axes 1-6 and 7-12 press the [Co-ordinates system]
key.
The 1st line of the screen will change from [Ia 1 - 6] to [Ia 7 - 12].
HAND – MODE
Ei7..12 100% Z01
F1 = TEACHING
Tool 1
F2 = MODIFY CONSTANTS
F3 = TEST
F4 = SERVICE PROGRAM
F5 = OVERVIEW
F1
F2
F3
F4
F5
The additional axes (axes 7 - 12) can be individually traversed forwards by using the axis
traversing keys 7V - 12V or traversed backwards with the 7R - 12R keys.
Cartesian traversing
"Cartesian traversing" means that the tool tip (TCP = Tool Centre Point) is moved within the
cartesian co-ordinate system area by either the joystick or the [Axis traverse] keys.
In order to carry out a cartesian traverse, the [Joystick] button must be held
down permanently. On the screen, the 1st line changes from [Ia 1 - 6]
(Ia = individual axis) to [BAS0WA] (global co-ordinates).
HAND –MODE BAS0WA 100% Z01
F1 = TEACHING
Tool 1
F2 = MODIFY CONSTANTS
F3 = TEST
F4 = SERVICE PROGRAM
F5 =OVERVIEW
F1
Page:6-6
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
When the [Joystick] key is pressed, the tool tip can be traversed using the joystick or the
axis traverse key in the X, Y or Z directions according to the selected traversing mode (se
below).
The key assignments for cartesian traversing are described in the "Cartesian
traversing using axes traversing keys and joystick" section in chapter 4 "Hand
console".
Selecting the traversing
You can select one of the following reference systems for the hand cartesian traversing (X, Y
or Z direction) of the tool tip:
♦ Global co-ordinates system "BAS0WA"
♦ Basic so-ordinates system "BAS1WA"
♦ Head co-ordinates system "HEADWA"
♦ Swivelling co-ordinates system "SWVLWA"
If the [Co-ordinates system] key is also pressed whilst the [Joystick] button
is being held down, another reference system will be selected. An example is
switching from "BAS0WA" to "BAS1WA".
HAND – MODE
BAS1WA 100% Z01
F1 = TEACHING
Tool 1
F2 = MODIFY CONSTANTS
F3 = TEST
F4 = SERVICE PROGRAM
F5 = OVERVIEW
F1
F2
F3
F4
F5
The fixed sequence is "BAS0WA" Î "BAS1WA" Î "HEADWA" Î "SWVLWA".
The significance of the "WA" (With Auxiliary inverse transformation) extension when used
with cartesian traversing is that the so called "Auxiliary inverse transformation" is switched
on. If the auxiliary inverse transformation is switched off, the "BAS0NE" (No Auxiliary inverse
transformation) heading will be displayed instead of "BAS0WA".
07.03.02
Elektroplanung-und Anlagenbau
Page:6-7
VRS 1
Further information regarding auxiliary inverse transformation can be found in the "
Auxiliary inverse transformation " section of chapter 14 "Modifying the constants".
Cartesian movement in BAS0WA global co-ordinates system
The global co-ordinates system is the fixed reference system for the robots. It is always
positions ("anchors") the foot of the robot (foundation plate). The orientation of the tools
remains constant during traversing in X, Y and Z directions.
Z
Y
X
O u tp u t p o sitio n
M o ve m e n t in X
p o s.
M o ve m e n t in Z
M o ve m e n t in Y
ne g.
Page:6-8
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Cartesian movement in BAS1WA basic co-ordination system
The basic co-ordination system lies with its origin in axis 1 (rotating area) of the robot. The X
/ Y levels are set by selecting the basic co-ordination system from the current position of the
revolving rotating area. The X direction now lies in the horizontal extension of the rotating
area from axis 1 to axis 2.
Cartesian movement in HEADWA head co-ordination system
The origin of the head co-ordination system lies in the tool tip. The tool orientation remains
constant when traversing in X, Y and Z directions. Z lays in the tool direction.
X
Z
Y
O u tp u t p o sitio n
M o ve m e n t in X
M o ve m e n t in Z
M o ve m e n t in Y
p o s.
ne g.
07.03.02
Elektroplanung-und Anlagenbau
Page:6-9
VRS 1
Rotating the tool tip (TCP) SWVLWA (PIVOWA)
The swivel traversing mode affects the specific tool settings (orientation settings), without
having to change the positioning of the tool tip (TCP) with regards to the tool piece.
X
Z
Y
O u tp u t p o sitio n
Z
X
Y
Ro ta tio n
X a xis = 6 0 d e g re e s
X
Z
Y
Ro ta tio n
Y a xis = - 6 0 d e g re e s
X=
Y=
Z=
rotating in the X axis
rotating in the Y axis
rotating in the Z axis
Page:6-10
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Incremental traversing
It is possible to traverse by increments in the above-mentioned coordinate systems.
]
The function is activated by pressing both of the [SHF] and [Coord.] function keys
at the same time:
H A N D – M O D E INC | BAS1WA 100%
Z01
F1 = TEACH – IN
Tool 1
F2 = MODIFY CONSTANTS
F3 = TEST
F4 = SERVICE PROGRAM
F5 = OVERVIEW
F1
]
F2
F3
F4
F5
Press the [Joystick]-key and then use the joystick or axis traversing keys to move
the tool tip in the X, Y and Z directions according to the type of incremental
traversing selected.
The bar display, which rotates when traversing, shows if the set step widths have been
achieved.
│
—
= Set step width achieved
= Prematurely interrupted
Please read the “130 Setting the incremental step widths” section in Chapter 14
“Modifying constants“ if you want to know how to set the incremental step widths.
07.03.02
Elektroplanung-und Anlagenbau
Page:6-11
VRS 1
Traversing velocity in hand mode
In the [Hand] operating mode the maximum traversing velocity is measured at the Hand
fitting plate and limited to 250 mm/sec. (i. a. w. DIN EN 775).
In order to give exact positioning details the traversing velocity for both for the Cartesian as
well as the axial traversing of the robot axes can be reduced down to 1%.
The respective current velocity factor is displayed in line 1.
HAND – MODE
Ei1 - 6 100% Z01
F1 = TEACH – IN
Tool 1
F2 = MODIFY CONSTANTS
F3 = TEST
F4 = SERVICE PROGRAM
F5 = OVERVIEW
F1
V
6/12 R
F2
F3
F4
F5
In order to modify the velocity factors when the drive system is switched off,
press the 6V or 6R hand console keys.
Velocity factors:
• Increasing
• Decreasing
Page:6-12
[6V]
[6R]
1 - 100 %
100 - 1 %
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Gripper functions
Use the gripper functions to operate the tools fitted on the robot's flange and linked via the
PLC, e.g.:
• Open or close the gripper,
• Activate the welding gripper,
• Control external devices (e.g. clamping devices).
A pre-requisite for the following chapter is that a gripper type assignment must be carried
out.
Please read through the "300 assigning the gripper“ section in chapter 14
"Modifying the constants" to learn how to assign the gripper types.
Pre-selecting the gripper-No.
Press the [Gripper+] key to increase the gripper-No. displayed on the screen
by 1, press the [Gripper-] key to reduce the number by 1.
Gripper functions [Gripper OPEN] and [Gripper CLOSED]
Pressing either [Gripper CLOSED] or [Gripper OPEN] keys affects the
control of the assigned output relays. The corresponding gripper function will
be
cleared via these relays.
For safety reasons an additional information screen describing the gripper movement about
to be executed will be displayed and an acknowledgement is required before the function can
be executed.
]
After pressing [Gripper OPEN] or [Gripper CLOSED] keys, the current menu will
be replaced with the gripper information text.
Z01
A T T E N T I O N ! Gripper functions
Gripper No.1 open
ZNGopen or F5 clears the movement
Open / Closed
F1
F2
F3
F4
F5
In this example, gripper-No. 1 has been selected and the [Gripper OPEN] key is activated.
]
If you do not wish to clear a gripper movement, press the [Esc] key. The previous
current menu will be re-displayed.
In the above example the gripper function is set to GRIPPER 1 = OPEN.
07.03.02
Elektroplanung-und Anlagenbau
Page:6-13
VRS 1
By pressing the [F5] function key or by pressing the [Gripper OPEN] key again the
[Gripper OPEN] function instruction is executed. The screen will change over to the
next executable function [Gripper CLOSED], which can be executed by pressing the
[F5] function key again. Consequently it is possible to "Toggle" between both gripper
functions. The respective output relay remains activated, provided that the [F5]
function key is still pressed down. After the key is released the output relay drops out
again.
$
This function execution can also be used for other pre-defined gripper.
]
Press [Gripper+] or [Gripper-] keys in order to change the gripper-No. (Z1 in the
above example) displayed on the screen.
The screen will be immediately updated and will now display the selected gripper-No.
Releasing the gripper function through a permanent signal
As opposed to controlling the output relay via a pulse from the [F5] function
key, [Shf] and [Gripper OPEN] or [Shf] and [Gripper CLOSED] key
combinations can also generate a permanent signal. The relay remains
permanently switched on.
]
After pressing [Gripper OPEN] or [Gripper CLOSED] keys the current menu will be
replaced by the gripper information menu on the screen.
Z01
A T T E N T I O N ! Gripper functions
Gripper No.1 open
ZNGopen or F5 clears the movement
Open / Closed
F1
F2
F3
F4
F5
Gripper-No. 1 is shown in this example and the [Gripper OPEN] key must be pressed.
]
If no gripper movement occurs, press the [Esc] key. The gripper information menu
will be terminated and the previous current menu will be displayed.
In the above example the gripper function is set to GRIPPER 1 = OPEN.
]
Press and hold down the [Shf] key and then additionally press the [Gripper OPEN]
key and the relevant output relay for this gripper function will be permanently
switched on.
Releasing the keys as well as the automatic switching over from the gripper information
menu to the current menu that follows does not effect the permanent switching status of the
relay!
Page:6-14
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Press the [Gripper OPEN] key in order to reset the permanent signal.
]
Press the [Gripper OPEN] key once again.
The gripper information menu will be displayed and the permanent signal for the
relays will be switched off. The gripper information menu will be automatically
switched to the current menu.
]
The same functionality is also valid for the [Gripper CLOSED] function.
07.03.02
Elektroplanung-und Anlagenbau
Page:6-15
VRS 1
Gripper text editor
This editor offers the opportunity to replace the standard text displayed in the gripper
information menu [Gripper No. xx open / closed] with an individual text entry.
The entered text can displayed together with help to differentiate between the eight possible
gripper numbers and their functions, especially when a gripper function is set up to control
another unit; e.g. feeder cylinder.
The newly entered identification is then displayed having a direct reference to the actual
function.
Example:
Z01
A T T E N T I O N ! Gripper functions
Gripper No.1 open
ZNGopen or F5 clears the movement
Open / Closed
F1
F2
F3
F4
F5
Z01
A T T E N T I O N ! Gripper functions
Work clearance stroke cylinder Z12 open
ZNG open or F5 clears the movement
Open / Closed
F1
F2
F3
F4
F5
Read the "Constant assignments for gripper" section in chapter 14 "Modifying the
constants" to find out how to enter the text.
Page:6-16
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Linking out the protection lattices
It is often necessary for the programmer, to remain inside the danger zone, to see the exact
point where a movement sequence starts during teaching or to learn where possible
collisions might occur in robot operating areas that are hard to see from the outside.
By adhering to the safety regulations in accordance with DIN EN 775, the programmer is
permitted to remain inside the danger zone for these reasons.
When working inside the danger zone, the robot drive system can only be switched on by
using the [Linking out protection lattices] instruction via the controller.
Proceed as follows:
] Inform all other personnel in your surrounding areas.
]
Select the [Hand] operating mode.
]
Link out the protection lattices using the "Linking out protection lattices" instruction.
]
Use the [Esc] key to acknowledge the "Switched to linking out of protection lattices"
report.
Attention! Danger of being injured
If a protection lattice has been linked out in the [Hand] operating mode, both
yourself and third parties have been placed in an especially dangerous situation.
Follow the safety instructions for the robot and the other devices.
]
You can now open the protection lattices.
07.03.02
Elektroplanung-und Anlagenbau
Page:6-17
VRS 1
Attention! Danger of being injured
The protection lattices must never be closed when personnel are working inside
the danger zone. This contravenes a basic principle in accordance with DIN EN
775 for the prevention of accidents. The personnel inside the danger zone can
be badly injured or killed. Lock the protection lattices in the open position so that
they cannot be closed.
]
If the protection lattices are open, have you hung up a warning sign that expressly
forbids the closing of the protection lattices and informs everyone that personnel are
working in the danger zone?
]
Whenever possible there should always be only one person in the danger zone of
the robot and a second person outside the danger zone must always remain in
visible contact with an EMERGENCY-OFF push button.
]
All personnel must be made aware of any imminent movements of the robots.
]
Make yourself familiar with the connected devices and follow the safety instructions.
Undertake everything that is mentioned in the safety instructions. Handle carefully
and conscientiously, so that no other people will be endangered.
]
If you have answered the above questions with "No", check the safety instructions
listed above once again.
]
Only in the case where you can answer the above questions with "Yes", are you
permitted to switch on the drive system by linking out the protection lattices.
Page:6-18
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
7. Programming sequences
7.
Programming sequences .................................................................... 7-1
The "Teaching" function ............................................................................... 7-3
New teaching ................................................................................................. 7-3
Editing ............................................................................................................ 7-3
Inserting ......................................................................................................... 7-3
Delete.............................................................................................................. 7-3
New teaching ................................................................................................. 7-4
Setting up a TCP............................................................................................ 7-5
Setting up a sequence................................................................................... 7-6
Entering a sequence-No................................................................................ 7-7
TCP teaching (point-No. 0)............................................................................ 7-8
Entering additional information ................................................................... 7-9
Teaching of other TCP's ............................................................................. 7-11
Finalising a sequence ................................................................................. 7-12
Interpolation methods ................................................................................. 7-13
PTP interpolation......................................................................................... 7-15
Linear interpolation ..................................................................................... 7-16
Swivel interpolation..................................................................................... 7-17
Circular interpolation .................................................................................. 7-18
Spline interpolation ..................................................................................... 7-20
MPG - interpolation...................................................................................... 7-21
Velocity profile............................................................................................. 7-22
Trajectory velocity Vb ................................................................................. 7-23
End velocity Ve ............................................................................................ 7-24
Start acceleration Aa ................................................................................... 7-25
End acceleration -Ae ................................................................................... 7-25
Filter (jerk) .................................................................................................... 7-26
Velocity profile for PTP ............................................................................... 7-29
Accuracy ...................................................................................................... 7-30
Accuracy of PTP points .............................................................................. 7-30
Accuracy of trajectory points ..................................................................... 7-31
Controlled corner creep .............................................................................. 7-33
Automatic reduction of the accuracy radius and the point end velocity 7-34
Weaving........................................................................................................ 7-36
Sensor functions ......................................................................................... 7-39
Commentary................................................................................................. 7-42
Search run.................................................................................................... 7-43
Co-ordinates display ................................................................................... 7-46
Modifying the displayed difference co-ordinates: .................................... 7-52
Setting up a sub-program ........................................................................... 7-53
Calling up a sub-program ........................................................................... 7-53
Example of an operating sequence with sub-program branching: ......... 7-54
Programming sub-programs ...................................................................... 7-54
Finalising sub-programs............................................................................. 7-55
Calling up a sub-program ........................................................................... 7-55
Sequences and sub-program overview ..................................................... 7-56
07.03.02
Elektroplanung-und Anlagenbau
Page:7-1
VRS 1
Page:7-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The "Teaching" function
The "Teaching" command encompasses all of the functions required for programming a robot
operating sequence. The following options are available for use:
New teaching
New teaching of sequences, sub-programs (S-P) as well as all associated additional
information.
Editing
The editing of individually programmed TCP's, sequences or S-P's; including the correcting
of completely programmed sequences and sub-programs as well as all associated additional
information.
Inserting
Inserting individual TCPs into previously programmed sequences and/or S-Ps.
Delete
The deleting of individual as well as several TCP's in a complete sequence, S-Ps and all
sequences in the entire system.
]
After selecting the [Hand] operating mode and pressing the [F1] function key, the
following menu will be displayed:
Hand->Teaching
Sequence : 1
Sp
:-
Ei 1 - 6 100% Z1
New
teaching
Edit
Insert
Delete
Directory
F1
F2
F3
F4
F5
The following will be displayed:
Line 1:
the selected operating mode, the selected velocity in manual mode, the
selected tool and the type of traversing.
Line 2 - 3:
the input fields for the sequence or S-P No.
Line 7 - 8:
function selection, press the relevant [F1] - [F5] function key in order to
branch to the required function.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-3
VRS 1
New teaching
Hand-F1
Here new teaching means programming the running of an operating sequence that can then
be run automatically.
An operating sequence can be programmed either:
♦ Online: (Teaching)
The robot axes will traverse to the teaching TCP if the axis traversing key is
pressed or the joystick on the hand console is activated. When the point is reached
the present positioning of each axis (co-ordinates) will be recorded and saved in
the controller. Consequently this point has then been defined (programmed) and it
will always traverse to this exact point anytime afterwards using the selected type
of traversing (interpolation).
♦ Offline:
The robot movement and the running of an operating sequence can be simulated
on the screen of an external CAD system. Afterwards the traversing program that
is being displayed can be transferred to the controller.
It is possible to use the following types of interpolation (trajectory methods):
• PTP (Point to Point)
• Linear
• Swivel
• Circular
• Spline
Additionally the points can also be assigned additional information, that sets,
• How to traverse to this point and
• What has to be carried out at this point.
The saving of the TCP co-ordinates as well as the entering of the necessary additional
information is made via the hand console.
You have the option of selecting and entering the relevant information via the clear text
displays (menus) in the hand console display.
Page:7-4
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
!
Before starting the new teaching, you must check without fail whether the
dimensions of the tools (grippers etc.) mounted on the robot flange must also be
measured and entered. Otherwise you will have a deviation in the trajectory
traversing.
Setting up a TCP
The following illustration gives an insight into the information that is internally saved by the
controller with regards to a TCP.
G e om e tric a linform a tio n
- C o -o rd ina te s in
ca rtesia n a xis a ng le
- Too l-num b er
Kinem a tic s info rm a tio n
- Sp ee d
- Prec ision
- A c ce lera tio n
- Filter, je rk
- Typ e o f inte rp o la tio n
To th e
n e xt
p o in t
Fro m
p re vio u s
p o in t
Pro c ess inform a tio n
- Se nso r
- W e a ve
- Se a rc h run
- G rip p e r info rm a tio n
- A na lo g ue o utp ut
- PLC inform a tio n
07.03.02
O rg a nisa tio na linform a tio n
- End id e ntifie r
- C hec ksum
- Jum p
- S-P
- W a iting tim e
- D o c um e nta tio n
Elektroplanung-und Anlagenbau
Page:7-5
VRS 1
Setting up a sequence
A sequence is the name given to a programmed robot-operating program. This is comprised
from a number of sequential, programmed TCP's, that can always be traversed with the
same accuracy in the [Automatic] or [Single Step] operating modes.
Each finalised sequence is identified by a sequence-No. (SEQ-No.) and is comprised of at
least two TCP's:
♦ Point 0 = start point
♦ Point n = last point in this sequence. This point must contain the additional "SE" =
sequence end information. This terminates the sequence.
Example of a sequence:
2
3
4
1
5
p a rt to b e p ro c e sse d
6 “SE”
Sta rt p o in t 0
2
1
Sta rt p o in t 0
Page:7-6
3
4
5
Ro b o t o p e r. se q u e n c e
p o in t 0 - 6
6 “SE”
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Entering a sequence-No.
Hand-F1
Before the TCP's can be programmed, the required sequence or S-P No. must be entered.
]
Select the [Hand] operating mode and press the [F1] function key.
The following menu will be displayed:
Hand->Teaching
Sequence : 1
Sp
:-
New
teaching
F1
Edit
F2
Ei 1 - 6 100% Z1
Insert
Delete
Directory
F3
F4
F5
The cursor blinks in the sequence input field.
]
Enter the required sequence-No. or S-P No. A maximum number of 127 sequences
are possible. Sequence-No. 0 is not permitted!
If you would like to obtain an overview of the previously programmed sequences and
S-Ps, go to the "Overview of sequences and sub-programs" section in this chapter.
]
Press the [F1] function key to go to the new teaching function.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-7
VRS 1
TCP teaching (point-No. 0)
Hand-F1-F1
The programming (new teaching) of sequence points using the controller is always carried
out in three steps:
• Traverse to the TCP
• Teaching of the co-ordinates (axis positioning)
• Enter additional information
] The following menu will be displayed after you have selected the new teaching
function:
Hand->Teaching->Nteaching Ei 1 - 6 100% Z1
Sequence : 1
Pnt :
0
Attention!:
Attention!:
Tool tip (K401) correct ?
Tool (K400) correct ?
COORDINATES
F1
F2
F3
F4
F5
Important information:
Before programming the 1st TCP's, the following must be checked without fail:
!
• Whether the correct tool-No. has been pre-selected for the current tool.
Read the information regarding constant 400 in chapter 14 "Modifying the
constants".
•
Whether the tool TCP has been correctly measured and entered.
Read the information regarding constant 401 in chapter 14 "Modifying the
constants".
]
Use the relevant [Axis traverse] key or the joystick to traverse the robot axes up to
the TCP, where you wish to start the teaching.
Refer to the information given in the "Programming Conventions“ section
in chapter 3.
]
Press the [F2] function key in order to record the position of the TCP's for the
teaching. The co-ordinates of the first TCP (point 0) have now been saved. The
screen will change so that it is ready for the entering of the additional information.
Page:7-8
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F1-F2
Entering additional information
] The following menu will be displayed after the controller has recorded the coordinates for the points:
Hand->Teaching->Nteaching Ei 1
Sequence : 1 Pnt : 0
PTP
Vb:
100 %
Ve:
Aa:
100 %
Ve:
Jerk:
100 %
Toler:
PLC
---
F1
COORDI- InterNATES polation
F2
- 6 100% Z1
0
100
0
S/S-P
end
F3
F4
%
%
1/10 deg
Continue
F5
The following additional information is displayed in the 1st menu level and can be edited if
necessary:
Line 1:
the selected function (new teaching)
Line 2:
the selected sequence-No.(1), current point-No. (0), interpolation method
(default is PTP)
Line 3 - 5:
Input fields for the velocity profiles
Line 7 - 8:
Vb
Ve
= trajectory velocity
= End velocity
Aa
Ae
Jerk
= Acceleration
= Braking delay
= Filter value for accelerating and braking
Toler.
= Accuracy
Function key assignments:
F1
= PLC functions
(this branches to a menu for entering PLC functions)
F2
= co-ordinates
(the current co-ordinates that have been saved for the next point
will be deleted)
F3
= Interpolation
(this branches to a menu for entering the interpolation method)
F4
= S/S-P end
(for entering the "End identifier")
F5
= Continue onto the 2nd level of this menu.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-9
VRS 1
PLC-information:
The four positions beneath the PLC menu entries (4 plus or minus signs) give a quick
summery of the previously programmed PLC functions
•
S P•
S
- -
S P
S +
+ +
Programmed PLC functions
Sub-programs (SP) are programmed
Jump condition (JC) is programmed
Travers condition (FB) is programmed
]
Use the [F5] function key to reach the 2nd menu level for additional information for
further inputting opportunities.
Hand->Teaching->Nteaching Ei 1 - 6 100% Z1
Sequence : 1 Pnt : 0
PTP
S-P connection :
Tool
:
Kinematics
:
Weave
F1
1
0
Sensor Comment. Search
F2
F3
Co-ord
Display
F4
F5
The following are displayed in the 2nd menu level:
Line 1: the selected function (here: new teaching)
Line 2: selected sequence-No. (1), current point-No. (0)
Line 4: the sub-program number.
The programming of a sub-program connection is carried out in the PLC.
Read the "PLC programming" chapter for more information regarding this.
Entries can be made in:
Line 5: the relevant tool-No. (1 - 7) for the current point.
Read the information regarding constant "Setting the 400 tool for teaching" in
chapter 14 "Modifying the constants".
Line 6: only for kinematics-No. special applications
Read the description regarding constant "464 kinematics in the operating mode
manual" in chapter 14 "Modifying the constants".
Line 7,8: F1 - F5 function key assignments:
F1
F2
F3
F4
F5
=
=
=
=
=
Page:7-10
Weave
Sensor
Commentary
Search run
Co-ordinates display
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Press the [Esc] key after you have entered all of the necessary additional
information. This will return you to the 1st menu level.
The teaching of the next TCP can now be made.
Teaching of other TCP's
After you have entered the additional information, you can program another point.
]
Traverse the robot up to the next TCP to be programmed and press the [F2]
function key. This will import the co-ordinates of the new point and at the same time
the previous point together with the entered additional information will be finalised
and automatically saved.
The following screen will be displayed:
Hand->Teaching->Nteaching Ei 1 - 6 100% Z1
Sequence : 1 Pnt : 1
PTP
Vb:
100 %
Ve:
100 %
Aa:
100 %
Ve:
100 %
Jerk:
100 %
Toler.:
100 1/10 deg
PLC
---
F1
COORDI- Interpolation
NATES
F2
F3
S/S-P
end
Continue
F4
F5
Now the new point-No.1 (corresponds to the 2nd programmed point of this sequence) will be
displayed. It will automatically import the additional information (acceleration value, velocity
etc.) from the previous point as the defaults.
Exceptions are:
• Weaving
• Sensor command
• Search run
• Commentary
• PLC functions
]
Check whether the previously entered additional information is also valid for this
TCP. If not, the corrections should be made now.
]
If no modifications are necessary, traverse onto the next point and afterwards press
the [F2] function key to save the settings.
]
Repeat this step until all of the points in the sequence have been programmed.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-11
VRS 1
Finalising a sequence
Each programmed sequence must be finalised with an SE (sequence end) end identifier
instruction.
The relevant additional information sequence end is programmed into the last of the
programmed TCP!
]
If the co-ordinates and the relevant additional information for the last TCP have
been programmed the end identifier instruction can now be entered by pressing the
[F4] function key.
The relevant SE additional information will be displayed in addition to the previous
text on the screen.
Hand->Teaching->Nteaching Ei 1 - 6 100% Z1
Sequence : 1 Pnt : 6
PTP
SE
Vb:
100 %
Ve:
0
%
Aa:
100 %
Ve:
100 %
Jerk:
100 %
Toler.:
100 1/10 deg
PLC
---
COORDI- InterNATES polation
F1
F2
F3
S/S-P
end
F4
Continue
F5
]
Press the [Esc] key to exit the teaching function. Afterwards the last sequence point
and the entire sequence will be finalised and saved to the RAM disc.
]
The end identifier instruction that was entered by pressing the [F4] function key as
mentioned above can be removed by pressing the this function key once again. The
additional SE information entry will be deleted or it can be reset.
“SE”
Start
Page:7-12
End
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Interpolation methods
The type of trajectory between two programmed TCP's is set up with the help of the
interpolation method. Interpolation means: calculating the intermediate steps.
The controller generates the trajectory profile between two programmed TCP's with the help
of the trajectory module, this is calculated in the so-called "trajectory interpolation point". This
interpolation point is re-calculated for each traversing of the trajectory and is not saved in the
controller or provided with a point number.
The controller offers the following interpolation methods:
PTP
Point To
Point
LIN
Linear
Actual path
of the TCP
Point
Interpolation cycle
PIVO
(SWVL)
Swivel
CIR
Circular
SPL
Spline
MPG
Multipoint
geometry
10
8
6
1
07.03.02
2
3
4
7
5
Elektroplanung-und Anlagenbau
Page:7-13
VRS 1
The entered interpolation method is displayed with teaching:
Hand->Teaching->Nteaching Ei 1 - 6 100% Z1
Sequence : 1 Pnt : 10
PTP
Vb:
100 %
Ve:
100 %
Aa:
100 %
Ve:
100 %
Jerk:
100 %
Toler.:
100 1/10 deg
PLC
---
F1
COORDI- InterNATES polation
F2
F3
Seq/S-P
end
Continue
F4
F5
The default interpolation method is PTP.
]
]
After pressing the [F3] function key, the following assignments for the [F1] - [F5]
function keys will be displayed:
LIN
Swivel
CIRS
CIRE
Cont.
F1
F2
F3
F4
F5
After pressing the [F5] function key other interpolation methods may be selected.
ABST
SPL
MPG
F1
F2
F3
Cont.
F4
F5
The function key abbreviations have the following significances:
PTP
=
Point-To-Point interpolation
LIN
=
Linear interpolation
SCHW(PIVO) =
Swivel interpolation
CIRS/CIRE
=
Circular interpolation
SPL
=
Spline interpolation
ABST
=
MPG
=
Absolute traversing (only used with special systems. No further
description is given in this manual)
MPG Multi-point geometry
]
After pressing the respective function key the additional information for the relevant
interpolation method will be assigned to the listed TCP's and displayed on the
screen.
Page:7-14
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
PTP interpolation
PTP interpolation (Point-to-Point) enables fast traversing from the destination points. This
interpolation method offers the fastest method of moving between two programmed points.
The trajectory control simultaneously traverses the individual robot axes to each of the
programmed angle differences without taking into account the TCP-co-ordinates and the tool
orientation. Here the individual axes movements are calculated so that all axes traverse
simultaneously and also stop at the next TCP simultaneously (SYNCHRO PTP). The
duration of the traversing period to the next programmed TCP's is dependant on the slowest
axis.
Attention! Danger of collisions!
When programming the traversing path to the TCP's you must take into
consideration that due to the respective axis settings of the robot that the tool
will move, as set by the controller, in a crooked trajectory between the start and
destination points whilst each axis is traversing the direct path to the destination
position. (e.g. when the robot axes are in an elongated position).
Example:
Actual traversing path for programmed path A - B with almost elongated axes.
A
07.03.02
B
Elektroplanung-und Anlagenbau
Page:7-15
VRS 1
Linear interpolation
When linear interpolation is being used the robot tool tip moves along a straight trajectory in
the area.
Due to the co-ordinated, simultaneous setting of several axes, the movement of the tool tip
TCP (Tool Centre Point) is steered along a straight line within the area. The orientation of the
tools within each trajectory section is set up via the direct linear path, so that the destination
point can be reached using the programmed orientation.
The method of traversing is required when linear movements together with defined velocities
are to be programmed; e.g. for trajectory welding or spreading adhesive.
In addition this interpolation method is used for traversing away from the destination
positions that cannot be used with PTP interpolation due to the danger of a collision
occurring.
B
A
Th e (inte rp o la tio n ) p o int
b e tw e e n TC P A a n d B
is c a lc u la te d fro m
th e tra je c to ry m o d ule .
If a LIN point has to be programmed, check the trajectory module, to see whether it can be
traversed linearly to this point.
If this is not possible, (e.g. the TCP to be traversed to lies on a straight path that will be
crossed by the robot) the following error message will be displayed:
Error checking the trajectory! Trajectory not possible!
Remedy:
Shift the TCP or re-program it as a PTP point.
Page:7-16
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Swivel interpolation
Selective tool twisting can be programmed with the swivel interpolation method, without
having to modify the position of the TCP.
Example: Swivelling process using an adhesive pistol
Tool tip
TCP
Tool piece
Programming:
In the above example any interpolation method can be selected for point P1. Point P2 is
programmed with the new orientation that is required and the swivel interpolation method.
The TCP (e.g. the tip of the adhesive pistol) should remain in the P1 and P2 point positions
with regards to the tool piece.
Program run:
If swivelling has been programmed in TCP P2, the robot will stop at TCP P1, execute the
pre-entered swivelling movement and then start the program (sequence) with the modified
tool orientation at point P2.
Application:
Swivels are always programmed when the tool setting cannot be executed within the path to
be traversed or because of the programmed traversing velocity. A good example would be
the new orientation of an adhesive pistol in the corner of a component.
!
Take into consideration:
that if the tool tip is moved away from a fixed TCP during swivelling, the previously
entered tool offsets must be checked and corrected accordingly.
Read the information regarding constant "401 tool TCP measuring" in chapter
14 "Modifying the constants".
07.03.02
Elektroplanung-und Anlagenbau
Page:7-17
VRS 1
Circular interpolation
Due to the use of circular interpolation, the individual axes will be continually set up so that
the tool tip (TCP) together with the setting up of the tool orientation will describe a circular
segment in the area.
As opposed to the other interpolation methods, at least two points following one after the
other must be programmed using the "Circular" interpolation method for a circular shaped
movement. Only then can you enter three TCP's together with the last point for the circular
trajectory that will clearly set up a circle in the area.
Point 1: Starting point
This point is the last part of the previous trajectory and can be traversed to using any
interpolation method.
Point 2: Circular interpolation point (circular interpolation point = CIRS)
This point is programmed between the start and end points of a circular segment. It is
displayed together with a CIRS (circular interpolation point) interpolation identifier and is
used by the trajectory module for calculating the circular geometry.
Attention!
The angle between the start point and the interpolation or the interpolation point and the end
point must be less than 180 degrees, as otherwise an error will occur in the orientation
setting up!
Point 3: Circular end point (circular end point = CIRE)
This point forms the end point of a semi-circle or circular segment and is displayed together
with the CIRE interpolation identification.
Page:7-18
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
!
Information:
Due to the angle difference being less than 180° another interpolation point and an
end point are also required when programming a complete circle. Naturally an end
point must always follow the programmed interpolation point.
Example: CIRS - CIRE - CIRS - CIRE.
Programming a circle segment
CIRE end point
CIRS interpolation point
Next point
(LIN – PTP – SWVL - CIRS)
Start point
Programming a semi-circle
CIRS interp. point
smal. than 180°
Start point
(LIN – PTP – SWVL – CIRS)
Next point
(LIN – PTP – SWVL - CIRS)
CIRE end point
Programming a full circle
Start point
(LIN – PTP – SWVL – CIRS)
Next point
(LIN – PTP – SWL – CIRS)
!
Information:
After finishing the circular shaped movement it must be taken into consideration that
the automatically imported interpolation method must be corrected for the next point, in
case it is followed by another circular trajectory.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-19
VRS 1
Spline interpolation
The "Spline" command is a mathematical identification for a continuous area curve that
connects a row of TCP's together. This enables trajectory shapes to be realised that cannot
be described by linear paths and circular sections.
Any type of
interpolation
To verify a linear trajectory
Remarks:
The entering of the accuracy (in mm) will produce an accuracy ball at this point, but this does
not have an effect on the spline shape. It simply effects the activation of the PLC functions
that have been programmed for this point, as soon as the TCP enters the accuracy ball.
Programming conventions for spline interpolation
• the 1st point in a sequence can not be a spline point
• no tool changes are permitted in a spline point
• a sub-program jump is not allowed in a spline point
A trajectory check using linear interpolation must be carried out when programming spline
points. A disadvantage of this type of check is that exceeding the axis limits (software limits)
during a teaching or making corrections will not be recognised if the TCP's are programmed
right on these limits!
Symmetrical spline
You should be aware that a symmetrical spline function can also be selected as the control.
This contains the same trajectory traversing for Single Step FORWARDS and Single Step
REVERSE.
Page:7-20
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
MPG - interpolation
Sequences, with any point spacing, can be run by implementing this type of interpolation.
Regrinding of the individual points is possible. Leave any contours which are described by a
level in the area and any which can be repositioned in the area, can therefore be run. The
contour settings are made when the NC-data is converted.
The point coordinates are saved as an ASCII-file in RAM.
Advantage:
Considerable reduction in the teach expenditure
Area of application:
Test systems
Laser cutting devices
Z
Y
6
7
8
5
4
2
3
1
0
X
Further information can be found in the PP – V 401 electrical and system construction
drawings
07.03.02
Elektroplanung-und Anlagenbau
Page:7-21
VRS 1
Velocity profile
The velocity profile defines the movement dynamics of the TCP's during traversing between
two programmed TCP's. An optimum velocity profile enables the robot to undergo a
continuous and non-jerking traversing process during a velocity change (e.g. traversing or
braking).
The calculation of the profile is dependant on the so called main reference input variable
(generated by the controller) as well as the profile parameter which is individually
programmable for each trajectory segment.
Depending on the interpolation method, the main reference input variable is calculated from
the:
• Angle difference of the axis co-ordinates (PTP)
• Path, that the TCP must cover between the points on the respective trajectory
(circular or linear) (CIR / LIN)
• Angle difference of the orientation vectors (SWVL)
The profile parameter is entered as additional information during the programming.
Trajectory velocity Vb
End velocity
from previous
point
point 7
point 6
Vb
Ve
Aa
Ae
Filter (jerk)
=
=
=
=
=
Page:7-22
trajectory velocity of the TCP
end velocity when reaching the destination point
start acceleration
end acceleration (braking delay)
transfer matching
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The 6th parameter, the start velocity (Va), does not have to be additionally programmed, as it
is always used as the connecting condition for two consecutive profiles, i.e. the point end
velocity (Ve) programmed in the TCP that has just been reached is also used as the start
velocity for traversing onto the next point.
If Ve = 0 the movement in the destination point will be stopped for a short time and it will then
traverse on to the exact point.
During the programming, the controller automatically generates the default value or uses the
value from the previous point.
Trajectory velocity Vb
The trajectory velocity Vb is the velocity required to traverse the TCP's between two
programmed points and is generated by the controller.
Trajectory velocity Vb
End velocity
from previous
point
point 7
point 6
After the acceleration phase the TCP will be traversed along the programmed trajectory at
the constant selected trajectory velocity Vb.
The trajectory velocity must be specially adapted for each application.
If the trajectory velocity is too fast, it is possible that it will not reach the destination point due
to the necessary acceleration phases or the rotational limits of some axes.
The trajectory velocity is entered in mm/sec.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-23
VRS 1
End velocity Ve
The end velocity Ve is the velocity required to traverse the TCP's to the destination point of a
trajectory and is generated by the controller.
End velocity Ve
from
last
point 1
Traject. 1
point 2
Traject. 2 to
next
point 3
Just before it reaches the destination point (P2 in the example above) the velocity of the
TCPs will be braked to the programmed end velocity by the selected delay (Ae). It will then
traverse to the destination point at velocity Ve. The end velocity Ve that has been
programmed into the TCP that has just been reached is also used as the start velocity Va for
traversing onto the next point.
If Ve=0 the movement in the destination point will be stopped for a short time and it will then
traverse on to the exact point. If it does not have to brake at the destination point, the end
velocity should be set so that it is the same (Ve=Vb).
The end velocity is entered in mm/sec.
Page:7-24
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Start acceleration Aa
The start acceleration is effective, when a different trajectory velocity has been programmed
between two TCP's.
The start velocity is generated by the controller using the default value and normally does not
need to be modified.
Start acceleration
small
large
trajectory velocity
trajectory velocity
A low start velocity means that it will slowly attain the programmed trajectory velocity.
Advantage:
Disadvantage:
the traversing is smoother and quieter.
If the selected acceleration is too slow, then under these
circumstances the trajectory velocity will not be reached!
If the velocity is too fast, this can result in a lag error due to the mechanical inertia of the
axes. The start velocity Aa is entered in mm/sec2.
End acceleration -Ae
This negative acceleration (braking delay) normally affects the braking end of the previous
traversing trajectory velocity, in order to traverse up to the TCP at the programmed point end
velocity Ve.
Should the point end velocity Ve be faster than the present trajectory velocity, -Ae can also
have an accelerating effect.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-25
VRS 1
The end acceleration velocity is generated by the controller using the default value and
normally does not need to be modified.
End acceleration
small
large
trajectory velocity
trajectory velocity
Ve = the end velocity that must be reached in the TCP.
A high end-acceleration velocity will result in fast and hard traversing to the destination
points, which worsens the running quietness of the equipment.
A low end-acceleration results in smoother but slower attaining of the programmed point end
velocity Ve. The end acceleration Ae is entered in mm/s2.
Filter (jerk)
The filter function indicates a transient response that has been produced by a change in
velocity, e.g. when traversing from a stop position or the importing of a start velocity into the
programmed trajectory velocity and in reverse.
The setting of the filter function should ensure a smooth, i.e. 'jerk-free', transient response.
Trajectory velocity
filter
Page:7-26
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
!
The pre-entered default value (100%) for the filter function is the optimum setting
for the robot and you are not permitted to modified it, as this could result in a
defect occurring with the robot mechanics.
Should a correction be required in individual cases, the following example shows which
effects must be calculated for:
Example:
Modifying the velocity profiles via the filter function (here, acceleration Aa is the same for
both profiles).
Filter
Filter (jerk) <<100%
Filter (jerk) >>100%
07.03.02
=
=
jerky traversing process with overshooting
slow and creeping traversing process
Elektroplanung-und Anlagenbau
Page:7-27
VRS 1
The following illustration shows a complete overview of the kinematic correlation of the TCP
movement:
Traversed path
TCP velocity
Acceler.
Jitter (filter function)
Page:7-28
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Velocity profile for PTP
If there are deviations from the trajectory traversing, the velocity profile for PTP does not
describe the velocity of the TCP's in the area, but the axis traversing velocity of the individual
axes.
The controller calculates the velocity profiles so that at least one axis traverses at the
programmed maximum velocity and at least one axis traverses with the maximum
acceleration and braking delay value. This can also cover different axes. The parameter for
velocity and acceleration is entered in % for PTP traversing and also covers the maximum
velocity or maximum permitted acceleration.
Example: velocity profile PTP
Tra je c to ry ve lo c ity
V
Vb
Filte r
Aa
End ve lo c ity fro m
p re vio us p o int
Sta rt
a c c e le ra tio n
-Ae
End a c c e le ra tio n
Va
Va
Sta rt
ve lo c ity
Ve
End ve lo c ity
t
Po int 6
Po int 7
Programming example: Vb = 100% Aa = Ae = 100 %.
With these values entered, axis 1 can accelerate at 100 % and be braked, but will only
traverse at 70 % of its maximum velocity, where as axis 6 will be driven at only 30 % of its
maximum acceleration, but will attain 100 % of its maximum velocity.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-29
VRS 1
Accuracy
The pre-entered accuracy defines the trajectory traversing within the accuracy-ball. The
greater the accuracy, the closer it will be traversed to the relevant point. The accuracy does
not describe the accuracy of the programmed trajectory, but simply lays down the fixed
trajectory within an accuracy ball. The radius of this ball is the accuracy parameter.
This function is used in order to:
• Optimise the timing of PTP movements
• Enable the traversing of linear trajectories to be controlled at constant velocities in
corner points (corner cutting).
The accuracy is entered as additional information in each TCP.
Accuracy of PTP points
The accuracy of PTP points is entered in 1/10 degree (axis angle) via a tolerance value. With
PTP the accuracy is achieved, when the axis having the longest traversing path has reached
its destination on the entered degree (tolerance value).
With absolute accuracy (accuracy = 0 in 1/10 degrees) only the system specific deviations
will be allowed.
In order to optimise the timing of robot traversing programs (cycle time optimisation) an
accuracy ball can be programmed into the points that can be traversed to without absolute
accuracy. If a value > 0 is selected for the end velocity Ve, the robot will not stop at the point
but will creep onwards to the next programmed TCP.
Hand->Teaching->Nteaching Ei 1 - 6 100% Z1
Sequence : 1 Pnt : 10
PTP
Vb:
100 %
Ve:
100 %
Aa:
100 %
Ve:
100 %
Jerk:
100 %
Toler.:
100 1/10 deg
PLC
---
F1
Page:7-30
COORDIInterpolation
NATES
F2
F3
S/S-P
end
F4
Continue
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Accuracy of trajectory points
The precise traversing at a constant velocity of the programmed trajectory points in which a
change of direction must be made (e.g. a corner) is frequently influenced by the mass inertia
of the robots and the lag error of individual axes.
The abrupt direction changes encountered in a corner point can result in the robot traversing
outside of the point (overshooting into the next trajectory).
The controller can combat this uncontrolled process by using the "Controlled corner creep".
The specific creep area can be defined in the corner point in the form of a so-called accuracy
ball.
The great advantage of the creep process lies in the fact that the corner point no longer has
to be traversed precisely. The initial use of the high accuracy three-dimensional curve
(circular and spline) enables an exact traversing of the trajectory point at the programmed
velocity.
Application:
Controlled creep using the accuracy ball:
TCP to be
traversed to
End of creep
Accuracy radius
Start creep
Accuracy ball
]
The accuracy for trajectory points is entered in mm. This value corresponds to the
radius (r) of the accuracy ball (creep radius).
]
If the end velocity Ve = 0 is set in conjunction with the accuracy also being set to
"0", the TCP will be traversed precisely.
]
If a value greater than zero is first entered for the accuracy and the end velocity, the
specific point creeping will be carried out as described.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-31
VRS 1
The accuracy radius for linear and circular interpolation is entered in mm:
Hand->Teaching->Nteaching Ei1
Sequence : 1 Pnt : 10
LIN
Vb:
1666 mm/sec
Ve:
Aa:
2300 mm/sec2 Ae:
Jerk:
100 %
Toler.:
PLC
---
F1
COORDI- Interpolation
NATES
F2
F3
- 6 100% Z1
1666 mm/sec
2300 mm/sec2
100 mm
S/S-P
end
F4
Continue
F5
The swivelling accuracy radius is entered in degrees (orientation):
Hand->Teaching>Nteaching Ei1 - 6 100% Z1
SWVL
Sequence : 1 Pnt : 10
Vb:
200 dg/sec
Ve:
200 dg/sec
Aa:
800 dg/sec²
Ae:
800 dg/sec²
Jerk:
100 %
Toler.:
100 deg
PLC
---
F1
Page:7-32
COORDI- Interpolation
NATES
F2
F3
S/S-P
end
F4
Continue
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Controlled corner creep
The controlled corner creep is applied in practise, when a constant velocity is required in a
corner point or a specific corner has to be rounded.
The controlled corner creep can be basically determined by the following parameters:
• Accuracy radius r
• Point velocity Ve
Example: spreading adhesive
accuracy
r = 20 mm
accuracy ball
accuracy
r = 20 mm
adhesive track
programmed point
The accuracy radius r defines a three-dimensional ball for the programmed creeping to the
point and is entered in a single dimension, which corresponds to the interpolation method
which will be used to traverse to the point.
PTP
=
LIN, CIR
=
SWVL (PIVO) =
r in axis angle degrees
r in mm
r in orientation degrees
The programmed trajectory velocity Vb will be reduced to the programmed end velocity Ve
when the accuracy ball is reached. If the TCP exits the accuracy ball, it will accelerate up to
the newly programmed trajectory velocity.
Trajectory velocity
start
creep
end of
creep
from traject. 1
last
point
traj. 2
to
next
point
accuracy ball
07.03.02
Elektroplanung-und Anlagenbau
Page:7-33
VRS 1
The programmed end velocity Ve is used as the velocity of the TCP's within the accuracy
ball.
The point related PLC will always be started when the TCP's enter the accuracy ball and the
programmed commands will be processed.
The point velocity Ve is calculated from the programmed trajectory velocity Ve for traversing
to the TCP, multiplied by the entered traversing velocity (1 - 150 %) in the Single Step and
Automatic operating modes.
Creep at Ve>0
No creeping at Ve=0
TCP to be
traversed to
TCP to be
traversed to
accuracy ball
accuracy ball
end of
creep
accuracy
radius
end of
creep
accuracy
radius
start of the point
related PLC
start of the point
related PLC
start creep
If Ve = 0 the creeping will not be activated, it will traverse exactly to the point. If an accuracy
ball has been defined at this point, it is possible that only the programmed point related PLC
will be activated when it enters the ball.
Automatic reduction of the accuracy radius and the point end velocity
The controller automatically reduces (never enlarges) the programmed accuracy radius
and/or the point velocity, if:
]
The point end velocity Ve = 0
]
The accuracy radius was too large when it was originally entered or the radius
exceeds 45 % of the path length to the next point.
!
With PTP points the radius on the path will be reduced, so that it can be used as
the braking path for the traversing velocity.
The accuracy radii of two consecutive points must not overlap. For this reason the accuracy
radius is automatically reduced to a maximum of 45 % of the path length between the two
points.
Page:7-34
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Example:
- Linear interpolation from point A to B
- Path length from A to B = 200 mm
- Programmed accuracy radius r = 120 mm
- Automatic reduction of the radius to 45 % of the path length r = 0.45 x l = 0.45 x 200 = 90
mm
The automatic reduction of the accuracy radius invokes a reduction in the point end velocity
Ve at the same time.
If the accuracy radius at point B is reduced because of the 45 % criterion, the point end
velocity will also be reduced by the same factor.
Example:
Programmed radius:
Programmed point end velocity:
Path length:
r = 120 mm
Ve = 100 mm/s
A - B = 200 mm
Factor for reducing the accuracy radius:
Factor = path length x 0.45 = 200 x 0.45 = 90%
The reduced point end velocity is calculated as follows:
Ve (red) =
Programmed Ve x factor
= 100 x 0.9 = 90 mm/sec.
In addition to reducing the accuracy radius (and the point velocity) at point B due to the path
length A Ö B, both values can be reduced again due to the path length B Ö C.
You can read about the reduction of the accuracy ball in the Single Step mode, depending on
the velocity override setting, in chapter 14 "Modifying the constants".
07.03.02
Elektroplanung-und Anlagenbau
Page:7-35
VRS 1
Weaving
New teaching F5-F1
Weaving corresponds to an adjustable, swivelling (oscillating) movement that must be
imposed (weave trajectory) on a programmed trajectory (linear or circular).
Application areas:
• Welding
• Applying adhesive
• Coating with varnish
Weaving methods:
• With all axes
• Only with hand axes (axes 3, 4 and 5)
w ith h a n d a xe s
]
w ith a lla xe s
The weave menu can be displayed during the entering of the additional information
for new teaching or for correcting by pressing the [F5] and [F1] function keys:
Hand->Teaching->NTEACHING Ei1 - 6 100% Z1
SEQUENCE : 33
Pnt: 2
Weave parameter
Shape
0 :
no weaving
Amplitude
0 :
[ in 1/10 mm]
Period
0 :
[ in 1/10 mm]
Opening
0 :
[ in 1/10 mm]
Plane
0 :
[ in 1/10 mm]
F1
Page:7-36
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Use [Cursor Up] and [Cursor Down] keys to move the cursor to the respective
input field.
]
In order to select the required type of weaving, the relevant number must be entered
in the "Shape" input field:
0:
1:
2:
3:
4:
no weaving
SINUS weaving shape for all axes
SPIRALE weaving shape for all axes
SINUS weaving shape for manual axes
SPIRALE weaving shape for manual axes
Sp ira lw e a ve
Sinus w ea ve
w itho ut a sym m e tric s
Sinus w ea ve w ith
a sym m etric s (= 90°)
A
A SY = 90°
A
A
P
A
O
P
A =
O =
P=
A SY
!
P
A m p litu d e
O p e n ing
Pe rio d
= A sym m e tric
Information:
When a weave function is imposed on a programmed trajectory the original feeder
velocity above the tool piece remains constant. The actual velocity of the TCP's
must be drastically increased due to the shape and size of the weaving function.
]
Enter the amplitude and period parameters, with which the dimensions of the
weaving shape can be described (see above illustration).
]
With the SPIRALE weaving shape, the opening of the spiral must be additionally
entered.
]
With the SINUS weaving shape, the asymetrics for the sinus function can be
entered at the opening position.
By shifting the symmetric axis you can make the TCP wait for a longer time on one side of
the weaving shape. This function can be used, for example, for butt-welding of two plates
having different thickness'.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-37
VRS 1
]
Use the "Plane" parameter to twist the weaving level by the entered ϕ angle (in 1/10
degree). If no entry has been made (plane = 0), the weaving level will lie parallel to
the flange of the manual mounting plate. If a tool orientation is entered, the weaving
level lies vertically to the tool direction.
]
After pressing the [Esc] key, the entered data will be imported from the controller
and you will exit the menu.
Page:7-38
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
New teaching F5-F2
Sensor functions
Up to 4 different sensor functions can be programmed in each programmable TCP using the
controller:
•
•
•
•
Sensor on
Sensor off
Sensor path
Sensor point
Depending on which sensor module is being used, the sensor functions can be used for up
to a maximum of 15 different sensors. A sensor module is a software module specially set up
for a sensor application. This can be is reloaded by the controller.
Read the "421 loading sensors" section in chapter 14 "Modifying the constants" for
more information regarding this:
Up to 32 sensor flags (S1 - S32) can be processed according to the respective sensor
module. They can accept the logical 1 or 0 statuses and these can be handled in the same
way as inputs in the PLC. Their significances can be found by using the special sensor
module.
Read the accompanying sensor documentation for the sensor module being used.
$
After selecting the new teaching main menu and pressing the [F5] and [F2] function
keys, the following screen will be displayed:
Hand->Teaching->NTEACHING Ei 1 - 6 100% Z1
SEQUENCE : 33
Pnt: 2 SENSOR
Command:
Command:
Command:
Command:
RESET
F1
COMMAND SENS.NO DELETE.
F2
F3
F4
F5
The current sequence-No., point-No., and the input field for the sensor command are
displayed.
[F1] = RESET
Use this function key to bring the cursor to the required input line.
[F3] = COMMAND
Pressing the [F3] function key changes the assignments of the [F1-F5] function keys.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-39
VRS 1
[F4] = SENSOR-NO
With this function key you can position the cursor on the input field for the Sensor-No.
Then enter the required No.
[F5] = DELETE
Use this function key to delete the entire command line indicated by the cursor!
Proceed as follows in order to program a sensor function:
]
Use [F1] function key to select the required command line.
]
Press the [F3] function key. The function key assignments will be changed and the 4
sensor functions will be displayed.
]
ON
Path
Point
OFF
F1
F2
F3
F4
F5
Pressing the [F3] function key changes the assignments of the [F1-F5] function
keys.
The sensor functions have the following significances:
[F1] = ON
The "SWITCH ON SENSOR“ text is displayed in the current command line. This
command is necessary as many sensors, especially the more complex types, require
a switching sequence. If the "SENSOR ON" command is programmed in a TCP, then
the controller will send a switching sequence to the sensor, which will be set during
the parameterisation.
For example purposes, a programmed sub-program can be activated for this.
The "SENSOR ON" command should be programmed to be at least 3 points in front
of the actual sensor points, in order to guarantee a safe initialisation.
[F2] = PATH
Identifies the path between the current TCP (with 'Path' sensor command) and the
previous point. The sensor signal will be evaluated at each interpolation step and the
trajectory corrected accordingly.
A typical example of these "Online sensors" is a velocity sensor, which can influence
the current trajectory velocity between two points. (Tracking)
[F3] = POINT
As opposed to the sensor path, the sensor data will not have an effect on the path
between two points, but in the actual TCP.
As an example we can take an image processing system, which shifts the
programmed TCP in the direction of known parts.
Page:7-40
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
[F4] = OFF
The programming of 'SENSOR OFF' has a resetting effect on the respective sensor.
This command can be implemented in order to reset sensors that require such a reset
pulse before a new action or a parameter modification.
When this additional information is recognised a sub-program in the sensor interface
program module can also be activated.
If a "SENSOR OFF" command is given, a "SENSOR ON" command must first be
programmed before any further sensor actions can be made.
]
After the relevant sensor function has been selected, it will be displayed in the
current command line.
]
Press the [F4] function key in order to enter the sensor-No.
]
Confirm the entry by using the [Return] key.
]
You can program 4 sensor functions to each TCP. The commands can be seen as
follows:
Hand->Teaching>NTEACHING Ei 1 - 6 100% Z1
SEQUENCE : 33
Pnt: 2 SENSOR
Command: Switch on sensor
Sensor no.: 02
Command: Sensor path
Sensor no.: 11
Sensor no.: 13
Command: Sensor point
Command: Switch off senso
Sensor no.: 01
RESET
F1
COMMAND SENS.NO DELETE
F2
F3
F4
F5
]
Press the [Esc] key and the entered data will be imported by the controller and the
menu for entering additional information will then be displayed.
]
Press the [Esc] key again in order to return to the main teaching menu.
In order to correct previously entered sensor functions read the "Correcting the
sensor parameters" section in chapter 8 "Program editing".
07.03.02
Elektroplanung-und Anlagenbau
Page:7-41
VRS 1
Commentary
New teaching F5-F3
For each point it is possible to edit a 16 line (each line has 40 characters) commentary. The
editing field covers either 4 or 13 screen lines, depending on the type of hand console
connected to the system. The commentary lines on the hand console can be scrolled
upwards or downwards as required.
On the hand console, which does not have an alpha key available for use, the entering of
these characters is made possible with the help of a screen selection list. The required
characters are selected by using the joystick and imported by using the [F1] key.
Commentary for Pnt.1
Page:7-42
Ret
Delete
->[] []->
F1
F2
F3
Ins/S-P
ABC/abc
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Search run
New teaching F5-F4
The search function can be implemented as a standard sensor function that can be used, for
example, for tasks associated with palettes. With this functionality one or several palette
stacks can be processed in a simple way.
This positions the gripper close to the palette stacks at a faster velocity. At a specific
distance it can be stopped at a definable, reduced velocity and the tool piece can be fed in
precisely at creep velocity. The part will be gripped so that a process can be carried out.
Gripper with proximity sensors:
An additional two proximity sensors having different switching distances can be fitted to the
gripper.
D ISTA N T c o nta c t
P1
C LO SE c o n ta c t
P2
P3
The DISTANT contact switches in at a set distance from the destination point and this
effects the switching over from the previous traversing velocity to a pre-set search velocity.
The CLOSE contact switches directly at the destination point and starts the operating
process (gripping, welding etc.).
In the example above, the robot traverses linearly from P1 to P2. The DISTANT contact
switches in and continues to traverse at creep velocity in the P2 direction until the CLOSE
contact switches in. At this position, without the having reached point P2, the trajectory will
be interrupted and the robot will be stopped.
The programmed PLC instructions from P2 will be processed, for example, in order to close
the gripper. Afterwards it will traverse directly to point P3.
During a search run the following conventions must be maintained:
• P1 must be programmed to be in front of the palette stack.
• P2 must refer to the palette stack in a straight line extension to P1 with the
programmed LIN interpolation method.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-43
VRS 1
• The P2 point should lie outside the deepest point of the palette stack. The search
run parameter must also be entered in this point.
• P3 must be programmed so that after gripping the tool pieces at this point it must
be able to traverse between each position between P1 and P2 without a collision
occurring.
The contact-switching signal will be transferred via the PLC inputs to the controller.
]
The following screen will be displayed after selecting the new teaching main
menu and then pressing the [F5] and [F2] function keys:
Hand->Teaching>NTEACHING Ia 1 - 6 100% Z1
SEQUENCE : 33
Pnt:
2
Search run
Contact distant
:
0
Contact close
:
0
:
1
Search speed
Braking factor (0:old)
:
0
Marker
F1
F2
F3
F4
F5
You can enter:
• The PLC input for the DISTANT contact
• The PLC input for the CLOSE contact
• The required search velocity as a % of the programmed traversing velocity
(1-100 %)
• The required braking factor (0 – 255)
The setting of the PLC inputs for the DISTANT/CLOSE contacts can also be entered as
logical linking conditions in the form of a marker.
In the search run alongside the contact entry: Distant, close and the search run velocity,
there is now the option to control the rerun.
The rerun is controlled via the braking factor. The default value here is "0", i.e. : the search
run has the same functionality as in version 1.10. In addition, you now have the opportunity
of setting any value between 1 and 255. The value of "1" represents the shortest slowing
down path. If you do not attain the required search run using the default value of "0", the
robot will stop too late, so the braking factor in the search run should be modified. The
default value of "0" normally corresponds to a braking factor of 26. However, this depends on
the type of robot and the program version. If the value selected for the braking factor is too
small, the robot will jerk when stopping (releases the close contact). In this case the value
must be increased, or the search run velocity reduced.
Attention:
The value of the braking factor must not be less than 5!
Page:7-44
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
After the [F3] function key has been pressed, the identification M0 will be displayed on the
screen.
]
Enter the No. of the programmed marker.
Further information regarding the markers can be found in the "PLC Markers"
section of chapter 9 "PLC Programming".
Remarks:
The programming of a marker is required, if the operating materials controller is executed as
multi-channel by search run encoder for safety reasons.
!
Take into consideration that the function of the marker will be first implemented, when
the programmed marker content is processed. For this reason the marker should be
defined at least 1 TCP before the actual enquiry.
]
Press the [Esc] key and the controller will import the entered data.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-45
VRS 1
Co-ordinates display
New teaching F5-F5
This function can be called up by using the [F5] (co-ord. display) function key in the teaching
menu under correction and inserting in the second menu level and contains the following
display possibilities:
Current co-ordinates
TCP co-ordinates or axis angle correspond to the present position of the robot.
Programmed co-ordinates
TCP co-ordinates or axis angle correspond to the saved data of the programmed TCP's.
Delta co-ordinates
The differential value of the TCP co-ordinates or axis angle refers to the freely adjustable
start and end points for the area of the programmed sequence that is to be searched.
The co-ordinates can be displayed as:
• Axis or cartesian co-ordinates (TCP) orientation related in accordance with EULER
or RPY
An explanation of the orientation display in accordance with EULER or
RPY can be found in the "Cartesian shifts in accordance with
EULER/RPY" section in chapter 8 "Program editing".
• Delta co-ordinates refer to the basic or head co-ordinate systems
]
•
The co-ordinates screen will be displayed after selecting the new teaching main
menu and then pressing the [F5] and [F2] function keys:
Programmed axis co-ordinates
Hand->Teaching>NTEACHING Ei 1 - 6 100% Z1
SEQUENCE: 6
Pnt: 0
PROGRAMMED AXIS CO-ORDINATES
A1 =
8.23 deg.
A4 =
-87.18 deg.
A2 =
21.46 deg.
A5 =
32.94 deg
A6 =
109.57 deg.
A3 =
16.91 deg
Continue
F1
Page:7-46
Unit
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The F1 function key (continue) toggles:
By pressing [F1] you are taken to the:
• Current axis co-ordinates menu
Hand->Teaching>NTEACHING Ei 1 - 6 100% Z1
SEQUENCE: 6
Pnt: 0
CURRENT AXIS CO-ORDINATES
A1 =
8.23 deg.
A4 =
-87.18 deg.
A2 =
21.46 deg.
A5 =
32.94 deg.
A6 =
109.57 deg.
A3 =
16.91 deg.
Continue
F1
Unit
F2
F3
F4
F5
After pressing [F1] again you will be taken to the:
• Delta axis co-ordinates menu
Hand->Teaching>NTEACHING Ei 1 - 6 100% Z1
SEQUENCE: 6
Pnt: 0
DELTA AXIS CO-ORD.
CURR.CO - P0
A1 =
0.00 deg.
A4 =
0.00 deg.
A2 =
0.00 deg.
A5 =
0.00 deg.
A6 =
0.00 deg.
A3 =
0.00 deg.
Delta
Continue defin.
Unit
F1
F2
F3
F4
F5
Pressing [F1] yet again will take you to the output menu:
• Programmed axis co-ordinates
Use the F5 (unit) to select between:
•
•
•
Axis angle
Cartesian co-ordinates with Euler-angle
Cartesian co-ordinates with RPY-angle
This is possible in either of the menus described above.
As a result of the programmed co-ordinates, the following will be displayed:
Hand->Teaching>NTEACHING Ei 1 - 6 100% Z1
SEQUENCE: 6
Pnt: 0
PROGRAMMED AXIS CO-ORDINATES
A1 =
8.23 deg.
A4 =
-87.18 deg.
A2 =
21.46 deg.
A5 =
32.94 deg.
A6 =
109.57 deg.
A3 =
16.91 deg.
Continue
F1
07.03.02
Unit
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:7-47
VRS 1
Press [F5] to go to and display:
• Cartesian co-ordinates with Euler-angles:
Hand->Teaching>NTEACHING Ei1 - 6 100% Z1
SEQUENCE: 6
Pnt: 0
PROGRAMMED CART. CO-ORDINATES
X = 1.1817 m
A = 32.03 deg
Y = -0.0872 m B = 122.82 deg
EULER
Z = 0.6504 m
C = -88.27 deg
Continue
F1
Unit
F2
F3
F4
F5
After pressing [F5] once again you will be taken to this menu
• Cartesian co-ordinates with RPY-angles:
Hand->Teaching>NTEACHING Ei 1 - 6 100% Z1
SEQUENCE: 6
Pnt: 0
PROGRAMMED CART. CO-ORDINATES
X = 1.1817 m
A = -58.90 deg.
Y = -0.0872 m B =
1.45 deg
RPY
Z = 0.6504 m
C = -122.83 deg
Continue
F1
]
•
Unit
F2
F3
F4
F5
After pressing [F5] once again you will be returned to the output menu
Sensor data (only displayed when a 3.X teach sensor module is present and active)
Hand->Teaching>NTEACHING Ei 1 - 6 100% Z1
SEQUENCE: 6
Pnt: 0
Continue
F1
Unit
F2
F3
F4
F5
Press [F5] once again to jump back to the output menu
• axis angle.
Page:7-48
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Delta co-ordinates
Delta co-ordinates are generated from the differential values of the TCP co-ordinates or the
axis angle referring to the freely adjustable start and end points for the area of the
programmed sequence that is to be searched.
The determining of the differential values can be made from a freely selectable TCP:
• Forwards from any TCP to the sequence end
• Backwards from any TCP to the sequence start
• Either forwards or backwards to the present temporary (current) axis position
or from the current TCP (robot is at a programmed point):
• Forwards from any TCP to the maximum sequence end
• Backwards from any TCP to the maximum sequence start
If the robot is stopped between two TCP's, the definition can be made from the current axis
position
• Forwards to any TCP to the maximum sequence end
• Backwards from any TCP to the maximum sequence start.
If the delta co-ordinates screen has been selected, the delta definition can be entered using
the [F2] function key.
Hand->Teaching>NTEACHING Ei 1 - 6 100% Z1
SEQUENCE: 6
Pnt: 0
DIFFERTIAL DISPLAY DEFINITION
CURRENT CO-ORD Px
^
|
Input: 0
Current
Co-ord.
Px+1
ESC
Px-1
F1
F2
F3
F4
F5
The information arrow (which is controlled by the [Cursor] keys) indicates the start and end
points, between which the calculation of the differential value will be made.
Left arrow
Right arrow
= start point
= end point
07.03.02
Elektroplanung-und Anlagenbau
Page:7-49
VRS 1
The cursor will blink beneath the input field.
]
Enter the required point-No. This will be displayed in the input field.
Hand->Teaching>NTEACHING Ei 1 - 6 100% Z1
SEQUENCE: 6
Pnt: 33
DIFFERTIAL DISPLAY DEFINITION
P20 - P30
^
|
Input: 30
Current
Co-ord.
Px+1
ESC
Px-1
F1
]
F2
F3
F4
F5
Press the [Return] key.
The entered number will be displayed in the area above the information arrow. This
automatically jumps below to the second area, so that the entry can now be made.
Page:7-50
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
[F3]= Esc
The entering is terminated, the difference calculation will be started and displayed on the
screen afterwards.
Hand->Teaching->NTEACHING Ei1 - 6 100% Z1
SEQUENCE: 6
Pnt: 33
DELTA AXIS CO-ORD. P20 - P30
A1 = -142.10 deg.
A4 =
0.00
deg.
A5 = -0.02
deg.
A2 = -37.17 deg.
A6 = -1.62
deg.
A3 =
-0.04 deg.
Delta
Continue defin.
Unit
F1
F2
F3
F4
F5
Other entering possibilities:
Hand->Teaching->NTEACHING Ei 1 - 6 100% Z1
SEQUENCE: 6
Pnt: 33
DIFFERTIAL DISPLAY DEFINITION
P20 - P30
^
|
Input: 30
Current
Co-ord.
Px+1
ESC
Px-1
F1
F2
F3
F4
F5
[F1] = Cur. Co-ord.
The current co-ordinates show the present position of all axes (position of the controlled point
or between two points). Press the [F1] function key to set this position as the start or end
point for a differential value calculation, depending on the setting of the information arrow.
Example:
Hand->Teaching->NTEACHING Ei 1 - 6 100% Z1
SEQUENCE: 6
Pnt: 33
DIFFERTIAL DISPLAY DEFINITION
Px - Px + 5
^
|
Input: 0
Current
Co-ord.
Px+1
ESC
Px-1
F1
F2
F3
F4
F5
The robot will be stopped on the path to point 33.
The difference calculation is taken from the current position to point 33.
[F2] = Px+1 [F4] = Px-1
the co-ordinate values corresponding to the TCP displayed on the screen are identified with
Px (here: point-No. 33).
07.03.02
Elektroplanung-und Anlagenbau
Page:7-51
VRS 1
[F2] = Px+1
Refers to the current Px point where the co-ordinate values of the following points are set up
for calculating.
[F4] = Px-1
Refers to the current Px point where the co-ordinate values of the previous points are set up
for calculating.
Continually pressing either [F2] or [F4] function keys will respectively increase or
decrease the displayed reference point-No.: (Px + 5) by 1.
]
[F3] = Esc
Starts the difference calculation and afterwards displays it on the screen. In the example
given above, the difference between the co-ordinates from Px = Pnt No. 33 and Px+5 = Pnt
No. 38.
Hand->Teaching->NTEACHING Ei 1 - 6
SEQUENCE: 6
Pnt: 33
DELTA AXIS CO-ORD. P33 - P38
A1 = -142.10 deg.
A4 =
0.00
A2 = -37.17 deg.
A5 = -0.02
A6 = -1.62
A3 =
-0.04 deg.
Delta
Continue defin.
F1
F2
F3
F4
100% Z1
deg.
deg.
deg.
Unit
F5
Modifying the displayed difference co-ordinates:
[F5] = Unit
Use the [F5] function key to switch over to the cartesian delta co-ordinates. Within the
cartesian delta co-ordinates you can use [F5] to toggle between the different calculation
circuits:
•
•
•
•
•
EULER/HEAD
EULER/BASIC
RPY/HEAD
RPY/BASIC
Point distance in 1/10 mm
Page:7-52
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Setting up a sub-program
A sub-program (S-P) is a finalised operating sequence that can always be repeated in the
same manner. In addition to sequences the sub-programs can also be called up from
sequences.
The sub-programs
• are programmed (taught) in the same way as a sequence.
• It contains a sequence No. and a sub-program No. (a maximum of 127 subprograms can be programmed)
Calling up a sub-program
A S-P call is programmed into the call point of the PLC. Information regarding this can be
found in chapter 9 "PLC programming"
Example of a tool change:
In a TCP there is a sub-program call programmed in the PLC.
The robot:
• Exits the current TCP
• Traverses to the tool changing station
• Changes the tool
• Exits the station
• and traverses onwards to the next programmed point of the operating sequence
This run has to be programmed once as a sub-program (taught) and then can be called up
again at any point in a sequence.
07.03.02
Elektroplanung-und Anlagenbau
Page:7-53
VRS 1
Example of an operating sequence with sub-program branching:
STA RT
EN D
Po int “0 ”
6 “SE”
C a llS-P
1
2
5
4
3
C ontinue tra ve rsing
to next
p rog ra m m ed
p o int in the seq uenc e
Tra verse to tool
c ha ng e sta tio n
0
3 “S-P”
SUB-PR O G R A M
1
2
G rip to ol
Exit to ol
c ha ng e sta tio n
Programming sub-programs
A sub-program is programmed in the same way as a sequence.
$
The following menu will be displayed after selecting the [Hand] operating mode and
then pressing the [F1] function key:
Hand->Teaching
Sequence
S-P
New
teaching
F1
:
:
Ei 1 - 6 100% Z1
1
1
Edit
Insert
Delete
Directory
F2
F3
F4
F5
The cursor blinks at the input field for the sequence number.
] Use [Cursor up] and [Cursor down] keys to move the cursor to the sub-program
number input field.
]
Now enter an unused sub-program number.
]
Press the [F1] function key. You will now jump to the new teaching function of a
sub-program. This functionality is identical with the new teaching sequence.
Page:7-54
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Finalising sub-programs
Each programmable sub-program must be finalised with an end identifier instruction in the
last programmed TCP. To do this, program the S-P end identifier in the additional
information.
]
When you have taught the co-ordinates and the relevant additional information for
the last TCP's, press the [F4] function key in order to enter the end identifier
instruction.
The S-P end additional information will be displayed on the screen.
Hand->Teaching->NTEACHING Ei1 - 6 100% Z1
Sequence : 1 Pnt : 10
PTP
S-P end
Vb:
100 %
Ve:
0 %
Aa:
100 %
Ve:
100 %
Jerk:
100 %
Toler.:
100 1/10 deg
SPC
---
F1
]
COORDI- Interpolation
NATES
F2
F3
S/S-P
end
F4
Continue
F5
Press the [F4] function key repeatedly to clear the end identifier instruction entry.
The S-P end additional information entry will then be deleted or can now be reset.
Calling up a sub-program
If you wish to jump to another sub-program in a TCP, this must be carried out via an entry in
the PLC.
The programming can be found in chapter 9 "PLC Programming".
07.03.02
Elektroplanung-und Anlagenbau
Page:7-55
VRS 1
Sequences and sub-program overview
Hand-F5
All previously programmed sequences and sub-programs will be displayed in this overview.
]
The following menu will be displayed after selecting the [Hand] operating mode and
then pressing the [F5] function key:
Hand->Teaching->Directory
Total:27%=61
Seq
Name
Created
Modified
Pnts
1
SEQ001
20.10.98
22.10.98
8
2
SEQ002
20.10.97
22.05.98
7
11
SEQ011
20.01.96
21.03.97
30
101
REF.POS 01.01.95
01.01.95
8
104
Variant
20.10.98
22.10.98
8
Page S/S-P
Page+
F1
F2
F3
F4
F5
The following are displayed:
• Every programmed sequence or S-P No.
• The name of the sequences or sub-program
• The date that it was created
• The date of the last modification
• The total number of all correctly programmed points
• The corresponding loading of the memory in %
12 (5 with the old hand console) from a maximum of 127 possible sequences or subprograms will be displayed on the screen.
] Press the [F1] function key to display the next 12 (up to a maximum of 127).
Press the [F2] function key to display the previous 12 again.
Page:7-56
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
8. Program editing
8.
Program editing ................................................................................... 8-1
Correcting ...................................................................................................... 8-3
Correcting individual TCP's.......................................................................... 8-4
Correcting the PLC instructions .................................................................. 8-5
Correcting the co-ordinates.......................................................................... 8-5
Editing the co-ordinates................................................................................ 8-7
Correcting the interpolation method ........................................................... 8-8
Calling the next / previous point for correction ........................................ 8-10
Correcting additional information.............................................................. 8-10
Correcting the tool No................................................................................. 8-11
Correcting the kinematic No....................................................................... 8-11
Correcting the weave parameters .............................................................. 8-11
Correcting the sensor functions ................................................................ 8-13
Correcting the commentaries..................................................................... 8-14
Correcting the search run parameters....................................................... 8-14
Correcting the complete program.............................................................. 8-16
Complete program: Geometry.................................................................... 8-17
Point translation according to angles....................................................... 8-17
Carrying out the correction (shifting the joining angle)........................... 8-20
Cartesian point shifting............................................................................... 8-21
Example of a head or basic co-ordinates cartesian program shift ......... 8-22
EULER cartesian shift ................................................................................. 8-23
Example of a head co-ord. cartesian program shift using Euler-angles 8-23
Example of a head co-ord. cartesian program shift using RPY-angles .. 8-23
Program mirroring ....................................................................................... 8-25
Tool symmetry for program mirroring ....................................................... 8-29
Program transformation.............................................................................. 8-31
Mirroring and transformation ..................................................................... 8-35
Complete program: additional information ............................................... 8-36
PLC instruction programming corrections ............................................... 8-38
Traversing parameter programming corrections ..................................... 8-39
Interpolation method programming corrections ...................................... 8-40
Weaving parameter programming corrections ......................................... 8-40
Programming Tool No. corrections ........................................................... 8-41
Editing program names............................................................................... 8-41
Inserting a TCP ............................................................................................ 8-41
Modifying additional information ............................................................... 8-44
Inserting in an existing point sequence .................................................... 8-45
Inserting in front of "0" ............................................................................... 8-45
Inserting behind the last point in the sequence (SE) ............................... 8-45
Collisions due to insertions........................................................................ 8-46
Deleting a TCP ............................................................................................. 8-47
Deleting the current TCP............................................................................. 8-47
Deleting a specific TCP ............................................................................... 8-48
Deleting: from one point-No. to another point-No. ................................... 8-48
Deleting an entire program (sequence) ..................................................... 8-49
Deleting several programs (sequences).................................................... 8-50
Deleting a selected sequence..................................................................... 8-50
Deleting all sequences simultaneously ..................................................... 8-50
07.03.02
Elektroplanung-und Anlagenbau
Page:8-1
VRS 1
Danger of collisions due to deleting .......................................................... 8-51
Page:8-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Correcting
Hand-F1-F2
This function allows you to optimally match the required or modified process conditions
optimal of a previously programmed:
• TCP,
• Entire sequences
or
• To determine a number of consecutive points in a sequence,
as well as
• A sub-program or a section of one,
at any time by making the relevant correction to the programmed co-ordinates and/or the
entered additional information.
Note:
The number of programmed TCP's cannot be changed! Changes are only possible via
the insert or delete function.
!
Before every correction operation copy the original movement sequence to a
sequence-No. that is not being used. Then it is always possible to return to the original
sequence.
Read the "Copying sequences to SRAM disc" section in chapter 12 "Service
programs" for more information regarding this.
]
Press the [F1] function key.
]
Enter the sequence-No. that is to be corrected.
]
Press the [F2] function key. The following menu will be displayed:
Hand Î Teaching Î EDIT
SEQUENCE:
5 Pnt: 10
F1 = single points
F2 = complete program: Geometry
F3 = complete program: Additional information
F4 = edit program name
Points
F1
]
Geometry Add-info
F2
F3
Name
F4
F5
Press the [F1] - [F4] function keys to call up the required correction function.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-3
VRS 1
Hand-F1-F2-F1
Correcting individual TCP's
The correcting of individual TCP's involves modifying the
• The previously programmed co-ordinates,
• The entered additional information
or
• The importing of the co-ordinates of any sequence or S-P's (point copying) of a freely
selectable previously programmed TCP.
In order to correct an individual TCP, proceed as follows:
]
Traverse to the TCP that is to be corrected using Single-Step STOP.
]
Select the [Hand] operating mode.
]
Press the [F1] function key.
]
Press the [F2] function key.
]
Press the [F1] function key. The following menu will be displayed:
Ei 1 - 6 100 % Z1
Hand Î Teaching Î EDIT
SEQUENCE:
5 Pnt: 10
PTP
Vb: 100 %
Ve: 100
%
Aa: 100 %
Ae: 100
%
Jerk: 100 %
Toler.: 200 1/10 deg.
PLC
- - -I
F1
COORDI- Interpolation
NATES
F2
F3
next
point
Continue
F4
F5
Displayed here is the programmed additional information for the point you have just
traversed up to. Additionally to this you can press the relevant function key in order to carry
out other corrections.
z
z
Ï
Ð
Page:8-4
You can page forwards to the next point or backwards to the previous point
from the point displayed on the screen by using [Shf] and [Cursor] key
combinations.
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F2-F1-F1
Correcting the PLC instructions
In order to correct the PLC instructions you must press the [F1] function key to jump to the
PLC teaching menu. Here you can correct previously programmed functions or enter
additional ones such as outputs, markers, gripper functions, wait functions, counters, PLC
macros etc.
Read chapter 9 "PLC Programming" for more information regarding this.
Hand-F1-F2-F1-F2
Correcting the co-ordinates
In order to correct the co-ordinates of a previously programmed TCP, it is advisable to
traverse to this point using Single-Step STOP mode.
]
Traverse to the TCP that is to be corrected using Single-Step STOP.
]
Select the [Hand] operating mode.
]
Press the [F1] function key.
]
Press the [F2] function key.
]
Press the [F1] function key.
]
Press the [F2] function key. As opposed to new teaching the co-ordinates will not be
modified during correction. Instead, the following menu will be displayed:
Hand Î Teaching Î EDIT
- - - - - - - - - - - - - - SEQ005 - - - - - - - - - - - - - - SEQUENCE:
5 Pnt: 10
CO-ORDINATES save / edit. / display
External-co-ordinates from Point No:
2
Sequence No: 7
Save
|
|
Coordinates
External Current SEQ/S-P
edit.
display
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:8-5
VRS 1
The selected sequence and point-No. for correction will be displayed on the screen. This
menu offers various options for correcting the axis co-ordinates of the displayed point.
1. Importing the current robot position co-ordinates.
2. Importing the co-ordinates from a different and previously programmed point (external coordinates).
3. Editing the co-ordinates.
Importing the current co-ordinates
In order to import the current co-ordinates for the point-No. to be corrected, proceed as
follows:
]
Use [Joystick] or [Axis traverse] keys to traverse the robot to the required
position.
]
Press the [F2] function key. The current co-ordinates for the point to be corrected
will be imported and saved.
Importing external co-ordinates
If the co-ordinates of another previously programmed point have to be imported for the pointNo. to be corrected, proceed as follows:
]
Enter the number of the point from which the co-ordinates must be imported in the
"Point-No." input field.
]
Use the [Return] key to confirm the entry.
]
Enter the sequence-No. in which the previously entered point can be found.
]
If the co-ordinates have to be imported from a sub-program, press the [F3] function
key. The display will change from sequence-No. to S-P No.
]
Press the [F1] function key to import the co-ordinates from the entered sequence
and the selected point for the point to be corrected.
Page:8-6
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Editing the co-ordinates
If you have to edit the co-ordinates for the point to be corrected, proceed as follows:
]
Press the [F4] function key. The screen will change to the following menu:
Hand Î Teaching Î EDIT
- - - - - - - - - - - - - - SEQ.005 - - - - - - - - - - - - - - SEQUENCE:
5 Pnt: 10
PROGRAMMED AXIS-CO-ORDINATES
A1=
11.00
deg.
A4=
5.00
deg.
A2=
0.98 deg.
A5= -25.00
deg.
A3= -70.00
deg.
A6=
0.00
deg.
Edit
Unit
F1
F2
F3
F4
F5
]
Press [F5] (Unit) to switch between axis angle, cartesian co-ordinates with Eulerangles and cartesian co-ordinates with RPY angles.
]
If [F1] is pressed the editing mode will be switched in and the values can then be
modified. The screen changes to the following display:
Hand Î Teaching Î EDIT
- - - - - - - - - - - - - - SEQ.005 - - - - - - - - - - - - SEQUENCE:
5 Pnt: 10
EDIT PROGRAMMED AXIS-CO-ORDINATES
A1= 011.00 deg.
A2= 000.98 deg.
A3= -070.00 deg.
Abort
F1
]
F2
A4= 005.00 deg.
A5= -025.00 deg.
A6= 000.00 deg.
Save
F3
F4
F5
After pressing the [F5] function key the previous co-ordinates displayed for editing
will be checked to see if they can be reached and will be saved if an error does not
occur.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-7
VRS 1
Hand-F1-F2-F1-F3
Correcting the interpolation method
] The menu for the interpolation methods will be displayed after the relevant function
key has been pressed.
The following interpolation methods are selectable via the [F1] - [F5] function keys:
Point-To-Point
Ei 1 - 6 100 % Z1
Hand Î Teaching Î EDIT
SEQUENCE:
5 Pnt: 10
PTP
Vb: 100 %
Ve: 100
%
Aa: 100 %
Ae: 100
%
Jerk: 100 %
Toler.: 200 1/10 deg.
LIN
SWVL
(PIVO)
F1
F2
CIRH
F3
CIRE
F4
CONTINUE
F5
Linear
Hand Î Teaching Î EDIT
Ei 1 - 6 100 % Z1
SEQUENCE
:5
Pnt: 10
LIN
Vb: 1666 mm/sec Ve:
1666
mm/sec
Aa: 2300 mm/sec2 Ae:
2300
mm/sec2
Jerk: 100 %
Toler:
200
mm
SWVL
(PIVO)
F1
CIRH
CIRE
PTP
CONTINUE
F2
F3
F4
F5
Circular interpolation point
Ei 1 - 6 100 % Z1
Hand Î Teaching Î EDIT
SEQUENCE:
5 Pnt: 10
CIRH
Vb: 1666 mm/sec Ve:
1666
mm/sec
Aa: 2300 mm/sec2 Ae:
2300
mm/sec2
Jerk: 100 %
Toler:
200 mm
CIRE
F1
Page:8-8
PTP
LIN
F2
F3
SWVL CONTINUE
(PIVO)
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Circular end points
Hand Î Teaching Î EDIT
Ei 1 - 6 100 % Z1
SEQUENCE:
5 Pnt: 10
CIRE
Vb: 1666 mm/sec Ve:
1666
mm/sec
Aa: 2300 mm/sec2 Ae:
2300
mm/sec2
Jerk: 100 %
Toler
200 mm
PTP
LIN
SWVL
(PIVO)
CIRH
CONTINUE
F1
F2
F3
F4
F5
Swivelling
Hand Î Teaching Î EDIT
Ei 1 - 6 100 % Z1
SEQUENCE: 5
Pnt: 10
SWVL (PIVO)
Vb: 1666 mm/sec Ve:
1666
mm/sec
Aa: 2300 mm/sec2 Ae:
2300
mm/sec2
Jerk: 100 %
Toler:
200
mm
CIRH
F1
CIRE
PTP
LIN
CONTINUE
F2
F3
F4
F5
Spline
Hand Î Teaching Î EDIT
Ei 1 - 6 100 % Z1
SEQUENCE:
5 Pnt: 10
SPL
Vb: 1666 mm/sec Ve:
1666
mm/sec
Aa: 2300 mm/sec2 Ae:
2300
mm/sec2
Jerk: 100 %
Toler:
200 mm
PTP
LIN
SWVL
(PIVO)
CIRH
CONTINUE
F1
F2
F3
F4
F5
MPG
Ei 1 - 6 100 % Z1
Hand Î Teaching Î EDIT
SEQUENCE:
5 Pnt: 10
MPG
Vb: 1666 mm/sec Ve:
1666
mm/sec
Aa: 2300 mm/sec2 Ae:
2300
mm/sec2
Jerk: 100 %
Toler:
200 mm
07.03.02
PTP
LIN
SWVL
(PIVO)
CIRH
CONTINUE
F1
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:8-9
VRS 1
Hand-F1-F2-F1- F4
Calling the next / previous point for correction
Use the [F4] function key to page forward to the next point. This will be displayed on the
screen together with all relevant information.
The same function can be carried out by using the [Shf] + [Cursor DOWN] or [Shf] +
[Cursor RIGHT] key combinations.
Use the [-] key to page backwards to the previous point.
The same function can be carried out by using the [Shf] + [Cursor UP] or [Shf] + [Cursor
LEFT] key combinations.
If you go past the end of the programmed sequence or the sub-program whilst paging
through, you can return to the last point by pressing the [Esc] key.
Hand-F1-F2-F1-F5
Correcting additional information
Use the [F5] function key to change the menu and to correct other additional information.
Additional information covers:
• Weaving
• Sensor functions
• Commentaries
• Search runs
• Co-ordinate displays
• Tool Nos.
• Kinematic Nos.
Hand Î Teaching Î EDIT
SEQUENCE:
5 Pnt: 10
S-P connection :
Tool
:
Kinematics
:
Page:8-10
Weave
Sensor
F1
F2
Ei 1 - 6 100 % Z1
1
0
Comment. Search
F3
F4
Co-ord
display
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F2-F1-F5
Correcting the tool No.
A tool No. can be corrected or a new one can be entered.
] Use the [Cursor] keys to position the cursor on the input field for the tool number.
]
Enter the new tool No.
]
Use the [Return] key to confirm the entry. The correction will be immediately
imported by the computer system.
Hand F1-F2-F1-F5
Correcting the kinematic No.
Use the Kinematic No. to make a selection from the active auxiliary axes (Kinematics) for
special requirements. Kinematic Nos. can be corrected or a new one can be entered.
A special description of your system can be supplied upon request.
]
Use the [Cursor] keys to position the cursor on the input field
]
Enter the new Kinematic No.
]
Use the [Return] key to confirm the entry. The correction will be immediately
imported by the computer system.
Hand F1-F2-F1-F5-F1
Correcting the weave parameters
Weaving is the name of an adjustable swivelling (oscillating) movement that will be
superimposed (weaving trajectory) on a programmed trajectory (linear or circular).
]
The following menu will be displayed after pressing the relevant function keys:
Ei 1 - 6 100 % Z1
Hand Î Teaching Î EDIT
SEQUENCE:
5 Pnt: 10
Weave parameters
Shape
0 :
no weaving
Amplitude
0 :
[in 1/10 mm]
Period
0 :
[in 1/10 mm]
Opening
0 :
[in 1/10 mm]
Plane
0 :
[in 1/10 mm]
F1
F2
F3
F4
F5
]
Use the [cursor up/down] keys to move the cursor to the respective input field.
]
Enter a weaving shape.
Weaving shapes: 0
1
2
3
4
07.03.02
no weaving
SINUS for all axes
SPIRALE for all axes
SINUS for manual axes
SPIRALE for manual axes
Elektroplanung-und Anlagenbau
Page:8-11
VRS 1
Enter the weaving trajectory (amplitude and duration in 1/10mm).
]
Confirm the entry by pressing the [Return] key. The correction will be immediately imported
by the computer system.
Sp ira lw e a ve
Sinus w ea ve
w itho ut a sym m e tric s
Sinus w ea ve w ith
a sym m etric s (= 90°)
A
A SY = 90°
A
A
P
A
O
P
A =
O =
P=
A SY
P
A m p litu d e
O p e n ing
Pe rio d
= A sym m e tric
Read the "Weaving" section in chapter 7 "Programming sequences" for more
information regarding this.
Page:8-12
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand F1-F2-F1-F5-F2
Correcting the sensor functions
Up to 4 different sensor functions can be programmed into each TCP by the controller.
]
The following menu will be displayed after pressing the relevant function key:
Hand Î Teaching Î EDIT
Ei 1 - 6 100 % Z1
SEQUENCE: 5 Pnt: 10
SENSOR
Command: switch off sensor
Sensor no: 01
Command: switch on sensor
Sensor no: 02
Command:
Command:
RESET
F1
COMM.
F2
F3
SENS. NO
DEL.
F4
F5
The previously programmed sensor commands together with the respective sensor No will
be displayed.
[F1] RESET
Use this function key to position the cursor on any of the next command lines. Up to 4
command entries are possible per point.
[F3] COMMAND
If this function key is pressed, the function key assignments are changed. Now the 4 possible
sensor commands and their input potions will be displayed:
F1 = switch on sensor
F2 = sensor path
F3 = sensor point
F4 = switch off sensor
After entering the command via the relevant function key, the respective command will be
displayed in the actual screen line and the old function key assignment will be reactivated.
[F4] SENSOR NO.
Use this function key to assign the previously entered command to a relevant sensor-No. (1 15).
[F5] DELETE
Use this function key to delete the entire line on which the cursor is positioned. This will
delete both the command as well as the sensor No.!
Read the "Sensor" section in the "Programming Sequences" chapter for more
information regarding this.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-13
VRS 1
Hand F1-F2-F1-F5-F3
Correcting the commentaries
For each point it is possible to edit a commentary that has a maximum of 16 lines, each of
which are 40 characters in length. The editing field covers 4 or 13 display lines depending on
which version of hand console is connected. If required, the commentary lines can be
scrolled upwards or downwards on the hand console.
For hand consoles that do not have an alpha key fitted, the entering of the characters is
made possible via a selection list displayed on the screen. The required characters are
selected using the joystick and imported by pressing the [F1] key.
Commentary for Pnt: 4
ABCDEFGHIJKLMNOPQRSTUVWXYZ ?!&().,;:/-<>
ˆ
RET
Delete ->[] []-> Ins/O-W ABCabc
F1
F2
F3
F4
F5
Read the "Commentary" section in the "Programming Sequences" chapter for more
information regarding this.
Hand F1-F2-F1-F5-F4
Correcting the search run parameters
The search run is placed in the first line of the palette entries. With this function you can
process one or more palette stacks in an easy way.
Here the gripper approaches the palette stack at a high velocity. At a certain distance from
the stack it will brake to a pre-defined reduced velocity and the tool will be traversed in creep
mode to the precise position.
The part will be gripped and a process can be undertaken.
]
The following menu will be displayed after pressing the relevant function key:
Hand Î Teaching Î EDIT
SEQUENCE: 5 Pnt: 10
Search
Distant contact
:
Close contact
:
Search velocity
:
Braking factor (0:old)
:
Marker
F1
Page:8-14
F2
F3
Ei 1 - 6 100 % Z1
0
0
1
0
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The following values can be corrected:
• PLC input for the DISTANT search contact
• PLC input for the CLOSE search contact
• Search velocity as a % of the programmed traversing velocity (1-100 %)
• Braking factor (value: 0 – 255). The value 1 represents the shortest slowing down
trajectory and the value 255 represents the longest slowing down trajectory.
If the selected value is to small, the equipment will judder when it stops. In this
case the value must be increased or the search velocity must be reduced.
]
Confirm your entry by pressing the [Return] key. The controller will now import the
entered data.
]
Press the [F3] function key in order to initiate the search CLOSE/DISTANT contact
function via a marker.
Read the "Search run" section in the "Programming Sequences" chapter for more
information regarding this.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-15
VRS 1
Correcting the complete program
Hand F1-F2
The advantage of these correction functions is that the correction only has to be executed
once for a specific number of consecutive points or for an entire sequence or S-P!
This type of correction can be required for:
• A modification to the tool acceptor,
• When positioning procedures are modified with regards to the free area required
for the tool movement,
• The settings required for the angle adjustment of a spray pistol,
• When transferring previously programmed operating sequences to another robot
that has the same function.
The correction of an entire program or a section of a program covers the following functions:
• Point shifting according to the joining angle,
• Cartesian point shifting,
• EULER cartesian point shifting,
• RPY cartesian point shifting,
• Program mirroring,
• Program transformation,
• Mirroring and transformation.
]
Select the [Hand] operating mode.
]
Press the [F1] function key.
]
Press the [F2] function key.
The following menu will be displayed:
Ei 1 - 6 100 % Z1
Hand Î Teaching Î EDIT
SEQUENCE:
5
Pnt:
10
F1 =
single points
F2 =
complete program: Geometry
F3 =
complete program: additional information
F4 =
edit program name
Points
F1
Page:8-16
Geometry Add-info
F2
F3
Name
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Complete program: Geometry
Hand-F1-F2-F2
Press the [F2] function key.
The following menu will be displayed:
Correct other points
F1 =
Point transl. according to angles
F2 =
Point translation, cartesian
F3 =
Program mirroring
F4 =
Program transformation
F1
F2
F3
F4
F5
Hand-F1-F2-F2-F1
Point translation according to angles
Press the [F1] function key.
ne w
α
TC P
o ld
A xis 3
α = c o rre c tio n a n g le
re la te d to a xis 3
The following menu will be displayed:
Shifting joining angle
Start pnt:
0
in 1/10 deg.
A1: 0
A4:
A2: 0
A5:
A3: 0
A6:
Execute Add. axis
F1
07.03.02
F2
Ei 1 - 6 100% Z1
Sequence: 5
End pnt:11
0
0
0
Bit
F3
|| HAND ||
|| input ||
==========
Teaching Cur-pos
F4
F5
Elektroplanung-und Anlagenbau
Page:8-17
VRS 1
The following information will be displayed on the screen:
• The selected sequence-No.,
• The start and end point-Nos.,
• The correction dimension in 1/10 degree or bit,
• The current correction values for axes 1 - 6,
• The current input mode will be displayed in the right hand half of the screen: Hand,
Teach or Display mode (Cur-pos. = current axis position).
The cursor blinks under the input field for the start point No. to the entered or displayed end
point No. from which the correction will be made. If the starting point and the end point
numbers are the same these will only be shifted by one point.
[F1] Execute
After pressing this function key the shift (correction) will be executed using the correction
values displayed on the screen.
[F2] G axes / Z-axes
The basic axes (G) 1 - 6 are displayed as the default.
]
Press the [F2] function key in order to display the auxiliary axes (Z) 7 - 12. The
function key assignments will change over from the G to the Z-axes and vice versa.
[F3] Bit /degree
Use the [F3] function key to change the correction value dimensions settings and display
from 1/10 degree to bits (and vice versa).
[F4] Teach/Hand
Entering of the correction value is normally made in the hand input mode via the decimal key.
]
Use the [Cursor] keys to position the cursor on the relevant input field.
]
Enter the new correction value.
]
Confirm the entry by pressing the [Return] key.
]
Press the [F1] function key in order to execute the correction.
TCP can be brought to the correction position by using the [Axis traverse] keys or
[Joystick] in teaching input mode.
Attention! Danger of collisions!
Each correction of an individual axis affects the Tool-Centre-Points (TCP)
settings!
Page:8-18
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Press the [F4] function key in order to switch over to the teaching input mode.
Shifting joining angle
Ei 1 - 6
Start pnt:
0
in 1/10 deg.
A1: 0
A4:
A2: 0
A5:
A3: 0
A6:
Execute
Add. axis
End pnt:11
F1
0
0
0
Bit
F2
F3
100% Z1
Sequence: 5
|| Teaching ||
|| input
||
==========
Teaching Cur-pos
F4
F5
When starting the teaching input mode the current axis position will be set to "0" on the
screen, so that during the traversing the online screen can display the actual correction
position of each axis.
Start teaching inputs
]
Traverse the TCP by using the [Axis traverse] keys or the [Joystick].
Shifting joining angle
Start pnt:
0
in 1/10 deg.
A1: 231
A4:
A2: 154
A5:
A3:-147
A6:
Execute
Add. axis
F1
F2
Ei 1 - 6 100% Z1
Sequence: 5
End pnt:11
4160
203
255
Bi t
F3
|| Teaching ||
|| input
||
==========
Hand
Zero
F4
F5
Correction position reached
]
After reaching the correction position the setting of each axis can be read on the
screen in bits or 1/10 degree with regards to the starting point of the teaching inputs.
]
Press the [F1] function key in order to carry out the correction of the geometry for
the entire program with regards to the new position. Now the previously saved coordinates of all of the points in this sequence will be corrected and resaved.
]
Use the [F5] function key to reset the axis position displayed on the screen back to
"0".
[F5] Cur-pos./Hand
]
Press the [F5] function key in order to display the current position of each of the
axes.
The "Current Position" mode will be displayed on the screen.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-19
VRS 1
]
The [F5] function key assignment will change over to "Hand". At the same time only
the assignment of the [F2] function key = Z-axes is valid and this can be used to
display the current position of the auxiliary axes 7 - 12.
Shift joining angle
Start pnt:
0
in 1/10 deg.
A1: 3
A4:
A2: 294
A5:
A3: 90
A6:
Add. axis
F1
F2
Ei 1 - 6
100% Z1
Sequence: 5
End pnt:11
- 941
248
1101
F3
|| Current ||
|| position ||
==========
F4
F5
Carrying out the correction (shifting the joining angle)
] Press the [F1] function key after having reached the correction position. The shift
will be carried out. The "Shifted point" report will be displayed on the screen.
Each consecutive shifted point No. will be displayed on the screen for checking purposes.
When the entered end point is reached, a 2nd run through will be started. The shifting process
is finished when the following report is displayed on the screen: Shifting carried out.
Page:8-20
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F2-F2
Cartesian point shifting
This method of correction involves a spatial shift of the previously taught operating
sequences or sequence sub-sections within the cartesian co-ordinate systems.
• in X, Y, Z directions with retention of the tool orientation,
• by turning the X, Y or Z-axis (Euler or RPY angles).
Depending on the application case, this shift can be carried out within the head co-ordinates
system or the basic (global) co-ordinate systems.
]
Select the [Hand] operating mode.
]
Press the [F1] function key.
]
Enter the sequence or S-P No. to be corrected.
]
Press the [F2] function key.
]
Press the [F2] function key in order to switch over to the cartesian point shift menu.
The following menu will be displayed:
Point translation cart.
Ei 1 - 6
100% Z1
Sequence: 5
Start pnt:
0
End pnt:11
in 0.1 mm
in 0.1 deg.
RPY BASIC
x: 0
E1-R: 0
|| Hand- ||
y: 0
E2-P: 0
|| input
||
z: 0
E3-Y: 0
==========
Execute EULER
HEAD Teaching Cur-pos
F1
F2
F3
F4
F5
[F1]
Execute (shift)
All of the entered correction values will be imported by the computer system after the
[F1] function key is pressed and the shifting will be started. As already mentioned, this
process will be confirmed by a report displayed on the screen.
[F2]
Toggle between the EULER or RPY modes
[F3]
Toggle between the head and basic mode co-ordinate systems.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-21
VRS 1
Example of a head or basic co-ordinates cartesian program shift
Re la tin g to th e he a d c o -o rd ina te s
(c urre n t p o sitio n o f th e h a nd a xis)
-Y
Shifte d
in -Y
Shifte d
in + X
+X
+Z
P ro g
e
m ie rt
ra m
Fo lg e
Shifte d
in + Z
+Y
-Z
-X
Shifte d
in -Z
Sh ifte d
in -X
Sh ifte d
in + Y
Re la tin g to th e b a sic c o -o rd ina te s
(g lo b a lc o -o rd ina te s)
+Z
Shifte d
in + Z
Shifte d
in -Y
-Y
+X
-Z
rte
m ie
ra m
Pro g
e
Fo lg
Shifte d
in + X
-X
+Y
Shifte d
in -X
Sh ifte d
in + Y
Sh ifte d
in -Z
Page:8-22
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
EULER cartesian shift
The correction of the Euler-angle E1 = α, E2 = β, E3 = γ effects the turning of all the
respective co-ordinate systems (head or basic co-ordinate systems) with retention of the
Tool-Centre-Points (TCP).
The turning order here is:
Z old - Y new - Z new
Example of a head co-ord. cartesian program shift using Euler-angles
-Y
+X
α
+X
+Y
β
-Z
+Z
1
-X
-Z
+Z
+Y
-Y
-X
A ng le α = ro ta tio n in Z-a xis
A ng le β = ro ta te to ne w Y-a xis
2
+Z
+Z
-X
+Y
+Y
-Y
-Z
3
+X
γ
+X
-X
-Y
-Z
H e a d c o -o rd ina te s syste m a fte r
turning thro ug h EULER a ng le
A ng le γ = ro ta te to ne w Z-a xis
The EULER angles are entered in 1/10-degree increments:
Point translation cart.
Ei1..6 100% Z1
Sequence: 5
Start pnt:
0
End pnt:11
in 0.1 mm
in 0.1 deg. EULER BASIC
x: 0
E1-R: 0
|| Hand- ||
y: 0
E2-P: 0
|| input ||
z: 0
E3-Y: 0
==========
Execute
RPY
HEAD Teaching Cur-pos
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:8-23
VRS 1
Example of a head co-ord. cartesian program shift using RPY-angles
In English this means that this turning angle follows the movements and directional changes
of the bow of a ship:
Roll
rolling of
Z-axis
Pitch
vertical pitching
Y axis
Yaw
horizontal yawing
X axis
This description should help explain the tool orientation modification options when correcting
the RPY-angle and retaining the TCP at the same time.
It is just the same here as for EULER-angles for the entire co-ordinate systems after the
corrections have been entered in order to turn to the relevant angle for the associated axis:
Z-axis = Roll Y axis = Pitch
X axis = YAW
TC P
X
YA W
Y
Z
R O LL
PITC H
The RPY angles are entered in 1/10-degree increments.
After the [F2] function key is pressed the assignment will change from RPY to EULER and
vice versa.
Point translation cart.
Start pnt:
0
In 0.1 mm
x:0
y:0
z:0
Execute EULER
F1
Page:8-24
F2
Ei 1..6 100% Z1
SEQUENCE:
5
End pnt:
11
in 0.1 deg.
RPY BASIC
E1-R: 0
|| HAND||
E2-P: 0
|| input ||
E3-Y: 0
==========
HEAD TEACH Cur-pos
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F2- F3
Program mirroring
The mirroring of previously programmed sequences or sub-programs can lead to a
considerable reduction in the programming time under certain conditions. The result of
this is that:
• Symmetric parts can be assembled with regards to their longitudinal plane,
• The left as well as the right hand parts can be processed simultaneously (e.g. left
and right side parts) in a production line),
• The same job can be processed in several production lines by different robots.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-25
VRS 1
As a result of the longitudinal symmetry the operating sequence can be mirrored and from
the symmetrically mirrored robot positioned opposite can also be traversed to the
symmetrically aligned tool piece.
The complete mirroring of programmed sequences and sub-programs is only viable:
• When the robot is positioned exactly symmetrically opposite and the marking
position for axis 1 of both robots constitutes an alignment line.
Exception:
An exact rotation of 90, 180 or 270 degrees between both marking positions can
be taken into account and set up by the relevant entry
• When the mirror image alignment of the tool piece can always be brought to
exactly the same position for the corresponding robot.
The reduction in the programming means that the processing sequence for a specific work
piece must only be taught once.
The mirroring level runs as an extension to the marking position for axis 1.
In addition, the manual axes 4, 5 and 6 must be enabled for a mirroring, in order to
guarantee the corresponding correct tool orientation for the mirrored sequence. It must be
guaranteed that the tool has been mirrored symmetrically.
1
2
5
3
4
1
2
3
4
5
Page:8-26
O rig ina lse q ue nce
M irro ring le ve l
M a rking p o sitio n a xis 1 (e xte nd e d )
M irro red se q ue nc e
M irro red se q ue nc e se t in o p p o site d ire c tio n
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
From output menu
Edit more points
F1 = Points transl. according to angles
F2 = Point translation, cartesian
F3 = Program mirroring
F4 = Program transformation
F1
]
!
F2
F3
F4
F5
Press the [F3] function key to jump to the mirroring program menu.
Note:
Please take into consideration that during mirroring the original sequence will be
overwritten by the mirrored sequence.
Before you start the program mirroring, copy the original sequence to a sequence
No. that is not being used. Then it is always possible to return to the original
sequence after the correction has been made.
Program mirroring
Ei 1 - 6 100% Z1
SEQUENCE:
5
Reference seq.no.: 0
Start pnt:
0
End pnt:
11
Offset values for the axes (in 1/10 deg.):
A 1: 0
A 4: -900
A 2: #
A 5: 0
A 3: #
A 6: 0
Execute
Z-axis
En/disable
F1
F2
F3
F4
F5
The current sequence No. as well as the input field for the starting point, end point and offset
values for axes 1 - 6 will be displayed on the screen.
]
Press the [F2] function key. The offset input fields for axis 7 - 12 will be displayed.
Reference sequence No.:
The entering of a reference sequence No. is only required for a transformation or mirroring
with transformation occurring afterwards.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-27
VRS 1
[F3] Enable / Disable
Use the [F3] function key to enable or disable the axes for mirroring.
Free = enable = 0
Blocked = Disable = #
]
Use the [Cursor] keys to position the cursor on the required axis input field
]
Press the [F3] function key in order to enter the # disabling character. Press the key
once more and the "0" enable character will be displayed again.
Example:
A7: #
A8: #
A9: #
A10: #
A11: #
A12: #
Axes 7 - 12 are disabled by the # character.
Start point/end point:
If the cursor is positioned on this input field the points to be mirrored can be entered. Enter
"0" as the start point number in order to mirror an entire sequence. 9999 can be entered for
the end point No. as the correct end point will be set automatically.
Axes offset value:
A specific value can be pre-entered here, because a modification to the marking position
must be taken into account when mirroring.
Example using axis 4:
Here the marking position of a certain type of robot can be offset by 90 degrees. An offset
value input might be necessary for axis 1 as well, if the mirrored sequence of the robot is to
be traversed when the marking position for axis 1 is not symmetrically mirrored (offset). In
borderline cases the default value should be retained.
[F1] Execute
The mirroring will first be carried out when the entry has been made and the [Return] key
and afterwards the [F1] function keys are pressed.
Press the [F1] function key. The "Mirroring point" report will then be displayed.
Page:8-28
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The respective point numbers from "0" up to the end point will now be displayed.
Program mirroring
Ei 1 - 6 100% Z1
SEQUENCE:
5
Reference seq. no.: 0
Start pnt:
0
End pnt:
11
11
Mirroring point
A 1: 0
A 4: -900
A 2: #
A 5: 0
A 3: #
A 6: 0
Execute Z-axis En/disable
F1
F2
F3
F4
F5
When this process has been successfully carried out twice, the following report will be
displayed:
Program mirroring
Ei 1 - 6 100% Z1
Reference seq. no.: 0
SEQUENCE:
5
Start pnt:
0
End pnt:
11
Mirroring completed !
A 1: 0
A 4: -900
A 2: #
A 5: 0
A 3: #
A 6: 0
Execute
Z-axis En/disable
F1
F2
F3
F4
F5
Tool symmetry for program mirroring
The function "Axis level program mirroring without a reference sequence" which is
implemented in the controller is subject to universal restrictions with regards to the tool
symmetry and the supplying of the tools at the flange of robot axis 6.
The pre-set offset values of the axes are optimised to the conditional mechanical symmetry
characteristics of the equipment.
So when mirroring using these values you will not exceed the software limits (providing the
type specific software limits have not been modified).
So that the mirroring program can be successfully carried out, the necessary symmetrical
requirements must be set up on the tool (e.g. spot welding gripper).
In the ideal case the tool possesses symmetric and mirroring levels.
The TCP now lies in the symmetric level. With mirrored asymmetrical tools you must expect
increased problems.
In order to be able to work with the pre-set offset values of the axes, the tool must be brought
to the robot flange at its mirrored level, so that the tool symmetry level is identical with the X Z levels of the head co-ordinate systems. From the above mentioned TCP position it can be
seen that no tool offset (TCP-Offset) will be given for the Y-direction of the head co-ordinate
systems.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-29
VRS 1
If the tool being used was in fact mirrored symmetrically, but was not brought up to the head
so that the symmetric level of the tool concurred with the X, Z levels of the head systems, the
following procedures can be used:
In the diagram the schematic image is taken from the front of the tool flange of axis 6. The X
and Y co-ordinate directions of the head co-ordinate systems are indicted. The Z direction
points vertically down from the level of the drawing. Also indicated is the cutting line for the X
- Z levels of the head co-ordinate systems. The cutting line for the tool symmetrical level,
which turns through angle ϕ, is also shown for this level. The angle value must be entered as
an offset value for axis 6.
XK
X-Z-le ve lo f the
to o lfla n g e
fo r a xis 6
ϕ
YK
Sym m e tric a lle ve l
o f the to o l
Calculation
ϕ: provided that X ≠ 0
ϕ = a tan (Y/X)
Due to the offset in axis 6, it is possible that the mirrored program will find some points
outside the software limits with reference to axis 6. However as axis 6 is not mechanically
restricted, the software limit for axis 6 can be shifted.
If the value is positive, the upper software limit for axis 6 must be increased. With a negative
value, the lower software limit must be shifted.
Page:8-30
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Program transformation
Hand-F1-F2-F4
By using program transformation a (3-D) shift with turning of a programmed sequence in the
area can be marked. This is only valid within the robot's operating area when the orientation
to the tool piece remains the same. The transformation is used for program shifts in addition
to the cartesian shifts as well as when a turning of the sequence is necessary. The
calculation of the location and position of the "new" (transformed) sequence will depend on:
• Three reference points on the tool piece in the original location and
• Three reference points on the tool piece after the location has been turned and/or
shifted.
The quality of a transformation, i.e. the possible use of the transformed sequence is solely
dependent on the exact teaching of these 6 reference points. The quality of the
transformation displayed after the calculation has been made should not have a value less
than 95 %. Otherwise the reference points must be taught again, in order to enable a new
calculation to be carried out.
0
2
1
3
4
5
07.03.02
Elektroplanung-und Anlagenbau
Page:8-31
VRS 1
Teaching the original part sequence.
]
Mark the 3 reference points on the original part (point-Nos. 0, 1 and 2)
]
Save the new points in an unused sequence (reference sequence).
]
Copy the original sequence and the reference sequence to a disc and if necessary,
read this into another robot system.
]
You must mark the 3 reference points for the "new part" in exactly the same
positions used for the 3 reference points on the original part (point-Nos. 3, 4 and 5)
for the teaching and save them in the reference sequence in each case.
]
Select the "Complete program: Geometry" function. The following menu will be
displayed:
Edit more points
F1 = Points transl. according to angles
F2 = Point translation, cartesian
F3 = Program mirroring
F4 = Program transformation
F1
]
F2
F3
F4
F5
Press the [F4] function key in order to select the program transformation. The
following menu will be displayed:
Program transformation
Ei 1 - 6 100% Z1
Reference seq. no.: 0
SEQUENCE:
5
Start pnt:
0
End pnt:
11
In 0.1 mm
in 0.1 deg.
RPY BASIC
x:0
E1-R: 0
|| HAND ||
y:0
E2-P: 0
|| input ||
z:0
E3-Y: 0
==========
Execute EULER Calculate Teaching Cur-pos
F1
F2
F3
F4
F5
]
Enter the reference sequence-No.
]
Press the [F3] function key. The options for the transformation will be checked.
If a transformation is not possible an error report will be displayed. Otherwise the following
report will be displayed:
The transformation has been calculated
Accuracy factor: 98 %
Import transformation?
YES
F1
Page:8-32
NO
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
If the accuracy factor lies under 95%, the process should be aborted.
]
If the accuracy factor lies above 95%, you can carry out the transformation.
]
Use the [F1] function key to accept the reference sequence for the following
transformation. The output menu will be displayed.
]
Press the [F1] function key again in order to carry out the transformation.
The transformed point numbers will be displayed on the screen one after the other.
The current sequence will be overwritten by the transformed sequence.
]
Use the [F5] function key to abort the transformation. The output menu will then be
displayed.
The following report is displayed after a successful transformation:
Ei 1 - 6 100% Z1
Program transformation
SEQUENCE:
5
Reference seq. no.: 0
Start pnt:
0
End pnt:
11
Transformation completed !
x : 519
E1-R: 0
|| HAND||
y : -360
E2-P: -5
|| input ||
z : 180
E3-Y: 80
==========
Execute
EULER Calculate Teaching Cur-pos
F1
F2
F3
F4
F5
[F2] EULER / RPY
Use the [F2] function key to change the displayed screen from RPY to EULER and vice
versa and also the input field assignment for the angle details.
[F4] TEACHING/HAND
Use the [F4] function key to select between the hand and teaching inputs. The selected
function will be displayed on the screen. If additional corrections are required before the
actual transformation, these can be carried out via the Hand-inputs or in Teaching.
Hand entries:
Here the cursor can be positioned on the relevant input field and the correction value can be
entered. This will then be displayed on the screen.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-33
VRS 1
Entering the teaching:
After the drive system has been switched on, the TCP can be brought to the additional
correction position via cartesian movements. The traversed detour will be displayed on the
screen. During the entering of the teaching, the [F5] function key is assigned "0"; i.e.
pressing this results in the displayed value being deleted.
Program transformation
Ei 1 - 6 100% Z1
SEQUENCE:
5
Reference seq. no.: 0
Start pnt:
0
End pnt:
11
In 0.1 mm
in 0.1 deg.
RPY BASIC
x : 519
E1-R: 0
|| Teaching||
y : -360
E2-P: -5
|| input ||
z : 180
E3-Y: 80
==========
Execute
EULER
HAND
Cur-pos
F1
F2
F3
F4
F5
[F5] Cur-pos. / ZERO
Use the [F5] function key to display the current position in X, Y and Z directions as well as
the EULER or RPY angles. During the teach-entering, the function key operates as a delete
key.
Page:8-34
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Mirroring and transformation
The combination of mirroring and transformation can be used to considerably reduce the
programming requirements for the same tasks, as well as for asymmetric alignment of the
robot or tool pieces.
Application:
Due to the symmetrical length of the bodywork construction, the operating sequence for a
right hand part can be mirrored and then used for the processing of the left hand part.
In only a few applications is the position of robot A to the original tool piece identical to the
position of robot B to the mirrored tool piece.
For this reason the mirroring must be followed by a transformation, so that the mirrored tool
piece can be processed exactly.
Furthermore, the possibility exists that conventional operating sequences plus the reference
sequence (point-Nos. 0, 1 and 2) only have to be programmed once and these can then be
executed from any robot.
A
ar
kin
g
lin
e
fo
r
ax
is
1
The adjustment is made via the function transformation or with symmetrically mirrored parts
via a combination of mirroring and transformation. The teaching of reference points 3, 4 and
5 of the reference sequence is required for the calculation.
M
B
M a rking line fo ra xis 1
07.03.02
M a rkin g p o sitio n fo r
a xis 1 is no t sym m e tric a l
Elektroplanung-und Anlagenbau
Page:8-35
VRS 1
Complete program: additional information
Hand-F1-F2-F3
By selecting this function you can specify for which point sequence of the current sequence
an automatic correction of the relevant additional information should be carried out.
]
Select the "Complete program: additional information" function. The following menu
will be displayed:
Hand Î Teaching Î EDIT
SEQUENCE:
5 Pnt: 0
from point:
to point:
Edit
PLC
Motion
params.
F1
F2
Interpolation
Tool
Weaving number
F3
F4
F5
The cursor blinks in the "from point" input field.
!
]
Enter the required point number. If the entire sequence has to be corrected, enter
from point '0' up to point 9999'. The last programmed point-No. will be displayed
instead of 9999.
]
Confirm the entry by pressing the [Return] key
]
Enter the last point No. of the range in the "up to point" input field.
]
Confirm the entry by pressing the [Return] key
]
By using the respective [F1] - [F5] function keys you can select the additional
information method to be corrected.
Each additional information correction will only take affect when in the respective menu
is finalised by pressing the function key marked "Execute".
Page:8-36
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
If no entries have been made for the start or end points in this menu or have been forgotten,
the following error reports will be displayed when the correction is executed:
Sta rt p o int ha s no t b e e n e nte re d !
End p o in t ha s no t b e e n e nte re d !
Ra ng e ha s no t b e e n d e fin e d !
C o nfirm
C o nfirm
C o nfirm using ESC / M O S:
The last report will be displayed when the either the start or the end points are entered.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-37
VRS 1
Hand-F1-F2-F3-F1
PLC instruction programming corrections
The following menu will be displayed after pressing the [F1] function key:
Hand Î Teaching Î EDIT
SPC TEACHING
MC>
TRAVERS.
CONDIT.
Execute
F1
]
F2
F3
F4
F5
Press the [F3] function key in order to enter the traversing conditions.
Hand Î Teaching Î EDIT
WAIT
MC>IN POINT = E88 ;
(F1 - F3, Î, Í, ESC, RETURN)
Delete
Insert
Edit.
F1
F2
F3
F4
F5
The traversing conditions that are relevant for the selected point can now be programmed
here.
Read the "PLC traversing conditions" section in chapter 9 "PLC programming" for
more information regarding this.
]
Close the entering of the traversing conditions by pressing the [Return] key.
]
Press the [F1] function key in order to execute the correction for the previously
entered range
or
]
Press the [Esc] key to abort the process.
Page:8-38
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F2-F3-F2
Traversing parameter programming corrections
The following are covered by the traversing parameters:
• Trajectory velocity Vb,
• End velocity Ve,
• Start acceleration Aa,
• End acceleration Ae,
• Filter (jerk) or return,
• Accuracy.
]
The following menu will be displayed after pressing the [F2] function key.
Ei 1 - 6 100 % Z1
Hand Î Teaching Î EDIT
SEQUENCE: 5
Pnt: 0 PTP
Vb: 100 %
Ve: 100 %
Aa: 100 %
Ae: 100 %
Jerk: 100 %
Toler.: 200 1/10 deg.
Execute
F1
]
]
Vb
Ve
Toler
F2
F3
F4
Continue
F5
Use the [F5] function key to display the other parameters.
Execute
Aa
Ae
Jerk
Continue
F1
F2
F3
F4
F5
Press the relevant function key (e.g. F3) to display the "active" identifier in the
display field.
Execute
Aa
Ae
Active
Filter
Continue
F1
F2
F3
F4
F5
]
Now select the traversing parameter (switch on "active") that you want to correct.
]
Enter the correction value for the traversing parameter that you have just switched
to "active".
]
Confirm the entry by pressing the [Return] key.
]
Press the [F1] function key in order to correct the activated additional information in
all points (that were entered in the main menu under "from point up to point").
07.03.02
Elektroplanung-und Anlagenbau
Page:8-39
VRS 1
Hand-F1-F2-F3-F3
Interpolation method programming corrections
The following menu will be displayed after pressing the [F3] function key:
Hand Î Teaching Î EDIT
Ei 1 - 6 100 % Z1
SEQUENCE: 5
Pnt: 0
PTP
0
from point:
11
to point:
Edit
]
PTP
LIN
SPL
F1
F2
F3
F4
F5
Use the [F1] - [F3] function keys to select the required interpolation method.
When making a correction from PTP to LIN a trajectory check will be carried out for the point
displayed on the screen.
If no errors are displayed, the function key assignments will be changed.
]
Press the [F1] function key in order to execute the corrections to the interpolation
methods.
Hand-F1-F2-F3-F4
Weaving parameter programming corrections
The following menu will be displayed after pressing the [F2] = Weaving function key:
Hand Î Teaching Î EDIT Ei 1 - 6
SEQUENCE:
5 Pnt: 0
Weaving parameters
Shape
0
: no weaving
Amplitude 0
: [in 1/10 mm]
Period
0
: [in 1/10 mm]
Opening
0
: [in 1/10 mm]
Plane
0
: [in 1/10 Grd]
F1
F2
F3
F4
100 % Z1
Execute
F5
The cursor blinks beneath the first input field for the weaving parameter.
]
Enter the correction.
]
Press the [Return] key.
]
Press the [F5] function key in order to correct the additional information in all points
(that were entered in the main menu under "from point up to point").
Page:8-40
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F2-F3-F5
Programming Tool No. corrections
The following menu will be displayed after pressing the [F5] function key:
Hand Î Teaching Î EDIT
SEQUENCE:
5 Pnt: 0
Tool :
Ei 1 - 6
100 % Z1
1
Execute
F1
F2
F3
F4
F5
The cursor blinks beneath the input field for the tool No.
] Enter the tool number.
]
Press the [Return] key.
]
Press the [F1] function key in order to correct the additional information in all points
(that were entered in the main menu under "from point up to point").
Hand-F1-F2-F4
Editing program names
The following menu will be displayed after pressing the [F4] function key:
Hand Î Teaching Î EDIT
- - - - - - - - - -> Name: SEQ001 <- - - - - - - - - - -
Delete
F1
->[] []-> Ins. / O-W ABCabc
F2
F3
F4
F5
The cursor is positioned on the first letter of the sequence or sub-program name.
Function key assignments:
F1:
Import key (for old hand consoles only).
F2:
Use this function key to delete the entire name.
F3:
copy to the buffer
Shift F3:
Insert in buffer
F4:
toggle: insert / overwrite modes
F5:
toggle: large / small letters
07.03.02
Elektroplanung-und Anlagenbau
Page:8-41
VRS 1
Inserting a TCP
Hand-F1-F3
Previously programmed sequences or sub-programs can be expanded by the insertion of
individual points. You can select whether to make the insertion in front of or behind a
specified point.
If it must be inserted behind the last point, the sequence end (SE) identifier will now be
moved into the inserted point. The inserted point will be automatically assigned additional
information. This will be imported from the point that lies in front or after the inserted point,
depending on the type of insertion.
The following additional information is not imported during inserting:
• Search run
• PLC functions
• Sensor commands
!
Note:
Before each correction operation (e.g. point insertion), copy the original sequence into a
sequence No. that is not being used. Then it is always possible to return to this after the
correction has been carried out.
Read the "Copying sequences to SRAM disc" section in chapter 12 "Service
program" for more information regarding this.
]
Select the [Hand] operating mode
]
Press the [F1] function key
]
Enter the required sequence or S-P No.
]
Press the [F3] function key. The following text will be displayed:
Hand Î Teaching Î EDIT
SEQUENCE : 5 Pnt: 2
Ei 1 - 6
100 % Z1
Insert in front of P 2 !
COORD
POINT+
POINT-
F1
F2
F3
Insert
In front
behind
point
current
F4
F5
The selected sequence or S-P-No. and the current point-No. will be displayed.
In order to insert a point, proceed in the following manner:
]
Press the [F4] function key in order to insert a point in front of the displayed pointNo. or
]
Press the [F5] function key in order to insert a point behind the displayed point-No.
Page:8-42
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Use the [F2] function key for incrementing and the [F3] function key for decreasing
the current point-No.
]
Use [Joystick] or the [Axis traverse] keys to traverse the robot to the required
position.
]
Press the [F1] function key. A point having the current co-ordinates will be inserted.
The following menu will be displayed:
Hand Î Teaching Î INSERT Ei 1 - 6 100 % Z1
SEQUENCE: 5
Pnt: 2
PTP
Vb: 100 %
Ve: 100 %
Aa: 100 %
Ae: 100 %
Jerk: 100 %
Toler.: 200 1/10 deg.
Point was inserted !
PLC
COORDI- InterContinue
polation
--NATES
F1
F2
F3
F4
F5
]
Enter the additional information
]
Traverse the robot using [Joystick] or [Axis traverse] keys to a new position.
]
Press the [F2] function key in order to insert another point having the current coordinates.
or
!
Note:
You must ensure that when "in front of point" is selected, the new point is inserted in
front of the previously inserted point and when "after point" is selected the new point is
inserted behind the previously inserted point.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-43
VRS 1
Modifying additional information
The additional information imported for the new point will be displayed. You can now correct
this additional information:
] Use the [Cursor] keys to position the cursor on the input field.
]
Enter the correction value.
]
Press the [Return] key.
The [F1] - [F5] function key are assigned as follows:
[F1] = PLC functions
[F2] = co-ordinates: inserting other points and importing the current axis coordinates
[F3] = Interpolation
[F4] = Unassigned
[F5] = making other modifications to the additional information
]
The following auxiliary menu will be displayed after pressing the [F5] function key:
Hand Î Teaching Î INSERT Ei 1 - 6 100 % Z1
SEQUENCE: 5
Pnt: 10
S-P connection :
Tool
:
Kinematics
:
1
0
Weave
Sensor
Comment.
Search
Coord.
display
F1
F2
F3
F4
F5
Here you can make further corrections to the additional information of the inserted point or
select further additional information by pressing the relevant function keys.
[F1] = Weaving
[F2] = Sensor
[F3] = Commentary
[F4] = Search run
[F5] = Coordinates display
The description of the individual functions can be found in chapter 7.
Page:8-44
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Inserting in an existing point sequence
The inserted point will automatically receive the programmed additional information from the
point in front (here: from point 4).
The subsequent point numbers will be increased by 1.
p o in t to b e in se rte d
0
1
2
3
4
5
6
Pre vio us
Sub se q .
0
1
2
3
4
5
6
7
Inserting in front of "0"
The inserted point will automatically receive the programmed additional information from the
original point "0".
The subsequent point numbers will be increased by 1.
p o int to b e inse rte d
0
1
2
3
4
5
6
Pre vio u s
Su b se q .
0
1
2
3
4
5
6
7
Inserting behind the last point in the sequence (SE)
The inserted point will automatically receive the programmed additional information from the
original last point. The sequence end (SE) identifier will also be automatically shifted into the
new point.
p o int to b e inse rte d
0
1
2
3
4
5
6 (SE)
Pre vio u s
Su b se q .
0
1
07.03.02
2
3
4
5
6
Elektroplanung-und Anlagenbau
7 (SE)
Page:8-45
VRS 1
Collisions due to insertions
If the running of a sub-program is interrupted, in order to correct a TCP in the operating
sequence by inserting another point, it must be taken into consideration that:
•
•
The TCP with the S-P call remains in existence
The TCP No. of the called up point is not changed (e.g. by inserting)!
Otherwise the robot will no longer traverse in the S-P afterwards, but will traverse directly to
the zero point of the current sequence.
Attention! Danger of collisions!
The robot traverses forwards directly to the "0" point of the current sequence in
Single-Step. Robots, tools, tool pieces or other devices can be damaged or
destroyed by a collision. Select a reduced traversing velocity (max. 10%) and
pay special attention to the possibility of collisions.
Example:
Modifying the operating sequence using sub-program jumps
Here the S-P will be interrupted and in inserted in the operating sequence as point 2, so that
the S-P connection point will be given a new point-No. The robot will now traverse to the
sequence zero point because of this.
STA RT
0
D A N G ER O F C O LLISIO N S
6 “SE”
C a llS-P
2
1
2
3
5
4
3
5
4
7 “SE”
6
ne w
N e w ly inse rte d
Po in t “0 ”
3 “SE”
SUB-PRO G RA M
1
2
Page:8-46
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F4
Deleting a TCP
The deleting is always carried out in the current sequence, i.e. in the sequence selected in
the "Teaching" or in [Automatic] or Single Step operating mode functions.
]
The following menu showing the current sequence-No. and point-No. will be
displayed after selecting "Delete" function:
Hand Î Teaching Î DELETE
SEQUENCE: 5
Pnt: 10
F1 = Single point
F2 = Complete program
F3 = All programs
Point
F1
]
!
SQ/S-P
All
F2
F3
F4
F5
Use the [F1] - [F3] function keys to select the range with which to delete.
Note:
Before deleting, copy the individual or multi-points of the original sequence into a
sequence-No. that is not being used. Then it is always possible to return to this after the
correction has been carried out.
Read the "Copying sequences to SRAM disc" section in chapter 12 "Service
program" for more information regarding this.
Hand-F1-F4-F1
Deleting the current TCP
The current TCP can be deleted directly.
]
Press the [F1] function key. The following menu showing the current sequence- and
point-Nos. will be displayed.
]
Press the [F2] function key in order to display the current point for deleting. All
subsequent points will be moved backwards.
Hand Î Teaching Î DELETE
SEQUENCE: 5
Pnt: 10
Delete
Point
F1
07.03.02
from point :
to point :
10 has been deleted!
Delete
Delete
from/upto
cur-pnt
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:8-47
VRS 1
Hand-F1-F4-F1
Deleting a specific TCP
Should you want to delete an individual point that is not the current point, then you must
enter the same point No. for deletion in the "from point up to point“ input field.
] The point is deleted by pressing the [F4] function key.
Hand-F1-F4-F1
Deleting: from one point-No. to another point-No.
A point group that is no longer required can be deleted as a block. The start and end Nos. for
the points to be deleted must be entered in the "from point up to point“ input field (e.g. from
point 33 up to point 36).
]
Use the [Cursor] keys to position the cursor in the relevant input field.
Hand Î Teaching Î DELETE
SEQUENCE: 5
Pnt: 10
Delete
P
from point : 33
to point : 36
33 up to P 36 deleted!
Delete
Delete
from/upto
cur-pnt
F1
F2
F3
F4
F5
]
Enter the required point numbers.
]
Press the [F4] function key. The points will be deleted and the following points reset
to this position.
Exceptions:
1. One of the points to be deleted is the destination of a program jump
2. One of the points to be deleted is a component part of a circle
If this occurs, a warning report will be displayed in a special menu.
The point will not be deleted until the delete command has been confirmed by pressing the
[F1] function key.
Hand Î Teaching Î DELETE
Point: 36
You will delete junp destinations !
!
]
Delete = YES = F1
NO = ESC
F1
F3
F2
F4
F5
After deleting you must ensure, via correcting or inserting, that the jump destination
or the circle point can be recovered in order to reach the required program run.
Press the [Esc] key to abort the deletion.
Page:8-48
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F4-F2
Deleting an entire program (sequence)
In this menu the current or a freely selectable sequence can be completely deleted.
Hand Î Teaching Î DELETE
SEQUENCE: 5
Pnt: 10
F1 = Single point
F2 = Complete program
F3 = All programs
Point
SQ/S-P
All
F1
F2
F3
F4
F5
]
Press the [F2] function key. Only the automatically displayed current sequence or SP will be deleted.
]
In order to prevent an accidental deletion, you must confirm the function once again.
Press the [F1] function key to confirm the function.
Delete this sequence?
Delete YES = F1
F1
F2
NO = ESC
F3
F4
F5
]
If the [Esc] function key is pressed, the deleting will not be executed. The delete
menu will continue to be displayed.
]
Should another sequence have to be deleted, press the [Esc] function key in order
to return to the teaching menu.
]
Enter the required sequence-No.
]
Confirm the entry by pressing the [Return] key. This sequence will then become the
current sequence and can now be deleted using the delete function.
07.03.02
Elektroplanung-und Anlagenbau
Page:8-49
VRS 1
Hand-F1-F4-F3
Deleting several programs (sequences)
In this menu you will be offered the option to delete just the select sequence or all of the
sequences saved in the controller.
]
The following menu will be displayed by pressing the relevant function key:
Hand Î Teaching Î DELETEÎ All
Sequence: 5
F1=Delete, F2=No del., F3=All, ESC=Abort
Delete
F1
]
Continue
F2
All
F3
F4
F5
Use the [F1] and [F3] function keys to delete:
• Individually selected sequences or
• All sequences simultaneously.
Deleting a selected sequence
With this function you can delete consecutive sequences, whereas specific sequences can
be excluded from this.
]
The current sequence-No. will be displayed on the screen. Press the [F1] function
key to delete the sequence.
]
In order not to delete the displayed current sequence but to switch to the next
programmed sequence, press the [F2] function key.
Deleting all sequences simultaneously
] Press the [F3] function key to delete all of the sequences simultaneously. The
following menu will be displayed:
Delete ALL SEQUENCES?
All = YES = F1 NO = ESC
F1
F2
F3
F4
F5
Press the [F1] function key in order to expressly delete all sequences.
]
If the [Esc] key is pressed the deleting will not be executed. The delete menu will
continue to be displayed.
Page:8-50
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Danger of collisions due to deleting
If the running of a sub-program is interrupted, in order to carry out TCP corrections in the
operating sequence by means of deleting, you must ensure that the TCP having the S-P call
remains in existence and that the TCP No. of the called up point is not changed (e.g. via
deleting). Otherwise the robot will no longer traverse in the S-P afterwards, but will traverse
directly to the zero point of the current sequence!
Attention! Danger of collisions!
The robot will traverse forwards directly to the "0" point of the current sequence
in Single-Step. Robots, tools, tool pieces or other devices can be damaged or
destroyed by a collision. Select a reduced traversing velocity (maximum 10%)
and pay special attention to the possibility of collisions.
Example:
Modifying the operating sequence using sub-program jumps
Here the S-P is interrupted and point 2 in operating sequence is deleted, so that the S-P
connecting point now has a new point-No. The robot will now traverse to the zero point of the
sequence because of this!
STA RT
0
D A N G ER O F C O LLISIO N S
6 “SE”
C a llS-P
2
1
2
3
5
4
3
5
4
7 “SE”
6
ne w
N e w ly inse rte d
Po in t “0 ”
3 “SE”
SUB-PRO G RA M
1
2
07.03.02
Elektroplanung-und Anlagenbau
Page:8-51
VRS 1
Page:8-52
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
9. PLC programming
9.
PLC programming ............................................................................... 9-1
The PLC controller ........................................................................................ 9-3
Outputs:.......................................................................................................... 9-3
Inputs:............................................................................................................. 9-4
General information regarding PLC programming ..................................... 9-5
PLC operators................................................................................................ 9-6
PLC-inputs and outputs ................................................................................ 9-9
PLC-inputs ................................................................................................... 9-11
PLC-outputs ................................................................................................. 9-11
PLC outputs ................................................................................................. 9-12
Switching on the PLC output...................................................................... 9-12
Switching off the PLC output ..................................................................... 9-13
Linking to an PLC output ............................................................................ 9-13
Inserting, correcting and deleting PLC lines: ........................................... 9-16
Inserting other links within the same line ................................................. 9-17
Correcting links within a line...................................................................... 9-21
Deleting links within a line.......................................................................... 9-22
Deleting an operand: ................................................................................... 9-22
Deleting an operator: .................................................................................. 9-23
PLC macros.................................................................................................. 9-24
Programming PLC macro calls .................................................................. 9-24
Displaying the PLC macro contents .......................................................... 9-25
PLC - wait conditions (WAIT)..................................................................... 9-26
PLC - gripper functions............................................................................... 9-29
Programming "QUICK" gripper functions ................................................. 9-30
Gripper and interbus docking function ..................................................... 9-31
PLC - flags.................................................................................................... 9-33
Switching PLC flags on and off and linking .............................................. 9-34
PLC - static flags ......................................................................................... 9-35
PLC arithmetical verification ...................................................................... 9-36
PLC markers ................................................................................................ 9-38
Switching on and off / linking PLC markers.............................................. 9-39
PLC - counter (arithm.)................................................................................ 9-41
PLC-counter programming ......................................................................... 9-42
PLC-timer ..................................................................................................... 9-46
PLC-timer in a point related PLC................................................................ 9-47
PLC-timer in a free running PLC ................................................................ 9-47
Timer value allocation................................................................................. 9-48
Starting / stopping the timer....................................................................... 9-49
PLC timer flag T ........................................................................................... 9-51
PLC-binary outputs ..................................................................................... 9-52
PLC binary output allocation...................................................................... 9-54
Analog output .............................................................................................. 9-58
Basis ............................................................................................................. 9-58
Programming the analog output ................................................................ 9-59
Compatibility................................................................................................ 9-61
PLC jump command .................................................................................... 9-62
Programming a jump command:................................................................ 9-62
Switching on a jump command:................................................................. 9-63
07.03.02
Elektroplanung-und Anlagenbau
Page:9-1
VRS 1
Switching off a jump command: ................................................................ 9-63
In order to link jump commands, proceed as follows: ............................. 9-63
PLC traversing conditions (TC).................................................................. 9-66
Programming ............................................................................................... 9-67
PLC jump conditions (JC)........................................................................... 9-69
Jump types................................................................................................... 9-70
Executing a jump ......................................................................................... 9-70
Sub-programs (S-P)..................................................................................... 9-71
Sub-program calls ....................................................................................... 9-71
What are relative S-Ps?............................................................................... 9-71
Relative 1...................................................................................................... 9-72
Relative 2...................................................................................................... 9-73
Special .......................................................................................................... 9-74
Calling up sub-programs ............................................................................ 9-74
Trajectory switching functions (TS)........................................................... 9-76
Boundary conditions and limitations......................................................... 9-77
Programming ............................................................................................... 9-81
The free running PLC .................................................................................. 9-86
Editing free running PLC programs [F1]: .................................................. 9-87
Copying free running PLC programs......................................................... 9-88
Deleting free running PLC programs ......................................................... 9-89
Setting the cycle time.................................................................................. 9-89
Starting a free running PLC program......................................................... 9-90
Stopping the free running PLC programs ................................................. 9-91
PLC operands .............................................................................................. 9-92
Page:9-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The PLC controller
PLC (SPC) = Stored Program Control forms an automatic system for controlling, monitoring,
collecting data and processing it as well as providing communications and other process
related tasks.
The controller operates via an integrated mini-PLC, i.e. this stored program controller does
not exist as a customary additional hardware module, but the PLC instructions are executed
by the controller as point related or free running instructions in the [Automatic] and [Single
Step] operating modes and in the integrated hardware that is being used.
PLC fun c tio ns
Entra nc e
M a rke r
Tra ve rsing
c o n d itio n
Fla g
Jum p
c o n d itio n
Exit
To o l
Tim e r
Jum p
d e stina tio n
W a it
c o n d itio n
Bin a ry
o utp ut
A rith m .
ve rific a tio n
PLC
m a c ro
C o unte r
This can basically be divided between two different types of PLC programming:
1) Point related PLC programs
The PLC instructions are bound to a TCP that the robot must traverse to. This means that
the PLC action will only be executed in the point in which they have been programmed. Point
related PLC instructions could be set to interrogate to a specific TCP status or execute
actions (e.g. switching an adhesive pistol on and off).
Outputs:
Are processed in a programmed point or by the trajectory switching function.
Read the "Trajectory switching functions" section in this chapter for further
information regarding this.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-3
VRS 1
Inputs:
Can be point related or continuous, i.e. read and processed on the path between 2 different
points.
The point related PLC would be started when the TCP enters the programmed accuracy ball
of the associated TCP.
Sta rt the p o int re la te d PLC
TC P to be tra versed to
Ac cura cy b a ll
Ve > 0
End
ofcreep
r
Accuracy
radius
Sta rt the p o int
re la te d PLC
Start creep
If an accuracy ball has not been programmed (accuracy=0) for the point, the point related
PLC starts when the TCP reaches the programmed destination point.
When the drive system is switched off the PLC will be stopped and will continue onwards to
the interrupted position after the [Drive ON] keys are pressed. After the interruption, the
previous conditions will not be checked again.
The point related PLC instructions are programmed for new teaching, correcting or inserting
of TCP's.
2) Free running (asynchronous) PLC programs
The PLC instructions are processed cyclically here. All programmed inputs and outputs are
permanently interrogated and updated. The free running PLC program is used to monitor and
to control point independent system statuses (e.g. for full status monitoring of adhesive
supply containers).
The current free running PLC program will be started by selecting [Automatic] or [Single
Step] operating modes and only stopped by an operating mode change.
The programming of a free running PLC programs is carried out using constant type 490.
In the following pages the programming of the PLC functionality's will be explained to you
together with examples of point related PLCs. However, unless otherwise stated, these
examples can also be used for the free running PLCs.
Please read the "The free running PLC" section in this chapter for more information
regarding the special features of free running PLCs.
Page:9-4
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
General information regarding PLC programming
The PLC instructions can be programmed for the relevant movement sequence for new
teaching, correcting or inserting of TCP's. After teaching the co-ordinates for a TCP, the PLC
instructions for this point can be entered.
The following screen is displayed after selecting a previously programmed sequence:
Ei 1 - 6 100 % Z1
Hand Î Teaching Î EDIT
SEQUENCE: 5
Pnt: 10
PTP
Vb: 100 %
Ve: 100 %
Aa: 100 %
Ae: 100 %
Jerk: 100 %
Toler.: 200 1/10 deg
PLC
---
F1
]
COORDI- Interpolation
NATES
F2
Next
point
Continue
F4
F5
F3
Press the [F1] function key. The PLC teaching menu will be displayed:
Sequence: 5
TC
JC
S-P
TS
1>
OUTPUT MACRO
F1
F2
Pnt:
10
WAIT
PLC-TEACHING
GRIPPER Continue
F3
F4
F5
]
After pressing the relevant [F1 - F4] function key, you will jump to the respective
function.
]
Other functions will be displayed after pressing the [F5] function key:
FLAG
ARITH
VERIF:
MARKER
F1
F2
F3
F4
F5
BINARY
ANALOG
Continue
F2
F3
F4
F5
JUMP
IBM Dock
F2
F3
COUNTER TIMER
F1
JUMP
mark
F1
]
Continue
Continue
F4
F5
In this menu, menu driven programming of all PLC instructions described in the
following chapters can be carried out.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-5
VRS 1
!
20 PLC lines can be programmed per TCP besides a traversing condition (TC), a jump
destination (JC), sub-program calls (S-P‘s) and trajectory switching functions (TS).
Under certain circumstances this can result in computing time problems involving the
execution. If so, the constant 556 "Maximum PLC loading" must be corrected.
More information regarding this constant can be found in chapter 14 "Modifying the
constants".
4 or 8 PLC lines are displayed on the screen depending on which hand console model is
connected. The [>] pointer identifies the valid line.
]
Use [Cursor UP] and [Cursor DOWN] keys to move the cursor to the required line.
If more than 4 or 8 lines are entered, the pointer on the screen will move to the top for each
new line to be entered, i.e. the upper line is no longer displayed (scroll function).
]
Use [Cursor UP] and [Cursor DOWN] keys to select the required line to be redisplayed on the screen.
PLC operators
The following logical operations are available for use in order to link individual components
(operands):
Equal
• AND
&
=
!
+
Unequal
• OR
!
<
Smaller than
• NOT
/
>
Greater than
• Divided by
The characters (operators) with the grey backgrounds can be entered in the respective PLC
function via the function key.
Concept:
Logic:
Logical 1 = 'voltage present‘ or 'condition fulfilled‘
Logical 0 = 'voltage not present‘ or 'condition not fulfilled‘.
Set:
Means that an output will be set to logical 1, i.e. the relay contact of the relevant relay
will be closed.
Clear:
Means the opposite of set, i.e. the relay contact of the relevant relay will be opened.
Page:9-6
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Example:
The output O10 should be initially set when a voltage is present at input I12 (= log. 1 = ON).
Written as:
O10 = I12.
Output O10 will be set when input I12 is a log. 1.
O 10 = I12
I1 2
O 1 0 is se t
O 10
O 10 = I12
I1 2
O 10 is no t se t
O 10
M ISSIN G (N O T) (!)
The e ffe c t o f the N O T link (ne g a te s the o p e ra nt)
is th a t the c o nd itio n ha s b e e n fulfille d w he n
the lo g ic a lsta tus o f the o p e ra nt = O UT.
Exa m p le : O 1 w illb e se t w h e n I3 = N O T O N
I3
O1
Pro g ra m m e d : O 1 = ! I3
O 10 = ! I1 2
I1 2
O 10 is se t
O 10
O 10 = ! I1 2
I1 2
O 10 is no t se t
O 10
07.03.02
Elektroplanung-und Anlagenbau
Page:9-7
VRS 1
A N D (& )
The A N D link ist first fulfille d : w he n the a sso c ia te d
c o m p o ne nts (o p e ra nts) a re p ro g ra m m e d
a s re q uire d a nd ha ve a lo g ic a lsta te .
Exa m p le : O 1 w illb e se t w h e n I1 & I2 & I3 & In = O N
I1
I2
I3
In
O1
Pro g ra m m e d : O 1 = I1 & I2 & I3 & In
O R (+ )
The
(o p e ra nt) is p ro g ra m m e d
a s re q uire d a nd ha s a lo g ic a lsta te.
Exa m p le : O 1 w illb e se t w h e n I1 + I2 + I3 + In = O N
I1
I2
O1
I3
In
Pro g ra m m e d : O 1 = I1 + I2 + I3 + In
The following is valid for mixed links:
AND (&) goes before OR (+)
Page:9-8
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
PLC-inputs and outputs
Inputs and outputs are required, in order to pass commands and signals from the controller
to the process and vice-versa, e.g. gripper OPEN / CLOSE, profile free, end of job, lock the
robot etc.
There are three methods of updating:
• I / O card:
There are 16 optical coupler inputs available per I/O card. The input signal (24V =) must
be set for at least 20 ms, in order to guarantee safe processing.
Controller
I1
I16
O1
O16
Optical coupler
1 2 3 4 5 6 7 8 N1
9 10 11 12 13 14 15 16 N 2
I1
1 2
31 32
O1
O16
I16
External voltage 24V
Voltage free (2A)
16 Outputs
16 Inputs
•
Interbus Slave – card 5-E-563:
A maximum of two cards can be installed. There are 64 inputs and outputs available per
slave card, which communicate with the PFC via the LWL. Furthermore, the optical
coupled I / O can be also be used in the normal way.
Controller
I1
I16
O1
I/O
O16
Optical coupler
Slave bus
+
1 2 3 4 5 6 7 8 N1
9 10 11 12 13 14 15 16 N 2
I1
I16
External voltage 24V
16 Inputs
07.03.02
1 2
31 32
O1
O16
Voltage free (2A)
IBM slave
16 Outputs
Elektroplanung-und Anlagenbau
Page:9-9
VRS 1
Interbus master/slave card 5-E-1494:
Up to 992 inputs and outputs, which are logically linked via the PLC instructions, can be
processed using the interbus master/slave card. These inputs and outputs are “Memory
mapped” first, i.e. so that the internal PLC in the control system processes the inputs and
outputs in the CPU memory first. The input and output systems administer the physical I/Os.
When the controller is booted up, it checks to see which I/O hardware is available for use.
!
Important information:
The physical inputs are no longer polled if a master / slave card is being used.
I/O
Slave bus
IBM
master/slave
card
Master bus
I/O
Page:9-10
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
PLC-inputs
Commands from the peripheral devices are sent to the controller via the inputs (physically
from the PLC I/O-card, or via the interbus).
These are:
• Select the working sequence to be run
• Report: new part placed in device
• Feedback information: gripper is OPEN / CLOSED, etc.
Up to 992 inputs (I1 – I992), which are logically linked via the PLC instructions, can be
processed using the interbus master/slave card. The PLC can also poll and process inputs
that are active low.
!
Important information:
The physical inputs are no longer polled.
PLC-outputs
Commands from the controller are passed via these outputs to the process peripheral
devices, e.g. reports regarding the production facility controller (PFC), tool-piece commands,
sequence controlling conditions, etc.
The PLC can process a maximum of 992 outputs (A1 – A992), depending on the type of
installation.
These outputs can be set or deleted directly or the setting can depend on logically linked
operands (inputs, markers, flags) via the relevant PLC-instructions.
!
Important information:
The physical outputs are no longer polled.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-11
VRS 1
Sequence selection:
The I1 - I8 inputs are provided for the selection of the sequence No.
a)
1 from n
(sequence Nos. 1 - 8)
b)
Binary
(sequence Nos. 1 - 127) (7bit, odd parity)
Sequence 0 is not permitted.
The robot controller checks the plausibility of the input settings:
a)
If 1 from n is selected then you are only permitted to set one input, otherwise the error
report: "Mistake setting sequence No.“ will be displayed.
When binary is select a check will be made to see whether there is an uneven number
of set inputs and the parity input will also be checked.
b)
PLC outputs
Hand-F1-F2-F1-F1-F1
Commands from the controller will be sent to the processing peripherals via these potential
free outputs, e.g. reports for the operating material control (OMC), tool commands,
incremental switching conditions etc.
Depending on the installation the PLC can process up to a maximum of 128 outputs (O1 O128).
There are 16 opto-coupled inputs in the form of relay contacts available for use per I/O
board. A 2A miniature fuse protects each contact.
These outputs can be set or cleared directly depending on the logically linked operands
(inputs, markers, flags) via the relevant PLC instructions.
Switching on the PLC output
The programming of the outputs requires that the co-ordinates for the TCP have been
correctly taught.
In this example sequence No. 5 PLC functions will be programmed in point No. 10.
]
Press the [F1] function key to display the PLC teaching menu.
Sequence: 5
TC
JC
S-P
TS
1>
OUTPUT MACRO
F1
Page:9-12
F2
Pnt: 10
WAIT
F3
PLC-TEACHING
GRIPPER Continue
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Press the [F1] function key in order to program an output.
]
Enter the output No. (No.: 13 in this example).
]
Confirm the entry by pressing the [Return] key. The PLC outputs menu will be
displayed.
Pnt: 10
Sequence: 5
TC
JC
S-P
TS
1 > O13
(F1 – F3, ESC)
SW-IN
SW-OUT
LINK
F1
F2
F3
PLC-TEACHING
F4
F5
]
Press the [F1] function key in order to switch in the PLC program line with the output
O13. The PLC line is then closed and the PLC teaching menu will be displayed on
the screen.
]
After this the pointer will be positioned on the next free input line input line (2), in
which you can enter other PLC instructions by using the [F1] - [F5] function keys.
Switching off the PLC output
The procedure for switching off an PLC output is identical to the programming of the
switching on.
]
Press the [F1] function key in order to program an output.
]
Enter output No.
]
Press the [Return] key to close the entry.
]
Press the [F2] function key to switch off the PLC programming line with the O13
output.
Linking to an PLC output
The effect of linking an output is that this will first be set to ON or OFF only when the relevant
condition has been fulfilled.
Example:
The output 20 must be linked to input 13, i.e. O 20 should only be set to ON when I13 = ON.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-13
VRS 1
Proceed as follows in order to link an output:
]
Press the [F1] function key in order to program an output.
]
Enter output No. (e.g. 20).
]
Confirm the entry by pressing the [Return] key.
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > O20
(F1 – F3, ESC)
SW-IN SW-OUT
LINK
F1
]
F2
F3
COR. No.
F4
F5
Press the [F3] function key in order to link the output with another operand.
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > O20 = ?
(F1 – F3, ESC)
Delete
Insert
Edit
F1
]
PLC-TEACHING
F2
F3
PLC-TEACHING
F4
F5
Press the [F3] function key in order to edit an input field marked with [?].
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > O20 = ?
Please enter an operand (F1 – F5)
I
M
F
O
Continue
F1
F2
F3
F4
F5
]
Enter the relevant operand (input, marker, flag, output) via the [F1] - [F4] function
keys.
]
Press the [F5] function key in order to select other operands (sensor flags and timer
flags).
E.g. in order to enter input I 13 as an operand, proceed as follows:
Page:9-14
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Press the [F1] function key (I = input).
]
Enter the input No. (13 in the example above).
]
Confirm the entry by pressing the [Return] key.
Displayed on the screen are the selection options for whether or not the input (operand)
should be negated (negated = NOT ON).
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > O20 =
Negate the operand (!) ? I13
YES
NO
PLC-TEACHING
F1
F4
F2
F3
F5
]
Press the [F1] function key in order to negate the operand or
]
Press the [F2] function key in order not to negate the operand.
In this example you must press the [F2] function key. Consequently output 20 will be linked
to input 13.
On the screen you will be offered the option of inserting other links.
Sequence: 5
TC
JC
S-P
TS
1 > O20 = I13
(F1 – F3, ESC)
Delete
Insert
F1
F2
Pnt: 10
PLC-TEACHING
Edit
F3
F4
F5
Read the "Inserting other links within a line" section in this chapter for further
information regarding this.
]
If you do not wish to make any more links, press the [Return] key. The PLC teaching
menu will be displayed for entering other PLC instructions.
Outputs can also be used as operands in the PLC instructions:
O4 = O3
output 4 will be switched on when O3 is switched on, otherwise O4 will
remain switched off.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-15
VRS 1
In this example, defective outputs cannot be recognised by being re-read, as the status of O3
will not be read via the hardware. The statuses of all outputs are determined internally via
software.
The performance characteristics for programmed outputs can be set via the "Output
attributes“. Read the "301 output attributes" section in chapter 14 "Modifying the
constants" for more information regarding this.
Inserting, correcting and deleting PLC lines:
This function is activated by pressing the [Cursor Up] / [Cursor Down] keys when the
pointer is positioned on a previously programmed PLC line.
The menu name (PLC-CORRECT) as well as the [F1] - [F5] function key assignments will be
changed by this.
Inserting:
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1>
2 O20 = I13
OUTPUT MACRO
WAIT
F1
F2
F3
PLC-TEACHING
GRIPPER Continue
F4
F5
[F1] inserting
A free input line will be inserted in front of the line where the pointer (>) is presently
positioned. All succeeding line numbers will be increased by 1.
Correcting:
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > O20 = I13
(F1 – F4, ESC)
SW-IN
SW-OUT
LINK
F1
F2
F3
PLC-CORRECT
CORR No.
F4
F5
[F3] Correcting
The required correction can be entered in the line in which the pointer (>) currently lies or has
been positioned.
Page:9-16
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Delete:
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > O20 = I13
COPY to
INSERT BUFFER
EDIT
F1
F2
F3
PLC-TEACHING
DELETE
F4
F5
Press the [F5] function key to delete the entire line on which the pointer (>) is
positioned.
]
Inserting other links within the same line
In the following example the link in a previously programmed output must be expanded.
Example:
O20 = I13
should be expanded to
O20 = I12 & I13 + I14
]
Use [Cursor UP] or [Cursor DOWN] keys to position the pointer on the relevant
PLC line. The function keys are assigned as follows:
Sequence: 5
TC
JC
S-P
TS
1 > O20 = I13
INSERT
F1
07.03.02
F2
Pnt: 10
PLC-TEACHING
EDIT
DELETE
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:9-17
VRS 1
]
Press the [F3] function key in order to modify the PLC line.
Sequence: 5
TC
JC
S-P
TS
1 > O20 = I13
]
PLC-TEACHING
SW-IN
SW-OUT
LINK
CORR No.
F1
F2
F3
F4
F5
Press the [F3] function key in order to insert more links.
Sequence: 5
TC
JC
S-P
TS
1 > O20 = I13
INSERT
F1
]
Pnt: 10
Pnt: 10
PLC-TEACHING
EDIT
F2
F3
DELETE
F4
F5
Ue [Cursor left] or [Cursor right] keys to move the cursor to the next insertion
position.
1
2
Inserting:
> A 20 = E 13 ;
IN FRONT of the I13 operand
BEHIND the I13 operand
As the new I12 operand will be inserted in front of I13, the cursor must be positioned on the
"I" of I13 in the above example.
]
Press the [F2] function key. A free input field will be created in front of the I13 field.
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > O20 = ?
? I13
Please enter an operand (F1 – F5) >
I
M
F
O
Continue
F1
Page:9-18
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
If you wish to enter input 12 as an operand, proceed in the following manner:
]
Press the [F1] function key (I = input).
]
Enter the input No. (12 in the example above).
]
Confirm the entry by pressing the [Return] key.
The inquiry as to whether the operand should be negated will be displayed.
]
For this example, press the [F2] function key, as input 12 does not have to be
negated.
Pnt: 10
Sequence: 5
TC
JC
S-P
TS
1 > O20 = I12 ? I13
Please enter an operator >
& AND
+ OR
F1
F2
F3
PLC-TEACHING
F4
F5
At the moment the operator with which both operands will be linked is missing.
]
In this example, press the [F1] function key.
The AND link will be inserted into the line. The cursor will move one position to the right and
will blink beneath the I (of I13). The [F1] - [F5] function key assignments will be changed at
the same time.
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > O20 = I12 & I13
INSERT
F1
PLC-TEACHING
EDIT
F2
F3
DELETE
F4
F5
]
As the OR link must be made with I14 behind I13, use the cursor keys to position
the cursor behind I13.
]
Press the [Cursor right] key in order to position the cursor on the semicolon (;)
07.03.02
Elektroplanung-und Anlagenbau
Page:9-19
VRS 1
]
After pressing the [F2] function key a new input field will be displayed behind I13,
limited by two question marks.
Pnt: 10
Sequence: 5
TC
JC
S-P
TS
1 > O20 = I12 ? I13 ?
?
Please enter an operator >
& AND
+ OR
F1
F2
F3
PLC-TEACHING
F4
F5
]
Press the [F2] function key in order to link the new operands with the OR function.
]
The required operand (input, marker, flag, output, sensor, timer) can be selected via
the [F1] - [F5] function keys behind the new operator (+).
If you wish to enter input 14 as an operand, proceed in the following manner:
]
Press the [F1] function key = I in the operand menu.
]
Enter the input No. (14 in the above example).
]
Confirm the entry by pressing the [Return] key.
The inquiry as to whether the operand should be negated will be displayed.
]
Press the [F2] function key for this example, as input 14 does not need to be
negated.
The link is now complete.
Page:9-20
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The following screen will be displayed. The cursor blinks on the semicolon behind I14.
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > O20 = I12 & I13 + I14;
Delete
F1
Insert
F2
PLC-TEACHING
Edit
F3
F4
F5
]
Use the [F2] function key to insert other links.
]
If no other links have to be made, press the [Return] key.
The PLC teaching menu for entering other PLC lines will now be displayed.
Correcting links within a line
In the following example an operator must be corrected in a programmed link.
Proceed as follows:
]
Use [Cursor UP] or [Cursor DOWN] cursor keys to position the pointer on the
relevant PLC line.
]
Press the [F3] function key.
]
Press the [F3] function key.
]
Now use the [Cursor left] / [Cursor right] keys to position the cursor on the
operator or operand to be corrected.
If, for example, an AND link has to be modified in an OR link, the cursor must be positioned
on the AND (&) operator.
The following will be displayed on the screen:
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > O20 = I12 & I13 + I14;
Delete
F1
]
Insert
F2
PLC-TEACHING
Edit
F3
F4
F5
Press the [F3] function key in order to correct the operator.
A question mark (?) instead of the old operator (&) will be displayed on the screen. You will
be asked to enter another operator at the same time.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-21
VRS 1
]
Press the [F2] function key in order to select the OR link.
]
Press the [Return] key.
]
Press the [Return] key again in order to import the modifications into the PLC line.
The corrected PLC line will be displayed on the screen or
]
Press the [Esc] key to not to import the modification into the PLC line.
Deleting links within a line
Individual operands can be deleted from a link in an PLC line. Proceed as follows:
]
Use [Cursor UP] or [Cursor DOWN] keys to position the pointer on the relevant
PLC line.
]
Press the [F3] function key twice.
]
Use the [Cursor left] / [Cursor right] keys to position the cursor on the operator or
operands to be deleted.
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > O20 = I12 & I13 + I14;
Delete
F1
Insert
F2
PLC-TEACHING
Edit
F3
F4
F5
Deleting an operand:
] Position the cursor on the operand (e.g. I13) to be deleted.
]
Press the [F1] function key.
The operand positioned to the right of the operator will be deleted.
Example:
Cursor positioned on I13
Before
1>O20 = I13 & I14 & I16 & I18
2
1>O20 = I14 & I16 & I18
2
After
Page:9-22
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Deleting an operator:
] Position the cursor on the operator (e.g. &) to be deleted.
]
Press the [F1] function key.
The operator to the right of the operand will be deleted.
Example:
Cursor on operator
Before
1>O20 = I13 & I14 & I16 & I18
2
After
1>O20 = I13 & I16 & I18
2
If the line is comprised of only 1 operand, it cannot be deleted.
When the relevant operand or operator has been deleted, you can now exit the delete menu.
]
Press the [Return] key.
]
Press the [Return] key once again in order to import the modification into the PLC
line or
]
Press the [Esc] key in order to not to import the modification into the PLC line.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-23
VRS 1
PLC macros
Hand-F1-F2-F1-F1-F2
Up to 99 PLC instructions can be combined in a so-called Macro and saved in the controller
under a macro No.
This offers the advantage that repeated PLC instructions only have to be programmed once
and afterwards can be called up again as an PLC macro at any programmed point within all
of the programmed sequences.
!
Note:
The programmed PLC macros can be called up in both the point related and free
running PLCs.
Up to 200 different PLC macros (M0 - M199) can be programmed.
Another macro can be called up from a macro. The maximum encapsulated depth is limited
to 10.
Macros
Programming (EDIT) or deleting
Read the "330 PLC macros teaching/deleting" section in chapter 14 "Modifying the
constants" for more information regarding this.
Example: Macro 0
O10 = ON
O12 = ON
Gripper 1 = CLOSED
Waiting time 10 sec.
O10 = OFF
O11 = OFF
Wait for I14
Gripper 1 = OPEN
O13 = ON
Programming PLC macro calls
Macros can be called up from both point related as well as free running PLC programs.
Page:9-24
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
The following screen will be displayed after the selecting the PLC menus.
Sequence: 5
TC
JC
S-P
TS
1>
OUTPUT MACRO
F1
F2
Pnt: 10
WAIT
F3
PLC-TEACHING
GRIPPER Continue
F4
F5
]
Press the [F2] function key.
]
Enter the macro No.
]
Confirm the entry by pressing the [Return] key.
The macro call is now programmed and will be displayed on the screen:
Pnt: 10
Sequence: 5
TC
JC
S-P
TS
1 PLC Macro 5
2>
OUTPUT MACRO
WAIT
F1
F2
F3
PLC-TEACHING
GRIPPER Continue
F4
F5
Displaying the PLC macro contents
If a macro call has been programmed in a PLC line, you can display the contents of the
macro.
Proceed as follows:
]
Use the [Cursor up] / [Cursor down] keys to position the pointer on an PLC line, in
which a macro call is to be programmed.
]
The function key assignments will be changed to the following:
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > SPC Macro 5
COPY to
INSERT BUFFER
EDIT
F1
07.03.02
F2
F3
PLC-TEACHING
SHOW
F4
DELETE
F5
Elektroplanung-und Anlagenbau
Page:9-25
VRS 1
]
Press the [F4] function key.
The menu will change to the macro display menu (SHOW MA) and the contents of the
programmed PLC macro will be displayed.
Sequence: 5
1 O12
2 O10
3 O11
4 Wait for
5 Wait for
6>
F1
F2
=
=
=
=
=
Pnt 10
OUT
OUT
IN
!I12 & I11;
!I10;
F3
SHOW-MA 5
F4
F5
When programming more than 4 lines use [Cursor up] / [Cursor down] keys to scroll
around the display area.
The macro will now be displayed. The individual PLC instructions cannot be modified or
enhanced here.
Read the "330 macros teaching/deleting“ section in chapter 14 "Modifying the
constants" for further information regarding the programming of PLC macros.
]
Press the [Esc] key in order to exit the display function.
PLC - wait conditions (WAIT)
Hand-F1-F2-F1-F1-F3
In the PLC there exists two options for stopping the robot's traversing program whilst
retaining permanent control of all axes.
Wait conditions:
• Wait, until the wait time programmed in the relevant TCP has expired (maximum of
9999 1/10 second)
• Wait, until the logical links programmed in the relevant TCP have been set to
"fulfilled".
!
A wait condition is always a fixed link to a TCP and can only be programmed in
point related PLC programs.
Page:9-26
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
If a wait time has been programmed in a TCP, the robot will be deliberately stopped, i.e. the
velocity will be reset to zero at this point.
It will also be stopped when a wait condition from a logical link exists. Only when this has
been set to fulfilled can other succeeding PLC instructions be executed or the robot can
continue with its traversing program.
Online:
So that you do not have to increase the cycle time due to unnecessary braking of the robot
as the programmed wait condition has already been fulfilled in the TCP that is being
traversed to (e.g. wait for contact...), an instruction for the logical link can be programmed
online.
Therefore the wait condition will be checked on the path to this point. If the condition has
already been fulfilled before reaching the accuracy ball for the point, this will then traverse in
accordance with the programming of the accuracy ball.
If the wait condition is only first fulfilled within the accuracy ball, the activated brake ramp will
be released and the point with the programmed velocity will traverse at creep speed.
Both wait times as well as logical links can be programmed in a TCP.
Sequence: 5
TC
JC
S-P
TS
1>
OUTPUT MARK
F1
F2
Pnt: 10
WAIT
PLC-TEACHING
GRIPPER Continue
F3
F4
F5
Application:
• Wait for operating material control
• Setting up times:
•
for inert gas - welding
•
spreading adhesive
•
assembly and fitting tasks, etc.
The following menu will be displayed after the [F3] function key is pressed:
Sequence: 5
TC
JC
S-P
TS
1>
(F2, F4, ESC)
TO
F1
07.03.02
F2
Pnt:
10
WAIT
ONL
TIME
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:9-27
VRS 1
[F2] WAIT UNTIL
] Press the [F2] function key in order to program a wait condition.
]
Press the [F4] function key in order to enter the first link condition.
The further procedures for programming the wait conditions are identical with an PLC output
link.
[F3] Wait ONL
] Press the [F3] function key in order to program an ONLINE wait condition.
]
Press the [F4] function key in order to enter the first link condition.
The further procedures for programming the ONLINE wait conditions are identical with an
PLC output link.
[F4] Wait time
] Press the [F4] function key in order to program a specific wait time in this point.
]
Enter the wait time for which the PLC program will be stopped in this position in 1/10
sec.
]
Confirm the entry by pressing the [Return] key.
!
When programming wait conditions of the wait until and wait time types, the
programmed point velocity Ve will be automatically reset to zero.
Page:9-28
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F2-F1-F1-F4
PLC - gripper functions
The gripper functions are used, for example, to open or close a gripper, to activate welding
gripper or to control external devices (e.g. clamping devices).
The executing of gripper functions is normally linked to a specific TCP in the sequence.
!
The gripper functions can only be programmed in point related PLC programs.
For the following part of the chapter, a precondition is that a gripper type allocation has been
carried out.
Read the "300 gripper instructions" section in chapter 14 "Modifying the constants"
for further information regarding this.
Select the PLC teaching menu for point related PLC in order to program the gripper
functions.
]
Sequence: 5
TC
JC
S-P
TS
1>
OUTPUT MARK
F1
]
F2
Pnt: 10
WAIT
PLC-TEACHING
GRIPPER Continue
F3
F4
F5
Press the [F4] function key in order to program a gripper function. The tool - action
menu will be displayed.
Sequence: 5
TC
JC
S-P
TS
1 > Gripper 1
GRIPPER
F1
Pnt: 10
Closed =
PLC-TEACHING
ON;
LINK
CONDS.
CL/OPEN
F2
F3
F4
F5
[F1] Modifying the gripper-No.
The default selection is normally gripper 1.
In order to modify the gripper-No., proceed as follows:
07.03.02
Elektroplanung-und Anlagenbau
Page:9-29
VRS 1
]
Press the [F1] function key in order to modify the gripper No.
]
Enter the new gripper-No.
]
Confirm the entry by pressing the [Return] key.
[F2] Gripper open/closed
The OPEN/CLOSE gripper functions for the selected gripper No. can be modified.
]
Press the [F3] function key in order to change the gripper function. The gripper
function will change again every time the [F3] function key is pressed.
[F3] Conditional gripper function
A gripper function can be made dependent on a link condition. This gripper function will then
be executed when the condition is set as having been fulfilled.
]
Press the [F5] function key.
]
Press the [F4] function key in order to enter a condition.
The other procedures for programming conditional gripper functions are identical with those
for an PLC output link.
Read the "PLC output links" section in this chapter for further information regarding
this.
Programming "QUICK" gripper functions
The required gripper function can also be programmed without calling up the PLC gripper
menus (QUICK-programming) for teaching, inserting and correcting in the selected TCP.
]
Select the main menu for new teaching, inserting or correcting. The following screen
will be displayed.
Hand Î Teaching Î EDIT
Ei 1 - 6 100 % Z1
SEQUENCE: 5
Pnt: 0
PTP
Vb: 100 %
Ve: 100 %
Aa: 100 %
Ae: 100 %
Jerk: 100 %
Toler.: 200 1/10 deg
PLC
---
F1
Page:9-30
COORDI- Interpolation
NATES
F2
F3
Next
point
Continue
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Press the relevant hand console key in order to enter the OPEN or CLOSE gripper
function. The gripper information menu will be displayed on the screen:
ATTENTION!
Gripper No. 1 open
F1, gripper open or F5 clear
the movement
Quick
Prog
F1
open/cl
F2
F3
F4
F5
The displayed gripper number (Z1 here) can be corrected via the [Gripper+] / [Gripper-]
keys, the displayed gripper function (OPEN here) can also be changed via the [Gripper
CLOSED] key.
Press the [F1] function key to automatically program the gripper function in the last
PLC line of the point program. The output menu will be displayed again on the screen
after this.
]
Gripper and interbus docking function
Furthermore, it is also possible to carry out docking processes. A precondition here is that a
dockable interbus module must have been previously entered in the gripper menu for a
docking gripper and the CFG-list must have been modified accordingly.
Please read the “300 Assigning grippers” and “351 Editing IBM CFG” sections in
Chapter 14 “Modifying constants” regarding this.
]
The following menu is displayed after actuating the relevant gripper so that a
dockable gripper can be docked or undocked in [HAND] mode:
Z01
A TTENTION!
Gripper function
Gripper No. 6 docking gripper at
IBM mod: 8/8 Dock
GRIPPER open or F5 to initiate the movement
Dock
Undock
open/close
F1
F2
F3
F4
F5
]
Pressing the [F2] or [F3] function keys will either dock or undock the selected
gripper.
]
Press [F5] on the hand-held control panel to enter the OPEN or CLOSE gripper
function.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-31
VRS 1
]
There is now a new command in the PLC: “IBM Dock”, which enables the
programming of a dockable module:
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1>
JUMP
MARK
JUMP IBM Dock
F1
]
F2
PLC-Teach
F3
F4
Press the [F3] function key to display the letter “D” in the PLC line:
Sequence: 5
Pnt:
10
TC
JC
S-P
TS
1 > D1 03.00 8/8 Dock
Please enter interbus module-No.
F1
]
F5
F2
F3
PLC-Teach
F4
F5
Either a “0” for undocking or a “1” for docking can be entered afterwards. The
following menu will be displayed:
Pnt:
10
Sequence: 5
TC
JC
S-P
TS
1>D
Undock module = 0 Dock = 1
F1
F2
F3
PLC-Teach
F4
F5
:
A module number is then displayed and the associated module name (if available). Now use
[Cursor] UP or DOWN to select the required module from the list of dockable modules.
Terminate the selection process by pressing [RETURN].
Page:9-32
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F2-F1-F1-F5-F1
PLC - flags
Flag = marker sign
The flags in the PLC correspond to so-called marker signs that can only be imported in the
logical 0 or 1 state (0 = not set, 1 = set)
The advantage of the flags is that once a condition is set it can be saved permanently
(marked): e.g. cycle checks, stack position occupied etc.
When a flag has been set (logical 1), it retains this state until it is deliberately cleared by
reaching the end of the sequence or a new start has been selected.
Exception: static flags.
The maximum number of flags that can be programmed is 944 (F1 - F944). This is identical
for both the point related and the free running PLCs.
!
Important note
System inputs and outputs can be constructed with flags. These flags can be used to
interrogate the system statuses and the relevant evaluation can be made (e.g.
interrogating the operating mode, evaluating the error diagnostics). You must ensure that
these flags are not overwritten.
The assignments are described in the "315 system I/O" section of chapter 14
"Modifying the constants".
07.03.02
Elektroplanung-und Anlagenbau
Page:9-33
VRS 1
Flags
You can set each individual flag to a specific state (0 or 1).
Read the "303 specific setting/deleting/editing of flags" section in chapter 14
"Modifying the constants" for further information regarding this.
Switching PLC flags on and off and linking
Flags can be allocated to both point related as well as free running PLC statuses.
]
The following screen will be displayed after selecting the PLC menus.
Sequence: 5
TC
JC
S-P
TS
1>
OUTPUT
F1
]
Pnt: 10
MARK
WAIT
F2
F3
PLC-TEACHING
GRIPPER Continue
F4
F5
Press the [F5] function key to change the function key assignments.
Sequence: 5
TC
JC
S-P
TS
1>
ARITH.
FLAG
VERIF.
F1
F2
]
Press the [F1] function key.
]
Enter the flag-No.
Page:9-34
Pnt: 10
PLC-TEACHING
MARKER
F3
Continue
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Confirm the entry by pressing the [Return] key. The following screen will be
displayed.
Sequence: 5
TC
JC
S-P
TS
1 > F100
(F1 – F3, ESC)
SW-IN SW-OUT
F1
F2
Pnt:
10
SPC-FLAG
LINK
F3
F4
F5
]
Press the [F1] function key in order to set the flag to the logical ON state or
]
Press the [F2] function key in order to set the flag to the logical OFF state or
]
Press the [F3] function key in order to allocate the results of a logical link to the flag.
The other procedures for the programming of flag links are identical to an PLC output link.
Read the "Inserting other links within a line" section in this chapter for more
information regarding this.
PLC - static flags
As opposed to normal flags, those defined as static flags retain their logical state after the
end of a sequence.
This option is used in order to identify conditions (or conditions generated only once) and
have them available for further use during sequence changes, when stacking with variable
controlling etc.
Read the "302 defining static flags" section in chapter 14 "Modifying the constants"
for more information regarding this.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-35
VRS 1
PLC arithmetical verification
Hand-F1-F2-F1-F1-F5-F2
This PLC function offers the option of arithmetically verifying the contents of counters, timers,
consecutive binary outputs and/or whole numbers.
The results of the verification are identified by the logical state of certain flags
0 = verification condition was not fulfilled,
1 = verification condition was fulfilled.
The following syntax is valid:
Fx = operand 1 operator operand 2
The following are permitted as operands:
• Whole numbers from -9999 up to +9999
• Contents of counters
• Contents of timers
• Contents of binary outputs
The following can be used in the programming of verification operators:
(>)
• Greater
• Smaller
(<)
• Equal
(=)
• Unequal
(!)
Example:
The arithmetical verification flag F1 should be set to a logical ‘1’, when the contents of
counter i4 is greater than 3. Otherwise F1 remains at a value of logical '0‘.
The following PLC line must be programmed in:
F1 = i4 > 3
]
Select the PLC menu.
]
Press the [F5] function key until the [F2] function key is assigned the
ARITH.VERIFY function (arithmetical verification).
Sequence: 5
TC
SP
S-P
TS
1>
ARITH.
FLAG
VERIF.
F1
Page:9-36
F2
Pnt: 10
PLC-TEACHING
MARKER
F3
Continue
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Enter the flag-No. (No. 1 in this example).
]
Confirm the entry by pressing the [Return] key.
You will now be asked to enter the first verification case.
The sequence end verification case can be entered via the function keys.
[F1]
=
i
counter
Shift [F1] =
t
counter
[F2]
=
a
binary output
Shift [F2] =
b
counter
[F4]
=
+NUMBER positive number (maximum 9999)
[F5]
=
-NUMBER negative number (maximum -9999)
]
Press the [F1] function key = i
]
Enter the counter number (e.g. 4).
]
Confirm the entry by pressing the [Return] key.
The condition for entering one of the following verification operators will be displayed:
[F1] = (=)
equal
]
[F2]
=
(!)
unequal
[F3]
=
(<)
smaller
[F4]
=
(>)
greater
Press the [F4] function key = ‘greater’ for the example shown above.
You will now be asked to enter the second verification case.
]
Press the [F3] function key = +NUMBER in order to enter a positive number.
]
Enter the number (e.g. 3).
]
Confirm the entry by pressing the [Return] key.
Sequence: 5
TC
JC
S-P
TS
1 > F1 = i4
i|t
a|b
F1
F2
Pnt: 10
>
PLC-TEACHING
3
F3
+number
-number
F4
F5
The arithmetical verification is now programmed! The output menu will be displayed. The
pointer (>) will now be positioned on the next free PLC-line.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-37
VRS 1
PLC markers
Hand-F1-F2-F1-F1-F5-F3
One or more logical links can be joined in the PLC by using a marker (M). Markers can be
defined either at the start of or during a sequence.
The marker status will be updated in each point.
A marker can be defined for an PLC instruction that has been allocated a logical link, e.g.:
M01 = I11 & I12.
After the definition, a marker can be interrogated at a later point in time. During the
interrogation the marker is seen as a sort of position holder for the previously defined link.
If the following line has been programmed:
O01 = O01
Output O1 will assume the status shown in the defined link of the marker at the given point in
time.
In the above example, the following allocation will actually be evaluated:
O01 = (I11 & I12)
The point related and free running PLCs each have 24 individual markers (M1 - 24)
available for use. As opposed to all other PLC operands, the markers can be defined
differently in both the point related and the free running PLCs, without having any disrupting
effects.
All markers are saved during the power-down routine and are therefore available for use
after the system is switched on again.
Markers can be logically linked via the operators AND (&), OR (+) and NOT (!) in the same
way as for other operands.
Example 1: Using a marker
Output O10 should not be set until the inputs I10 AND I11 OR I10 AND I12 are logically set =
1 (closed).
E1 0
E1 1
E1 2
A 10
A10
This is written as:
O10 = I10 AND I11 OR I10 AND I12
Which becomes: O10 = I10 & (I11 + I12)
Page:9-38
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Using and defining a markers:
M1 = I11 + I12
To be programmed as:
O10 = I10 & M1
Example 2:
I1 0
I2 4
I1 2
I1 4
Re la y
I2 0
O 10
O 10
Written as:
O10 = I10 AND (I12 OR I14
OR NOT I20) OR I24
Which becomes: O10 = [I10 & (I12 + I14 +!I20)] + I24
Marker defined as: M1 = I12 +I14 + !I20
Programming: O10 = I10 & M1 + I24
With mixed links:
AND (&) comes before OR (+)
Switching on and off / linking PLC markers
]
Select the PLC menu in order to program a PLC marker. The following menu will be
displayed:
Sequence: 5
TC
JC
S-P
TS
1>
OUTPUT MACRO
F1
07.03.02
F2
Pnt: 10
WAIT
F3
PLC-TEACHING
GRIPPER Continue
F4
F5
Elektroplanung-und Anlagenbau
Page:9-39
VRS 1
Press the [F5] function key. The function key assignments will be changed.
]
Sequence: 5
TC
JC
S-P
TS
1>
ARITH.
FLAG
VERIF.
F1
F2
Pnt: 10
PLC-TEACHING
MARKER
F3
Continue
F4
F5
]
Press the [F3] function key in order to program a marker.
]
Enter the marker No. (5 in this example).
]
Confirm the entry by pressing the [Return] key. The PLC marker menu will be
displayed.
Sequence: 5
TC
JC
S-P
TS
1 > M5
(F1 - F3, ESC)
SW-IN SW-OUT
F1
F2
Pnt: 10
PLC MARKER
LINK
F3
F4
F5
]
Press the [F1] function key in order to define the marker with the logical status ON
or
]
Press the [F2] function key in order to define the marker with the logical status OFF
or
]
Press the [F3] function key in order to define the marker with a logical link.
The other procedures for linking an PLC marker are identical to an PLC output link.
Read the "Inserting other links within a line“ section in this chapter for more
information regarding this.
Page:9-40
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F2-F1-F1-F5-F5-F1
PLC - counter (arithm.)
In an PLC there are 10 arithmetical counters (i0 ... i9) available for use which can accept a
whole number value between -9999 and +9999.
The content of a counter can be set to a specific start value or it can be reset.
Read the "340 setting the PLC-counter arithmetically" section in chapter 14
"Modifying the constants" for more information regarding this.
If exceeding (> +9999) or under running (< -9999) the values the counter contents will remain
at the maximum value.
The counters are global, i.e. for all sequences, all sub-programs and also valid for the free
running PLCs and will not be automatically reset to "0" at the end of a sequence or during
a sequence change!
In addition, the counters have been set so that they will not loose their current values during
a power-down routine or a power failure.
The following syntax is valid for counters:
iX (condition) = instruction
Condition:
The value allocation of a counter can be made dependent on a condition. The condition can
have the logical status of inputs, markers, flags, outputs, sensors or timers.
Instruction:
An arithmetical print out can be programmed on the right hand side in which can be
comprised of fixed values or counter variables.
The operators plus (+), minus (-), multiply (*), divided by (/) are permitted in an instruction.
!
Note:
• Positive number divided by 0
= +9999
• Negative number divided by 0
= -9999
• 0 divided by 0
= "0".
07.03.02
Elektroplanung-und Anlagenbau
Page:9-41
VRS 1
Example 1:
i3 (I14) = 0
Here counter i3 is set to a "0" value, when input I14 is set to 1. If counter I14 has not been
switched (still at "0"), the contents of counter i3 remain unmodified.
Example 2:
i4 (M4) = i4 + i3 x 4 - 9
Attention! Point comes before line calculation!
Here counter i4 is set to the value depending on marker M4, which is given from the results
on the right hand side, i.e. when marker M4 = 1, the counter variable i4 will be set to the
value that is given by the following calculation:
Old content of i4 + (content of i3 x 4) - 9
PLC-counter programming
The programming of an PLC counter should be practised via examples.
Example 1:
Counter i3 should be set to a value of 4.
The PLC line should be programmed as follows:
i3(
)=4
]
Select the PLC menu.
]
Press the [F5] function key until the [F1] function key is assigned the COUNTER
function.
Sequence: 5
TC
JC
S-P
TS
1>
Pnt: 10
PLC-TEACHING
COUNTER TIMER
BINARY
ANALOG Continue
F1
F2
F3
F4
F5
]
Press the [F1] function key.
]
Enter the counter-No. (3 for the example above).
]
Confirm the entry by pressing the [Return] key. The question, whether the value
allocation should be made conditional follows.
Page:9-42
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Press the [F1] function key in order to make the value allocation of the counter
dependent on the logical status of a condition (inputs, markers, flags, outputs,
sensors or timers)
]
Press the [F2] function key in order to always allocate a value to this PLC instruction
for the counter.
or
In the above case the allocation is not conditional.
]
Press the [F2] function key. The following screen will be displayed:
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > i3 ( ) = 0
Please enter an arith. instruction !
*| /
i|t
a|b
+|-
F1
F2
F3
F4
F5
You will now be asked to enter an arithmetical instruction. In order to set the counter to the
value of 4 in this case, proceed as follows:
]
Enter the number 4.
]
Confirm the entry by pressing the [Return] key.
The counter allocation is now finished.
Example 2:
Counter i4 should be expanded with the product of the counter contents of i3 and the number
4. The number 9 will be generated as the result. Apart from this, the allocation should be
made dependent on marker M4.
The PLC line must be programmed as follows:
i 4 (M4) = i4 + i3 x 4 - 9
Attention! Point comes before the line calculation
]
Select the PLC menu.
]
Press the [F5] function key until the [F1] function key is assigned the COUNTER
function.
Sequence: 5
TC
JC
S-P
TS
1>
COUNTER TIMER
F1
07.03.02
F2
Pnt: 10
PLC-TEACHING
BINARY ANALOG Continue
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:9-43
VRS 1
]
Press the [F1] function key.
]
Enter the counter No. (3 for the example above).
]
Confirm the entry by pressing the [Return] key.
You will now be asked whether the value allocation should be made conditional. In this
example the allocation must be made dependent on marker M4.
]
Press the [F1] function key in order to make the value allocation of the counter
dependent on the logical status of a condition.
The following operands can be entered via the function keys as conditions:
E = input
M = marker
F = flag
A = output
S = sensor
T = timer
]
Press the [F2] function key = M (marker).
]
Enter the number of the marker.
]
Confirm the entry by pressing the [Return] key.
]
You can now negate the condition. Press the [F2] function key in order not to
negate the condition with the marker M4.
The displayed screen will change. The condition can now be entered on the right hand side
of the equals sign. The cursor blinks on '0‘:
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > i4 ( M4 ) = 0
Please enter an arith. instruction !
*| /
i | t
a|b
+|-
F1
F2
F3
F4
F5
The arithmetic instruction can be entered in the form of a:
• Number (+/- 9999) via the decimal keyboard (for the direct setting of counters,
binary or timer outputs to a specific value).
• Link from operands.
• Combined link created from a number and operands.
Page:9-44
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The following operands can be used with the links:
[F3]
=i
(counter)
Shift + [F3] = t
(timer)
[F3]
=a
(analog output)
Shift + [F4] = b
(binary output)
The operands can be linked with the following operators:
[F1]
=
+
(plus)
[F2]
=
*
(multiply)
[Shf] + [F1] =
(minus)
[Shf] + [F2] =
/
(divided by)
Entering example:
i4 (M4) = i4 + i3 x 4 - 9
]
Press the [F3] function key.
]
Enter the number 4.
]
Press the [F1] function key in order to insert the ‘plus’ operator.
]
Press the [F3] function key.
]
Enter the number 3.
]
Press the [F2] function key in order to insert the ‘multiply’ operator.
]
Enter the number 4.
]
Press [Shf] and [F1] key combination simultaneously in order to enter the ‘minus’
operator.
]
Enter the number 9.
]
Confirm the entered link by pressing the [Return] key.
This will save the programmed PLC line and the displayed menu will also change. The [F1F5] assignments are changed accordingly and the pointer (>) will be positioned on the next
free input line.
Sequence: 5
TC
JC
S-P
TS
1 > i4 ( M04 ) =
COUNTER TIMER
F1
07.03.02
F2
Pnt: 10
PLC-TEACHING
i4 + i3 * 0004 - 0009
BINARY
F3
ANALOG Continue
F4
F5
Elektroplanung-und Anlagenbau
Page:9-45
VRS 1
PLC-timer
Hand-F1-F2-F1-F1-F5-F5-F2
Up to 10 timers (t0 - t9) can be programmed in the PLC. These are identical for both the
point related and the free running PLCs.
!
Note:
The PLC timers are identical for both the point related and the free running PLC. You
must ensure that the same timer is not used twice by mistake.
It counts in 1/10 second cycles and can be used for the ranges from -9999 up to +9999 1/10
seconds. This corresponds to a running time of +/- 999.9 seconds = +/- 16.67 minutes.
Regardless of which starting value the timer is set to, it will always count in the positive
direction up to +9999. The timer will only be stopped by either a timer-STOP instruction or by
reaching the end value (+9999).
-9 9 99
0
+ 99 99
The following syntax is valid for the timer:
tX (condition) = instruction
Condition:
The starting or stopping of a counters can be made dependent on a condition. The condition
be the logical state of inputs, markers, flags, outputs, sensors or timers.
Instruction:
An arithmetical print out can be programmed on the right hand side in which you can set the
starting value for the timer. The instructions can include either fixed values or counter
variables. The operators plus (+), minus (-), multiply (*), divided by (/) are permitted in an
instruction.
In addition the timer-STOP instruction can also be programmed, which will stop the timer at
the current value.
Displaying the timer contents:
The current timer contents can be displayed in [Automatic] or [Single Step] operating
modes by switching on the online information screen.
Read the "Online information screen" sections in chapter 10 "Single Step operating
mode“ or chapter 11 "Automatic operating mode“ for more information regarding
this.
Page:9-46
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
PLC-timer in a point related PLC
A timer can be programmed within the PLC functions in each TCP. The timer contents
(counter starting value) can also be entered here.
The timer will be started in the point related PLCs, as soon as the robot has reached the TCP
in which the timer was programmed.
Stopping is made analogous to starting. Therefore the STOP instruction must also be
programmed in the relevant TCP for this timer.
Cycle time monitoring:
In point "0", for example, a timer t0 can be set and started at "0". Timer t0 must be stopped at
the last point in the sequence. The actual content of t0 can be verified with a pre-entered
maximum value and any action can be instigated by the results of the verification.
Spot-welding:
The time requirements for spot welding can be determined and monitored here by using a
timer. The procedure is the same as for the cycle time monitoring.
Timeout:
Here the timeout corresponds to the predetermined limits of a programmed wait condition. If
a "Wait for contact" has been programmed in a TCP (e.g. gripper checks) and this message
remains in place, the maximum wait time can be limited by the use of timer-flags in order to
execute the relevant actions (e.g. repeat gripper search).
PLC-timer in a free running PLC
In the free running PLCs, the timer start/ stop instructions must always be linked to a
condition. In practise the unconditional setting of a timers leads to no results being linked.
Application example in a free running PLC:
Cyclically switching on and off of signal lights:
A timer can be used in free running PLCs, for example, to cyclically switch a signal light
independently of the movement sequence.
The following program cyclically switches output 16 on and off, when marker M1 is set.
1:
2:
3:
t0 (!F01) = -5
F01
= t0 < 5
O016
= M01&T0
07.03.02
(timer t0 starts at -0.5 sec)
(timer restarts if t0 >= 0.5 sec)
(set output, if marker is set to 1 and timer t0 >= 0)
Elektroplanung-und Anlagenbau
Page:9-47
VRS 1
Timer value allocation
The timer can:
• Be set to any required starting value (+/- 9999)
• Set to an allocated value that is given by an arithmetical instruction.
Example:
Timer t1 should be set to the value -600.
The PLC line must be programmed as follows:
t1 (
) = -600
]
Select the PLC menu.
]
Press the [F5] function key until the [F2] function key is assigned the TIMER
function.
Sequence: 5
TC
JC
S-P
TS
1>
COUNTER TIMER
F1
F2
Pnt: 10
BINARY
F3
PLC-TEACHING
ANALOG Continue
F4
F5
]
Press the relevant key for the TIMER function ([F2] (as shown in above example.
]
Enter the timer No. (1 in the example above).
]
Confirm the entry by pressing the [Return] key.
You will now be asked whether the allocation should be made conditional to the timer. In this
case the allocation should be made unconditional.
]
Press the [F2] function key = NO, in order to always execute the timer allocation
from this PLC line.
Page:9-48
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The displayed screen will change. Entering an arithmetical instruction on the right hand side
of the equals sign makes the condition. The cursor blinks on the "0":
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > t1 ( ? ) = 0
Please enter an arith. instruction !
*|/
i|t
a|b
STOP
+|-
F1
F2
F3
F4
F5
The arithmetical instruction can be entered in the form of a:
• Whole number (+/-9999) via the decimal keyboard (for the direct setting of
counters, binary outputs or timers to a specific value)
• Link from operands
• Combination link made up of whole numbers and operands
In order to follow the example above, the number -600 must now be entered.
]
Press [Shf] and [F1] key combination to insert the negative sign for the number 600.
]
Enter the number 600.
]
Confirm the entry by pressing the [Return] key.
This will save the programmed PLC line and the new menu will now be displayed.
The [F1] - [F5] function keys assignments will be changed accordingly and the pointer (>) will
be positioned on the next free input line.
Starting / stopping the timer
The timer is started automatically as soon as the robot reaches the programmed TCP in
which the PLC instruction for the timer has been programmed.
The stop is programmed in the relevant TCP as an PLC instruction.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-49
VRS 1
Example of a timer Stop:
The timer t1 should be stopped in point 12.
The PLC line must be programmed as follows:
t1 (
) = STOP
]
Select the PLC menu in point 10 (for example).
]
Press the [F5] function key until the [F2] function key is assigned the TIMER
function.
Sequence: 5
TC
JC
S-P
TS
1>
COUNTER TIMER
F1
F2
Pnt: 10
PLC-TEACHING
BINARY ANALOG Continue
F3
F4
F5
]
Press the [F2] function key for the TIMER function.
]
Enter the timer No. (1 in the example above).
]
Confirm the entry by pressing the [Return] key.
You will be asked whether the allocation should be made conditional to the timer. In this
example the allocation remains unconditional.
]
Press the [F2] function key = NO in order to always execute the timer allocation
from this PLC line
The displayed screen will change. The condition can be made for entering the timer
allocation. The cursor blinks on the '0‘:
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > t1 ( ? ) = 0
Please enter an arith. instruction !
*|/
i|t
a|b
STOP
+|-
F1
]
F2
F3
F4
F5
Press the [F5] function key in order to program a timer-stop.
Page:9-50
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The ‘Timer-STOP’ PLC instruction is now finished. The [F1] - [F5] function key assignments
will change accordingly and the pointer (>) will be positioned on the next free input line.
PLC timer flag T
Each timer (t) is assigned an identical timer-flag T (t0 → T0, t1 → T1, t2 → T2 etc.) in the
numeration, which can accept the logical state '0‘ or '1‘.
If the contents of the timer (t) are negative (-9999 up to -1),
the flag remains T = 0
If the contents of the timer (t) are zero or positive (0 up to +9999),
the flag will be T = 1.
T= 0
T= 1
-9 9 99
0
+ 99 99
The status change of the timer-flag T from logical '0‘ to '1‘ is made as soon as the negative
content of timers t becomes equal to or greater than '0‘ during an ascending count.
Therefore there exists the opportunity of interrogating the "Timer has expired" event via the
associated timer-flag T.
The timer flag T can only be programmed as an operand.
In conditions:
1 > b5
2
(T5 )
= I1 + I7
In instructions:
1 > O3
2
= T5
+ I1 + I7
Displaying the timer contents:
The current timer contents can be displayed in [Automatic] or [Single Step] operating
modes by switching on the online information screen.
Read the "Online information screen" sections in chapter 10 "Single Step operating
mode“ or chapter 11 "Automatic operating mode“ for more information regarding
this.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-51
VRS 1
PLC-binary outputs
Hand-F1-F2-F1-F1-F5-F5-F3
In the controller the simultaneous outputs of several relays (maximum of 16 relays
simultaneously!) can be indicated as binary outputs.
These relays are assigned significances (2n) (1, 2, 4, 8, 16, 32, 64, 128, 256 etc.) in
accordance with the binary code, so that with 16 relays a decimal number having a value of
up to 216 -1 = 65.535 can be generated.
Afterwards the binary coded decimal number can be decoded and further processed,
according to the relays that have been set, in a superior level operating material controller.
The following syntax is valid for binary outputs:
bX (condition) = instruction
Condition:
The instruction output can be made dependent on a condition. The condition can be the
logical state of inputs, markers, flags, outputs, sensors or timers.
Instruction:
An arithmetical print out can be programmed on the right hand side, which can be outputted
via the relevant relays. The instructions can include either fixed values or counter variables.
The operators plus (+), minus (-), multiply (*), divided by (/) are permitted in an instruction.
Application:
Item count display
current or total number
Cycle time display
current or total time
Outputting code numbers for welding programs
Relay assignments:
There are 16 relay outputs located on the I/O board, from which a maximum of 16
consecutive outputs (+1 parity - output) can be freely selected for the binary outputs. The
control of the respective relays is carried out via the controller after the decimal number has
been converted in to the relevant binary code.
Number of outputs:
Up to 16 binary outputs (b0 - b15) in various formats can be set (defined), these are valid
for both the point related as well as the free running PLCs.
Read the "304 entering binary output formats" section in chapter 14 "Modifying the
constants" for further information regarding this.
Page:9-52
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
This can be set here, under the relevant number (b0 - b15):
• The number of consecutive relay outputs (width)
• The start position from which this should be made.
The start relay is assigned a significance of 1, the sequential relays in this group have the
corresponding significances of 2, 4, 8, 16 etc.
The allocation of a control relay (parity), which is the next following relay this relay group is
and is added to the number of the outputs that have been set to 'even‘ or 'odd‘ parity.
Read the "304 entering binary output formats" section in chapter 14 "Modifying
the constants" for further information regarding this.
Starting the output:
The start of the binary output can be made as conditional or unconditional by entering the
defined output No. b0 - b15.
Revoking the output (clearing):
The clearing of the binary output can be made as conditional or unconditional by entering the
defined output No. b0 - b15 with the output value 0.
Examples for binary outputs
In accordance with the programmed width and the values to be outputted, all relays for this
binary output remain set or cleared until the output value '0‘ is outputted or this binary output
is overwritten by a subsequent output.
If an overlapping of two binary outputs occurs due to the wrong programming of the start
of the output then only the relays in the overlapping area will be overwritten! The remaining
relays will retain their previous switching statuses.
The parity checking can be used for the transfer control of the output values to a superior
level controller.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-53
VRS 1
The controller determines the number of set relays from the output values. If the number is
uneven and the binary output parity = EVEN has been pre-entered, the controller will
additionally set the parity relay to 'ON‘, to give an EVEN number of relays.
1. Bina ry o u tp u t sig n ific a nc e 10 W id th 4 Sta rt: 1
Pa rity: EV EN
10 = Sig nific a nc e 8 + 2 = O 2 + O 4
O 1 O 2 O 3 O 4 O 5 O 6 O 7 O 8 O 9 O 10 O 11 O 12 O 13 O 14 O 15 O 16 O 17 O 18 O 19 O 20 O 21 O 22 O 23 O 24
1
2
4
Sig n ific a n c e
8
.Pa rity
2. Bina ry o u tp u t sig n ific a nc e 10 W id th 4 Sta rt: 9
Pa rity: O D D
10 = Sig nific a nc e 8 + 2 = O 10 + O 1 2 + O 13
O 1 O 2 O 3 O 4 O 5 O 6 O 7 O 8 O 9 O 10 O 11 O 12 O 13 O 14 O 15 O 16 O 17 O 18 O 19 O 20 O 21 O 22 O 23 O 24
1
2
4
Sig n ific a n c e
8
Pa rity
3. Bina ry o u tp u t sig n ific a nc e 10 W id th 4 Sta rt: 1
Pa rity: EV EN
(b 0 )
10 = Sig nific a nc e 8 + 2 = O 2 + O 4
Bina ry o u tp u t sig n ific a nc e 10 W id th 4 Sta rt: 9
Pa rity: O D D
(b 1 )
10 = Sig nific a nc e 8 + 4 + 1 = O 9 + O 1 1 + O 12
Bina ry o u tp u t sig n ific a nc e 10 W id th 8 Sta rt: 1 5
Pa rity: N O N E
(b 2 )
10 = Sig nific a nc e 1 + 2 + 16 + 32 + 64
b0
= O 15 + O 16 + O 19 + O 20 + O 2 1
b1
b2
O 1 O 2 O 3 O 4 O 5 O 6 O 7 O 8 O 9 O 10 O 11 O 12 O 13 O 14 O 15 O 16 O 17 O 18 O 19 O 20 O 21 O 22 O 23 O 24
1
2
4
Sig n ific a n c e
8
Pa rity
1
2
4
Sig n ific a n c e
8
1
Pa rity
2
4
8 16
32
Sig n ific a n c e
6 4 1 28
PLC binary output allocation
With this function you can select the output value for a binary output to be allocated via an
arithmetical link with a timer, counter or a binary output.
In addition, this instruction can be made dependent on the logical state of an input, marker,
flag, output, sensor or timer.
Example 1:
The binary output b4 should be expanded with the product from the counter contents i3 and
the number 4. The number 9 will be generated from the result. Apart from this the allocation
should be made dependent on marker M4.
The PLC line must be programmed as follows for this:
b4 (M4) = b4 + i3 x 4 - 9
Attention! Point comes before the line calculation!
Page:9-54
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Select the PLC menu.
]
Press the [F5] function key until the [F3] function key is assigned the BINARY
function.
Sequence: 5
TC
JC
S-P
TS
1>
COUNTER TIMER
F1
F2
Pnt: 10
PLC-TEACHING
BINARY ANALOG Continue
F3
F4
F5
]
Press the [F3] function key.
]
Enter the binary output No. (4 in the above example).
]
Confirm the entry by pressing the [Return] key.
You will now be asked whether the value allocation should be conditional. In this example the
allocation should be made dependent on marker M4.
]
Press the [F1] function key in order to make the value allocation of the binary output
dependent on the logical state of a condition.
The following operands can be entered as conditions via the function keys:
E
=
input
M
=
marker
F
=
flag
A
=
output
S
=
sensor
T
=
timer
]
Press the [F2] function key = M (marker)
]
Enter the marker number.
]
Confirm the entry by pressing the [Return] key.
]
You can now negate the condition.
]
Press the [F2] function key = NO, as the condition must not be negated with marker
M4.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-55
VRS 1
The display on the screen will change. The condition, which must be entered as an
arithmetical instruction on the right hand side of the equals sign, will be displayed.
The cursor blinks on the "0":
Pnt: 10
PLC-TEACHING
Sequence: 5
TC
JC
S-P
TS
= 0
1 > b4 ( M04 )
Please enter an arith. instruction !
*|/
i|t
a|b
+|-
F1
F2
F3
F4
F5
The arithmetical instruction can be entered in the form of a:
• Number (+/-9999) via the decimal keyboard (for the direct setting of counters,
binary or timer outputs to a specific value)
• Link from the operands
• Combination link created from a number and operands
The following operands can be used for the links:
[F3]
Shift + [F3]
[F4]
Shift + [F4]
= i (counter)
= t (timer)
= a (analog output)
= b (binary output)
The operands can be linked with the following operators:
[F1]
= + (plus)
[F2]
= * (multiply)
[Shf] + [F1] = - (minus)
[Shf] + [F2] = / (divided by)
]
Press the Shift - [F4] = b.
]
Enter the number 4.
]
Press the [F1] function key in order to insert the ‘plus’ operator.
]
Press the [F3] function key = i.
]
Enter the number 3.
]
Press the [F2] function key in order to insert the ‘multiply’ operator.
]
Enter number 4.
]
Press [Shf] and [F1] key combination simultaneously in order to insert the ‘minus’
operator.
]
Enter the number 9.
Page:9-56
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Confirm the entered link by pressing the [Return] key.
This programmed PLC line is then saved and the new menu is displayed on the screen. The
[F1] - [F5] function key assignments are changed accordingly and the pointer (>) is
positioned on the next free input line.
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 b4 ( M04 ) = b4 + i3 * 0004 - 0009;
2>
COUNTER TIMER BINARY ANALOG Continue
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:9-57
VRS 1
Analog output
Hand-F1-F2-F1-F1-F5-F5-F4
Basis
Up to eight virtual analog channels (a1 - a16) can be defined in the PLC.
In the PLC an analog channel is another arithmetical case analogous to the already existing
counters (i0 - i15), timers (t0 - t9) and binary outputs (b0 - b15).
An analog channel is given a value allocation (value range ±9999) via an arithmetical
instruction. An analog channel can also be an operand in an arithmetical instruction.
The assignments between the virtual analog channel No. and the physical output number
can be set in the constant range of the VRS1. The values for the analog channels are given
as analog voltages in mV.
Three types of analog outputs exist, each of these has differently structured value
allocations:
1.
Constant voltage
The value allocation is a normal arithmetical allocation having a maximum of eight operands
analogous to the value allocation of a binary output.
2.
Constant voltage with weaving offset
The value allocation has two sections. In the first section the constant (basic) voltage is preentered as an arithmetical allocation having a maximum of four operands. In the second
section the amplitude of the robots synchronised oscillating offset voltage for the weaving
movement is superimposed on the basic voltage. The arithmetical allocation is also preentered with a maximum of four operands here.
3.
Velocity proportional voltage with offset
The value allocation has two sections. In the first section the normal velocity, i.e. the velocity
that can be attained at a maximum voltage of 10V is pre-entered via an arithmetical
allocation having a maximum of four operands. In the second section a constant (offset)
voltage is pre-entered via an arithmetical allocation having a maximum of four operands.
The analog output will be activated upon entering the accuracy ball in which the relevant
instruction has been programmed in the PLC instructions. The analog output remains active
until the voltage is reset to zero again via a relevant PLC instruction (e.g. a1 = 0 mV) or by
the sequence end, depending on which occurs first.
The stopping of the analog outputs during drive system OFF, SSR etc., corresponds to the
stopping of the digital outputs that have the output attribute: stop when drive system OFF =
0. This can also be entered as an attribute for analog outputs.
Read the "321 Attributes for analog outputs" section in chapter 14 "Modifying the
constants" for further information regarding this.
During Single-Step reversing the voltage value will remain set at zero until another SingleStep forwards traverse signal arrives.
In the free running PLC you are only permitted to use analog outputs with a constant voltage
as given in point 1 above.
Page:9-58
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Programming the analog output
The programming of an analog output is initially carried out in the same way as the
programming of a binary output. After entering the channel number and a possible execution
condition, the interrogation of the type of output is made (see example 1).
Depending on the type of analog output, one or two inputs from arithmetical allocations (see
examples 2 and 3) will be made. Up to 60 characters can be entered, though only 12
characters will be displayed. When an insert mark at the edge of the display area is reached
(by entering, backwards deleting or with the arrow keys), the text will be automatically
scrolled, so that the input text can also be edited and displayed via the 12 characters. The
entry can be either discarded by using the "Esc" key or confirmed with the "Return" key. After
conformation a syntax check of the entry analogous to the checking of the binary output
instructions will be carried out. Furthermore the number of operands will be checked. The
allocation of a constant analog output (type 1) is only permitted to contain up to eight
operands. Both allocation sections for a weaving shape or a velocity proportional analog
output (type 2 or 3) are only permitted to have up to four operands.
]
Select the PLC menu.
]
Press the [F5] function key until the [F4] function key is assigned the ANALOG
function.
Sequence: 5
TC
JC
S-P
TS
1>
Pnt: 10
PLC-TEACHING
COUNTER TIMER
BINARY
ANALOG Continue
F1
F2
F3
F4
F5
]
Press the [F4] function key.
]
Enter the analog output No.
]
Confirm the entry by pressing the [Return] key. The interrogation to see whether the
value allocation is conditional will now be carried out.
]
Press the [F2] function key in order to allocate a permanent fixed value to the
analog output via this PLC instruction. The following screen is displayed:
Example 1: Selection menu for the type of analog output:
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > a1 ( ? )
Please enter the type of analog output
Const
Weave
V-prop.
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:9-59
VRS 1
Example 2: analog output instruction type "Const" [F1]:
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > a1 ( ? ) Const: 0
mV
Please enter constant voltage [mV]
+|*|/
i|t
a|b
F1
F2
F3
F4
F5
Example: 3a: First part of an analog output instruction type "Const. with weave" [F3]:
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > a1 ( ? ) Cst+P: 0
mV
Please enter constant basis voltage [mV]
+|*|/
i|t
a|b
F1
F2
F3
F4
F5
Example: 3b: second part of an analog output instruction type "Const. with weave":
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > a1 ( ? ) Weave:0
Please enter weaving voltage [mV]
*|/
i|t
a|b
+|-
F1
F2
F3
F4
F5
Example: 4a: first part of an analog output instruction type "V-prop" [F5]:
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > a1 ( ? ) Vprop:0
mV
Please enter normal velocity [mm/s] / [10V]
+|*|/
i|t
a|b
F1
Page:9-60
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Example 4b: second part of an analog output instruction type "V-prop":
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS
1 > a1 ( ? ) Offset:0
mV
Pleas enter constant offset [mV]
+|*|/
i|t
a|b
F1
F2
F3
F4
F5
Compatibility
The analog outputs in the PLC that were programmed using an older version will be
automatically converted when being started from version 1.12 onwards. The previous
functions are therefore retained.
Example:
]
Old: in point 10 the analog output is programmed with a constant voltage of 1000
mV.
Hand->Teaching>Edit
SEQUENCE:
5
Pnt:10
1
Analog output set
Channel
:
1
Output type
:
1
Const
Value/norm. factor: 1000
mV
Offset
:
0
mV
Set+
Set-
F1
]
F3
F4
F5
New: after automatic conversion:
Sequence: 5
TC
JC
S-P
TS
1> a1 ( ? )
Const
F1
F2
Pnt:
=
9
PLC-TEACHING
Const: 1000 [mV]
Weave
F2
F3
V-pop.
F4
F5
Sequence: 5
TC
JC
S-P
TS
1> a1 ( ? )
Const
F1
Pnt:
=
10
PLC-TEACHING
Const: 1000 [mV]
Weave
F2
F3
V-pop.
F4
F5
Analog outputs programmed in an earlier version with zero points are ignored during the
conversion.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-61
VRS 1
Hand-F1-F2-F1-F1-F5-F5-F5
PLC jump command
Loops and branches can be programmed in the PLC using jump marks (labels) and jump
commands (GoTo´s).
Application areas:
• PLC point commands
• PLC macro commands
• Free running PLC
The use of jump marks and jump commands is localised and must be conclusive within the
current areas. If a jump command has been programmed then the associated jump mark can
only be used once within the same area. Jumps to the outside are not possible. In the free
running PLC only forward jumps are permitted. The testing of the jump command is made in
conjunction with the trajectory testing.
The jump marks are comprised of a fixed text part (LABEL) and a number between 0 and 9.
The jump command is comprised of an L followed by a number between 0 and 9, as well as
a Boolean instruction that will execute the jump condition.
A jump will only be executed when the jump condition is fulfilled (evaluation of the Boolean
instruction). It will jump to the LABEL with the number that concurs with the number of the
jump commands.
Programming a jump command:
Sequence: 5
TC
JC
S-P
TS
1>
JUMP
MARK
JUMP
F1
F2
Pnt: 10
PLC-TEACHING
Continue
F3
F4
F5
[F1] Jump mark
] Press the [F1] function key in order to program a jump mark.
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > LABEL
Please enter label number
F1
Page:9-62
F2
F3
PLC-LABEL
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Enter the label No.
]
Confirm the entry by pressing the [Return] key.
The LABEL <x> command (menu option: JUMP MARK) corresponds to the positioning of the
jump mark (label) No. x.
[F2] jump
] Press the [F2] function key in order to program a jump.
Sequence: 5
Pnt: 10
PLC-JUMP
TC
JC
S-P
TS
1>L
Please enter a number (max = 9)
F1
F2
F3
F4
F5
Switching on a jump command:
] Enter the jump command No.
]
Confirm the entry by pressing the [Return] key.
]
Press the [F1] function key in order switch ON the PLC programming line with the
jump command L1. The PLC line is then shut down by this action and the PLC
teaching menu will be displayed on the screen.
]
Afterwards the pointer will be positioned on the next free input line (2), in which you
can enter further PLC instructions by using the [F1] - [F5] function keys.
Switching off a jump command:
The procedure for switching off jump commands is identical to the switching on
programming.
]
Press the [F2] function key in order to program a jump command.
]
Enter a jump command No.
]
Close the entry by pressing the [Return] key. The PLC jump command menu will
now be displayed.
]
Press the [F2] function key in order to switch OFF the PLC programming line with
the jump command Lx.
The Lx = ... command (menu option: JUMP) is the "jump after label x command". A jump
condition should be entered to the right of the equals sign. The programming of a jump
condition is analogous to the programming of an instruction for an output.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-63
VRS 1
In order to link jump commands, proceed as follows:
]
Press the [F1] function key in order to program a jump command.
]
Enter a jump command No. (e.g. 2).
]
Confirm the entry by pressing the [Return] key. The PLC jump menu will now be
displayed.
Sequence: 5
TC
JC
S-P
TS
1 > L2
(F1 – F3, ESC)
SW-IN
SW-OUT
F1
]
F2
Pnt: 10
PLC-TEACHING
LINK
F3
F4
F5
Press the [F3] function key in order to link the jump command with other operands.
The following report will be displayed.
Pnt: 10
PLC-JUMP
Sequence: 5
TC
JC
S-P
TS
1 > L2
?;
Please enter an operand (F1 – F5) >
I
M
F
O
Continue
F1
F2
F3
F4
F5
]
Enter the relevant operand (input, marker, flag, output) in the links menu via the [F1]
- [F4] function keys.
]
Press the [F5] function key in order to select other operands (sensor and timer
flags).
If, for example, you wish to enter input I13 as an operand, proceed in the following manner:
]
Press the [F1] function key (I = input).
]
Enter the input No. (13 for above example).
]
Confirm the entry by pressing the [Return] key.
Page:9-64
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The selection options for whether the input (operand) should be negated (negated = NOT
ON) will be displayed on the screen.
Sequence: 5
Pnt: 10
TC
JC
S-P
TS
1 > L2
?;
Negate the operand (!) ? I13
YES
NO
F1
F2
F3
PLC-JUMP
F4
F5
]
Press the [F1] function key in order to negate the operand or
]
Press the [F2] function key in order not to negate the operand.
In this example the [F2] function key must be pressed. This links the jump command L2 is to
input I13.
Now you have the option of inserting other links.
Pnt: 10
Sequence: 5
TC
JC
S-P
TS
1 > L2
I13;
(F1 – F3, ESC)
Delete
Insert
Edit
F1
F2
F3
PLC-JUMP
F4
F5
Read the "Inserting other links within a line" section in this chapter for more
information regarding this.
]
If no more links are to be inserted, press the [Return] key.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-65
VRS 1
PLC traversing conditions (TC)
Hand-F1-F2-F1-F1
The programming of traversing conditions ensures that the robot can only traverse to or
traverse from a programmed TCP when the relevant conditions have been fulfilled.
If no traversing conditions have been programmed in the TCP it will continue traversing.
A traversing condition is valid for either online (on the trajectory between two TCP's) or only
in the point (in the accuracy ball of a TCP).
!
A traversing condition is always permanently linked to a TCP or a trajectory and can
only be programmed in point related PLCs.
Validity of the traversing condition:
Online
The traversing condition will be permanently checked on the path to a TCP in which an
online traversing condition. The robot will only traverse when the condition has been fulfilled.
As soon as the online traversing condition is no longer fulfilled, the robot will remain in the
same position on the path (online between two points).
Applications: e.g. machinery safety, robot locking and adhesive dispensing etc.
In the point
Here the traversing condition only refers to the TCP being traversed to. The robot will
continue traversing only when the condition has been fulfilled. If the condition has already
been fulfilled it will traverse through this point as there is no longer a breaking instruction in
this point!
Applications: e.g. feeder devices. Because of the traversing condition in the point it will wait
until the work piece feeder has been correctly positioned. If the part is already in position, the
robot will traverse to this point without stopping.
Traversing conditions can be made dependent on the logical state of inputs, outputs,
markers, flags, sensor flags and/or other logical links.
Page:9-66
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Example: TC: I10 & !M4
Sequence: 5
TC > IN POINT =
JC
S-P
TS
1
F1
F2
Pnt: 10
PLC-TEACHING
I10 & !M04
TRAV.
COND.
ON-LINE
DEL.
COND.
F3
F4
F5
Here the traversing conditions will only be fulfilled when the input I10 is set and the marker
M4 is not set. The programming of the traversing conditions is identical with the linking of an
PLC output.
Read the "Linking PLC-outputs" section in this chapter for more information
regarding this.
Programming
A pre-condition for the programming of a traversing condition is that the co-ordinates for the
TCP have already been taught.
In this example a traversing condition must be programmed in point No. 10 of sequence No.
5.
]
Press the [F1] function key. The PLC teaching menu will be displayed:
Sequence: 5
TC
JC
S-P
TS
1>
OUTPUT MACRO
F1
]
F2
Pnt: 10
WAIT
F3
PLC-TEACHING
GRIPPER Continue
F4
F5
Use the [Cursor Up] key to go to the TC line. The following screen will be
displayed:
Sequence: 5
TC>
JC
S-P
TS
1
Pnt: 10
PLC-TEACHING
TRAV.
CONDITION
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:9-67
VRS 1
]
Press the [F3] function key in order to program the traversing condition. The
displayed screen will change to the following:
Sequence: 5
Pnt: 10
TC >
?;
JC
S-P
TS
1
Please enter an operand (F1 – F5) >
I
M
F
O
F1
F2
F3
WAIT
F4
Continue
F5
]
Enter the relevant operand (input, marker, flag, output) in the links menu via the [F1]
- [F4] function keys.
]
In order to select other operands (sensor and timer flags), press the [F5] function
key.
]
After entering the link, press the [Return] key.
]
The programming is now completed and the following menu is displayed:
Sequence: 5
TC > IN POINT
JC
S-P
TS
1
F1
F2
Pnt: 10
PLC-TEACHING
= I10 & !M04
TRAV.
COND.
ON-LINE
DEL.
COND.
F3
F4
F5
You now have the option of either programming the traversing condition as an ON–LINE TC
or deleting the traversing condition.
Page:9-68
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F2-F1-F1
PLC jump conditions (JC)
You can use a jump condition to jump to a specific programmed TCP within the sequence. A
jump condition should be programmed in the relevant return point with the destination point
(jump destination).
!
Therefore the jump condition can only be programmed in a point related PLC.
A jump command can be executed in three different ways:
Unconditional jump
Regardless of external influences, the jump will always be executed to a programmed
destination point.
Conditional jump
A jump will only be executed, when the programmed condition has been fulfilled.
Calculated jump
You have the option to reach a relevant jump destination, without having to directly enter the
destination point No. The jump destination (destination point No.) here will be determined by
a counter (i0 - i9) whose contents have been generated, for example, from a number of
specific events.
If a condition that is linked to the counter has been fulfilled, the current contents of the
counter correspond to the absolute destination point No. being traversed to.
Example: calculated jump
At the moment the counter for the condition to be filled in point 2 is set at 5; consequently the
robot will traverse from the temporary position onto point 5 (jump destination). With this
option for instructing the program via the PLC, many application conditions can be realised in
a much more elegant way.
Jum p d e stina tio n
7
6
5
4
Sta rt p o int 0
3
1
2
W he n jum p c o nd itio n is fulfille d
the c o unte r = 5
07.03.02
Elektroplanung-und Anlagenbau
Page:9-69
VRS 1
Jump types
Forwards
Within an operating sequence, it is possible under certain conditions not to traverse to certain
programmed TCP's, but to by pass them. This can be, for example, if the point of a suboperation does not have to be processed for each work piece.
Reverse
It is also possible to jump back to TCP's that have already been processed within a
sequence in order to be able to re-traverse the operating sequence from this location again.
!
If a reverse jump has been programmed, you must ensure that the outputs or
conditions set via the PLC instruction are also valid for the point that has been entered
as the jump destination! Otherwise the outputs and conditions must be corrected via
the relevant PLC instructions!
Executing a jump
The programmed jump conditions are continually monitored by the controller and so can
jump when:
Online already on the path to a point or
Point related i.e. executed after reaching a programmed TCP.
Start point 0
Jump condition fulfilled
Point related
Start point 0
Jump condition fulfilled
Page:9-70
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F1-F2-F1-F1
Sub-programs (S-P)
Sub-program calls
A S-P call is programmed in the call point of the PLC. An "absolute" / "relative 1" / "relative 2"
/ "special" identification must be entered in addition to the S-P No. The programmed process
will react accordingly to this identifier.
The "special" identifier only has significance in conjunction with a special S-P module. If a
module has not been loaded the "special" identifier will be handled in the same way as
relative 1.
What are relative S-Ps?
A relative S-P is a completely normal S-P in which the number of the S-P as well as the
"relative" type identification must be pre-entered in the call point. "Relative" means that the SP of a TCP will not traverse as previously to its "taught" positions, but the TCP lies at a new
position dependent on the call point (relative to the call point).
07.03.02
Elektroplanung-und Anlagenbau
Page:9-71
VRS 1
Relative 1
A "relative 1" (abbreviation: rel1) type S-P call invokes a shifting and turning of the entire S-P
from its original "taught" position to a new position of the same type that is dependent on the
current call point so that the position and the tool orientation of the S-P start point is covered
by the position and the orientation of the call point. The construction of the S-P is not
changed by this operation.
UP, Original
UP, aktuell
T2'
Z
Z
TRel
Y
Y
TA
T1'
Aufrufpunkt
X
BASE
X
T0'
T0 = Anfangsposition des originalen UPs
T0
= Original S-P start position
TA = Position des UP-Aufrufpunktes
TA
= S-P call point position
TRel = T . T0-1 = Transformation des UPs
A
TRel = TA · T0-1 = S-P transformation
T 'n = Tn
. TRel =
Neue Position des UP-Punktes n Tn'
Page:9-72
= Tn · TRel
Elektroplanung-und Anlagenbau
= New position of the S-P point n
07.03.02
VRS 1
Relative 2
A "relative 2" (abbreviation: rel2) type S-P call invokes a shifting and turning of the entire S-P
from its original "taught" position to a new position of the same type that is dependent on the
current call point (Pn) and the preceding point (Pn-1) so that the position of the call point can
be used to cover the position of the S-P start point and then the tool X-axis of the S-P start
point continues to point in the traversing direction from Pn-1 to Pn. The Z-axis lays queer to
the X-axis and in between the X-axis and the Z-axis of the level defined by the call point. The
construction of the S-P is not changed by this operation.
S-P, original
UP, Original
S-P, current
UP, aktuell
T2'
TRel
Z
Z''
Pn-1
Y
T''
A
X
BASE
Pn
Z=Z
'
Y'=Y
''
Y
α
T0 '
X''
X
T1'
X'
Aufrufpunkt (X,Y,Z)
Call point (X,Y,Z)
T0 = Anfangsposition des originalen UPs
T''A = Position des korrigierten UP-Aufrufpunktes (X'',Y'',Z''; wo X'' || Pn - Pn-1)
TRel = T''
A
.
T 'n = Tn
. TRel =
-1
T0 = Transformation des UPs
Neue Position des UP-Punktes n
T0
= Original S-P start position
TA
= Corrected S-P call point position (X'',Y'',Z''; where X'' II Pn – Pn-1)
-1
TRel = T''A · T0 = S-P transformation
Tn
'
= Tn · TRel
07.03.02
= New position of the S-P point n
Elektroplanung-und Anlagenbau
Page:9-73
VRS 1
Special
The special S-P enables square, slotted, circular, teardrop and keyhole traversing in any
orientation at any position within the working area of the robot.
This function is set up, for example, in order to be able to cut continually recurring contours
of different sizes at any position in the bodywork during laser welding, without you having to
make new point for point teachings.
An S-P number must be entered for a call just the same as for the other S-P call types. This
number must concur with the 19 points of the originally taught S-P. With an S-P call the
contour offset must be selected in the form of parameters. If the special S-P call has been
selected you can enter the parameters for the sub-program by pressing [F4].
The S-P will not be traversed as it was taught but will be "converted" in the controller to the
respective contour. This means that all the S-P's taught points will be shifted by the controller
and the taught velocities, accelerations etc., will also be shifted by the controller if necessary.
It is possible that the controller will delete certain points from the S-P. In this way the
controller will automatically construct in the required size square, slotted, circular, teardrop or
keyhole traversing programs with the matching velocities, accelerations etc., to be called up
from the S-P. The only original things that remain from the called up S-P are the PLC
instructions.
Calling up sub-programs
If you must branch from a TCP into a sub-program this must be programmed into the PLC of
the relevant TCP.
Sequence: 5
TC
JC
S-P
TS
1>
OUTPUT MACRO
F1
]
F2
Pnt: 10
WAIT
F3
PLC-TEACHING
GRIPPER Continue
F4
F5
Use the [Cursor] keys to position the cursor on the S-P connection input field.
Sequence: 5
TC
JC
S-P >
TS
1
Pnt: 10
PLC-TEACHING
EDIT
F1
Page:9-74
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Press the [F3] function key in order to program a S-P connection.
Sequence: 5
Pnt: 0
TC
JC
S-P>1 ( ? ) abs
TS
1
]
S-P call
No.
i-No.
Cond.
Type
F1
F2
F3
F4
F5
S-P No.1, no call conditions and the "absolute" type are pre-loaded as the default
settings for a new call. These attributes can be edited by the operator via the [F1] [F4] function keys.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-75
VRS 1
Hand-F1-F2-F1-F1
Trajectory switching functions (TS)
Basics
Trajectory switching functions are PLC functions, which are executed whilst the robot is
moving from one point (n-1) to the next point (n) when following a programmed path and/or
during set up or delay times. Therefore this can influence such functions as
• Outputs,
• Flags,
• Binary outputs or
• Analog outputs.
A trajectory switching function (e.g.: "O1 = ON") in a programmed path (e.g.: lTS1), also
covers a TCP (e.g.: P1). A possible setting up time (e.g.: -tD1) can be calculated by
multiplying the current trajectory velocity in mm. Overall this will result in an early execution
of the programmed trajectory switching function.
A typical application example is the spreading of adhesive. Should, for example, the
adhesive spreading be started 100 mm before reaching point 1, the programming of the
setting up time will compensate for the delay caused by the adhesive dispenser.
On the other hand a possible switching delay (e.g.: tD2) will not be recalculated in mm but
will effect a time delayed switching after the programmed path (e.g.: lTS2) has been reached
by the TCP.
Basically programmed trajectory switching functions can be executed both before as well as
after reaching a point. This depends on the path sign and from the entered delay time. A
negative path without a long delay time will result in being switched before reaching the point
(pre-function). A positive path without a long setting up time will result in the switching
occurring after leaving the point (post-function).
Basically a TCP pre-function will be executed at the earliest when reaching the TCP in front.
On the other hand a post-function will be executed at the latest when reaching the following
TCP.
Example:
O01 = ON
O01 = OFF
TCP traject.
Trajectory switching functions are administered and executed by PLCTASK. Here the path
programmed by the operator will be path continually verified against the path that has just
been traversed or the path to be traversed as well. When the paths and/or the delay times
have been reached, the programmed trajectory switching functions will take effect and will be
executed by the PLCTASK.
Page:9-76
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
A pre-condition for this is that the continuos reporting of the TRAJECTORY MODULE via
AUTOMATIC to the PLCTASK. This report consists of individual reports from the TCP
trajectory path that has been traversed in mm, the TCP trajectory path yet to be traversed in
mm and the current trajectory velocity (V-tcp) in mm / s.
If this is a loop the old trajectory path will be reported in addition to the trajectory path that
has been traversed as well as trajectory path that has yet to be traversed. The reported path
values are continuous and are always obtained from the programmed point.
Boundary conditions and limitations
The following conditions are valid for the processing of the TS function instructions via the
PLC:
The setting up time is limited to -300 ms, the delay time can amount to +9999 ms.
When lTS1 lies in the area behind P2 or the path that has just been traversed during time
tD1 in addition to lTS2 lying in the area behind P2, P2 will be switched in the TCP.
When lTS1, the path that has been traversed during time tD2 in addition to lTS2 or the path
that has been traversed during time tD1 in addition to lTS1, lies in the area in front of P1, P1
will be switched in the TCP.
If loops have been programmed in a TCP, the centre point of the path between the entrance
into and the exit out off the accuracy ball will be the reference point for the trajectory
switching functions which will be executed within the accuracy ball. Programmed trajectory
switching functions, that are active outside the accuracy ball use the programmed point as
their reference point.
Reference
07.03.02
Elektroplanung-und Anlagenbau
Page:9-77
VRS 1
With PTP traversing millimetre precise switching is not possible. A path that has been
programmed in mm will be internally converted to a % of the entire point to point movement.
A good example is where a switching position has been programmed at 100 mm and the
direct line distance between both points is 1000 mm, then 100 mm corresponds to 10% of
the absolute point distance of the PTP movement. As the tool tip (TCP) does not always
move along the direct connecting line between both points, therefore even though the path
that has been traversed amounts to 10% of the movement in this case it will not normally be
exactly 100 mm.
TCP movement
For trajectory switching function relevant path
With the "Swivelling" interpolation method, the programming of trajectory switching functions
is only sensible when the affected TCP's do not physically lie next to each other together
(see next point for an explanation).
If trajectory switching functions are programmed between two identical points A and B, i.e.
the velocity and also the path of the TCP that has been traversed are zero, the programmed
trajectory switching functions will be executed at point A with 0 mm path and 0 ms delay. All
of the trajectory switching functions that deviate from these parameters will be executed at
point B.
During a programmed trajectory jump to another TCP, the TS functions from the old points
will no longer be executed. Only the possible TS functions of the jump destination will remain
valid after the jump operation has been executed.
Online velocity modifications do not affect the function of the programmed trajectory
switching functions.
If the drive system is switched off when going along a trajectory with programmed trajectory
switching functions or an operating mode change is carried out, after being switched back on
the drive system will correctly execute the remaining programmed trajectory switching
functions just as if an interruption had not occurred in the first place. If a delayed TS function
was executed prior to the interruption and the delay time had not expired, the remaining time
will be considered as expired after the restart and die function will be executed immediately.
O01 = ON
O01 = OFF
TCP movement
Drive system OFF
Page:9-78
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Programmed trajectory switching functions will be ignored during Single Step reversing.
If another point has become the traversing destination rather than the last current one after
an operating mode change or restart has been made in Automatic or Single-Step forwards
then no functions will be executed until the point has been reached. Only when it is in the
point will all the remaining trajectory switching functions together with all "normal" PLC
functions of the points lying in front be "fetched“. The same is also valid when the robot is
traversed in hand mode, if the tool tip (TCP) has been moved a long way from its original
trajectory after a restart. The basis for a "fetching" of PLC and TS functions in the point is a
dry run through all remaining programmed points.
Current destination point
Aktueller Zielpkt
TCP movement
1) Single-Step-Rückwärts
Single-Step reverse (SSR)
Single-Step forwards (SSF)
Example 1:
In the AUTOMATIC operating mode it will be traversed along the trajectory of P2 to P3.
Current traversing destination: P3.
After an operating mode change in Single-Step and pressing the SSR key it will be traversed
away in reverse via P2.
All PLC outputs contain their set SSR default status and PLC or TS functions will not be
carried out during the reverse traversing.
It will traverse forwards again between P1 and P2.
As another destination point (P2) as compared to the last current destination point (P3) is
now present, no PLC or TS activities will be executed at first.
Only after reaching point P2 point will all PLC and TS functions be fetched.
If the previous current point is still listed as the traversing destination after an operating mode
change and restart Automatic or Single-Step and if the TCP has not (fundamentally) left the
trajectory, then the fetching of the PLC and TS functions will occur immediately.
Then the TS functions, in which the trajectory criteria have been fulfilled for the current
trajectory, will also be fetched. These will appear immediately and without taking into
consideration any possible delay instructions, as an unknown time has expired during the
interruption and this is normally longer than the maximum delay time instruction (10 sec).
07.03.02
Elektroplanung-und Anlagenbau
Page:9-79
VRS 1
Example 2:
In the AUTOMATIC operating mode it will be traversed along the trajectory from P1 to P2.
Current traversing destination: P2. After an operating mode change in Single-Step and
pressing the SSR key it will be traversed away in reverse via P2. All PLC outputs contain
their set SSR default status and PLC or TS functions will not be carried out during the
reverse traversing.
Afterwards it will traverse forwards again between P1 and P2.
As P2 is still the destination point all PLC or TS functions for all the points that lie in front will
be fetched immediately. Any TS functions for the path from P1 to P2, where in theory the
switching positions have already been overwritten will be immediately executed. The other
TS functions will be switched normally depending on the path that has been traversed and
the expired time just as if the interruption never occurred. Circular or spline trajectories
cannot be set on the programmed trajectory after operating mode changes and the following
restart. Instead it will traverse linearly to the next point. With this modified trajectory the
position (location) of the tool tip will naturally be changed as well, so that it is possible to
execute a trajectory switching function. The path on the circle that had been traversed before
the operating mode changes were made will be added to the path that has been traversed on
the linear trajectory and evaluated.
Operating mode change
and restart
Programmed
circular trajectory
Trajectory
after restart
When "fetching" the PLC and TS functions the statuses of the outputs, the analog channels
as well as the status of internal variables such as flags, markers etc. will be reset. The
current statuses are taken from the dry run via the PLC and TS instructions from point "0" up
to the current previous point. The instructions for each point will be evaluated in the same
order as they are displayed on the hand console during the PLC programming. This
produces the correct dry run results for the normal PLC instructions. As opposed to the TS
functions the execution order for a real time run is not inevitably identical to the programming
sequence (= dry run sequence), as with a real time run both the path as well as the delay
instructions are displayed for evaluation, whereas no more timing reports can be produced
for a dry run.
Page:9-80
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
In order to ensure that the dry run results correspond as much as possible to the real time
run the programming sequence of the TS functions should always correspond to the actual
execution order.
Example:
In a point there are two subordinate TS instructions programmed. The real time end result
invokes the switching off of output 1. The dry run result differs from this as it invokes the
switching on of output 1. An inter-exchange of both instructions would therefore produce a
dry run result in concurrence with the real time result.
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS > O01 = OFF
TS O02 = ON
COPY to
DISPLAY
INSERT BUFFER
EDIT
TS-PARAM DEL.
F1
F2
F3
F4
F5
As the time overlapping of the TS functions of two consecutive points, e.g. a pre-function of
the point P(n+1), that was previously executed as a post-function of the point P(n), can lead
to false dry run results and therefore this must be prevented.
Programming
Functionality
In the "HAND" operating mode the entering of the TS functions are made analogous to the
entering of the normal PLC instructions.
The TS functions normally differ from the PLC instructions in that they are dependent on the
positional and timing of the movement of the robot.
As opposed to the PLC instructions, the TS functions do not depend on being positioned one
below the other as with the normal PLC instructions provided that they have not been mixed
up with each other when they were entered as well as on the screen. Furthermore TS
functions take up more room on the screen as the trajectory path and the delay value must
also be displayed in addition to the normal Boolean or arithmetical value allocations.
•
•
TS functions cannot be programmed in the free running PLCs and in the PLC macros.
The TS functions can be entered or inserted using the PLC editor after any possible jump
and/or traversing condition and before the normal PLC instructions.
The command line contains a "TS>" identifier instead of the customary continual numeration
of the PLC instructions.
Normally the first line after the jump and traversing condition lines is kept free as a
placeholder for the entering of TS functions.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-81
VRS 1
In the empty TS line the four possible types of TS functions can be entered via the selection
menu (see example 1).
The Boolean or arithmetical segments of the TS function are analogous to the relevant PLC
instructions and can be edited with up to a maximum of eight operands. Afterwards the two
new inputting conditions for entering the trajectory path and the delay time are displayed one
after the other.
Example 1: selection menu for entering a TS-function
Sequence: 5
Pnt: 10
TC
JC
S-P
TS > O01 = OUT
TS O02 = IN
OUTPUT
F1
FLAG
F2
PLC-TEACHING
BINARY ANALOG
F3
F4
F5
If the TS line is already occupied, the following options are available via the selection menu:
Pnt: 10
PLC-TEACHING
Sequence: 5
TC
JC
S-P
TS > O01 = OUT
TS O02 = IN
COPY to
DISPLAY
INSERT BUFFER
EDIT TS-PARAM
DEL.
F1
F2
F3
F4
F5
[F1]: Insert a new TS function in front of the current one. A new, empty TS line must be
inserted in front of the current (TS line) one and it must be edited afterwards (see above).
[Shift F1]: Insert a new TS function after the current one. A new, empty TS line must be
inserted after the current (TS-line) one and it must be edited afterwards.
[F2]: Copy the current TS-function to the buffer (buffer fill).
[F3]: Correcting current TS functions. The correcting functions in the same way as correcting
a normal PLC line, however, with the additional menu option: "mm | ms", with which the TS
parameter: Trajectory path or delay time, can be corrected. If a display mode (see below)
change is required for the correction this will be carried out automatically.
[F4]: Display mode change. Mode "Display instructions" (example: 2) function name with
logical or arithmetical instruction. Mode "Display TS params." (Example: 3) function name
with paths and delay parameters.
Page:9-82
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
[F5]: Delete the current TS function. The current TS line will be deleted from the memory and
from the screen. If treated as a single TS line, only the contents will be deleted and the
empty line will be retained as a placeholder for the later entering of TS functions.
Example 2: TS line in display-mode: "Display instructions"
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS > O1
= I04 + I02
TS a2
= Cst + P: - i9 + 9999 mV
COPY to
DISPLAY
INSERT BUFFER
EDIT TS-PARAM
DEL.
F1
F2
F3
F4
F5
Example 3: TS lines in display mode: "Display TS-Params“
Pnt: 10
PLC-TEACHING
Sequence: 5
TC
JC
S-P
TS > O1= Switch point + 1000 mm + 1000 ms
TS a2
= Switch point + 0100 mm + 0050 ms
COPY to
DISPLAY
INSERT BUFFER
EDIT TS-PARAM
DEL.
F1
F2
F3
F4
F5
Example of adhesive programming:
The PLC instructions can be programmed for the relevant movement sequence for new
teaching, correcting or inserting of TCP's. After the teaching of the co-ordinates for a TCP the
PLC instructions can be entered for this point.
The following screen will be displayed after selecting a previously programmed sequence:
Ei 1 - 6 100 % Z1
Hand Î Teaching Î EDIT
SEQUENCE: 5
Pnt: 0
PTP
Vb: 100 %
Ve: 100 %
Aa: 100 %
Ae: 100 %
Jerk: 100 %
Toler.: 200 1/10 deg
PLC
---
F1
07.03.02
COORDI- Interpolation
NATES
F2
F3
Next
point
Continue
F4
F5
Elektroplanung-und Anlagenbau
Page:9-83
VRS 1
]
Press the [F1] function key. The PLC teaching menu will be displayed:
Sequence: 5
TC
JC
S-P
TS
1>
Pnt: 10
OUTPUT MACRO
WAIT
F1
]
F2
F3
PLC-TEACHING
GRIPPER Continue
F4
F5
Use the [Cursor UP] key to move the cursor to the TS line.
Sequence: 5
TC
JC
S-P
TS >
1
OUTPUT
F1
FLAG
F2
Pnt: 10
PLC-TEACHING
BINARY ANALOG
F3
F4
F5
]
After pressing the relevant [F1 - F4] function key you will be taken to the respective
function.
]
Press the [F4] function key when it has been assigned the ANALOG function.
]
Enter the analog output-No.
]
Confirm the entry by pressing the [Return] key. You will be asked whether the value
allocation should be made conditional.
]
Press the [F2] function key if the analog output should be executed without
conditions.
]
Press the [F5] function key. The following screen will be displayed:
Pnt: 10
PLC-TEACHING
Sequence: 5
TC
JC
S-P
TS > a1 ( ? ) Vprop:0
mV
1
Please enter norm. velocity [mm/s] / [10V]
F1
Page:9-84
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
After entering the normal velocity and the offsets enter the trajectory switching
parameter.
]
Trajectory path:
Sequence: 5
Pnt: 10
PLC-TEACHING
TC
JC
S-P
TS > a1 ( ? ) switch point + 0000 mm + 0000 ms
1
Trajectory path ( +/- 9999 ) : 50
[mm]
F1
]
F2
F3
F4
F5
Delay:
Pnt: 10
PLC-TEACHING
Sequence: 5
TC
JC
S-P
TS > a1 ( ? ) switch point + 0050 mm + 0000 ms
1
Delay (-300 / 9999) : -30
[ms]
F1
]
F2
F3
F4
F5
The PLC line is now closed and the PLC teaching menu will be displayed on the
screen.
Sequence: 5
Pnt: 10
PLC-EDIT
TC
JC
S-P
TS > a1
= switch point + 0050 mm - 0030 ms
1
COPY to
DISPLAY
INSERT BUFFER
EDIT
TS-PARAM
DEL.
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:9-85
VRS 1
Hand-F2-F5-F4
The free running PLC
PLC (SPC) = Stored Program Control is an automatic system for controlling, monitoring,
collecting data and processing it as well as providing communications and other process
related tasks.
The controller operates via an integrated mini-PLC, i.e. this stored program controller does
not exist as a customary additional hardware module, but the PLC instructions are
programmed in the [Hand] operating mode executed as point related or free running
instructions in the [Automatic] and [Single Step] operating modes.
The free running PLC can, provided that it has been set to do so, amplify the point related
PLC, as well as administering individual controlling tasks. As opposed to a point related PLC,
the instructions are repeated, i.e. cyclically executed. This makes the free running PLC
especially suitable for monitoring and controlling point independent system statuses (e.g. full
level monitoring of adhesive supply containers).
The PLC instructions are programmed in the [Hand] operating mode in the constants menu
using constant type 490 and automatically executed with the selection of the Automatic or
Single Step operating modes. A free running PLC program will only be stopped by an
operating mode change.
A total of 13 different free running PLC programs can be programmed in the controller,
however only one PLC program can be executed at a time.
The command syntax for the free running PLC is normally identical to the command syntax
used for the point related PLC identical. Commands, that work directly in conjunction with the
robot TCPs, e.g. traversing conditions, gripper functions, wait conditions and jump
conditions, cannot be used with the free running PLCs.
!
]
Note:
With the exception of the PLC marker, all PLC operands for the point related PLCs
and the free running PLCs are identical. This includes: outputs, inputs, flags, sensor
flags, timer, counter and binary outputs. The programmer must ensure that these
operands are not used twice (from the point related and the free running PLC).
In order to program the free running PLC-Programme select constant type 490.
The following screen will be displayed:
Following PLC programs are programmed:
Page:9-86
Current program number: 0
PLC inactive
F1
F4
F2
F3
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The numbers of the previously programmed PLC programs as well as the presently preselected (current) PLC program will be displayed here.
]
In order to be able to set up a new PLC program or correct an existing one, you
must enter the relevant number.
]
Confirm the entry by pressing the [Return] key.
The function keys are now assigned as follows:
[F1] = Edit
[F2] = Copy
[F3] = Delete
[F4] = Cycle time
Following PLC programs are programmed:
Current program number: 1
Edit
Copy
Delete
Cycle
time
F1
F2
F3
F4
F5
Editing free running PLC programs [F1]:
] After pressing the [F1] function key you will be taken to the editor function.
The editor functions essentially correspond to the point related PLC functions.
Edit free PLC : prog – No. 1
1>
2
3
4
5
OUTPUT MACRO
F1
]
F2
PLC-TEACHING
FLAG
ARITH.
VERIF.
F3
F4
Continue
F5
Press the [F5] function key. The function key assignments will be changed as
follows:
COUNTER
TIMER
BINARY
ANALOG
Continue
F1
F2
F3
F4
F5
JUMP
Mark
F1
07.03.02
JUMP
F2
MARKER
F3
Continue
F4
Elektroplanung-und Anlagenbau
F5
Page:9-87
VRS 1
A maximum of 99 PLC instructions (lines) can be programmed in a free running PLC
program.
]
The correcting of an PLC instruction can be carried out after selecting the relevant
line using [Cursor up] and [Cursor down] keys. The selected PLC instruction can
then be modified in the same way as for point related PLCs.
]
When editing large programs with many lines, press [Cursor up] and [Cursor
down] keys in conjunction with the [Shf] key to page forward or backwards.
Copying free running PLC programs
Use the copying function to copy free running PLC programs to the PLC program.
] Select constant type 490.
]
Select the PLC program to be copied.
]
Confirm the entry by pressing the [Return] key.
]
Press the [F2] function key in order to select the copy function. The following screen
will be displayed.
Following PLC programs are programmed:
In which program should it be copied ?
:
01
Source program
Destination program :
F1
F2
F3
F4
F5
You will now be asked to enter the number of the free running PLC program (destination
program), in which the current (source program) one must be copied.
]
Enter the destination program.
]
Confirm the entry by pressing the [Return] key. The PLC program will now be
copied.
Page:9-88
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Deleting free running PLC programs
Use the delete function to delete individual or all PLC programs.
] Select constant type 490.
]
Select the PLC program to be deleted.
]
Confirm the entry by pressing the [Return] key.
]
Press the [F3] function key. The following screen will be displayed:
Delete PLC program No. 05, or
Delete all PLC programs ?
F1
Yes
No
All
F2
F3
F4
F5
[F2] = Yes, the displayed PLC program will be deleted
[F3] = No, the program will not be deleted.
[F4] = All PLC programs will be deleted.
Setting the cycle time
The cycle time, i.e. the time provided for processing all instructions in the PLC programs, can
be modified. This is always required when a new PLC program is set up or modified. The
computing power can be optimised for the PLC mode via the selectable cycle time. Low
cycle times (minimum 15 ms) can be set up for short PLC programs. For programs having a
greater number of instructions, the cycle time must be increased accordingly.
A cycle time of 15ms per 10 PLC instructions is used as the default value during the setting
up.
The following instruction will be displayed after selecting constant type 490 and
pressing the [F4] function key:
]
The cycle time can be a whole number
Should more than 15 ms be used per 10 PLC instrs.
10 PLC instructions require approx. 15 ms.
Cycle time :
015 ms
Smaller
Greater
F1
]
F2
F3
F4
F5
Press the [F2] function key in order to reduce the cycle time (15ms minimum)
07.03.02
Elektroplanung-und Anlagenbau
Page:9-89
VRS 1
]
Press the [F3] function key in order to increase the cycle time (maximum of 15ms)
]
Use the [Return] key to import the new cycle time setting.
Starting a free running PLC program
] Select the [Hand] operating mode.
]
Press the [F2] function key.
]
Select constant type 490 and confirm the entry by pressing the [Return] key.
]
Enter the number of the free running PLC program.
]
Confirm the entry by pressing the [Return] key.
Following PLC programs are programmed:
1 3
Current program number: 1
Edit
Copy
F1
F2
Delete
F3
Cycle
time
F4
F5
The PLC program (e.g. No.1) is the default selection and will be cyclically executed in
[Automatic] and [Single-Step] operating modes.
]
Press the [Esc] key twice in order to return to the main menu.
]
Select the [Single-Step] operating mode. The free running PLC program Nr.1 will
now be cyclically executed.
SSTEP
V : 10 %
Sequence-No.
2
Please enter sequence No.
Pnt-inst
F1
F2
PLC 1
F3
REF-OFF
F4
V in %
F5
The number of the current free running PLC program will be displayed on the right of the 1st
line.
Page:9-90
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Stopping the free running PLC programs
] Select the [Hand] operating mode.
]
Press the [F2] function key.
]
Select the constant type 490 and
confirm the entry by pressing the [Return] key.
]
Enter the No. "0" for the current program.
]
Confirm the entry by pressing the [Return] key.
Following PLC programs are programmed:
1 3
Current program number: 0
PLC inactive
F1
F2
F3
F4
F5
If the program number "0" is selected this deactivates the free running PLC running in
[Automatic] and [Single-Step] operating modes.
]
Press the [Esc] key twice in order to return to the main menu.
]
Select the [Single-Step] operating mode.
SSTEP
V : 10 %
Sequence-No.
2
Please enter sequence No.
Pnt-inst
F1
F2
PLC --
F3
REF-OFF
F4
V in %
F5
]
The PLC program number will not be displayed in the 1st line as there are no free running
PLC programs activated.
In order to save, load or print out the PLC program please read the "Service
program" section in chapter 12 first.
07.03.02
Elektroplanung-und Anlagenbau
Page:9-91
VRS 1
HAND-F2-F5-F5 (500)
PLC operands
In the controller it is possible to use clear text for the individual PLC operands (e.g. inputs,
outputs etc.). These are, for example, for programmed PLC wait or traversing conditions for
the running time of the movement sequence and will be displayed on the screen.
If no commentaries are to be allocated to the PLC operands, the standard message will be
displayed during a wait condition, e.g.:
Wait for: I12 & I2
If the input is to be allocated commentary, the following line will be displayed for the same
wait condition:
Wait for: Temperature contact 1 & ready contact
With this documentation option you can prevent any visual dual loading of a marker or a flag.
Document each PLC operand that is used, in which you have allocated a commentary. Keep
the current print out of the allocations list by the controller.
Select constant No. 500 for entering the PLC commentary. The following screen
will be displayed:
]
The following types of operands can be allocated to any commentary:
•
•
•
•
•
•
Inputs
Outputs
Marker
Sensor flags
Flags
Timer
Read the "500: editing PLC operands" section in chapter 14 "Modifying the
constants" for more information regarding this
Page:9-92
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
10. Single Step
10. Single Step ......................................................................................... 10-1
Operating mode: Single Step ..................................................................... 10-3
Running a programmed sequence............................................................. 10-4
Single Step FORWARDS (SSF)................................................................... 10-5
Continuing with wait or run conditions ..................................................... 10-6
SSF running up to the sequence end (SE) ................................................ 10-7
Single Step STOP (SSS).............................................................................. 10-8
Single Step REVERSE (SSR) ...................................................................... 10-9
SSR run up to the sequence start .............................................................. 10-9
Switching from SSF / SSR in sub-programs ........................................... 10-10
Traversing velocities when the protection lattice are linked out .......... 10-11
Modifying the settings............................................................................... 10-12
Setting the velocity override..................................................................... 10-12
Changing the sequence-No. ..................................................................... 10-12
Online information display ....................................................................... 10-13
Point selection ........................................................................................... 10-15
07.03.02
Elektroplanung-und Anlagenbau
Page:10-1
VRS 1
Page:10-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Operating mode: Single Step
In this operating mode step by step running of an already programmed sequence can be
carried out going forwards (SSF), in reverse (SSR) or with stopping at the next point (SSS).
This operating mode is used when a movement sequence has to be set up or modified. In
this operating mode a sequence should always have its exact run checked. Furthermore, at
reduced velocities possible collisions can be identified in good time and then prevented.
In addition to this an online screen can be displayed in and between the individual TCP's.
Attention! Danger of collisions!
When testing the movement sequences, collisions between the robot and other
devices can occur. Robots, tools, tool pieces or other devices can be damaged or
destroyed by this. Select the traversing velocity at as maximum of 10% only, in
order to identify collisions in good time.
]
Select the [Single Step] operating mode.
The following screen will be displayed:
SSTEP
PLC 1
ACTUATOR POWER OFF
V: 10%
Go to sequence-No.
Sequence-No. 0
Sequence:
Point:
S-P
F1
F2
F3
F4
F5
The following are displayed:
• The operating mode [Single Step]
• The number of the pre-selected, free running PLC program
• The velocity override [F:]
• The conditions for entering the sequence-No. (or the last selected sequence-No.
and point-No., if the [Single Step] operating mode must be reselected after an
interruption).
• The function key assignments.
07.03.02
Elektroplanung-und Anlagenbau
Page:10-3
VRS 1
]
After entering the required sequence-No. (e.g. 1), the following screen is displayed:
SSTEP
PLC 1
---------------------- SEQ001----------------------------ACTUATOR POWER OFF
V: 10%
Sequence: 1
F1
F2
Point: 0
Pnt-instr: REF-OFF
F3
F4
V in %
F5
When velocity override is used the programmed velocity of the sequence is reduced to the
previously entered percentage. The default override velocity is set at 10% of the
programmed velocity.
Running a programmed sequence
In order to run a movement sequence in the [Single Step] operating mode, the drive system
must be switched on.
]
The following screen is displayed after the drive system has been switched on:
SSTEP
PLC 1
---------------------- SEQ001----------------------------V: 10%
Sequence: 1
SSF
SSS
F1
F2
Significance of the function keys:
F1:
SSF
=
F2:
SSS
=
F4:
REF-ON
=
F5:
V in %
=
Point:
F3
0
REF-OFF V in %
F4
F5
Single step FORWARDS
Single step STOP
Sensor mode activated in single step
Modifies the velocity override
You can now run to the "0" point of the selected sequence-No. (sequence-No. 1 here) using
the SSF = "Single Step FORWARDS" function.
Page:10-4
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Single Step FORWARDS (SSF)
When traversing using single step FORWARDS it will run to the current point of the displayed
working sequence from the present position of the robot. The PLC instructions and tong
functions will be executed and the outputs, flags, markers, timer etc. will be controlled.
If the drive system is switched on and the [F1] function key is held down, the robot will
traverse until the key is released ("Jog mode“).
Select a maximum of 10% of the traversing velocity and immediately release the [F1]
function key if there is a danger of a collision occurring. In this case the robot will stop
immediately together with the permanent settings of all axes (drift free).
Furthermore, when traversing in Single Step FORWARDS the robot will be stopped at a point
if the Single Step STOP function has been previously selected.
When changing to the [Single Step] operating mode, the Single step STOP function is preselected as the default. This is displayed on the screen as STOP being selected. If in this
case the robot had reached the "0" position of the sequence, it will remain there under control
of the axes settings.
The following screen will be displayed:
SSTEP
STOP PLC 1
---------------------- SEQ001----------------------------V: 10%
Sequence: 1
SSS
F1
]
F2
Point: 0
REF-OFF
F3
F4
V in %
F5
Pressing the [F2] function key acknowledges the Stop function. The STOP display is
then extinguished and it can now be traversed onto the next point.
Exception:
If the robot is at the "0" position of the sequence as in the example above, it is not possible
to run onto the next point by pressing the [F1] function key = Single step FORWARDS. The
following text will be displayed on the screen: "Wait: sequence start"
This or other wait conditions can be jumped in the [Single Step] operating mode.
07.03.02
Elektroplanung-und Anlagenbau
Page:10-5
VRS 1
Continuing with wait or run conditions
If a TCP is reached whilst traversing in [Single Step] operating mode, you can only leave
this after a wait condition, which is not always given in the alignment mode, has been fulfilled
(wait for sequence start or input etc.) or one of the conditions can be jumped here.
Attention! Danger of collisions!
Wait and run conditions also have another purpose, that is to hold the robot in
position if working materials are found within the movement range of the robot.
Therefore the "Continue" function should only be used when you are sure that this
will not result in a collision.
Example:
When the TCP's "0" position has been reached, you must wait for the start signal (ES 8
sequence start). The following text will be displayed on the screen:
SSTEP
PLC 1
---------------------- SEQ001----------------------------V: 10%
Wait for sequence start !
Sequence: 1
SSF
Continue
F1
]
Point:
F2
0
REF-OFF V in %
F3
F4
F5
In order to continue press the [F1] function key and the [F2] function key as well.
SSF
Cont.
F1
F2
F3
REF-ON
V in %
F4
F5
]
Jump the wait condition by pressing [F1] and [F2] function keys at the same time.
]
Keep the [F1] function key pressed down and you will run on to the next point in the
sequence.
Page:10-6
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
SSF running up to the sequence end (SE)
If the sequence end is reached whilst running in the [Single Step] operating mode, the robot
axes will remain in a drift free state.
The conditions for entering the sequence-No. to be run to next will be displayed on the
screen. Normally the current sequence is proposed.
SSTEP
PLC 1
---------------------- SEQ001----------------------------V: 10%
Sequence-No.
No other point
Sequence: 1
F1
1
Enter sequence-No.
Point: 5
SSR REF-OFF
F2
F3
F4
S-P
F5
]
Press the [Return] key, in order to restart the proposed sequence-No. and run from
point "0".
]
Enter a sequence-No. and confirm the entry by pressing the [Return] key.
or
Attention! Danger of collision!
During Single Step FORWARDS the robot will run directly to the "0" point of the
new sequence.
Note:
Always program the last point and the "0" point for all sequences on the same area
co-ordinates.
Read chapter 3 "Programming conventions" for more information regarding this.
At point "0" the robot remains drift free under the control settings of its axes. The following
menu will be displayed:
]
Press the [Return] key in order to enable the proposed sequence-No.
SSTEP
PLC 1
---------------------- SEQ001----------------------------V: 10%
Sequence-No.
Sequence: 1
SSF
SSS
F1
07.03.02
F2
1
o.k.
Point:
F3
0
REF-OFF
V in %
F4
F5
Elektroplanung-und Anlagenbau
Page:10-7
VRS 1
Single Step STOP (SSS)
With this function the robot axes can be specifically stopped at the next programmed TCP.
SSTEP
STOP PLC 1
---------------------- SEQ001----------------------------V: 10%
Sequence: 1
SSF
SSS
F1
]
F2
Point:
SSR
F3
5
REF-OFF
V in %
F4
F5
Press the [F2] function key.
The Single Step STOP function will be set and displayed on the screen:
The Single Step STOP function can only be activated if the function key is pressed together
with "SSS". The [F2] function key has no significance during running (SSF or SSR) if the
drive system is switched off and within the high accuracy ball.
]
If you press [F1] or [F3] function keys, the robot will traverse according to the next
programmed TCP and will remain in this position drift free.
]
Press the [F2] function key in order to release the stop function.
Pressing the key again reactivates the function for the next point or immediately
traverse to the next programmed TCP by pressing [F1] or [F3] function keys.
Page:10-8
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Single Step REVERSE (SSR)
The application of this function is identical with SSF, however the robot traverses to the
previous TCP (in reverse) here. The PLC instructions and tong functions are ignored during
reverse traversing.
Attention!
As soon as the [F3] function key = Single Step REVERSE is pressed, all PLC
outputs will be reset. Read section 301 output attributes in chapter 14 "Modifying
the constants" for more information regarding this.
If the [F3] function key is held down when the drive system is switched on, the robot will
traverse until the key is released. In this case the robot is immediately stopped under the
permanent control settings of all axes (drift free).
SSR run up to the sequence start
If the sequence start is reached during a reverse traversing, the robot axes will remain in the
drift free state and the following screen will be displayed:
SSTEP
STOP PLC 1
---------------------- SEQ001----------------------------V: 10%
Sequence start SSR not possible
Sequence: 1
Point: 0
SSF
SSS
REF-OFF
F1
]
F2
F3
F4
V in %
F5
Press the [F1] function key in order to run forward in the sequence end direction.
07.03.02
Elektroplanung-und Anlagenbau
Page:10-9
VRS 1
Switching from SSF / SSR in sub-programs
If you have already left the last point of the sub-program in SSF, you can not traverse back
to this last point by switching to SSR.
Example: operating sequence with sub-program jumps
STA RT
0
6 “SE”
C a llS-P N o.
1
2
3
3
4
5
C h a ng e fro m
SSF -> SSR
Po in t “0 ”
3 “S-P”
SUB-PRO G RA M
1
2
Page:10-10
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Linking out the protection lattice
In the [Single Step] operating mode it is possible to carry out the testing of movement
sequences under specific conditions with the protection lattice opened. This can be
necessary in order to see the exact trajectory run or possible collisions in poorly visible robot
operating areas. By adhering to the safety instruction given in DIN EN 775, a person may
remain inside the danger zone for these reasons.
Pay attention to the following safety instructions:
•
•
The linking out of protection lattice is only permitted when the locks provided for this
are used. With these it is guaranteed that the only movements that will be made will
be those controlled by the robot.
Only personnel who are holding the associated hand console with the approval key in
their hands are permitted to enter the dangerous areas.
]
Select the [Single Step] operating mode.
]
In order to enable the linking out of the protection lattice, one of the approval buttons
on the underside of the hand console must be permanently held down (if a
dangerous situation occurs, the drive system will be safely switched off by releasing
the approval button).
Traversing velocities when the protection lattice are linked out
In exceptional cases when the test program must be run at the programmed operating
velocity with the protection lattice opened, it is only possible to do this when the additional
"Single step process velocity" lock is made.
Protection lattice closed:
• Programmed traversing velocity
Protection lattice open:
• Only possible with "Linking out the protection lattice" lock made!
• No movement without the approval key
• Maximum of 25 cm/sec. with the approval key
Process velocity:
• Only possible with "Linking out the protection lattice" and "Process velocity" locks
made!
• No movement without the approval key
• Programmed traversing velocity with approval key.
07.03.02
Elektroplanung-und Anlagenbau
Page:10-11
VRS 1
Modifying the settings
Normally the current sequence and TCP-No. is displayed on the screen and runs at 10% of
the relevant pre-selected velocity V.
If either of the current velocity, TCP-No. or the current sequence-No. has been changed,
proceed as described in both of the following chapters.
Setting the velocity override
In order to set up a velocity override in the [Single Step] operating mode, proceed as
follows:
]
Press the [F5] function key. The inputting field for correcting the velocity override will
be displayed.
SSTEP
PLC 1
---------------------- SEQ001----------------------------Input v:
V: 10%
Sequence: 1
SSF
SSS
F1
]
F2
Point:
F3
(1 - 150)
3
REF-OFF
V in %
F4
F5
Enter the required velocity override via the decimal key and confirm the entry by
pressing the [Return] key.
If a false entry (<1; >150) has been made, the input value for the correction remains the
same on the screen.
The valid velocity override will be displayed, the input text will be deleted.
Only after a movement sequence in [Single Step] operating mode can be run from the first
up to the last point without any problems, should the velocity override be increased step by
step up to 100% (e.g. 5%, 10%, 25%, 50%, 75%, 100%).
Changing the sequence-No.
If the current sequence-No. displayed on the screen must be changed, you do not have to
exit the [Single Step] operating mode. The new sequence-No. can be entered after a "New
start".
If you execute a "New start", all outputs will be reset.
Page:10-12
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Switch the drive system off
]
Press and hold down the [New start] key.
]
Now press the [Joystick] key as well.
]
Release both buttons.
]
Press the [Return] key within the next 2 sec.
After the key has been released, the cursor will appear in the sequence-No. input
field.
]
Enter the required sequence-No.
]
Confirm the entry by pressing the [Return] key.
Online information display
The information display is selected by pressing the [+] key and shows the respective current
status of the following:
•
•
•
•
•
•
•
•
•
•
Inputs
I1 -
Outputs
O1 - O992
Flags
F1 -
Markers
M1 - M24
Math. counter
i0 -
i15
Binary outputs
b0 -
b15
Timer
t0 -
t9
Sensor flags
S1 - S31 (if present)
Pos. error
SLP0 - SLP12
D/A outputs
DA1 - DA15
USet1 - USet12
•
Interbus diagnostics
(if present)
07.03.02
I992
F999
or
Elektroplanung-und Anlagenbau
Page:10-13
VRS 1
This online display is permanently updated.
Vo rw ä rts
bPage
lä tte rn
forwards
Inputs
1 - 32
E1 E5
E9 E13 E17 E21 E25 E29
0000 0000 0000 0000 0000 0000 0000 0000
Outputs
1 - 32
A1 A5 A9 A13 A17 A21 A25 A29
0000 0000 0000 0000 0000 0000 0000 0000
Flags
1 - 32
F1
F5 F9 F13 F17 F21 F25 F29
0000 0000 0000 0000 0000 0000 0000 0000
Marker
1 - 24
M1 M5 M9 M13 M17 M21
0000 0000 0000 0000 0000 0000
Mathematical counter
0-3
i0
0
i1
0
Binary outputs
0-3
b0
0
b1
0
t0
0.0
t1
999.9
Timer
t0 - t4
Page
Rbackwards
ü c kw ä rts
b lä tte rn
Sensorflags
S1 – S32
Pos. error in %
D/A channels
or USet
Interbus diagnostics
Comment regarding
point
i2
0
i3
0
b2
0
b3
0
t2
0.0
t3
0.0
t4
0.0
S1
S5 S9 S13 S17 S21 S25 S29
0000 0000 0000 0000 0000 0000 0000 0000
SLP A1 - A6
0% 0%
0%
a0
+0mV
0%
a1
a2
+0mV +0mV
0%
0%
a3
+0mV
IBM Diag.
Module: BUS Status =
Comment regarding point
A maximum of 32 bits can be displayed in the online screen. Use the ↑ and → cursor keys to
display the next 32 bits and the ↓ and ← keys to display the previous 32 bits.
Page:10-14
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Point selection
In the "Single Step" operating mode it is now possible to select any point in the current
sequence or sub-program when the drive system is switched off. The "Drive system off"
status screen contains the caption: Pnt-instr. for the [F3] function key.
If you press this key the "Pnt. number: " report will be displayed. A new point number can
now be selected.
SSTEP
PLC 1
---------------------- SEQ001----------------------------ACTUATOR POWER OFF
V: 10 % Pnt.number:
Sequence: 1
F1
F2
Point: 3
Pnt-instr. REF-OFF
F3
F4
V in %
F5
In this status the [F5] function key (V in % ) remains blocked until the point number inputs
are finished by pressing [Return].
After being entered the new point number will be checked to see whether the selected point
number is already present in the sequence or sub-program. If the entered point number is
greater than the number of the programmed points, then the last point of the sequence / UP
will be selected.
The velocity override will be set to 10%!
The selected point must now be traversed under the "Single Step" mode control settings.
Previously an operating mode change to automatic was not possible.
The point selection via TEACHIN -> Correction -> point is no longer active. This enables all
points in manual mode to be seen without returning to the "Single Step" operating mode and
having to carry out a point selection. However, if the co-ordinates for a TCP in the current
sequence have been modified in correction mode, the point number of the last corrected
point will be taken in "Single Step".
07.03.02
Elektroplanung-und Anlagenbau
Page:10-15
VRS 1
Page:10-16
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
11. Automatic
11. Automatic ........................................................................................... 11-1
The automatic operating mode .................................................................. 11-3
Interruptions ................................................................................................ 11-4
Switching back on after an interruption .................................................... 11-4
Retaining the PLC outputs.......................................................................... 11-5
during drive OFF or EMERGENCY-OFF..................................................... 11-5
Ramp brakes in automatic .......................................................................... 11-5
Interruptions caused by system errors ..................................................... 11-6
Interruptions caused by timeouts .............................................................. 11-7
Retaining the free running PLC.................................................................. 11-8
Changing the velocity override online....................................................... 11-8
Online information display ......................................................................... 11-9
Remote diagnostics .................................................................................. 11-11
Diagnostic code table ............................................................................... 11-14
Example: evaluation of system errors by the free running PLC............ 11-15
Example of a peripheral error................................................................... 11-15
07.03.02
Elektroplanung-und Anlagenbau
Page:11-1
VRS 1
Page:11-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The automatic operating mode
In the [Automatic] operating mode the robot automatically traverses from a previously
programmed (taught) operating sequence.
Depending on the sequences selected via the PLC and the sequence start signal, the
selected operating sequence in this operating mode will always traverse with the same
precision.
The robot axes will remain at point "0" of the selected sequence (held under drift free
conditions) until the start signal (system input ES 8, sequence start) is given.
After the start signal the point sequence will run up to the end and there it will wait at point "0"
of the next selected sequence until the new start signal arrives.
]
Select the [Automatic] operating mode.
The following screen will be displayed:
AUTO
PLC 1
ACTUATOR POWER OFF !
V: 100%
Sequence: 1
Point:
0
V in %
F1
F2
F3
F4
F5
The following are displayed:
the selected sequence-No. or S-P No.
the current point-No.
the velocity override in %
the activated free PLC program
the system name (if programmed in)
the station name (if programmed in)
the sequence name (if programmed in)
!
The velocity override always refers to the programmed velocity.
During the operation the display will be updated as it moves from point to point.
07.03.02
Elektroplanung-und Anlagenbau
Page:11-3
VRS 1
Interruptions
An interruption to the movement sequence can be caused by:
Switching of the drive system at the manual control panel
Activating an EMERGENCY-OFF button
Opening a protection grill
If the robot's traversing program is interrupted, the drive systems as well as the operating
materials enable (KC2A/B) will be switched off safely.
Switching back on after an interruption
When switching the drive systems back on, the operating materials will be enabled at the
same time and will traverse to the exact TCP in this precision radius it was at when it was
switched off.
If the robot was on a trajectory outside the precision radius when it was interrupted, then
after the drive system has been switched back on a resetting of the programmed trajectory
will be carried out.
This will guarantee that the following point will be reached precisely on the programmed
trajectory ("precise contour resetting"). This precise traversing prevents the wrong traversing
path from being used and the contour deviation is enlarged to correspond with the
programmed precision radius.
If after an interruption the robot is found to be no longer on the programmed trajectory (e.g.
through manual operation), then the following screen will be displayed when the automatic
operating mode is selected:
AUTO not possible! Select S-STEP
Quit error ESC/MOS:
F1
F2
F3
F4
F5
The automatic operation is only possible after first having traversed onto the next point in
[Single Step] operating mode.
This "Start locked out" in [Automatic] operating mode is very practicable with complex
systems as it prevents any possible collisions, especially if the robot is no longer on the
programmed trajectory. The monitoring of the start lock out can be switched off by using
constant 213 for test purposes. When the drive system is switched on the robot will always
traverses from the current position to the current point of the selected sequence.
!
In each case, after any change of operating mode and before a restart the robot axes
must be traversed in the proximity of the point being left or the new point that it must
traverse onto in order to prevent a collision.
Page:11-4
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Retaining the PLC outputs during drive OFF or EMERGENCY-OFF
If the automatic program is interrupted, the original statuses of the PLC outputs are retained
even after a restart of the drive system.
Exception:
If it is found during cyclic checks of the robot axes after the drive system has been switched
off that an axis has gone outside of the tolerance area from the 'switch off point' before it
stopped, all outputs will be reset to '0'!
This tolerance range is obtained from
FACTOR x Bandwidth
With automatic traversing
(constant 213 = ON) this FACTOR = 2
With start locked out
(constant 213 = OFF) this FACTOR = 10
Ramp brakes in automatic
In order to protect the robot mechanics and the tools being used when the drive system is
switched off, an option for using the ramp brakes exists. When the ramp brakes are applied
the robot will be stopped using the maximum permitted deceleration. This ensures that the
TCP remains on the programmed trajectory when stopped.
The ‘ramp brakes’ function is activated with system input ES 15.
For safety reasons the ramp brake function is only activated in the [Automatic] operating
mode. In [Hand] and [Single Step] operating modes the ramp brakes are always switched
off.
!
Note:
This function should not be changed, then the operating life of the mechanics will
not be affected.
In the following cases:
EMERGENCY-OFF
Drive system off
K2 error (machinery safety circuit)
Operating mode change
The ramp brakes operate in [Automatic] operating mode, provided that this has been
selected.
For safety reasons the robot will always be stopped without using the ramp brakes in all
other cases.
07.03.02
Elektroplanung-und Anlagenbau
Page:11-5
VRS 1
Interruptions caused by system errors
If a control error occurs in the automatic operating mode, the drive system and the operating
material enable will be immediately switched off (no ramp braking!).
The following can cause a system error:
Machinery safety circuit open (K2)
Servo amplifier error (K46)
Wait relay error (K6/K7)
Position error, B-width error
Axis angle limit exceeded
Trajectory module error (e.g. point not attainable)
Further system errors can be found in the diagnostic code table in this chapter.
The relevant error cause will be display on the screen and must only be eliminated by
suitably qualified personnel.
]
After eliminating the cause of the error, the error report must be acknowledged with
the [Esc] key.
If none of the axes have exceeded their maximum tolerance ranges at the time of being
switched off', the drive system can be switched back on again.
The maximum tolerance range of an axis is the same as the B-width of the axis.
If the program was interrupted by an error in the system, all PLC outputs retain their current
values. The D/A channels are set to "0".
After the system error has been acknowledged, a dry run for the point related PLC will take
place and the outputs will be reset to the current values.
Read the "Retaining the outputs during an interruption" section in chapter 9 "PLC
Programming" for more information.
Page:11-6
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Interruptions caused by timeouts
If the robot is waiting at a point for a programmed wait condition that has not yet been
fulfilled, after the pre-entered waiting time has expired, the drive system will be switched off
(energy saving function).
As soon as the wait condition is fulfilled and the safety circuit (K1a + K1b) is also closed
again, the drive system will be automatically switched back on again and the interrupted
program will be continued.
AUTO
PLC 1
ACTUATORS OFF - TIMEOUT
V: 100%
Wait for:Start - quit
Sequence: 1
Point:
0
V in %
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:11-7
VRS 1
Retaining the free running PLC
As opposed to the point related PLC, the free running PLC remains active during an
interruption in the [Automatic] operating mode, providing that it is not the cause of the
system error. If a system error occurs this makes it possible to continue to evaluate the
results of peripheral devices. The number of presently active free running PLC programs will
be displayed in the upper right of the screen.
Changing the velocity override online
The percentage of the pre-entered velocity override (V) can be modified directly during the
traversing (online).
]
Press the [F5] function key. The input field for the velocity override corrections will
be displayed.
AUTO
PLC 1
---------------------- SEQ001----------------------------Input V:
V: 100%
Sequence: 1
Point:
(1 - 150)
3
V in %
F1
F2
F3
F4
F5
]
Enter the value for the required velocity override (1 - 150%).
]
If the entry is incorrect, the original entry text will remain on the screen.
]
Otherwise the valid velocity override will be displayed and the entered text will be
cleared.
Page:11-8
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Online information display
The information display can be selected by pressing the [+] key and displays each of the
current set or cleared statuses:
•
•
•
•
•
•
•
•
•
•
Inputs
I1 -
Outputs
O1 - O992
Flags
F1 -
Markers
M1 - M24
Math. counter
i0 -
i15
Binary outputs
b0 -
b15
Timer
t0 -
t9
Sensor flags
(if sensor module is loaded)
Pos. error
SLP0 - SLP12
D/A outputs
DA1 - DA15
USet1 - USet12
•
Interbus diagnostics
(if present)
07.03.02
I992
F999
or
Elektroplanung-und Anlagenbau
Page:11-9
VRS 1
This online display is permanently updated.
Vo rw ä rts
bPage
lä tte rn
forwards
Inputs
1 - 32
E1 E5
E9 E13 E17 E21 E25 E29
0000 0000 0000 0000 0000 0000 0000 0000
Outputs
1 - 32
A1 A5 A9 A13 A17 A21 A25 A29
0000 0000 0000 0000 0000 0000 0000 0000
Flags
1 - 32
F1
F5 F9 F13 F17 F21 F25 F29
0000 0000 0000 0000 0000 0000 0000 0000
Marker
1 - 24
M1 M5 M9 M13 M17 M21
0000 0000 0000 0000 0000 0000
Mathematical counter
0-3
i0
0
i1
0
Binary outputs
0-3
b0
0
b1
0
t0
0.0
t1
999.9
Timer
t0 - t4
Page
Rbackwards
ü c kw ä rts
b lä tte rn
Sensorflags
S1 – S32
Pos. error in %
D/A channels
or USet
Interbus diagnostics
Comment regarding
point
i2
0
i3
0
b2
0
b3
0
t2
0.0
t3
0.0
t4
0.0
S1
S5 S9 S13 S17 S21 S25 S29
0000 0000 0000 0000 0000 0000 0000 0000
SLP A1 - A6
0% 0%
0%
a0
+0mV
0%
a1
a2
+0mV +0mV
0%
0%
a3
+0mV
IBM Diag.
Module: BUS Status =
Comment regarding point
A maximum of 32 bits can be displayed in the online display. Use the ↑ and → cursor keys to
display the next 32 bits and the ↓ and ← keys to display the previous 32 bits.
Page:11-10
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
By pressing the [Cursor UP] or [Cursor DOWN] keys other values will be displayed
in each selected screen:
Inputs
(33 - 64 etc.)
Outputs
(33 - 64 etc.)
Flags
(33 - 64 etc.)
Math. counter
(i4 - i7 etc.)
Binary
(b4 - b7 etc.)
Timer
(t5 - t9)
Sensorflags
(S1 - S31)
Pos. error
(axes 6 - 12)
D/A channels
(DA4 - DA7) or (USet5 - USet8 etc.)
Interbus diagnostics
Comment regarding point
Remote diagnostics
When using remote diagnostics for complex systems the causes of errors that have resulted
in the robot being stopped or the robot drive system being switched off can be determined
and corrected with help from the superior system.
Possible causes:
Hardware failure
z
Computer
Software failure
z
Breakdown in the safety circuit
z
Peripherals z Waiting for a condition to be fulfilled (contact is ON, contact is OFF)
When one of the listed causes occurs, the computer will control the relevant system outputs
and the logical status of the reason for the breakdown can be signalled in binary code.
Read the code table at the end of this chapter for more information.
This code can be interpreted using flags F969 - F983 in the free running PLC or can be
passed on to an external PLC via the inter-bus interface.
The error code will be displayed together with the system outputs AS 9 - AS 15, the so called
diagnostic bits.
As a result of the hexadecimal code, system outputs AS 9 - AS 15 are assigned the following
significances:
AS 9
AS 10
AS 11
AS 12
AS 13
AS 14
AS 15
07.03.02
=
=
=
=
=
=
=
significance 1
significance 2
significance 4
significance 8
significance 16
significance 32
significance 64
(20)
(21)
(22)
(23)
(24)
(25)
(26)
Elektroplanung-und Anlagenbau
Page:11-11
VRS 1
If the significance's for the diagnostic bits are added in the result is the corresponding error
code-No.
In addition, in conjunction with system output AS 5 (flag 973) and AS 7 (flag 975), the inputNo. will be displayed in code, whilst waiting for the condition (ON or NOT ON) to be fulfilled.
Systemoutput
Status
Significance
AS 5
Set (1)
Identification of peripheral report
(e.g. waiting for an input)
Not set
(0)
Identification of cause of
computer error (e.g. hardware
failure)
Waiting for input 'ON'
AS 7
(Only in
conjunction
with AS5 = set
by significance
Set (1)
Not set
(0)
AS 1
Waiting for input 'NOT ON'
Error value parity
This system output is used for
function checking of the
diagnostic bits and is set by the
computer to ON, as soon as an
even number of bits of the error
report to be generated are set to
ON. Consequently the number
of uneven (ODD parity) bits will
be expanded and the relevant
checks can point to a system
output error or an error
occurring when transferring to
an external PLC.
Page:11-12
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The well known VW-diagnostic occupies one word. As a result of the I/O expansion to 992, 3
other bits have now been added, so that a “Wait for contact 992” can be exported as a bit
value. The following table shows the bit assignments within this diagnostic word.
Bit number
Wait “E745”
ON
0
1
1
0
2
0
3
1
4
0
5
1
6
1
7
1
8
0
9
ON/ Parity
Wait/ OFF
ERR
1
1
1
1
The “Wait/ERR” bit sets bit-No. 10, the “ON/OFF” bit sets bit-No. 11 and the “Parity” bit sets
bit-No. 12.
This code can be interpreted in the free-running PLC using the flags or be exported to an
external PLC via the interbus-S.
07.03.02
Elektroplanung-und Anlagenbau
Page:11-13
VRS 1
Diagnostic code table
Significance
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Peri=
ON/
ODD
0
0
0
0
0
0
0
0
0
0
pheral
OFF
parity
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
9
10
11
12
13
14
15
16
17
18
5
7
1
or
or
or
or
or
or
or
or
or
or
or
or
or
flag
flag
flag
flag
flag
flag
flag
flag
flag
flag
flag
flag
flag
977
978
979
980
981
982
983
984
985
986
973
975
969
Everything OK
8
Program error (Task
terminated)
Computer error
(Bus error)
Waiting for sequence
start signal
Free
8
Wrong sequenceNo..
8
‘AUTOMATIC’
operating mode
protection error
No trajectory module
available
Error in sequence
‘Process velocity’
error
‘Linking out
protection grill’ error
Constant memory
protection error
Error servo-amplifier
K46
Resolver error, wait
relays K6/K7, serial
bus
B-width error, pos.
error, axis-angle limit
velocity
Error safety circuit
K2
Drive system
switched off by
timeout
Page:11-14
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Example: evaluation of system errors by the free running PLC
The free running PLC can make an evaluation of the error diagnostics using the relevant
flags and can, for example, operate a warning light via one of the outputs.
Command
Description
t0 (!F01) = -5
Timer t0 starts with -0.5 sec
F01= t0 < 5
Timer new start at t0 >= 0.5 sec
M01= F977 + F978 + F979 + F980
Evaluate diagnostic bits
A016= M01 &! F973 & T0
Set output, when there is no peripheral error
and timer is positive
Example of a peripheral error
A peripheral error occurs when waiting for an input in a movement sequence, until this
assumes a specific status.
e.g. via the PLC line: 1: Wait until E09
With the remote diagnostics, a peripheral error can always be recognised via the setting
system outputs AS 5. The diagnostic bits then give a dual coding of the number of the inputs
whilst waiting for this status change.
07.03.02
Elektroplanung-und Anlagenbau
Page:11-15
VRS 1
If the AS 7 system output is set, waiting for the corresponding input to be set.
In the opposite case, if AS 7 is not set, you must wait for the inputs to be reset.
Examples
WAIT for
E9 = ‘ON’
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Bit
Peri=
ON/
ODD
0
1
2
3
4
5
6
7
8
9
pheral
OFF
parity
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
AS
9
10
11
12
13
14
15
16
17
18
5
7
1
or
or
or
or
or
or
or
or
or
or
or
or
or
flag
flag
flag
flag
flag
flag
flag
flag
flag
flag
flag
flag
flag
977
978
979
980
981
982
983
984
985
986
973
975
969
X
X
X
X
X
X
X
X
X
X
X
WAIT for
E10 =
‘OFF’
WAIT for
E11 =
‘OFF’
X
WAIT for
E777 =
‘ON’
X
Page:11-16
X
X
Elektroplanung-und Anlagenbau
X
X
X
X
07.03.02
X
VRS 1
12. Service program
12. Service program................................................................................. 12-1
Service program .......................................................................................... 12-3
Printing ......................................................................................................... 12-5
Setting the baud rate ................................................................................... 12-6
The individual functions are described afterwards. ................................ 12-6
Printing the assignment lists...................................................................... 12-7
Printing the robot constants....................................................................... 12-7
Printing the PLC macros and the free running PLC programs............... 12-8
Printing the PLC macros............................................................................. 12-8
Printing the free running PLC programs ................................................... 12-8
Printing the point lists (sequences, sub-programs) ................................. 12-9
Formatting.................................................................................................. 12-11
Formatting a floppy disc (FD)................................................................... 12-11
Formatting an SRAM disc (RD) ................................................................ 12-13
Copying sequences to RD & RAM............................................................ 12-17
Duplicating special functions................................................................... 12-18
Insert mode (default setting) .................................................................... 12-18
Overwrite mode ......................................................................................... 12-18
Overwrite co-ordinates only mode........................................................... 12-19
Change co-ordinates only overwrite mode ............................................. 12-19
Saving / loading / comparing / deleting ................................................... 12-20
Marking....................................................................................................... 12-20
Marking sequences ................................................................................... 12-21
Marking of constants ................................................................................ 12-22
Saving......................................................................................................... 12-23
Loading....................................................................................................... 12-24
Error codes generated when reading in the seq. from FD, RD & RAM . 12-26
General information regarding logbooks ................................................ 12-27
Reading the logbook ................................................................................. 12-27
Saving the logbook to a floppy disc ........................................................ 12-28
Reading the logbook from a floppy disc ................................................. 12-29
Loading a new operating system using CPU 30 Rev 4........................... 12-30
Setting the time and date .......................................................................... 12-32
Updating from Version 1.13 or 1.14 to Version 2.0 ................................. 12-33
Loading and activating the auxiliary module .......................................... 12-35
Loading, saving, ........................................................................................ 12-36
deleting and activating the sensor module: ............................................ 12-36
Network configuration............................................................................... 12-39
Commissioning.......................................................................................... 12-39
Loading and saving a network configuration ......................................... 12-42
Modifying a network configuration .......................................................... 12-42
Deleting Multi-Point files from the RAM – disc ....................................... 12-43
07.03.02
Elektroplanung-und Anlagenbau
Page:12-1
VRS 1
Page:12-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Service program
Hand-F4
Service functions for administration, archiving and the printing out of sequences and
constants have been included in the service programs.
In addition there are also functions available for use for the formatting of storage mediums,
logbook functions and the loading of a new operating system.
]
The following menu will be displayed after selecting the [Hand] operating mode and
pressing the [F4] function key:
1st level:
SERVICE PROGRAM Floppy
F1= Load / Save via NETWORK
F2= Load / Save via FLOPPY
F3= Rd -> Multipoint files
F5=Continue
NET
W i
F1
]
2
nd
FLOPPY
Rd
F2
F3
F4
F5
Press the [F5] function key to jump to the next operating level.
level:
SERVICE PROGRAM
F1 = Print
F2 = Format FD / RD
F3 = Copy SEQUENCE to RD & RAM
F4
F5 = Continue
Print
F1
]
Format
F2
Copy.
F3
Up/down
F4
Continue
F5
Press the [F5] function key to jump to the next operating level.
rd
3 level:
SERVICE PROGRAM Log book
F1 = Read log book
F2 = Save log book to floppy disc
F3 = Read log book from floppy disc
F4 = Load new operating system
F5 = Continue
07.03.02
Read
Save
from FD
F1
F2
F3
Continue
F4
F5
Elektroplanung-und Anlagenbau
Page:12-3
VRS 1
]
Press the [F5] function key to jump to the next operating level.
th
4 level:
Z
General SERVICE PROGRAM
F1=Reset the time and date
F2=Load & activate the auxiliary module
t
d l l dconfiguration
kti i
F3=Network
F5=Continue
Time
F1
Module
W i
F2
Network
F3
Continue
F4
F5
]
Press the [F5] function key to return to the initial service program menu.
]
Select the required service program by pressing the relevant [F1] - [F5] function key
in the respective menu.
Page:12-4
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Printing
Hand-F4-F1
In order to optimise, correct or document complex robot traversing programs it can be a great
help to make a print out via a connected printer of the programmed TCP as well as the
associated additional information in listed form (log).
The following information can be printed out:
•
•
•
•
•
•
•
PLC operands assignment list
Constants
PLC macros
Free running PLC programs
Sequence and sub-program point lists
Co-ordinates for the point lists
Additional information for the point lists
It can also be printed out from a network drive or from a disc. The file “VRSPRINT.TXT” is
automatically loaded for this.
A printer can be connected and used via the serial port. If a relevant printer is unavailable, a
standard PC can be connected via a serial cable (RS 232 / null modem cable). This PC will
require a terminal program (e.g. ‘Terminal’ under WINDOWS),
to receive the print data. The following list of parameters must be set in the terminal program
for the data transfer.
The connection is found on the CPU board, port 2.
Asynchronous, serial data interface in accordance with I/O standard RS 232 C DIN standard
V24. 9 pin plug,
Pin assignments
Pin 1:
Pin 2:
Pin 3:
Pin 4:
Pin 5:
Pin 6:
Pin 7:
Pin 8:
Pin 9:
Parameter settings
DCD NC
RxD Receive
TxD Send
DTR NC
Ground
DSR NC
RTS Ready to send
CTS Clear to send
Ground
07.03.02
Baud rate: 1200 baud
Stop bit: 2
Data bit: 7
Parity: none
Hardware-handshake
via RTS/CTS
Elektroplanung-und Anlagenbau
Page:12-5
VRS 1
Setting the baud rate
] The following menu will be displayed after selecting the [Hand] operating mode and
pressing the [F4] function key and then pressing the [Shift] and [F1] function keys
at the same time:
Please select the BAUD RATE
1200
F1
9600
F2
F3
19200
F4
F5
]
Press the respective function key to initialise the relevant setting.
]
The following menu will be displayed after selecting the [Hand] operating mode and
pressing the [F4], [F5] and [F1] function keys:
DRUCKEB
ueber
Service program
F1=Print from NETWORK
F2=Print from FLOPPY
F3=Print via Port 2
NETWORK FLOPPY
F1
F2
Port 2
F3
Continue
F4
F5
The function keys have the following significances:
• Print to an unrestricted network drive or directory
• Print a file called VRSPRINT.TXT to a disc
(The VRSPRINT.TXT file is loaded automatically!)
• Print selected files via a local printer
]
The following menu is displayed after the [F3] function key is pressed:
DRUCKEB
ueberport 2
PRINT
via serial
F1 = Instruction list
F2 = Constants
F3 = Macros / free running PLC programs
F4 = Point list incl.PLC information
F5 = All information
Inst/list
Constants
PLC
Points
All
F1
F2
F3
F4
F5
The individual functions are described afterwards.
Page:12-6
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F4-F1-F1
Printing the assignment lists
During programming the assignment lists can give a better overview of the unused PLC
operands (inputs, outputs, markers, sensor constants, flags and timer) and prevent double
assignments from being made. All PLC operands that have been assigned a commentary
under constant type 500 will be printed out in the assignment list.
Place a copy of the current assignment list in each switching cabinet, in order to have a
handy overview of the PLC operands being used when, for example, making corrections.
If no PLC operands have been entered, then the assignment list can be used as a standard
form on which all outputs (O01 - O16) and inputs (I01 - I16) available for use are listed. If
several I/O boards are fitted, the corresponding number of the boards will be given in the list
out. In this standard form the programmer can mark the input and output assignments by
hand, in order to enter them later on in the constant type 500 as PLC operands.
]
The following screen is displayed after pressing the [F1] function key:
PRINT the assignment list
Print
F1
]
F2
F3
F4
F5
Press [F1] and the assignment list will be printed out.
Hand-F4-F1-F2
Printing the robot constants
All of the robot constants will be printed out in this log.
]
Press the [F2] function key to print out the log.
PRINT via seria port 2
F1 = Instruction list
PRINT the constants
F3 = Macros
F4 = Point list incl. PLC information
F5 = All information
07.03.02
Inst/list
Constants
PLC
Points
F1
F2
F3
F4
All
F5
Elektroplanung-und Anlagenbau
Page:12-7
VRS 1
Hand-F4-F1-F3
Printing the PLC macros and the free running
PLC programs
Both the programmed PLC macros and the free running PLC programs can be printed out
using this menu option.
PRINT via serial port 2
F1 = PLC macros
F2 = free running PLC program
Macro
PLC prog
F1
F2
F3
F4
F5
Hand-F4-F1-F3-F1
Printing the PLC macros
All PLC macros together with their programmed contents will be displayed in this log.
]
The programmed PLC macros will be printed out after the [F1] function key is
pressed:
PRINT via serial port 2
PRINT PLC macros
F2 = free running PLC program
Macro
PLC prog
F1
F2
F3
F4
F5
Hand-F4-F1-F3-F2
Printing the free running PLC programs
All free running PLC programs together with their programmed contents will be displayed in
this log.
]
Press the [F2] function key to print out the programmed free running PLC programs.
PRINT via serial port 2
F1 = PLC macros
PRINT free running PLC program
Macro
F1
Page:12-8
PLC prog
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F4-F1-F4
Printing the point lists (sequences, sub-programs)
With this function you can print out the programmed sequences and sub-programs. The
content of the printed log can be individually assembled for a single sequence or for all
programmed sequences and sub-programs.
The following information will always be printed out:
• Point-No. (point)
• Interpolation (method)
• Tool-No.
• Sub-program call
The following information can be individually selected for the point lists:
•
Point info
Trajectory, end velocity, start, end accelerations, jerking/filter, accuracy.
•
Co-ordinates
Position TCP (X-, Y-, Z), orientation (RPY angle), axis angle (a, b, c), (24 bit) for
axes 1 - 12.
•
PLC
Programmed traversing conditions, jump conditions, PLC lines and macro calls.
•
Additional information
Additional information such as programmed weave parameters, search functions, sensor
commands and TCP commentaries.
The ‘Point’ ‘PLC’ and ‘Additional’ functions are selected as the defaults.
PRINT point lists
From sequences and sub-programs
Sequence No: 1
POINT
PLC
[F1]
ADDITIONAL
Print
Continue
All
F1
F2
F3
Mode
F4
F5
[F2]
All programmed points (point-No., point type), all associated programmed PLC lines
(PLC) as well as the additional information (Add-inf.) can be printed out from the
sequence / S-P Nos. displayed on the screen.
Page through to select the required sequence / S-P No.
[F3]
After being selected, all sequences and sub-programs will be printed out.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-9
VRS 1
[F5]
]
[F1] – [F5] function key assignments; the information to be printed out can now be
selected from the assignments, which can be activated or de-activated by repeated
pressing of the respective function key.
PLC
ADDIT.
POINTS
COOR
ESC
F1
F2
F3
F4
F5
Press the [F5] function key to display the previous menu and the printing process can
be started using the selection that has been made.
Page:12-10
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Formatting
Hand-F4-F2
The programmed operating sequences can be saved to an SRAM-disc (RD) in the controller.
In order to save data or to save a previously programmed program for the same robot
application from having to be re-programmed, the program can be transferred (copied) to a
portable storage medium.
]
The following selection menu will be displayed after selecting the [Hand] operating
mode and pressing the [F4], [F2], [Continue] and [F2] function keys:
SERVICE PROGRAM Format
F1 = Format FD
F2 = Format RD
Form FD Form RD
F1
F2
F3
F4
F5
]
Press the [F1] function key to display the menu for formatting the floppy disc (FD).
]
Press the [F2] function key to display the menu for formatting an SRAM disc (RD).
Hand-F4-F2-F1
Formatting a floppy disc (FD)
The formatting of the disc involves deleting all of the data such as sequences, constants,
macros etc. that was previously saved on the disc.
!
]
Important information:
It is not possible to format HD discs with a Rev.3 CPU, therefore only 3.5'' DS/DD
floppy discs can be used.
The following text will be displayed after pressing the [F1] function key:
Service prog. Î Format FD Í
Please put a new disc in the drive !
All data will be completely deleted !
Select format !
(ESC = Abort)
DOSHD
F1
07.03.02
DOSDD
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:12-11
VRS 1
]
After the [F1] function key has been pressed, the HD - disc that has been placed in
the drive will be tested initially and afterwards it will be formatted in the DOS –
format. The following screen will be displayed:
Please wait !
Formatting . . .
F1
]
F2
F3
F4
F5
The following menu will be displayed after the disc has been formatted successfully.
Editing directory names
Max 4 entries of 8 characters each
Entry 1: ROBO_1
Entry +
Edit
Continue
F1
F2
F3
F4
F5
The function keys can be used for the following options:
[F1] select a directory,
[F2] edit a directory name or
[F3] terminate the formatting process
]
After the [F5] function key has been pressed, the DD - disc that has been placed in
the drive will be tested initially and afterwards it will be formatted in DOS – format.
The same screen as for DOS-formatting will be displayed.
After the formatting has been successfully completed, the main menu will be displayed and
other discs can be formatted. If an error occurs, an error report will be displayed on the
screen.
Page:12-12
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F4-F2-F2
Formatting an SRAM disc (RD)
The formatting involves the deletion of all data previously saved in the SRAM disc, i.e.:
• All system data
• All sequences
• All constants
• Sensor or
• Transformation modules that were loaded afterwards
The formatting of the SRAM is only possible in conjunction with a key-disc!
]
After selecting the [Hand] operating mode and pressing the [F4], [F2] and [F2]
function keys the checking of the key-disc that has been placed in the drive will take
place.
Service prog. Î Format RD Í
Data in RAM-DISC will be completely deleted
Please put the key disc in the drive
Acknowledge with F1
F1
F2
F3
F4
F5
]
Acknowledge by pressing the [F1] function key.
]
The menu for starting the formatting will be displayed:
Service prog. Î Format RD Í
Data in RAM-DISC will be completely deleted!
Select format !
(ESC = Abort)
MSDOS
F1
]
F2
F3
F4
F5
Press the [F1] function key and a RESET will be carried out and the system will be
restarted.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-13
VRS 1
]
The following menu is displayed after the restart:
Service program -> RD formating <-
ATTENTION!!! RAM – DISC will be reformatted
Acknowledge with F1
F1
]
F2
F3
F4
F5
The RAM-disc will be reformatted after the [F1] function key has been pressed and
the following menu will be displayed:
Constants missing!
PTP default constants
will be loaded
Acknowledge with F1
F1
F2
F3
F4
F5
Afterwards the system will display this screen:
]
Enter the date and time
Date : 11 / 10 / 98
Time : 08:30:00
Are the date and time correct ?
(F1 = YES)
CORRECT NEW
F1
F2
F3
F4
F5
]
You now have the option to confirm the displayed date and time by pressing [F1].
]
After acknowledging by pressing the [F2] function key you will be required to enter
the current date and time.
Enter the date and time
Page:12-14
Day
Month
Year
Hour
F1
F2
F3
F4
Minute
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Enter the date and the time and confirm your entries by pressing the [Return] key. If
the entry is wrong you will be offered the chance to repeat the entries.
]
Press the [F1] function key. The following information will be displayed:
Enter the date and time
Date : 11 / 10 / 98
Time : 08:30:00
Are the date and time correct ?
(F1 = YES)
CORRECT NEW
F1
]
F2
F3
F4
F5
The following menu will be displayed:
ATTENTION! : System constants are missing
Default constants will be loaded
Restandardise the system model !
Acknowledge with F1
F1
]
F2
F3
F4
F5
The following menu will be displayed after confirming by pressing [F1]:
RAM–error!
Manipulator will traverse in AUTO to the start point
Manipulator manual free traversing !
Acknowledge with F1
F1
]
F2
F3
F4
F5
After you have acknowledged by pressing the [F1] function key, the control system
will be started.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-15
VRS 1
]
The following menu is displayed next:
Network configuration has been changed
Update from BattRAM using F1
Update from RD using F2
F1
F2
F3
F4
F5
]
Press the [F1] function key and the system will try to reactivate a network
configuration that was set-up and saved previously.
]
If it cannot find a network configuration, press the [F2] function key.
Please read the section about setting up a network configuration which appears
later on in this chapter
Page:12-16
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Copying sequences to RD & RAM
Hand-F4-F3
With this service program you can:
• Copy previously programmed sequences / sub-programs,
• Insert (copy) partial sequences / partial S-P's in other sequences or S-P's that will remain
in both the RAM as well as on the RAM disc.
After selecting the [Hand] operating mode and pressing the [F3] function key the
duplicating menu will be displayed:
]
SERVICE PROGRAM Sequences/S-P copy
Source – SEQUENCE No.
From point-No.
To point-No.
Target - SEQUENCE No.
from point-No.
EXECUTE
F1
F2
F3
: 0 (not available)
:0
:0
: 0 (not available)
:0
SEQUENCE S-P
F4
F5
Copying is always: from the source to the target! Both the source as well as the target can be
either a sequence or sub-program (S-P).
]
If the source or target sequence is a sub-program, place the cursor on the relevant
line and change the selection using the [F5] function key.
]
After entering the source sequence or S-P No. of the data to be copied (from pointNo. to point-No.) and the target sequence or S-P No. as well as the position (from
point-No.), form where the copied data must be inserted, press the [F1] function key
to start the copying process.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-17
VRS 1
Duplicating special functions
Hand-F4-SHF[F3]
Press [SHF] and [F3] function keys to go from the sequences service program menu Copying to RD & RAM to the menu: Copying using special functions
SERVICE PROGRAM Sequences/S-P copy
Insert mode
Source – SEQUENCE No. : 0 (not available)
:0
From point-No.
To point-No.
:0
: 0 (not available)
Target - SEQUENCE No.
From point-No.
:0
EXECUTE
Mode SEQUENCE S-P
F1
F2
F3
F4
F5
Insert mode (default setting)
With this function you can insert a sequence or a section of a program sequence in another
sequence. Sequences / S-P's must not exist. This mode is identical to the "Copying
sequences to RD & RAM".
]
Press the [F3] function key to switch from the insert mode to the overwrite mode:
SERVICE PROGRAM Sequences/S-P copy
Overwrite mode
Source – SEQUENCE No.
: 0 (not available)
From point-No.
:0
To point-No.
:0
Target – SEQUENCE No.
: 0 (not available)
From point-No.
:0
EXECUTE
Mode
SEQUENCE S-P
F1
F2
F3
F4
F5
Overwrite mode
With this function a sequence or a section of a program sequence together with the
additional information can be copied and overwritten into a target sequence. Sequences / SPs must already exist. Sequences/S-Ps will only be overwritten, if the target sequence is at
least the same size. Otherwise a "Wrong parameter" error will be generated.
]
Press the [F3] function key to switch from the overwrite mode to the overwrite coordinates only mode.
SERVICE PROGRAM Sequences/S-P copy
Overwrite co-ordinates only mode
Source – SEQUENCE No.
: 0 (not available)
From point-No.
:0
To point-No.
:0
Target – SEQUENCE No.
: 0 (not available)
From point-No.
:0
EXECUTE
Mode
SEQUENCE S-P
F1
Page:12-18
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Overwrite co-ordinates only mode
With this function the co-ordinates of the target sequence will be overwritten with the coordinates of the source sequence in a sequence or a section of a program sequence. All
other functions of the target sequence remain as before.
]
Press the [F3] function key to switch from the overwrite co-ordinates only mode to the
change co-ordinates mode:
SERVICE PROGRAM Sequences/S-P copy
Change co-ordinates only overwrite mode
Source – SEQUENCE No. : 0 (not available)
:0
From point-No.
To point-No.
:0
: 0 (not available)
Target – SEQUENCE No.
From point-No.
:0
EXECUTE
Mode
SEQUENCE S-P
F1
F2
F3
F4
F5
Change co-ordinates only overwrite mode
In certain cases it is necessary to run an existing sequence in the opposite direction, i.e. the
co-ordinates of the last points will become the co-ordinates of the first points etc.
With this function it is possible to change the co-ordinates in this manner.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-19
VRS 1
Saving / loading / comparing / deleting
The following functions described here can also be carried out with MS-DOS HD formatted
discs, if you are using a CPU 30 Rev 4 in your control system.
The saving, loading, comparing and deleting functions are called up from the service
program [Continue] menu.
This is reached after selecting the [Hand] operating mode via [F4] and [F5] key combination.
The following screen is displayed:
SERVICE PROGRAM Floppy disc
F1 = Save :
VRS1
→ Floppy
F2 = Load :
Floppy
→ VRS1
F3 = Verify :
Floppy
↔ VRS1
F4 = Delete :
from floppy
F5 = Continue
Save
Load
Verify
Delete Continue
F1
F2
F3
F4
F5
Before the functions can be executed, the files must be selected (marked). If the function is
to be executed with all the available files, the function can be executed by previously
pressing the shift key.
Marking
This function is important when individual files are to be saved, loaded or verified.
After a function key in the ‘Floppy disc’ service program has been pressed and depending on
the function selected for the file, it will be assigned to one of the 6 following groups located in
the VRS1 controller or on the disc.
The names of the 6 groups are displayed on the screen in the following order:
n Sequences,
o Sub-program (S-P),
p Constants,
q Macros,
r PLC program,
s Sensor constants.
The first to be displayed is the group of sequences. Now any sequence can be marked.
Page:12-20
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Press the [F5] function key in order to mark a component in the next group. If there are no
existing components in the group, this group will be jumped.
Marking sequences
] The sequences saved in the VRS1 controller or on the disc will be displayed as the
first group. The programmed sequences are displayed on the screen in ascending
order. As a maximum of only 32 sequences can be displayed at the same time, you
can use the cursor keys to scroll to other programmed sequences.
VRS1 → Floppy
Seq.
1< 2
Save
Mark
F1
F2
F3
All
Continue
F4
F5
At this position only the components (constants or programs) that are actually present in the
robot system are displayed on the screen and only these should be marked. If, for example,
no module has been installed on your system, then no text will be displayed behind the
‘Module:‘ point at the relevant position on the screen.
]
The cursor, which is indicated by the ‘<‘ symbol, always uses the head to point to a
group component that can be marked. Use the arrow keys to move the cursor to any
other required component displayed on the screen.
]
Mark the component on which the cursor lies by pressing [F2] or the [Return] keys.
VRS1 → Floppy
Seq.
1* < 2
Save
Mark
F1
F2
F3
All
Continue
F4
F5
If a component has been marked, this is indicated by a ‘*’ star symbol, which is displayed
directly alongside the component.
The marking of sub-programs, PLC macros, PLC programs and the sensor constants are
carried out in an identical manner to the marking of sequences.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-21
VRS 1
Marking of constants
The documentation files and robot system modules also belong to the group of constants.
The group identification (here constants) is displayed in the upper right hand corner of the
screen.
VRS1 → Floppydisc
Constants
Constants
: > * with / without AE-standard.
* Inter-bus
Documentation :
* Gripper
Module
:
* SENSOR *ZTF
* S-PGEN
Save
Mark
All
Continue
F1
F2
F3
F4
F5
The marking of the constants is carried out using the same keys as were used for the
‘sequences’.
]
When all of the required constants, documentation and modules have been marked,
they can be saved, loaded, verified or deleted by pressing the [F1] function key.
]
Should, for example, more of the PLC macros belonging to the constants need to be
marked, press the [F5] key to jump to the PLC macros group in order to mark other
components.
Page:12-22
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Saving
The following screen is displayed after pressing the [F1] function key:
]
Directory
Path : /A:
ROBO_01
ROBO 02
ROBO_03
ROBO 04
OK
F1
<DIR>
<DIR>
<DIR>
<DIR>
FD:/
F2
11.11.98
11.11.98
11.11.98
11.11.98
08:11
08:11
08:11
08:11
->
<-
F3
F4
F5
]
Use the [F3] – [F4] function keys to select if it should be saved in the main directory
or in a sub-directory.
]
The following is displayed after pressing the [F3] function key:
Directory
Path : /A:/ROBO 1
>----------
OK
F1
FD:/
F2
->
<-
F3
F4
F5
]
Press the [F4] function key to jump out of a sub-directory and return to the main
directory.
]
The following screen is displayed after pressing the [F1] function key:
Save individually or all ?
All
with AE
F1
All
Individual without AE
F2
F3
F4
F5
]
All files in the VRS1 controller will be marked with axis standardisation by pressing
the [F1] key again or marked without axis standardisation by pressing the [F3] key.
]
The disc or a network drive will be checked first, and then it will be saved
immediately.
]
Press the [F2] function key to mark and save individual sequences, SPs, macros,
constants, etc.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-23
VRS 1
Note:
Read the "Marking" section in this chapter for more information regarding this.
Loading
]
The following screen is displayed after pressing the [F2] function key:
Directory
Path : /A:
ROBO 01
ROBO_02
ROBO 03
ROBO_04
OK
F1
<DIR>
<DIR>
<DIR>
<DIR>
FD:/
F2
11.11.98
11.11.98
11.11.98
11.11.98
08:11
08:11
08:11
08:11
->
<-
F3
F4
F5
]
Use the [F3] – [F4] function keys to select if it should be saved in the main directory
or in a sub-directory.
]
The following is displayed after pressing the [F3] function key:
MSDOS Floppy Æ VRS1
Path : /A:/ROBO 1
>----------
Directory
OK
<-
F1
FD:/
F2
->
F3
F4
F5
]
Press the [F4] function key to jump out of a sub-directory and return to the main
directory.
]
The following screen is displayed after pressing the [F1] function key:
MSDOS Floppy Æ VRS1
Path : /A:/ROBO 1
Load individually or all ?
All
with AE
F1
]
All
Individual without AE
F2
F3
F4
F5
All files in the VRS1 controller will be marked with axis standardisation by pressing the
[F1] key again or marked without axis standardisation by pressing the [F3] key.
Page:12-24
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
The disc or a network drive will be checked first, and then it will be loaded
immediately.
]
Press the [F2] function key to mark and load individual sequences, SPs, macros,
constants, etc.
]
When a sequence is marked, the system will check to see if the sequence is already
stored in the RAM card. If it is, the following menu will be displayed:
MSDOS Floppy Æ VRS1
Path : /A:/ROBO_1
LIN Test
31.10.01
Path : /R:Rd
LIN Test
31.10.01
Path : /A:/Robo_1
1< 2 3 4 5 6
Load
Mark
F1
F2
F3
Flg
31.10.01
31.10.01
All
Continue
F4
F5
A sequence comparison can then be carried out using the set-up and modification dates that
are now displayed!
Verify and delete operations are identical with the load operation.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-25
VRS 1
Error codes generated when reading in the seq. from FD, RD & RAM
When reading in the sequences and S-P's different plausibility checks can be carried out.
Any possible errors that occur can be acknowledged by pressing the [F1] function key.
The sequences and S-P's displayed as having errors must be corrected and tested without
fail. The displayed error code gives information regarding the error that has occurred.
ERROR
CODES:
Description
1
2
3
4
5
*) 6
7
8
16
32
64
128
Error when reading in the point list file
Incomplete file
Solution: points missing in the sequence/S-P
Checksum error when reading the points
Solution: point information contains errors
Error codes 1 + 2 have been generated
Error when reading the PLC file
Solution:
The relevant point does not
have an PLC instruction
error codes 4 + 1 have occurred
error codes 4 + 2 have occurred
error codes 4 + 3 or 4 + 2 + 1 have occurred
Wrong sequence/S-P No. read in
File error (not opened) - internal error
Main memory is full
Solution: the sequence is incomplete
Checksum error with PLC data
Solution:
The relevant point does not
have an PLC instruction
PLC binary output has errors because of
the version change
Solution:
The binary output cannot
be imported into all points in
the PLC, as not enough
PLC lines are free.
*) If several different errors occur in the sequence, the error number will
be given as the sum. Example: error code 14 = errors 2 + 4 + 8 have
occurred.
Page:12-26
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
General information regarding logbooks
Hand-F4-F5-F5
The controller documents all important system reports, system error events and operator
interventions together with the date and time in an internal logbook. If a breakdown occurs,
for example, reading the information in the logbook can result in a quick and accurate error
analysis.
An entry in the logbook is always made on a logbook page. The logbook has a total of 100
pages, on which the last 100 system reports or operator interventions are always
documented.
The following screen will be displayed after selecting the logbook menus:
]
SERVICE PROGRAM Logbook
F1 = Read logbook
F2 = Save logbook to floppy disc
F3 = Read logbook from floppy disc
F4 = Load new operating system
F5 = Continue
Read
Save Read floppy
F1
F2
F3
Continue
F4
F5
]
Press the [F1] function key in order to read the logbook entry.
]
Press the [F2] function key in order to save the logbook entry to disc.
]
Press the [F3] function key in order to read the saved logbook entry from a disc.
Hand-F4-F5-F5-F1
Reading the logbook
] The following screen will be displayed in order to read the logbook:
VRS1 READ LOGBOOK
No. 0 Date : 10.11.98
Modify the constants
C420
+
F1
Time : 14:20:26
-
F2
Print
F3
F4
F5
The logbook page (No. 0 - 99) together with the date and time when the entry was created is
displayed on the screen. The associated logbook entry can be read in the lower 4 lines.
]
Press the [F1] function key to page forward in the logbook.
]
Press the [F2] function key to page backwards in the logbook.
]
Use the [Esc] key to return to the service program menu.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-27
VRS 1
Hand-F4-F5-F5-F2
Saving the logbook to a floppy disc
Use the "Saving a logbook to a floppy disc“ function in order to save the logbook with the
current entries to a PDOS formatted disc.
]
After selecting the function the conditions for using a formatted disc will be
displayed.
SERVICE PROGRAM Logbook
Please put a formatted disc in the drive . . .
and acknowledge with F1 !
F1
]
F2
F3
F4
F5
Place a formatted disc in the drive and confirm this using the [F1] function key.
SERVICE PROGRAM Logbook
Copying . . . please wait
F1
]
F2
F3
F4
F5
The logbook is now saved on disc.
Page:12-28
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F4-F5-F5-F3
Reading the logbook from a floppy disc
With this function a logbook that has been saved to disc can be displayed on the screen.
Only the logbook from the disc will be displayed. The logbook that is currently in the
controller will not be overwritten.
The following screen is displayed when reading a logbook from a disc:
]
VRS1 READ LOGBOOK from floppy disc
No. 0 Date : 10.11.98
Logbook backup finished !
+
F1
Time : 14:20:26
-
F2
Print
F3
F4
F5
The page (No. 0 - 99) of the logbook saved on the disc will be displayed on the screen
together with the date and time. The associated logbook entry can be read in the lower 4
lines.
]
Press the [F1] function key, to page forward through the logbook saved on the disc.
]
Press the [F2] function key, to page backwards through the logbook saved on the
disc.
]
Press the [Esc] key to return to the service program menu.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-29
VRS 1
Hand-F4-F5-F5-F4
Loading a new operating system using CPU 30 Rev 4
Depending on the CPU being used, the controller operating system permanently stored in
flash-PROM's or EPROM's. If a CPU 30 Rev 4 is in use then flash-PROMs are used. These
can no longer be changed for a version update as before. The update of the operating
system is carried out via the service program using the following menus as described. The
operating system is reloaded into the flash-PROMs from disc or via a network drive.
The operating system discs (min. 2 discs) and a key-disc or a connection to the server are
required for loading a new operating system.
!
Important information
If the controller looses the current sequences and point Nos. when loading a new
operating system, traverse the robot first to point "0" of the current sequence.
Before loading read the "New performance features" information for the operating
system without fail.
You are only permitted to use an original operating system from VOLKSWAGEN AG.
]
The following menu will be displayed after selecting the [Hand] operating mode and
pressing the [F4], [F5] and [F5] function keys:
SERVICE PROGRAM Log book
F1 = Read log book
F2 = Save log book to floppy disc
F3 = Read log book from floppy disc
F4 = Load new operating system
F5 = Continue
]
Read
Save
F1
F2
Read floppy Update
F3
F4
Continue
F5
Select the [F4] function key in order to load a new operating system.
The loading of a new operating system is only possible in conjunction with
a key disc.
]
Place the key disc in the drive and confirm this using the [F1] function key.
]
After the successful checking of the key disc the loading of the operating system
must be confirmed once more.
]
Press the [F1] function key in order to load the new operating system.
]
The process can be aborted by pressing the [Esc] key.
Page:12-30
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
After a short wait the system will report with the following:
]
A T T E N T I O N ! : Loading system files VRS !!!
Continue with F1
Abort with F2
F1
F2
F3
F4
F5
]
Press the [F1] function key in order to load the new operating system or
]
Press the [F2] function key to abort the process.
]
The system will be restarted
]
Afterwards place the operating system disc No.1 in the drive and confirm this by
pressing the [F1] function key.
The disc will now be read in by the system and the current track and page Nos. will be
displayed. After approx. 80 sec. you will be asked to put operating system disc No. 2 in the
drive.
]
Afterwards place the next operating system disc in the drive and confirm this by
pressing the [F1] function key.
At the end of this process, the operating system that up to now has resided in the CPU's
volatile RAM will be written to the flash-PROMs. The duration of this process is approx. 10
minutes.
]
The following screen will be displayed after a successful update.
Program successfully updated !
F1
F2
F3
F4
F5
The system must now boot up just the same as after a ‘RESET’. As a result of the new
operating system the controller will display the following screen once:
2. RAM - error!
07.03.02
Elektroplanung-und Anlagenbau
Page:12-31
VRS 1
]
Acknowledge this report by pressing the [F1] function key. After the report has been
acknowledged the system will be as selected.
Setting the time and date
]
Hand-F4-F5-F5-F4
The following screen is displayed after pressing the function key:
Z
General SERVICE PROGRAM
F1=Reset the time and date
F2=Load & activate the auxiliary module
t
d l l dconfiguration
kti i
F3=Network
F5=Continue
Time
F1
]
Module
W i
Network
F2
F3
Continue
F4
F5
The following screen is displayed after pressing the [F1] function key:
Enter the date and time
Date
Time
Day
F1
=
=
11/11/98
11:55:45
Month
Year
Hour
Minute
F2
F3
F4
F5
]
Now enter the day, month, year, hour and minute by pressing the respective [F1] –
[F5] function key.
]
Close each entry by pressing the [RETURN].
]
The controller will automatically import the date.
]
The entering and processing of a year > 2000 will not cause any problems.
]
The VRS1 controller with an operating system version > 1.13j is Y2K compatible!
Page:12-32
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Updating from Version 1.13 or 1.14 to Version 2.0
Version 2.0 will update the previously installed VMEPROM – operating system to the new
VxWorks – operating system, i.e. the RAM – disc will be converted from PDOS to MSDOS
and the CPU will be converted from VMEPROM to VxWorks. This means that the RAM –
disc has to be reformatted. 4 discs are required for this.
Therefore the following basic points must be implemented:
• All data must be saved to an MS-DOS formatted HD/DD disc before the operating system
is changed
• The robot must be traversed into the REF–position
• The VRS_Vx V.2.x loader must be loaded from disc 1 via the “Load new operating
system” menu.
• The Flash-PROMs will be burnt for approximately 10 min. after the loading has been
completed, i.e. the existing VRS-operating system will be deleted from the RAM.
Memory area
Addr. FFFFFF
Disk 1
Loader
Addr. 080000
Addr. 000000
]
The system will display the following report menu afterwards:
A TTENTION! : VRS - Vx - Works loader
has been loaded!!!
Continue with F1
F1
07.03.02
F2
Abort with F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:12-33
VRS 1
]
The next step is to load Vx_Works Kernel V 1.0 from disc 2. This means that the
existing VMEPROM – operating system will be deleted from the RAM and the new
VxWorks – operating system will be loaded. This process lasts for approximately 2
min.
Memory area
Addr. FFFFFF
Disk 2
VxWorks
Addr. 080000
Addr. 000000
]
The system will display the following report menu afterwards:
A TTENTION! : VRS – system files
are missing!!!
Continue wirh F1
F1
F2
F3
F4
F5
]
The new VRS – operating system 2.0 must now be loaded in the usual way. This
process lasts for approximately 12 min.
]
A report will then be displayed stating
that the RAM-disc will be formatted and
the DEFAULT - constants will be loaded!
Page:12-34
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Loading and activating the auxiliary module
Hand-F4-F5-F5-F5
You have the option to load, save, delete and activate the sensor, transformation, subprograms and robot model modules from this menu.
]
The following menu is displayed after pressing one of the function keys:
Z
General SERVICE PROGRAM
F1=Reset the time and date
F2=Load & activate the auxiliary module
t
d l l dconfiguration
kti i
F3=Network
F5=Continue
Time
F1
]
Module
W i
F2
Network
F3
Continue
F4
F5
Press the [F2] function key to jump to the service program auxiliary module
Auxiliary module – service program
F1=Sensor module
F2=Transformation module
F3=Sub-program – Generation module
F4=Model
Sensor ZTF/TRA
F1
F2
UPGEN
F3
MODEL
F4
F5
Note:
Loading and saving in the constants is no longer possible! Only the modules
available for use are displayed here.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-35
VRS 1
Hand-F4-F5-F5-F5-F2
Loading, saving,
deleting and activating the sensor module:
The necessary instructions and data for the individual interconnecting of a sensor to the
robot controller are set-up separately in the sensor module, which can be loaded into the
controller from a floppy-disc.
This module includes the following components (amongst others):
Module name
Instructions regarding the data traffic between the sensor and the robot controller
Instructions regarding the robot controller
Sensor specific data (constants)
Sensor error reports
]
Press the [F1] function key to load the sensor and the following menu will be
displayed:
Service program – sensor module
F1=Load sensor module from FD to RD
F2=Save sensor module to FD
F3=Delete sensor module from FD / RD
F4=Activate the sensor module
FD->RD RD->FD
F1
]
F2
Delete
Activate
F3
F4
F5
The disc will be tested after first pressing the [F1] function key and the following
menu will be displayed after the acknowledgement has be made by pressing [F1]
again:
>
Page:12-36
/A:/
ISRA_1
/R:/RD/
ISRA_1
Copy
All
F1
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Place the sensor system disc in the drive and press the [F1] function key. The
module will be loaded and the following menu will be displayed:
Copy ...
File:
F1
]
F2
F3
F4
F5
The system displays the following menu after the loading:
>
]
Please wait
ISRA 1.SEN
/A:/
ISRA_1
/R:/RD/
ISRA_1
Copy
All
F1
F2
F3
F4
F5
Press [ESC] to jump back to the input menu
Service program – sensor module
F1=Load sensor module from FD to RD
F2=Save sensor module to FD
F3=Delete sensor module from FD / RD
F4=Activate the sensor module
FD->RD RD->FD
F1
]
F2
Delete
F3
Activate
F4
F5
Press the [F4] function key to activate the loaded module and the following menu
will be displayed:
>
07.03.02
/R:/RD
ISRA_1
Activate
Deactivate
F1
F2
F3
F4
Elektroplanung-und Anlagenbau
F5
Page:12-37
VRS 1
]
Press the [F1] key and the sensor module will now be activated and this menu will
be displayed:
>
/R:/RD
ISRA_1
(**Active**)
Activate
Deactivate
F1
F2
F3
F4
F5
Proceed as follows to save this module to an MS-DOS formatted DD-disc:
]
Press the [F2] function key in the “Sensor module” service program.
]
The following menu will be displayed after testing the disc and the ensuing selecting
of the directory:
>
/R:/RD
ISRA_1
/A:/ROBO_1/
Copy
All
F1
F2
F3
F4
F5
]
Press the [F1] function key and the module will be copied into the selected directory.
!
Important information:
After a ZTF-module has been loaded, the robot system will be restarted and a
RAM – ERROR report, which must be acknowledged, will be displayed.
This procedure is shown only once as an example and also applies to loading, saving,
deleting and activating the transformation, sub-program – generation modules and models.
Page:12-38
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Network configuration
Hand-F4-F5-F5-F5-F3
From Version 2.0 (VxWorks operating system) onwards, it is possible to integrate the VRS –
control system into the network.
A precondition here is that the Ethernet interface for the CPU has to be connected to a local
network, via a transceiver/receiver using 10 Base-T cable. Furthermore, software that
supports a Network File System (NFS) is also required, e.g. ProNFS 1.2.00.
Commissioning
!
]
Important notice
The details listed for the network administrator, with regard to addressing
and naming, must be adhered to without fail for all of the following entries.
Select the service program – network configuration for the commissioning. The
following menu will be displayed:
General SERVICE PROGRAM
F1= Reset the time and date
F2= Load & activate the auxiliary module
F3= Network configuration
F5= continue
Time
Module
W i
F1
]
F2
Network
F3
Continue
F4
F5
The robot must be configured first. Press the [F3] key and the following menu will be
displayed:
Network configuration 1
F1=IP-address
F2= Sub-net mask
F3=Computer name
F4=Gateway
F5=Continue
07.03.02
:
:
:
:
IP-addr.
Mask
Name
F1
F2
F3
192. 1. 1.214
255.255.255. 0
VRS1 AB
0. 0. 0. 0
Gateway Continue
F4
F5
Elektroplanung-und Anlagenbau
Page:12-39
VRS 1
The function keys have the following functions:
[F1] = IP-address
The IP-address clearly indicates the robot, i.e. 192.1.1.214 .
•
•
•
[F2] = Sub-net mask
A sub-net address can be entered here, if required.
[F3] = Computer name
Enter the computer name here, i.e. VRS1 AB
(Pay attention to upper and lower case letters!)
[F4] = Gateway
Enter the Gateway-address here
]
Press [F5] to display the following menu:
HOST configuration
>
]
HOST
NEW
1
Edit
Delete
F1
F2
()
Continue
F3
F4
F5
Press the [F1] = Edit function key and the HOST (computer) can now be
configured. The following menu will be displayed:
Network configuration 2
F1=User – ID
F2=Group – ID
F3=HOST - Name
F4=HOST – IP – ADDR.
F5=Continue
IP-addr.
F1
Page:12-40
:
:
:
:
Mask
Name
F2
F3
2001
100
Robot laboratory
192. 1. 1. 200
Gateway Continue
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The function keys have the following functions:
• [F1] = User-ID
The User-ID is used to clearly identify the user in the network. Enter your user-ID here,
e.g. 2001.
[F2] = Group-ID
The user is assigned to a specific group together with specific access rights by
the group-ID, e.g. “Read only” access. Enter the group-ID here, i.e. 100
•
•
[F3] = HOST name
The HOST-Name means the name of the computer with which you will be
communicating. Enter the computer name here. (Pay attention to upper and lower case
letters!)
[F4] = HOST IP-ADR
The HOST computer is only reachable at a specific address. Enter the relevant IPaddress here.
!
]
Important information:
The HOST computer must be an NFS-server!
Special software is required for this. More detailed information can be found
in PP-V401 Electrical and system construction drawings.
Press [F5] to display the following menu:
Network configuration 3
Network status:
disabled
F1= Connect
F5=Continue
Connect
F1
]
Continue
F2
F3
F4
F5
Press the [F1] function key and the network status will change from “disabled” to
“enabled”, i.e. the robot is enabled for the network.
The controller will report with a one-time display of the following menu after exiting the menu:
1. Network configuration changed!
2. Update with F1; Abort with F2!
]
Press the [F2] function key and the edited configuration will be saved in the CPU
RAM
07.03.02
Elektroplanung-und Anlagenbau
Page:12-41
VRS 1
The system boot up just as if ‘RESET’ has been pressed. After it has run up, you can
execute the service program either from the server or from a floppy.
Loading and saving a network
configuration
]
Hand-F4-F5-F5-F5-F3-F5-F5
Press one of the above mentioned function keys and the following menu will be
displayed:
Network floppy service
F3=Load from disc
F4=Save to disc
F5=Continue
Connect
F1
F2
LOAD
SAVE
Continue
F3
F4
F5
]
Press the [F1] = Connect function key and an attempt will be made to set-up a
connection between the HOST – computer.
]
Press [F3] to load a previously generated network configuration
]
Press [F4] to save a network configuration to disc
Modifying a network configuration
] If the Client or the HOST addresses were modified and you exit the service program
menu later on, the following menu is displayed:
Network configuration has been changed
Update the BattRAM with F1
Update the RD with F2
F1
F2
F3
F4
F5
]
Press [F1] to up-date the CPU configuration in the RAM. The system must now run
up just as if ‘RESET’ was pressed and a RAM error report will be displayed.
]
Press [F2] to save the modifications to the RAM – card
Page:12-42
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Deleting Multi-Point files from the RAM – disc
]
Hand-F4
Press the [F3] function key in the input menu to display the following menu:
SERVICE PROGRAM - Floppy
F4=delete MP-files from RD
F5=continue
F1
]
F2
F3
Delete
Contiue
F4
F5
Press the [F4] function key to delete the Multipoint-files from the RAM disc
Please read the “Multipoint-geometry” section in Chapter 7 “Programming the
sequences” regarding this.
07.03.02
Elektroplanung-und Anlagenbau
Page:12-43
VRS 1
Page:12-44
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
13. Tests
13. Tests ................................................................................................... 13-1
Function tests .............................................................................................. 13-3
Testing the system inputs and outputs ..................................................... 13-4
Testing the PLC inputs and outputs .......................................................... 13-7
Testing the PLC outputs ............................................................................. 13-7
Displaying the PLC inputs .......................................................................... 13-9
Testing the joystick functions .................................................................... 13-9
Testing the robot axes .............................................................................. 13-11
Standardising the angle encoder (zero adjustment) .............................. 13-13
Standardising the angle encoder using adjustment offsets.................. 13-14
Standardising the axis using adjustment offsets ................................... 13-15
Reference position: automatic traversing ............................................... 13-16
Testing the digital / analog channels ....................................................... 13-18
07.03.02
Elektroplanung-und Anlagenbau
Page:13-1
VRS 1
Page:13-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Function tests
Hand-F3
The tests cover the function checks of the following peripheral components and function
groups:
• System inputs and outputs,
• PLC inputs and outputs,
• Hand console keys,
• Joystick functions,
• Axes traversing directions,
• D/A channels.
]
The following screen will be displayed after the [Hand] operating mode has been
selected and the [F3] function key has been pressed:
Tests
Please select:
Inputs / outputs
System
User
F1
]
F2
Joystick
Keys
F3
Axes
F4
D/A chan.
F5
The required function group can be selected by pressing the relevant [F1] - [F5]
function key.
07.03.02
Elektroplanung-und Anlagenbau
Page:13-3
VRS 1
Testing the system inputs and outputs
]
Hand-F3-F1
The following screen will be displayed after the [Sequence]
operating mode and the [F3] and [F1] function keys have been pressed:
System input / output tests
== >
K6
K7
K8
K9
K23
Wait relay 1
Wait relay 2
Single Step
Automatic
Hand
Off
Off
Off
Off
On
On/off
Continue
F1
F2
F3
F4
F5
]
The function relay to be tested is selected by pressing [Cursor UP] or the [Cursor
DOWN] keys. The screen pointer is then positioned alongside the relay output to be
tested.
]
The ON or OFF switching functions can be tested by repeatedly pressing the [F5]
function key.
The switching status of the relays is displayed on the screen and can be checked at the
same time by monitoring the relevant LEDs on the SLK board.
When you exit the test function, the original switching status will be reset.
]
Other function relays can be tested after pressing the [F1] function key.
System input tests (display only)
KMFS Sequence start
KWE2 Protection grill not linked out
K2
Safety circuit
K1 /K1b / KC1 Drive system
On
(E2)
On
Off
Continue
F1
]
F2
F3
F4
F5
If a VRS1C controller is being used the following will be displayed:
VRS1C system input/output tests
K40
K5
Drive system
Free running
Off
Off
On/off
Continue
F1
Page:13-4
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
K40 Drive system:
The drive system is switched ON or OFF via relay K40. As the
protection circuit is not operating during this test for safety reasons,
only the functionality of relay K40 can be checked.
K5 Free running:
With older controllers this was used for free running (it links out the
safety circuit) of the robot in the [Hand] operating mode. This relay is
no longer fitted with a VRS1C controller.
Press the [F1] function key in order to display other system inputs.
VRS1:
VRS1C:
System input tests (display only)
Hand console ON/OFF keys test
KK50/KK50b
Protection grill
K46
Amplifier & transformer
Process speed for Single-Step
Off
Off
Continue
Continue
F1
Drive system ON key
Drive system OFF key
On
O.K.
Off
F2
Drive sys. ON
F3
F4
F5
F1
F2
F3
F4
F5
Press both drive system ON keys and the display will change from off to on.
Drive sys. OFF The drive system OFF key has the opposite effect. This means, that when
the drive system OFF key is pressed, the display changes from on to off.
]
Press the [F1] function key in order to display other system inputs (VRS1C).
However, only the current statuses will be displayed. A further test via the PHG key
is not possible.
Test system inputs (display only)
KMFS Start sequence
On
KWE2 Protection latice not linked out (E2)
K2
Safety circuit
On
K1 / K1b / KC1 Drive systems
Off
Continue
F1
Sequence start
F2
F3
F4
F5
Test the sequence start signal here, which, for example, can be
generated by a master controller.
Protection lattice If available, the status of the "Linking out the protection circuit" locks will
be displayed.
07.03.02
Elektroplanung-und Anlagenbau
Page:13-5
VRS 1
Safety circuit:
All of the robot machine safety monitoring functions (motor temperature,
brake potentials or additional crash sensors) will be grouped together in the
K2 safety circuit.
Drive system:
You are not permitted to switch the drive system on here due to the opened
safety circuit.
]
Press the [F1] function key in order to display other system inputs. (For VRS1C
only):
Test system inputs (display only)
KK50/KK50b
Protection lattice
K46
Amplifier & transformer
Process velocity for Single-Step
On
O.K.
Off
Continue
F1
F2
F3
F4
F5
Protection lattice
Both the K1a and K1b safety circuits are grouped together under the
K1 safety circuit. This circuit must always be switched off.
K46 servo loop
With this input you can check the operational readiness of all servo
amplifiers.
Process velocity
If present, the status of the "Single Step process velocity" connection
will be displayed here.
]
Press the [F1] function key to display other system inputs.
Test system inputs (display only)
EMT Signal A0
EMT Signal A1
Ramp brake
Hand console acknowledgement
Off
Off
Off
Off
Continue
F1
F2
F3
F4
F5
EMT A0/A1
Provided for an optional adjustment device.
Ramp brakes
Display for system input 15. This is a jumper on the SLK board for
VRS1C system.
Hand console
The ‘Hand console acknowledgement’ signal will be displayed
acknowledgement here, which, for example, can be generated by a master
controller.
]
Press the [F1] function key in order to return to the main menu.
Page:13-6
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Testing the PLC inputs and outputs
Hand-F3-F2
Inputs and outputs are required in order to send commands and signals from the controller to
the process and vice versa, e.g. gripper OPEN/CLOSED, profile free, process end, lock the
robot etc. The fault free functioning of these inputs and outputs can be tested in this function.
]
The following screen will be displayed after selecting the [Sequence] operating
mode and pressing the [F3] and [F2] function keys:
Test
User Sequence 1
Start
On
Number of I/O modules : 1
32 inputs
F1
/
F2
32 outputs
F3
Test
outputs
Display
inputs
F4
F5
The following will be displayed:
• The current sequence selection assignment
• The status of the ON/OFF sequence start signals
• Number of I/O boards found in the system
• The inputs and outputs available for use
]
Pressing the [F4] function key will test the outputs.
]
Pressing the [F5] function key will display the inputs.
Hand-F3-F2-F4
Testing the PLC outputs
] The following will be displayed after pressing the [F4] function key:
Test
User
Outputs
Please enter the output number: 1
A1
A5 A9
A13 A17 A21 A25 A29
0000 0000 0000 0000 0000 0000 0000 0000
all
cyclic
On
Off
No.+
No.On/Off
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:13-7
VRS 1
]
Enter the output-No. to be tested.
]
Acknowledge the entry using the [Return] key.
The selected output No. will be displayed.
]
Press the [F1] function key in order to set an output to ON.
]
Press the [F2] function key in order to set an output to OFF.
]
The currently displayed output No. can be increased or decreased by 1 by pressing
the respective [F3] or [F4] function keys and it can also be tested now.
]
All installed application outputs can be cycled between ON and OFF for test
purposes by pressing the [F5] function key.
Attention! Danger of injuries!
When the outputs are cyclically tested, all connected tools or devices will be also
be moved. Ensure that you remain outside the robot and peripheral device danger
zones.
Page:13-8
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F3-F2-F5
Displaying the PLC inputs
] The following screen will be displayed after selecting the [Sequence] operating
mode and pressing the [F3], [F2] and [F5] function keys:
E1
1001
E33
1000
E65
1000
E97
1001
E5
0100
E37
1001
E69
1001
E101
0000
E9
0000
E41
0100
E73
0100
E105
0000
F1
E13
0000
E45
0000
E77
0000
E109
0000
F2
E17
0000
E49
0000
E81
0000
E113
0000
E21
0000
E53
0000
E85
0000
E117
0000
F3
E25
0000
E57
0000
E89
0000
E121
0000
F4
E29
0000
E61
0000
E93
0000
E125
0000
F5
1 = Input has been set
0 = Input has not been set.
The switching statuses for inputs 1 - 128 are displayed. In the above example I1, I5, I8 and
I10 have been set.
Testing the joystick functions
]
Hand-F3-F3
The following screen will be displayed after selecting the [Hand] operating mode
and pressing the [F3] and [F3] function keys:
Test the joystick keys
A
x
y
z
=- 2
= 1
= 0
Please press the hand console keys :
Joystick selected?
Yes
Const.: 215
F1
F2
F3
F4
F5
The default joystick settings will be displayed together with the X, Y and Z values and the
condition for pressing the respective hand console key (A here).
When you have pressed the hand console key, the abbreviated name of the respective key
will be displayed behind the joystick offsets. If this name is not displayed, the key is
defective.
If the key is pressed continually, up to 5 screens can be displayed one beneath the other at
the same time.
!
Bear in mind, that if the [Esc] key is pressed during testing, you will exit this test
function and the main menu will be displayed again.
07.03.02
Elektroplanung-und Anlagenbau
Page:13-9
VRS 1
+Y
-X
+Z
If the joystick is moved, the screen will change in
accordance with the offsetting.
-Z
+X
-Y
Basic setting
max. +value
max. -value
Page:13-10
X direction Y direction
000
000
+128
+128
- 128
- 128
Z direction
000
+128
- 128
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Testing the robot axes
Hand-F3-F4
The exact mechanical movement of each robot axis as well as the functioning of the
associated measuring systems (angle coding or resolver) will be tested.
]
The following screen will be displayed after selecting the [Sequence] operating
mode and pressing the [F3] and [F4] function keys:
Test
axis
1 ***
AE type : 4096 revs
Tracks:
0000 0000 0111 0010 0111 0010
Decimal:
26940
Angle:
6.62 Degrees
Hexadecimal standardisation :
936
Current AE-value
:
7272
Please enter position variable:
AE standOffset
ardisation
teach-in Ref pos.
F1
F2
F3
F4
F5
Axis-No.
Th axis to be tested is selected and displayed by pressing the [Axis traversing] key (1V/R 12V/R).
Standardised status
Axis has not been standardised -> ***
AE-type
The resolution of the angle encoder per revolution will be displayed for the relevant selected
axis.
Tracks
The angle encoder displayed in this example for axis 1 has a resolution of 24 bits. These bits
are displayed here and are a binary display of the current angle encoder status.
Decimal
The difference between the current angle encoder status and the standardised value is
converted into a decimal number and displayed together with a mathematical sign. This
value must = "0" in the basic axis position (marking position).
Angle
The axis angle is converted here, and the current AE position is given as a rotation in
degrees.
Standardisation value
This value is displayed in hexadecimal and corresponds to the basic angle encoder settings
in the marking position. This value is saved in the system by the standardisation.
07.03.02
Elektroplanung-und Anlagenbau
Page:13-11
VRS 1
Current AE value
This value is display in hexadecimal and corresponds to the current angle encoder status.
Positioning variable
In order to test the selected axis, this must be moved by the position variable entry. The
positioning variable is entered as a number of bits, which correspond to a specific traversing
velocity (default = 0).
Input:
max. = 400 bit = approx. 10 % of the maximum traversing velocity
]
After the positioning variable has been entered and has been confirmed by pressing
the [Return] key, this value will be imported by the controller and displayed on the
screen.
Traverse the selected axis by pressing the hand console keys (1V - 12V/1R - 12R), after the
drive system has been switched on.
Attention! Danger of injuries!
Important monitoring functions for the selected axis are shutdown by pressing the
[Axis traverse] keys (1V-12V / 1R-12R). If an error occurs during the traversing,
dangerous movements of this axis can occur.
The following monitoring functions are switched off during traversing (test) of the selected
axis:
• Lag error monitoring
• Band width monitoring
• Monitoring of the software limits (AE-min. and AE-max.)
• Position control
When the axis is being traversed the values displayed on the screen will be continually
updated.
]
After the selected axis has been tested, switch the drive system off again.
F5 = A7 - A12 The switching over from axes 1 - 6 to 7 - 12 and vice versa for systems having
more than 6 axes is made here using the [Axis traversing] keys.
Page:13-12
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F3-F4-F1
Standardising the angle encoder (zero adjustment)
As a result of the standardisation the current position of the angle encoder or the resolver
setting of the selected axis will be imported into the controller as the new basic settings.
A good example would be after repairs have been made to an position control axis when the
axis must be traversed into the basic mechanical position (marking position). It is possible
that the position control must be assigned a different null position. The standardisation
undertakes this function!
The standardisation of the axes should be carried out in an ascending order.
(Axes 1,2,3,4,5,6; additional axes: 7,8,...).
!
Important information
Due to their mechanical couplings the manual axes must be standardised in the order
4, 5, 6. Any other order will result in a standardisation error!
]
After the axis that is to be standardised has been brought to its basic mechanical
position with the help of the dial gauge, press the [F1] function key. The
acknowledgement conditions via the function keys will be displayed in the menu.
Test
axis
1 ***
AE type : 4096 revs
Tracks:
0000 0000 0111 0010 0111 0010
Decimal:
26940
Angle:
6.62 degrees
Hexadecimal standardisation :
936
Current AE-value
:
7272
Please enter the position variable :
STANDARDISE AXIS WITHOUT OFFSET
Yes
No
EMT
F1
F2
F3
F4
F5
If NO is entered, no standardisation will be carried out, the acknowledgement conditions will
be cleared from the screen.
For safety reasons the [Shf] + [F2] key combination must be pressed for YES. Then the
current AE value will first be imported for the selected axis and the angle set to "0".
If an angle offset has been entered for axis 4, then offset angles for axes 5 and 6 and
generated via the axis coupling. These belong to the robot's constant sets and enable a
quick and precise standardisation. The calculated offset angle for axes 5 and 6 can include
+/- 1° depending on the type of robot.
07.03.02
Elektroplanung-und Anlagenbau
Page:13-13
VRS 1
Hand-F3-F4-F3
Standardising the angle encoder using adjustment offsets
Because of the inherent elasticity of the robot mechanics (especially the drive elasticity) there
exists a problem, where the exact reproduction of the zero adjustment can only be achieved
under the same conditions (especially axis positioning and mechanical loading). Therefore
the zero adjustment should always be carried out without mechanical loading and with all
axes in the basic position.
In practise this can result in problems if there is an adjustment loss or also when checking
the correct zero position, the tool must be removed from the robot head or the zero position
for all axes will not be taken up at the same time.
For this reason there is the option in the controller to teach each axis with up to 7 adjustable
offsets at the end of a correct robot standardisation.
]
Position the axis to be standardised in its basic mechanical position with the help of
the dial gauge.
]
Press the [F3] function key.
The following menu will be displayed:
ADJUSTMENT OFFSET TEACH-IN AXIS 1
TL No.1 = 0
TL No.2 = 0
TL No.3 = 0
TL No.4 = 0
Please enter TL No. for
TL No.5 = 0
the adjustment offset: 0
TL No.6 = 0
TL No.7 = 0
F1
F2
F3
F4
F5
]
Enter the tool number, under which this adjustment offset will be stored.
]
Confirm the entry by pressing the [Return] key.
!
Important information
Offset teaching does not modify the zero adjustment. It is simply the difference
value for the existing zero position that is determined and saved under the entered
tool No.
The adjustment offsets in the constant can also be edited manually.
Page:13-14
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F3-F4
Standardising the axis using adjustment offsets
The standardising of the axes is carried out in the [Sequence] operating mode.
]
Select the [Hand] operating mode.
]
Press the [F3] function key.
]
Press the [F4] function key.
]
Position the axis to be standardised in its basic mechanical position with the help of
the dial gauge.
]
Use the [F1] function key to initiate the standardisation.
The following menu will be displayed only when an adjustment offset exists for the relevant
axis:
ADJUSTMENT OFFSET TEACH-IN AXIS 1
TL No.1 = 3572
TL No.2 = 0
TL No.3 = 0
TL No.4 = 0
Please enter the TL No. for
TL No.5 = 0
the adjustment offset : 0
TL No.6 = 0
TL No.7 = 0
F1
F2
F3
F4
F5
]
Enter the tool number for the adjustment offset. (Entering "0" -> standardising
without offsets)
]
Confirm the entry by pressing the [Return] key.
The following menu will be displayed with the acknowledgement conditions for standardising
the axis with the adjustment offsets:
Test
axis
1
AE type : 4096 revs
Tracks:
1011 0111 1000 1111 1011 0101
Decimal:
30842
Angle:
20.5 degrees
Hexadecimal standardisation :
B708BC
Current AE-value
:
B78FB5
Please enter position variable:
AXIS STANDARDISED WITHOUT OFFSET 3572
Yes
No
EMT
F1
F2
F3
F4
F5
If NO is entered, no standardisation will be carried out, the acknowledgement conditions will
be cleared from the screen.
For safety reasons the [SHF] + [F2] key combination must be pressed for YES. This will set
the AE value of the angle offsets for the selected axis first.
07.03.02
Elektroplanung-und Anlagenbau
Page:13-15
VRS 1
Reference position: automatic traversing
Hand-F3-F4
The position of each robot axis will be indicated by the reference position, in which the basic
mechanical position (marking position) and the basic electrical position (AE = 0) are
matched.
In order to check already standardised axes, the axes to be tested can be traversed semiautomatically to this position.
Attention! Danger of collisions!
The robot traverses when the axis traverse key is pressed in the basic electrical
position (AE=0). The current position as well as the mechanical alignment of other
axes will not be taken into consideration. The robot, tool, tool piece or other device
can be damaged or destroyed by a collision. Select a smaller position variable
(e.g. 50) and pay special attention to the possibility of collisions.
]
After selecting the [Hand] operating mode and pressing the [F3] and [F4] function
keys the following screen will be displayed:
Test
axis
1
AE type : 4096 revs
Tracks:
1011 0111 1000 1111 1011 0101
Decimal:
30842
Angle:
20.5 degrees
Hexadecimal standardisation :
B708BC
Current AE-value
:
B78FB5
Please enter position variable:
AE standOffset
ardisation
teach-in Ref pos.
F1
F2
F3
F4
F5
]
Press the [F4] function key and it will automatically traverse to the basic position of
each selected axis that is displayed. Apart from the addition of 'active', a pre-entered
position variable of 400 bits will be displayed on the screen at the same time.
]
Press the [F4] function key once again to switch the function off again.
!
Important information!
The mechanical alignment of the manual axes is not taken into account here. In
order to check the exact start position of the manual axes, all three manual axes,
starting from axis 4, must be traversed one after the other into the reference
position.
Page:13-16
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The axis to be tested does not require extra pre-selection, as the display on the screen as
well as the execution of the function, each of the pressed [Axis traversing] keys (1V/1R 12V/12R), will be immediately updated. This axis will move after the drive system is switched
on, provided that the axis traversing key is pressed or held down.
Attention! Danger of injuries!
Important monitoring functions for the selected axis are shutdown by pressing the
[Axis traversing] keys (1V-12V / 1R-12R). If an error occurs during the traversing,
the movements of this axis can be dangerous. The axis should only be traversed
its basic position, when you and other personnel are outside the danger zone.
The following monitoring functions are set in operation when traversing the selected axis:
• Lag error monitoring
• Band width monitoring
• Monitoring of the software limits (AE-min. and AE-max.)
• Position control
Regardless of the R/V traversing key being pressed, the axis will always traverse in the basic
AE=0 position (decimal AE-value = 0 = basic electrical setting reached).
Test
axis
1
AE type : 4096 revs
Tracks:
1011 0111 1000 1111 1011 0101
Decimal:
30842
Angle:
20.5 degrees
Hexadecimal standardisation :
B708BC
Current AE-value
:
B78FB5
Please enter tposition variable
:
AE standOffset
ardisation
teach-in Ref pos.
F1
F2
F3
F4
F5
After reaching the electrical basic position (AE = 0) no further movement of this axis is
possible.
Error situations:
AE = 0; mechanical marking position has not been reached
In this case traverse to the correct marking position and re-standardise the tool again.
Read the "Angle encoder standardisation (zero adjustment)" section in this chapter.
AE does not equal 0
The offset compensation for the respective axis amplifier must be checked here.
07.03.02
Elektroplanung-und Anlagenbau
Page:13-17
VRS 1
Testing the digital / analog channels
Hand-F3-F5
A DC voltage of up to +/- 10.24V is outputted via the D/A channels. Entering a decimal value
can test all the channel functions simultaneously here. This value is converted into an analog
voltage, which can be measured on the I/O board.
2 D/A modules can be plugged into each I/O board. Each D/A module has 2 channels
available for use if the optional board has been fitted.
The voltage level is a linear function of the entered bits.
1 bit = 2.5 mV
- 10.24V
- 5.12V
- 4095 Bit - 2048 Bit
]
+4095 Bit = +10.24 V
-4095 Bit = -10.24 V
0V
+ 5.12V
+ 10.24V
0 Bit
+ 2048 Bit + 4095 Bit
The following screen will be displayed after selecting the [Hand] operating mode
and pressing the [F3] and [F5] function keys:
Test
D/A channels
Test value:
0
Enter:
F1
F2
F3
F4
F5
]
Enter the voltage value in bits.
]
Confirm the entry by pressing the [Return] key. The entered value will be used as
the test value and displayed on the screen.
]
The same voltage must be measured on all installed channels. Otherwise the
respective channel is defective and the board must be changed.
A description of the D/A outputs can be found in chapter 14 "Modifying the
constants".
Page:13-18
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
14. Modifying the constants
14. Modifying the constants ................................................................... 14-1
Constants..................................................................................................... 14-5
Modifying the constants ............................................................................. 14-5
Key disc........................................................................................................ 14-6
100 - 199 Servo constants .......................................................................... 14-8
100 P-control amplification factor............................................................. 14-9
101 Velocity pre-control............................................................................ 14-10
102 The maximum position error ............................................................. 14-12
103 Maximum bandwidth .......................................................................... 14-13
104 Vmax voltage ...................................................................................... 14-14
105 Acceleration pre-control .................................................................... 14-15
106 - 111 Servo parameters (VRS1C)....................................................... 14-17
106 Amplification (P-content)................................................................... 14-18
107 Time constant (I-content)................................................................... 14-19
108 Peak current reduction (PI-limit) ....................................................... 14-21
109 Nominal current monitoring (I2T) ...................................................... 14-22
110 Inverting the servo set value ............................................................. 14-23
111 Inverting the positioning set value ................................................... 14-24
120 Integral content of the positioning control ...................................... 14-25
130 Editing the incremental step widths ................................................. 14-26
200 - 299 Manipulator constants .............................................................. 14-27
200 Manipulator type................................................................................. 14-28
201 Number of additional axes................................................................. 14-30
202 Maximum axis velocity (bit/5 ms)...................................................... 14-31
203 - 230 Robot data ................................................................................. 14-32
203 Axis geometry..................................................................................... 14-33
204 AE basic settings ............................................................................... 14-35
205 AE lower limit (lower software limit) ................................................. 14-36
Automatic setting of the AE lower limit................................................... 14-37
206 AE upper limit (upper software limit)................................................ 14-38
Automatic setting of the AE upper limit .................................................. 14-39
207 AE resolution (bit/90 degrees)........................................................... 14-39
208 Maximum axis acceleration (degs/sec2) ........................................... 14-40
Axis acceleration in Hand mode .............................................................. 14-41
209 Angle encoder rotational speed........................................................ 14-42
210 Operating system version ................................................................. 14-43
211 ACTUATORS OFF time ...................................................................... 14-44
212 Maximum axis velocity in Hand mode in %...................................... 14-45
213 Running in Automatic mode.............................................................. 14-46
214 Filter functions ................................................................................... 14-47
Trajectory filter .......................................................................................... 14-48
Axis filter .................................................................................................... 14-49
215 Joystick - selection ............................................................................ 14-50
216 System and station editing................................................................ 14-50
The text editor............................................................................................ 14-51
220 Angle offsets (degrees) ...................................................................... 14-51
07.03.02
Elektroplanung-und Anlagenbau
Page:14-1
VRS 1
221 Axis coupling factors ......................................................................... 14-52
222 Automatic adjustment velocity (bit/5 ms)......................................... 14-53
223 EMT - Offset ........................................................................................ 14-54
224 Adjustment offsets ............................................................................. 14-55
230 Editing AE values ............................................................................... 14-57
231 Accelerating factors and braking factors for stopping ................... 14-58
300 - 349 Input / output constants ........................................................... 14-60
300 Allocating gripper............................................................................... 14-60
Gripper type allocation ............................................................................. 14-62
The gripper text editor .............................................................................. 14-64
301 Output attributes ................................................................................ 14-69
Condition.................................................................................................... 14-70
Dependencies ............................................................................................ 14-70
Compatibility.............................................................................................. 14-70
302 Defining static flags ........................................................................... 14-70
303 Selective setting/clearing of flags (editing)...................................... 14-71
304 Entering the binary output format..................................................... 14-72
305 Defining the static outputs ................................................................ 14-74
306 Displaying a point number on a counter .......................................... 14-75
307 Displaying a velocity on a counter.................................................... 14-75
310 ... 319 SYSTEM I / O .......................................................................... 14-76
310 Sequence selection (binary/1 from n)............................................... 14-77
311 Number of PLC-inputs ....................................................................... 14-84
312 Number of PLC-outputs ..................................................................... 14-85
313 Inter-bus outputs ................................................................................ 14-86
314 Inter-bus inputs .................................................................................. 14-87
315 SYS I/O displayed with FLAGS.......................................................... 14-89
320 Assigning the analog output channels............................................. 14-92
321 Attributes for analog outputs ............................................................ 14-95
330 PLC-macros ........................................................................................ 14-95
340 Setting the PLC-counters (arithm.) ................................................... 14-98
350 - 354 Interbus master menu ............................................................. 14-100
General information ................................................................................ 14-100
Installation information:.......................................................................... 14-100
Preconditions: ......................................................................................... 14-101
Entering / Displaying of “Hexadecimal numbers”:............................... 14-101
350 Executing interbus operations ........................................................ 14-102
351 Setting-up and editing the interbus ................................................ 14-103
Editing the IBM CFG................................................................................ 14-104
IBM process data reference list ............................................................. 14-105
IBM Process data description list .......................................................... 14-106
Interbus – docking function: .................................................................. 14-107
352 Setting-up the interbus slave .......................................................... 14-109
353 Editing the interbus module names................................................ 14-110
354 Interbus configuration ..................................................................... 14-111
Activating / deactivating the master ...................................................... 14-112
Reading out the IBM configuration ........................................................ 14-112
IBM automatic configuration .................................................................. 14-112
Page: 14-2
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Configuring using the control system................................................... 14-113
Changing the output bytes using the control system.......................... 14-114
400 - 419 Tool constants......................................................................... 14-116
400 Setting the tool for teaching............................................................ 14-117
401 Tool measuring (TCP) ...................................................................... 14-117
Tool measuring (TCP external) .............................................................. 14-119
Automatic tool measuring ...................................................................... 14-120
Automatic TCP-measuring ..................................................................... 14-121
Procedure: ............................................................................................... 14-121
Teaching the reference sequence.......................................................... 14-123
Automatic calculation of the TCP .......................................................... 14-123
TCP automatic measuring (using reference tool)................................. 14-124
Teaching the reference sequence.......................................................... 14-125
Automatic calculation of the TCP .......................................................... 14-126
Automatic determination of the tool orientation (RPY-angle) ............. 14-127
Teaching a reference sequence ............................................................. 14-128
Automatic calculation of the tool orientation ....................................... 14-128
402 Tool loading data.............................................................................. 14-130
403 Calibration plate position for tool-piece determination ................ 14-131
Teaching a calibration plate positioning sequence: ............................ 14-133
420 - 439 Sensor constants .................................................................... 14-134
420 Switching on and off sensor functions .......................................... 14-134
421 Loading the sensor module............................................................. 14-135
422 Sensor module constants................................................................ 14-136
460 - 479 Trajectory module constants ................................................. 14-139
460 Alternate inverse transformation (AIT) ........................................... 14-139
461 Additional axes transformation (AATF).......................................... 14-140
462 AATF constants................................................................................ 14-142
463 Transformation module ................................................................... 14-142
464 Kinematics in the [Hand] operating mode...................................... 14-143
465 Loading the S-P- module ................................................................. 14-144
466 Accuracy ball parameters................................................................ 14-145
Radius matching ..................................................................................... 14-145
467 Loading the robot model ................................................................. 14-146
468 Velocity profile selection ................................................................. 14-146
480 Hand console (teach box) language ............................................... 14-147
490 The free running PLC ....................................................................... 14-149
500 PLC-Operands .................................................................................. 14-150
555 Setting the system clock time ......................................................... 14-151
Stopping the load conditions ................................................................. 14-151
556 Setting the PLC - load ...................................................................... 14-152
07.03.02
Elektroplanung-und Anlagenbau
Page:14-3
VRS 1
Page: 14-4
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Constants
The name constant covers all robot and controller parameters in the controller.
This includes:
• Control characteristics
• Robot mechanics
• Input and output hardware
• Tools
• Auxiliary modules for loading
• Programming the free running PLC
If a segment of the constants are only changed occasionally or never at all (e.g. the
robot mechanics) the major part of the constant can be used to optimise the system to
an installed application.
The constants are permanently saved in the system and automatically initialised with
each system start. For backup purposes the data can be saved to a constants disc or
printed out via a printer connected to the system.
Read the "Printing the robot constants" section in chapter 12 "Service
programs" for more information regarding this.
Modifying the constants
Hand-F2
The modifying of the constants is normally carried out in two steps:
1. Select the required constant type
2. Enter the modified values
Certain constants are protected against unauthorised or accidental modifications. The
additional request to put the key disc in the drive will be displayed on the screen.
]
The following screen will be displayed after selecting the [Hand] operating
mode and pressing the [F2] function key:
CONSTANTS
F1 = Servo constant
F2 = Manipulator constants
F3 = On/off constants
F4 = Tools constants
F5 = Continue
Input:
F1
07.03.02
F2
F3
100
200
300
400
F4
- 199
- 299
- 399
- 419
F5
Elektroplanung-und Anlagenbau
Page:14-5
VRS 1
The selection of the constants is carried out by:
1. Pressing the relevant function key or
2. Entering the specific constant number via the hand console decimal key board.
]
Press the [F5] function key in order to display other constants:
CONSTANTS
F1 = Sensor constants
F2 = Trajectory module constants
F3 = Teach box language
F4 = Free running (asynchr.) PLC
F5 = PLC operands
Input:
F1
F2
F3
F4
420 - 439
460 - 479
480
490
500
F5
Key disc
The key disc is used to protect the system constants from unauthorised or
accidental modifications (e.g. robot data, tool data, system specific
constants etc.).
This is used in a similar way to a cheque card; to check the access
authorisation before the protected system data (constants) can be
modified.
Apart from a special security file the key disc also contains the operating system
version No., a directory of all valid robot types as well as type specific constants, tool
constants and system constants.
The disc drive is a standard computer fitting.
When, in exceptional cases, it is necessary to modify the protected data only
qualified personnel are permitted to carry this out! Authorised personnel can
order another copy of the key disc for this from PP-V405 electrical planning and
system construction department (Tel. +49 / 5361 / 9-29272).
!
Example: System constant 200 (manipulator type)
]
The following screen will be displayed after selecting constant No. 200 and the
following text will be displayed:
Please place the key disc in the drive
and acknowledge this by pressing F1!
F1
Page: 14-6
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
When you acknowledge the report by pressing the [F1] function key,
regardless of whether the disc is in the drive, the following text will be
displayed:
200: Manipulator type
Installed model: G120
(8)
Key disc missing! No modifications allowed!
F1
F2
F3
F4
F5
The manipulator type code will be displayed here, but it cannot be modified without the
key disc.
]
When the key disc is placed in the drive, press the [F1] function key and the
following text will be displayed:
200 : Manipulator type
Installed model: G 120 ( 8 )
Reading the data
Please wait...
Select:
Standardise
F1
F2
F3
F4
F5
If the checking and the reading have been successfully finished, constant type 200
will be displayed and the type code can now be modified.
200 : Manipulator type
Installed model: G 120 ( 8 )
1: G8
5: G100L
9:
2: G15
6: G10K
10:
3: G15L 7: G10L
11:
4: G100 8: G120
12:
Select: G 120
Standardise
F1
07.03.02
F2
F3
G120 L
G120H
G120LH
G80
(8)
Info
F4
F5
Elektroplanung-und Anlagenbau
Page:14-7
VRS 1
100 - 199 Servo constants
Hand-F2-F1
The servo constants affect the stopping of the robot when traversing.
]
The following screen will be displayed after selecting the [Hand] operating
mode and pressing the [F2] and [F1] function keys:
100 - 199: Servo constants
F1 = Amplification factor
F2 = Velocity pre-control
F3 = maximum position error
F4 = maximum bandwidth
F5 = Continue
Input:
F1
F2
F3
100
101
102
103
104 - 111
F4
F5
The selection options for control constants will be displayed.
The selection of the relevant servo constant is made by:
1. Pressing the relevant function key
or
2. Entering the relevant constant number via the decimal keyboard on the hand
console.
]
Press the [F5] function to display other selections for control constants.
100 - 199: Servo constants
F1 = V-max. voltage
F2 = Acceleration pre-control
F3 = Servo parameters (VRS1C)
F4 = I-section for positioning servo
F5 = Incremental step widths
Input:
F1
Page: 14-8
F2
F3
F4
104
105
106 - 111
120
130
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
100 P-control amplification factor
Hand-F2-F1-F1
The amplification factor affects the P-control of the axis drive system servo positioning
circuit and sets the difference values such as those between set and actual values for
the joining angle (lag distance).
The factor can:
• Be individually entered for each axis
• Improve the dynamic of the axes when traversing
• Call up a hard or smooth traversing stop
• Affect the controlling times of the axes
• Prevent over-swivelling
The pre-entered default amplification factor = 100 and this corresponds to the optimum
setting for the equipment and should only be modified in exceptional cases!
Factor > 100
• Hard traversing stop
• Faster control of the axes
• Negating over-swivelling
Factor < 100
• Slower traversing stop
• Slower control (lag error)
• Smooth traversing stop
Factor = 0
• The servo positioning circuit will be interrupted
• The alignment of the axis is no longer possible
Modifying the amplification factor is only possible in conjunction with
a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 100. The following screen will be displayed:
100:
Axis 1:
Axis 2:
Axis 3:
Amplification factor P-control
100
Axis 4: 100
100
Axis 5: 100
100
Axis 6: 100
Press ESC to abort
Input axis: 1 ->
Axis+
Axis-
F1
F2
F3
F4
F5
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new amplification factor.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-9
VRS 1
]
Press the [Return] key afterwards and the entered value will be imported and
displayed. The axis number in the input line will be increased by 1.
101 Velocity pre-control
Hand-F2-F1-F2
The velocity pre-control (in %) specifies how severe the effect of a modification to the
AE-set value will have on the amplifier of the axis drive system.
The velocity pre-control is used for calculating the axis velocity for the trajectory
module together with the entered pre-control factor (%).
This will directly affect the lag factor, as it will be decreased or be reset to zero.
A pre-condition here is that the robot axis must always be able to follow the trajectory
run due to its kinematics and the pre-entered velocity.
The pre-control factor can be individually corrected for each axis.
The default pre-entered pre-control factor = 100 and this corresponds to the optimum
setting for the equipment and should only be modified in exceptional cases!
Factor > 100
Increases the position error, as the relevant axis 'advances'.
Factor < 100
Increases the position error, as the relevant axis 'reverses'.
Factor = 0
The velocity pre-control is switched off. Drastic increase of the lag distances! The
position error is now proportional to the velocity.
Modifying the pre-control factor is only possible in conjunction with a
key disc!
Page: 14-10
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Place the key disc in the controller disc drive.
]
Select constant No. 101. The following screen will be displayed.
101:
Axis 1:
Axis 2:
Axis 3:
Velocity pre-control controller
100
Axis 4: 100
100
Axis 5: 100
100
Axis 6: 100
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
F3
F4
F5
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new pre-control factor.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-11
VRS 1
102 The maximum position error
Hand-F2-F1-F3
The position error is the difference between the set position and the actual position of
each axis.
If the set / actual difference is too big, i.e. an axis "limps about", the drive system will be
switched off and the error report: position error axis:__ will be displayed on the screen:
Example:
Control cycle 5 ms
z
Position error
CURR.
AE-status: CURR. = 15000
DEST. = 15500
The modifying of the maximum position error is only possible in
conjunction with a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 102. The following screen will be displayed.
102:
Axis 1:
Axis 2:
Axis 3:
Maximum position error servo
1500
Axis 4: 2000
2500
Axis 5: 3200
1600
Axis 6: 3200
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
F3
F4
F5
Displayed here are the number of bits that the axis (AE status) is permitted to be away
from the set position when the drive system has not yet been switched off.
Page: 14-12
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new position error value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number in the input line will be
increased by 1.
103 Maximum bandwidth
Hand-F2-F1-F4
The bandwidth:
• Results in personnel and machinery safety
• Identifies uncontrolled movements of the robot axes
• Offers security against read errors in the angle encoder system
During the traversing of the robot axes the AE value of each axis will be read in at a
regular cycle and verified against the previously saved value.
If the difference is greater than the maximum permitted bandwidth for this axis, the
drive system will be switched off and a corresponding error report will be displayed.
Example:
The maximum traversing velocity for axis 6 amounts to 1480 Bit/5 ms
•
•
CURREN
T
•
Control cycle
CURREN
T
•
CURRENT
traversing path
•
CURREN
T
h le r
• FeBandwi
B a n d bdth
re ite
2 00 0 Bit
Modifying the maximum bandwidth is only possible in conjunction
with a key disc!
07.03.02
Elektroplanung-und Anlagenbau
Page:14-13
VRS 1
]
Place the key disc in the controller disc drive.
]
Select constant No. 103. The following screen will be displayed.
103:
Axis 1:
Axis 2:
Axis 3:
Maximum bandwidth servo
1100
Axis 4: 680
1100
Axis 5: 1500
1100
Axis 6: 1500
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
F3
F4
F5
The maximum bandwidth pre-entered as the default setting for each axis will be
displayed.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new bandwidth value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number in the input line will be
increased by 1.
104 Vmax voltage
Hand-F2-F1-F5-F1
In this type of constant the control voltage setting can be adjusted for the nominal
motor rotation.
As a result of the increasing dimensions of the installed axis drive system, a
corresponding control adjustment is required for the various nominal motor rotations.
Each axis amplifier has relevant inputs or jumpers with which the nominal rotational
speeds of the connected motors can be set. (e.g. 3000 1/min, 4000 1/min or 6000
1/min). For each setting there must be a rotational control of exactly 3000 1/min, 4000
1/min or 6000 1/min when the amplifier is controlled using the maximum control setting
value of 9.000 V. The control setting value must be adjusted accordingly for any
deviations from the nominal rotation of the installed motor.
Example:
Nominal rotation = 3000 1/min.
Set amplifier to a nominal rotation of 3000 1/min. The maximum controller pre-set value
of 9.000 V does not need to be modified.
Page: 14-14
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Nominal rotation = 4000 1/min.
Set amplifier to a nominal rotation of 4000 1/min. The maximum controller pre-set value
of 9.000 V does not need to be modified.
Nominal rotation = 2500 1/min.
Set amplifier to a nominal rotation of 2500 1/min. The maximum controller pre-set value
of 9.000 V must be modified.
3000 1/min. = 9.000 V - -> 2500 1/min = 7.500 V
Nominal rotation = 3250 1/min.
Set amplifier to a nominal rotation of 3250 1/min. The maximum controller pre-set value
of 9.000 V must be modified.
4000 1/min. = 9.000 V - -> 3250 1/min = 7.313 V
Modifying the V max. voltage is only possible in conjunction with a
key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 104. The following screen will be displayed.
104:
Axis 1:
Axis 2:
Axis 3:
Voltage at V-max in [ V ]
9.000
Axis 4: 9.000
9.000
Axis 5: 9.000
9.000
Axis 6: 9.000
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
F3
F4
F5
]
Use [F1] or [F2] function keys to select the required axis No.
]
After pressing the [F5] function key enter the new decimal point.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number in the input line will be
increased by 1.
105 Acceleration pre-control
Hand-F2-F1-F2-F5-F2
The acceleration pre-control specifies how severe a modification to the rotational
setting for the axis amplifier can be.
This acceleration pre-control is used for calculating the axis acceleration for the
trajectory module together with the entered acceleration factor (%).
Because of this the acceleration will directly affect the lag factor, as it will be decreased
or be reset to zero.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-15
VRS 1
A pre-condition here is that the robot axis must always be able to follow the trajectory
run due to its kinematics and the pre-entered acceleration.
The acceleration factor can be individually corrected for each axis.
The default pre-entered acceleration factor = 100 and this corresponds to the optimum
setting for the equipment and should only be modified in exceptional cases!
Factor > 100
Increases the position error, as the relevant axis 'advances' during acceleration.
Factor < 100
Increases the position error, as the relevant axis 'reverses' during acceleration.
Factor = 0
The acceleration pre-control is switched off. There will be a drastic increase in the lag
distance!
The position error is now proportional to the acceleration.
Modifying the acceleration pre-control is only possible in conjunction
with a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 105. The following screen will be displayed.
105:
Axis 1:
Axis 2:
Axis 3:
Acceleration pre-control servo
100
Axis 4: 100
100
Axis 5: 100
100
Axis 6: 100
Press ESC to abort
Input axis: 1 ->
Axis + Axis -
F1
F2
F3
F4
F5
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new pre-control factor.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number in the input line will be
increased by 1.
Page: 14-16
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
106 - 111 Servo parameters (VRS1C)
Hand-F2-F1-F5-F3
The following constants 106 -111 are only for when a VRS1C - controller is used.
These constants do not have any significance if another controller is being used.
The constants affect the control response of the servo amplifier.
With the servo parameters you can:
• Set the characteristics of the rotational control circuit
• Limit the servo power for a low powered motor
• Specify the rotational direction of the motors and the resolvers in the
controller
] The following screen will be displayed after selecting the [Hand] operating
mode and pressing the [F2], [F1], [F5] and [F3] function keys:
106 .. 111: Servo parameter 1 for VRS1C
F1 = Proport. value adjust
106
F2 = Integral value adjust
107
F3 = Current reduction adjust
108
F4 = Adjust I-quadrat T
109
F5 = Continue
110 - 111
Input: F1 - F5,
106 - 111
F1
F2
F3
F4
F5
The selection options for the servo constants will be displayed.
The selection of the relevant servo constant is made by:
1. Pressing the relevant function key or
2. Entering the relevant constant number via the decimal key on the hand console
]
Other servo constants will be displayed after pressing the [F5] function key:
110 .. 111: Servo parameter 2 for VRS1C
110
F1 = Invert velocity set value
F2 = Invert positioning actual value 111
Input:
F1
07.03.02
F1 - F2,
F2
110 - 111
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:14-17
VRS 1
106 Amplification (P-content)
Hand-F2-F1-F5-F3-F1
With this constant the control characteristics for the internal rotational control circuit of
the servo amplifier can be optimised to the robot's mechanical properties.
The rotational control of the servo amplifier is normally realised via a PI-control. The
amplification and the time constant comprise both of the characteristic cases of such a
control.
The controller will react faster to the modified rotational setting values with increased
amplification. If the amplification that has been selected is too large, the control circuit
will cause audible vibrations.
The following are valid when entering a value:
• Lower value = greater amplification!
• Entered value range: 0 - 255
• Amplification value range: 1 - 255
Example:
Calculation formula for S&M series 26.50 servos:
Input value =
255
required amplificat ion
Attention! Danger!
Take great care when entering the calculated values. An improper entry can
destroy the servo module or the motors. Further information can be found in
the handbook supplied by the manufacturer of the servo.
Modifying the amplifier is only possible in conjunction with a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 106. The following screen will be displayed.
106:
Axis 1:
Axis 2:
Axis 3:
Servo P-content
128
Axis 4:
128
Axis 5:
128
Axis 6:
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
Page: 14-18
F2
(only VRS1C)
128
128
128
Input (0 - 255)
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new amplification.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number in the input line will be
increased by 1.
107 Time constant (I-content)
Hand-F2-F1-F5-F3-F2
With this constant the control characteristics for the internal rotation control circuit of
the servo amplifier can be optimised to the robot's mechanical properties.
The time constant specifies the velocity response of the rotational control circuits to a
modified rotational setting. The new value will be reached faster with a lower time
constant.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-19
VRS 1
The following are valid when entering a value:
• Lower value = greater time constant
• Input range: 0 - 255
• Time constant value range: 0.47 - 120 ms
Example:
Calculation formula for S&M series 26.50 servos:
255
• RC ;
required time constant
with R = 10kΩ and C = 47nF
Input value =
Attention! Danger!
Take great care when entering the calculated values. An improper entry can
destroy the servo module or the motors. Further information can be found in
the handbook supplied by the manufacturer of the servo.
Modifying the time constant is only possible in conjunction with a key
disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 107. The following screen will be displayed.
107:
Axis 1:
Axis 2:
Axis 3:
Servo I-content (only VRS1C)
128
Axis 4: 128
128
Axis 5: 128
128
Axis 6: 128
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
Input (0 - 255)
F3
F4
F5
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new time constant.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number in the input line will be
increased by 1.
Page: 14-20
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
108 Peak current reduction (PI-limit)
Hand-F2-F1-F5-F3-F3
The servo amplifiers are sub-divided into power classes.
In order to be able to operate a low powered motor, the peak current of the servo must
be limited.
The peak current limiting is given as a percentage reduction in relation to the peak
motor current listed in the handbook from the manufacturer of the servo.
Example:
Calculation formula for S&M series 26.50 servos:
Input value =
Peak motor current
• 255
Peak servo current
Attention! Danger!
Take great care when entering the calculated values. An improper entry can
destroy the servo module or the motors. Further information can be found in
the handbook supplied by the manufacturer of the servo.
Modifying the peak current limit is only possible in conjunction with a
key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 108. The following screen will be displayed.
108: Current reduction limit
Axis 1: 128
Axis 4:
Axis 2: 128
Axis 5:
Axis 3: 128
Axis 6:
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
07.03.02
F2
(only VRS1C)
128
128
128
Input (0 - 255)
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:14-21
VRS 1
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new current limit.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number in the input line will be
increased by 1.
109 Nominal current monitoring (I2T)
Hand-F2-F1-F5-F3-F4
In order to prevent the motor or the servo from being permanently overloaded, the
effective nominal current can be limited over a period of time.
The following calculation must be made for the motor peak / nominal currents and
servo peak / nominal current properties. The greater of the two calculated values must
then be used.
Example:
Calculation formula for S&M series 26.50 servos:
Peak current 

Input value =  80 •
 - 80
Nominal current 

Attention! Danger!
Take great care when entering the calculated values. An improper entry can
destroy the servo module or the motors. Further information can be found in
the handbook supplied by the manufacturer of the servo.
Modifying the nominal current monitoring is only possible in
conjunction with a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 109. The following screen will be displayed.
109:
Axis 1:
Axis 2:
Axis 3:
Servo I-quadrat-T
128
Axis 4:
128
Axis 5:
128
Axis 6:
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
Page: 14-22
F2
(only VRS1C)
128
128
128
Input (0 - 255)
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number in the input line will be
increased by 1.
110 Inverting the servo set value
Hand-F2-F1-F5-F3-F5-F1
The rotational direction of the motor (drive system side) and the rotational direction of
the robot axis (drive end) are permanently linked by the mechanics (gears, drive belts
etc.). As the controller expects a specific rotational direction of the robot axes or other
additional axes, the rotational direction of the motor must be set accordingly.
The following value can be entered for the rotational direction of an axis:
0 = normal output of the servo set value
1 = inverted output of the servo set value
!
Important note:
The correct rotational direction of an axis can be checked. Press the relevent F
(forwards) axis traversing key for the axis when the drive system is switched on.
The axis must now rotate in the F direction (see directional instructions for the
robot mechanics). If the axis rotates in the opposite R direction then the servo set
value must be inverted.
Attention! Danger of injuries!
If the servo set value has to be inverted, the actual positioning current value
(constant 111) must also be reset.
Modifying the set value inverting is only possible in conjunction with a
key disc!
07.03.02
Elektroplanung-und Anlagenbau
Page:14-23
VRS 1
]
Place the key disc in the controller disc drive.
]
Select constant No. 110. The following screen will be displayed.
110:
Axis 1:
Axis 2:
Axis 3:
Joint speed invert (only VRS1C)
0
Axis 4: 1
1
Axis 5: 1
0
Axis 6: 0
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
Input (0 - 1)
F3
F4
F5
]
Use [F1] or [F2] function keys to select the required axis No.
]
Select the inverting servo set value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number in the input line will be
increased by 1.
111 Inverting the positioning set value
Hand-F2-F1-F5-F3-F5-F2
The rotational direction of the motor and the rotational direction of the path measuring
systems (e.g. angle encoder) are permanently linked by the mechanics (gears, drive
belts etc.). The rotational direction of the motor must always concur with the rotational
direction of the path measurement system.
Attention! Danger of injuries!
If the rotational direction of the motor does not concur with the path
measurement system this will result in an uncontrollable axis movement.
The positioning actual value must be inverted accordingly.
The following value can be entered for the positioning actual value:
0 = normal evaluation of the positioning actual value
1 = inverted evaluation of the positioning actual value
!
Important note
Normally the same values must be entered in constants 110 and 111 for an ACmotor with a resolver (as path measurement system).
Modifying the positioning actual value inverting is only possible in
conjunction with a key disc!
Page: 14-24
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Place the key disc in the controller disc drive.
]
Select constant No. 111. The following screen will be displayed.
111: Joint position invert (only VRS1C)
Axis 1: 0
Axis 4: 1
Axis 2: 1
Axis 5: 1
Axis 3: 0
Axis 6: 0
Press ESC to abort
Input axis: 1 ->
Axis+ Axis -
F1
F2
Input
F3
(0 - 1)
F4
F5
]
Use [F1] or [F2] function keys to select the required axis No.
]
Select the inverting of the positioning actual value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number in the input line will be
increased by 1.
120 Integral content of the positioning
control
Hand-F2-F1-F5-F4
As form version 1.13i, the previously fixed Proportional-Positioning control can now be
supplied with an integral content. This Integral content can be separately set for each
axis using constant 120.
With this so created PP positioning control, an offset error can be integrated in the
path. Consequently a constant positioning deviation caused by an amplifier offset can
be path controlled.
In addition, when the drive system is switched off the "Watchdog" will be delayed. This
has the advantage that the positioning control remains set until the intermediate circuit
voltage of the amplifier has been completely reduced. This will also prevent any path
drifts related to amplifier offsets when the drive system is switched off.
]
Place the key disc in the controller disc drive.
]
Select constant No. 120. The following screen will be displayed.
120:
Axis 1:
Axis 2:
Axis 3:
Setting I-content positioning control
8
Axis 4: 8
8
Axis 5: 8
8
Axis 6: 8
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:14-25
VRS 1
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the required value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
Press the [Return] key to finalise and then the entered value will be imported and
displayed on the screen. The axis number in the input line will be increased by 1.
130 Editing the incremental step widths
This new function has been added so that the robot can be repositioned in accordance
with the precise data.
A precondition here is that the step width must be defined in degrees or millimetres and
the method defined as either Cartesian or rotary.
]
The following menu is displayed after constant 130 has been selected:
130:
Editing the incremental step widths
Cartesian increment:
1000
Rotary increment
+
F1
-
F2
1/10 mm
0
1/100mm
F3
1/100
1/100deg
DEGREE
F4
F5
]
Use [F1] to increase the entered value by 1; a precondition here is that the
cursor must have been set to the degree or mm lines via the [F5] key.
]
Use [F2] to reset the entered value back to 1
]
Use [F3] to activate the Cartesian increment line and values between 1 –
1,000 can now be entered.
]
Use [F4] to activate the rotary increment line and values between 1 – 1,000
can also be entered here.
]
Use [F5] to jump between the degree and mm lines.
Please read the “Incremental traversing” section in Chapter 6 “Hand mode“
regarding this.
Page: 14-26
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
200 - 299 Manipulator constants
Hand-F2-F2
Manipulator constants indicate special parameters for the robot that are required by the
controller for the precise calculation of the axis movement.
These are:
• Robot model
• Number of robot axes being used
• Maximum axis velocity
• Axis geometry (mechanical axis offsets)
• Basic angle encoder setting
• Upper and lower angle encoder limits
• Angle encoder resolution
• Maximum axis acceleration
• Angle encoder rotations etc.
]
The following screen will be displayed after selecting the [Hand] operating
mode and pressing the [F2] function key twice:
200 - 299: Manipulator constants
F1 = Manipulator type
F2 = Number of axes
F3 = Maximum axis velocity
F4 = Robot data
F5 = Continue
Input:
F1
F2
F3
F4
1
200
201
202
203 - 233
210 - 216
F5
Displayed here are the selection options for the manipulator constants. The required
constant can be selected by either pressing the relevant function key or by entering the
associated constant number.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-27
VRS 1
]
Use the [F5] function to display an additional selection. The following menu
will be displayed.
200 .. 299: Manipulator constants 2
F1 = Version
210
F2 = DRIVE SYSTEM OFF time
211
F3 = Maximum axis velocity in HAND 202
F4 = Autom. traversing in AUTO
213
F5 = Continue
(214 - 216)
Input:
(210 - 216, F1 - F5)
F1
F2
F3
F4
F5
200 Manipulator type
Hand-F2-F2-F1
The controller has been designed so that it can also be used for setting various robot
mechanical measurements and traversing properties.
This requires that for a precise calculation of the axis movement, model specific
parameters (constants) for the respective robot are present in the controller.
Modifying the manipulator type is only possible in conjunction with a
key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 200. The following screen will be displayed.
200: Manipulator type
Installed model: G120
(8)
1: G8
5: G100L
9: G120L
2: G15
6: G10K
10: G120H
3: G15L 7: G10L
11: G120LH
4: > G100 8: G120
12: G80
Selected: G100 (4)
Standardise
Info
F1
F2
F3
F4
F5
Displayed here will be a selection menu in which all robot models saved on the key
disc are listed. In the example the installed robot model is G120 and the selected robot
model is G100.
Page: 14-28
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
The selection of the robot model is made via the [Cursor] keys:
Arrow up/down = +/- a line
Arrow left/right = +/- a column
Depending on the key disc, a maximum of 96 different robot models will be displayed
for selection from which 12 will always be displayed on the screen at the same time.
]
When the key disc is in the drive you can use the Info [F5] function key to
display certain information regarding the selected robot model.
200: Manipulator type
************ROBOT MODEL G120*********************
*MANUFACTURER:
VOLKSWAGEN AG *
*SHORT NECK
LOAD
:120 KG
*
*SECURING: FLOOR
NO. OF AXES : 6
*
*CONTROLLER: VRS1
AC WITH TOOL
*
*DATE 31.10.94
*
**********************************************************
F1
F2
F3
F4
F5
]
Press the [Esc] key in order to return to the manipulator type overview.
]
After selecting the manipulator type you can standardise the selected robot
model by pressing the [F1] function key and this will also activate the model
specific constants in the computer system.
If this was unsuccessful, i.e. a code number was selected to which a robot model has
not been assigned, the following error report will be displayed as a result of the invalid
code number:
Model unavailable !
51
Confirm using ESC /MOS
F1
]
F2
F3
F4
F5
Press the [Esc] key to return to the previous constant menu.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-29
VRS 1
201 Number of additional axes
Hand-F2-F2-F2
The controller software can control a maximum of 12 axes at the same time (6
standard axes + 6 additional axes). In the basic installation there are only 6 robot axes.
Each additional axis that will be controlled together with the standard axes becomes an
additional axis; e.g. robot at a traversing unit.
!
The number of additional axes must be entered prior to the programming of the
initial TCP.
The modifying of the additional axes is only possible in conjunction
with a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 201. The following screen will be displayed.
201:
Number of additional axes
Maximum : 6
Minimum : 0
Default:
0
Press ESC to abort
Input: (0 - 6)
F1
F2
F3
F4
F5
The number of the previously entered additional axes will be displayed under 'Preinstalled'.
]
Enter the new number of additional axes. The entry always refers only to
additional axes. Pre-installed "0" means: 6 axes will be controlled, but no
additional axis!
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen.
Page: 14-30
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
202 Maximum axis velocity (bit/5 ms)
Hand-F2-F2-F3
The entering of a value for the maximum axis velocity specifies how fast the respective
axis is permitted to move within a set period of time (control cycle = 5 ms).
If this is exceeded the controller will immediately switch the robot off (lag error or
bandwidth).
Measurement system:
angle encoder or resolver
Measurement unit:
bit
Measurement cycle:
control cycle (5 ms)
Due to the nominal motor rotation, gearing transfers, angle encoder resolution and
angle encoder reduction ratios, a specific standard value must be pre-entered for each
axis that you are only permitted to modify if the above mentioned values are being
modified.
Modifying the maximum axis velocity is only possible in conjunction
with a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 202. The following screen will be displayed.
202:
Axis 1:
Axis 2:
Axis 3:
Maximum axis velocity
3072
Axis 4: 4096
3072
Axis 5: 4096
3072
Axis 6: 4096
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
F3
F4
F5
The number of bits will be displayed which set the highest maximum rotation for each
axis within the control cycle.
] Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new axis velocity.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis value in the input line will be increased
by 1.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-31
VRS 1
203 - 230 Robot data
Hand-F2-F2-F4
The robot data contains:
• Mechanical dimensions of the axes
(axis geometry)
• Details from the measurement system (angle encoder/resolver)
Modifying the robot data is only possible in conjunction with a key
disc!
]
Place the key disc in the controller disc drive.
]
Select the [Hand] operating mode and press the [F2] - [F2] - [F4] function
keys. The following selection menu will be displayed:
203 - 206: Manipulator data
1
F1 = Axis geometry
F2 = AE basic settings
F3 = AE minimum (lower softw-limit)
F4 = AE maximum (upper softw-limit)
F5 = Continue
Input
F1
F2
F3
F4
203
204
205
206
207-209
F5
The required constant can be selected by either pressing the relevant function key or
by entering the associated constant number.
]
After pressing the [F5] function key additional selections will be displayed. The
following menu will be displayed:
207 - 209: Manipulator data
2
F1 = AE resolution
F2 = Maximum axis acceleration
F3 = Angle encoder
F4 = Justageoffset
F5 = Continue
Input:
F1
Page: 14-32
F2
F3
F4
207
208
209
224
220 - 223
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Press the [F5] function key again and additional robot data will be offered for
selection.
]
220 - 223: Manipulator data3
F1 = Angle offset
F2 = Axis couplings
F3 = EMT-velocity
F4 = EMT-offset
F5 = Continue
Input:
F1
]
F2
F3
220
221
222
223
230 - 233
F4
F5
Press the [F5] function key yet again and even more robot data will be offered
for selection.
230 .. 233: Manipulator data4
F1 = Set rotational counter
F2 =
F3 =
F4 =
F5 = Continue
Input:
F1
F2
F3
230
203 - 207
F4
F5
203 Axis geometry
Hand-F2-F2-F4-F1
The axis geometry in the controller refers to the mechanical length (mm) of each
individual robot axis.
These values are construction conditions pre-entered and saved in the computer.
]
The entered length displayed on the screen applies specially to the selected
robot model and in normal cases you are not permitted to modify them!
]
Previously programmed sequences or sub-programs ca no longer be run after
the axis geometry has been modified.
Modifying the axis geometry is only possible in conjunction with a key
disc!
07.03.02
Elektroplanung-und Anlagenbau
Page:14-33
VRS 1
]
Place the key disc in the controller disc drive.
]
Select constant No. 203. The following screen will be displayed:
203:
Axis 1:
Axis 2:
Axis 3:
Axis geometry data
793
Axis 4: 0
300
Axis 5: 753
800
Axis 6: 192
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
Hand-config.
F3
F4
F5
The axis lengths in mm will be displayed.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new axis length in mm.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen.
The following illustration shows an example of the reference points of the individual
axis measurements (1 - 6) for the LSV25/A1.
The axis geometry for axis 4 describes the vertical distance between the axis centre
point of axis 3 and the symmetrical axis of axis 4. In the above example, the distance =
"0", as both axes cut the same point.
Page: 14-34
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
204 AE basic settings
Hand-F2-F2-F4-F2
The angle encoder basic settings are determined in the marking position (basic
mechanical position of the axes). In this position the axes are positioned vertical to one
another and approximately describe the centre of their moving areas.
The angle encoder or resolver will also be standardised in this basic mechanical
position. They do not have to be set precisely to any one value.
The difference between the present AE position and the fixed standard values
(normally in the centre of the value ranges) will be taken into consideration as an offset
for all positions and in teaching in the future.
Because of these difference values the controller will calculate the precise run for
further axis movements.
Advantages:
• No mechanical setting of the path measurement system is required
• Trouble free setting up after exchanging the angle encoder
• It is possible to exchange the angle encoders for another having different
resolutions (24, 20, 18 bit etc.)
• Programmed sequences can be run on different robot systems using the
same type of model (compatible)
Take into consideration that normally these values are not to be modified, as
previously programmed sequences will no longer run.
!
Modifying the amplification factors is only possible in conjunction
with a key disc!
07.03.02
Elektroplanung-und Anlagenbau
Page:14-35
VRS 1
]
Place the key disc in the controller disc drive.
]
Select constant No. 204. The following screen will be displayed.
204:
Axis 1:
Axis 2:
Axis 3:
AE basic positions [bit]
8000000
Axis 4: 8000000
8000000
Axis 5: 8000000
8000000
Axis 6: 8000000
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
F3
F4
F5
The standard values for AE basic positions in bits will be displayed.
]
Use [F1] or [F2]function keys to select the required axis No.
]
Enter the new basic setting value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
205 AE lower limit (lower software limit)
Hand-F2-F2-F4-F3
The traversing range of the robot axes is not only limited by electrical and mechanical
end stops (with the exception of axes 4 and 6), but it is also monitored by the controller
against over-running the AE upper and lower limits.
After reaching a limit value the relevant axis will no longer traverse in this direction.
In corresponding error report will be displayed on the screen, however the drive system
will not be switch off.
The AE lower limit limits the robot traversing range in direction R. The angle encoder
counts downwards (towards zero).
Due to the actual traversing range of each axis the standard default values have been
set so that neither the electrical nor the mechanical end stops will be reached.
The modifying of the limit value is only possible in conjunction with a key
disc!
Page: 14-36
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Place the key disc in the controller disc drive.
]
Select constant No. 205. The following screen will be displayed.
205:
Axis 1:
Axis 2:
Axis 3:
AE minimum (lower software limit)
-150.00
Axis 4: -700.00
-055.00
Axis 5: -100.00
-210.00
Axis 6: -700.00
Press ESC to abort
Input axis: 1 ->
Axis +
Axis - Current value
F1
F2
F3
F4
F5
The angle encoder position of the lower traversing range (lower software limit) is
displayed in degrees for each axis, with reference to the basic axis position.
] Use [F1] or [F2] function keys to select the required axis No.
]
Enter a new limit value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
Automatic setting of the AE lower limit
] Traverse the axis to the lower (minimum) limit position.
]
Select constant No. 205. The following screen will be displayed.
205:
Axis 1:
Axis 2:
Axis 3:
AE min (lower soft limit)
-150.02
Axis 4: -700.00
-055.00
Axis 5: -100.00
-210.00
Axis 6: -700.00
Press ESC to abort
Input axis: 1 ->
Axis+
Axis- Current value
F1
F2
F3
F4
F5
]
Use [F1] or [F2] function keys to select the required axis No.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the function key [F3] and this will record the current position of the axis
that has just been selected as AE lower limit.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-37
VRS 1
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
The current position of the angle encoders has now been saved as the AE lower limit.
206 AE upper limit (upper software limit)
Hand-F2-F2-F4-F4
The traversing range of the robot axes is not only limited by electrical and mechanical
end stops (with the exception of axes 4 and 6), but it is also monitored by the controller
against over-running the AE upper and lower limits.
After reaching a limit value the relevant axis will no longer traverse in this direction.
In corresponding error report will be displayed on the screen, however the drive system
will not be switch off.
The AE upper limit limits the robot traversing range in direction V. The angle encoder
counts upwards here.
Due to the actual traversing range of each axis the standard default values have been
set so that neither the electrical nor the mechanical end stops will be reached.
Modifying the limit values is only possible in conjunction with a key
disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 206. The following screen will be displayed.
206:
Axis 1:
Axis 2:
Axis 3:
AE maximum (upper software limit)
150.00
Axis 4: 700.00
055.00
Axis 5: 100.00
210.00
Axis 6: 700.00
Press ESC to abort
Input axis: 1 ->
Axis +
Axis - Current value
F1
F2
F3
F4
F5
The angle encoder position of the upper traversing range (upper software limit) is
displayed in degrees for each axis, with reference to the basic axis position.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter a new limit value.
Page: 14-38
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the function key [F3] this will record the current position of the axis that
has just been selected as AE upper limit.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
Automatic setting of the AE upper limit
] Traverse the respective axis to the upper (maximum) limit position.
]
Select constant No. 206. The following screen will be displayed.
206:
Axis 1:
Axis 2:
Axis 3:
AE maximum (upper software limit)
149.98
Axis 4: 79.52
120.26
Axis 5: 120.01
035.54
Axis 6: 250.53
Press ESC to abort
Input axis: 1 ->
Axis +
Axis - Current value
F1
F2
F3
F4
F5
]
Use [F1] or [F2] function keys to select the required axis No.
]
Press the function key [F3] this will record the current position of the axis that
has just been selected as AE upper limit.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
The current position of the angle encoders has now been saved as the AE upper limit.
207 AE resolution (bit/90 degrees)
Hand-F2-F2-F4-F5-F1
The angle encoder resolution (bit/90 degree) tells you how many bits the respective
angle encoder / resolver will set for an axis rotational movement of 90 degrees. The
pre-entered values are specifically fixed for the mechanical conditions of each robot
model and do not need to be modified.
Exception:
When using additional axes, for which no calculation exists.
Modifying the AE resolution is only possible in conjunction with a key
disc!
07.03.02
Elektroplanung-und Anlagenbau
Page:14-39
VRS 1
]
Place the key disc in the controller disc drive.
]
Select constant No. 207. The AE resolution, for VK10 here, will be displayed.
207:
AE resolution bit/90 degrees
A1: -365568.00000
A4: -245760.00000
A2: 365568.00000
A5: 245760.00000
A3: 365568.00000
A6: -153600.00000
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
F3
F4
F5
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new AE resolution.
]
Use the [F5] function key to enter the decimal point.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen.
208 Maximum axis acceleration (degs/sec2)
Hand-F2-F2-F4-F5-F2
The maximum axis acceleration describes the highest permitted velocity modification
per second and is entered in quadrants of degs/sec.
a = v / ∆t
Due to the different kinematics a specific value must be determined for each axis that is
required by trajectory module l for the precise calculation of the axis movement and to
protect the robot mechanics from being overloaded. With linear axes the calculation will
be made, depending on the requirements, in mm, cm or m instead of degrees.
Example: for acceleration times
Basic axes
∆t
= 0.5 - 1.0 sec
Hand axes
∆t
= 0.2 - 0.5 sec
You are not permitted to modify the pre-entered default values. Exceptions are
mechanical modifications to the axis.
Modifying the maximum axis acceleration is only possible in
conjunction with a key disc!
Page: 14-40
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Place the key disc in the controller disc drive.
]
Select constant No. 208. The following screen will be displayed.
208:
Axis 1:
Axis 2:
Axis 3:
Maximum axis acceleration degs./sec2
504.00
Axis 4: 2000.00
504.00
Axis 5: 2000.00
504.00
Axis 6: 2400.00
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
F3
HAND
.
F4
F5
The pre-entered default values will be displayed for the maximum axis acceleration of
all axes.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new axis acceleration.
]
Press the [F5] function key to enter the decimal point.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
Axis acceleration in Hand mode
Hand-F2-F2-F4-F5-F2-F4
When the axis acceleration is in [Hand] operating mode the maximum permitted axis
acceleration will be reduced to the set percentage content. In [Single Step] and
[Automatic] operating modes this constant does not have any significance.
The modifying of the maximum axis acceleration is only possible in
conjunction with a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 208. The following screen will be displayed.
208:
Axis 1:
Axis 2:
Axis 3:
Maximum axis acceleration in degs./sec2
504.00
Axis 4: 2000.00
504.00
Axis 5: 2000.00
504.00
Axis 6: 2400.00
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
07.03.02
F2
F3
HAND
.
F4
F5
Elektroplanung-und Anlagenbau
Page:14-41
VRS 1
]
Press the function key [F4]. The following screen will be displayed.
208:
Axis acceleration in HAND mode
Minimum
Default
: 10%
: 33%
Maximum : 200%
Input :
.
F1
F2
F3
F4
F5
]
The default value for the axis acceleration in the [Hand] operating mode will
be displayed on the screen.
]
Enter the new axis acceleration in the [Hand] operating mode.
]
Confirm the entry by pressing the [Return] key.
]
Use the [Esc] key to exit the input menu.
209 Angle encoder rotational speed
Hand-F2-F2-F4-F5-F3
Each axis position in the area (turning angle) will be recorded by a very high resolution
path measuring system (maximum of 16,77 million increments).
The following are used as the measuring system according to the type of axis drive
system:
• With AC drive systems RESOLVER (analog/digital conversion)
• With DC drive systems ANGLE ENCODER (optical, absolute).
Resolver
Due to the fixed coupling of the motor / resolver and the resolution of the 12 bit analog /
digital converter, a modification to the pre-entered default value is not necessary
(entered value = 4096).
Angle encoder
The measuring range of the angle encoder will vary depending on the type installed.
The number of the angle encoder revolutions is tells you how many revolutions it took
to reach the end of the entire measuring area. This number is given on the model
nameplate of the encoder:
256
U á 4096 bit
=
1 048 576
bit
4094
U á 4096 bit
=
16 777 216 bit
Due to the different lengths of the traversing paths of the axes, different angle encoders
can also be used. In order to record and calculate the precise axis position in the area,
the number of revolutions for the respective encoder being used must be entered.
Modifying the angle encoder rotational speed is only possible in
conjunction with a key disc!
]
Place the key disc in the controller disc drive.
Page: 14-42
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Select constant No. 209. The following screen will be displayed.
209:
Axis 1:
Axis 2:
Axis 3:
Angle encoder revolutions
4096
Axis 4: 4096
4096
Axis 5: 4096
4096
Axis 6: 4096
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
F3
F4
F5
The number of revolutions for the respective installed angle encoder will be displayed
for each axis.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new angle encoder rotational speed.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
If the angle encoder has been exchanged, the entered default values must be checked.
If another angle encoder has been installed for an axis, the necessary modifications
must be entered.
210 Operating system version
Hand-F2-F2-F5-F1
With new performance features or the optimising of already existing program sections,
the controller will carry out an ongoing software update.
An enhancement or modification to the operating system is indicated by an increase in
the versions No. (e.g. from 1.9 to 1.10) as well as the details of the date of issue.
The operating system version being used in this computer will be displayed after the
constant type number.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-43
VRS 1
Select constant No. 210. The following screen will be displayed.
]
210:
Versions number software
Operating syst.
Date
Trajectory pl.
Date
:
:
:
:
Version 1.13 i
06.08.98
Version 1.13 i
06.08.98
Press ESC to abort
F1
]
F2
F3
F4
F5
Press the [Esc] key to return to the constants selection menu.
211 ACTUATORS OFF time
Hand-F2-F2-F5-F2
If the robot is waiting under the permanent control of the axes, at a point where a
programmed wait condition is being fulfilled, the drive system will be automatically
switched off after the drive system OFF time (maximum of 3,600 seconds) has expired.
This function is only effective in the [Automatic] operating mode and is used for
energy saving as well as for reduce the load on the drive system.
Attention! Mortal danger!
As soon as the safety circuit (K1A/B) is closed and the wait condition has
been fulfilled, the drive system will be automatically switched on again and
the robot will continue with its operating program.
]
Select constant No. 211. The following screen will be displayed.
211:
ACTUATOR OFF time in seconds
Minimum :
Default
:
0
0
Maximum : 3600
Press ESC to abort
Input :
(0 - 3600)
F1
F2
F3
F4
F5
]
Enter the new drive system OFF time. The entering of "0" deactivates this
function.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen.
Page: 14-44
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
212 Maximum axis velocity in Hand mode in %
Hand-F2-F2-F5-F3
With this constant type you can individually set the traversing velocity within the
[Hand] operating mode for each axis.
For safety reasons (DIN EN775) you are only permitted to traverse the robot axes in
the [Hand] operating mode at only a maximum velocity of 250 mm/sec.
In order to guarantee this, the individual maximum axis traversing velocities are limited
to just a percentage of normal:
• for coupled equipment at 10 % of the maximum traversing velocity
• for linear units to 1 % of the maximum traversing velocity
The axis velocity can be modified by the relevant input within the 10%.
Modifying the percentage axis velocity is only possible in conjunction
with a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 212. The following screen will be displayed.
212: Maximum axis velocity for HAND mode in %
Axis 1: 10%
Axis 4: 10%
Axis 2: 10%
Axis 5: 10%
Axis 3: 10%
Axis 6: 10%
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
F3
F4
F5
The previously set percentage axis velocity will be displayed for each axis.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new axis velocity.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-45
VRS 1
213 Running in Automatic mode
Hand-F2-F2-F5-F4
If an interruption occurs to the program, due to an operating mode change, whilst
running in the [Automatic] operating mode, the switching on of the drive system will be
prevented after returning to this operating mode, if a robot axis has moved from the
switching off point and gone out of its tolerance range.
This safety function is used to prevent a collision. This will ensure that the robot can
only traverse to the next programmed TCP under operator control in the [Single Step]
mode.
Without this safety function the robot will automatically traverse the direct test path from
any position to the selected TCP after the drive system has been switched back on in
the [Automatic] operating mode! This can result in collisions. For this reason the
following screen is displayed after the [Automatic] operating mode is reselected:
AUTO is not posssible! Please use S-STEP
Acknowledge error using ESC / MOS:
F1
]
F2
F3
F4
F5
The following screen will be displayed after selecting the [Single Step]
operating mode:
SSTEP
STOP
PLC1
ACTUATOR POWER OFF !
V : 10%
Sequence : 1
Pnt-Inst
F1
]
F2
F4
F5
Switch on the drive system. The [F1] and [F2] function key assignments will
change to:
F1 = SSF
F2 = SSS
]
F3
Point : 0
REF-OFF V in %
=
=
Single Step FORWARDS
Single Step STOP
By pressing and holding down the [F1] function key the robot can be traversed
forwards to the next programmed point.
Page: 14-46
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
If you have traversed to the point by using STOP, you can then switch off the
drive system.
]
Select the [Automatic] operating mode.
]
Switch the drive system on again.
The robot will continue running the automatic program.
This anti-switching on protection is switched on as a normal part of the operating
system!
Should you require this protection to be lifted in certain special cases, only
qualified personnel are permitted to carry this out!
The lifting of the anti-switching protection is only possible in
conjunction with a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 213. The following screen will be displayed.
213 :
Autom. START in AUTO
Default :
OFF
Press ESC to abort
On
Off
F1
]
F2
F3
F4
F5
Press the [F1] function key and the automatic traversing will be enabled. The
displayed default setting will change to ON.
214 Filter functions
Hand-F2-F2-F5-F5-F1
The transfer responses that occur with a velocity modification will be shown here with
the filter functions. Because of the filter functions a smooth, i.e. vibration-free traversing
stop, will be achieved.
Certain mechanics require filter functions. Modification to the standard filter settings
can result in damage to the mechanics!
You can select between 2 different types of traversing for the transfer responses:
• Trajectory filter: calculates the velocity profile using the filter functions (filter
functions are switched on).
• Axis filter: the velocity profile is calculated using vibration limiting (filter
functions are switched off).
07.03.02
Elektroplanung-und Anlagenbau
Page:14-47
VRS 1
Read the "Velocity profile" section in chapter 7 "Programming the sequences"
for further information regarding this.
We recommend that the initial traverse is with filter function = ON, as an optimisation of
the respective robot will be carried out here. A movement sequence can be time
optimised and can be traversed vibration-free.
Modifying the filter functions is only possible in conjunction with a
key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 214. The following screen will be displayed (for a VK10
here):
214 :
Filter - function
Filter - function : ON
Trajectory filter : 200 ms
Input :
F1
F2
ON
OFF
Axis
filter
F3
F4
F5
]
Press the function key [F3] = ON, in order to switch on the filter function.
]
Press the function key [F4] = OFF, in order to switch off the filter function (the
velocity profile will be calculated using the limited vibration).
Trajectory filter
The trajectory filter will affect the transfer responses, so that a velocity modification is
shown with the trajectory interpolation. A smooth, i.e. vibration-free transfer response
can be achieved for linear, circular, swivel and spline interpolation methods.
The trajectory filter is optimised for each robot model. The trajectory time is optimised
using the displayed constants, the traversing will be vibration-free and this should not
be modified.
The trajectory filter time will only be taken into consideration when the filter functions
are switched on.
]
Place the key disc in the controller disc drive.
]
Select constant No. 214. The following screen will be displayed.
214 :
Filter - function
Filter - function : ON
Trajectory filter : 200 ms
Input :
F1
Page: 14-48
F2
ON
OFF
Axis
filter
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The filter time setting (200 ms) for the trajectory interpolation method will be displayed.
]
Enter the filter time for the trajectory interpolation.
]
Confirm the entry by pressing the [Return] key.
]
Use the [Esc] key to exit the menu.
Axis filter
The axis filter will affect the transfer responses of each axis, so that a velocity
modification is shown for a PTP interpolation. A smooth, i.e. vibration-free velocity
transfer of all axes can be achieved using the with PTP interpolation method.
The axis filter is optimised for each robot model. The trajectory time is optimised using
the displayed constants and the traversing will be vibration-free. This should not be
modified. The axis filter times will only be taken into consideration when the filter
functions are switched on.
]
Place the key disc in the controller disc drive.
]
Select constant No. 214.
]
Press the function key [F5]. The following screen will be displayed.
214:
Axis 1:
Axis 2:
Axis 3:
Axis-filter in [ms]
220
Axis 4: 200
220
Axis 5: 200
220
Axis 6: 200
Press ESC to abort
Input axis: 1 ->
Axis+ Axis-
F1
F2
F3
F4
F5
The filter time settings will be displayed in ms for each axis.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-49
VRS 1
215 Joystick - selection
Hand-F2-F2-F5-F5-F2
In order to select or de-select the joystick, a new constant has been included as from
version 1.12. The joystick can be deselected if it becomes defective.
215 :
Choise of joystick
Setting :
(ACTIVE)
Choise (F1 = active, F2 = passive)
Active
Passive
F1
F2
F3
F4
F5
You can only select or deselect the joystick using [F1] or [F2]. For cartesian traversing
only the axis traversing keys are valid when the joystick is switched to passive.
The following functions are assigned to the keys:
1 V / R – 3 V / R = X, Y & Z fast and 4 V / R – 6 V / R = X, Y & Z slow.
216 System and station editing
Hand-F2-F2-F5-F5-F3
Each system and each station can be allocated a name. These names can be edited
using constant 216. The system and station texts are shown on each page of the print
out. The program can easily be assigned for printing out on another computer. The
edited names will be displayed on the hand console screen in Automatic or Single-Step
operation.
216 :
Editing systems and stations
System name :
Station name :
System
F1
Page: 14-50
Station
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The text editor
This editor offers the possibility of replacing (editing) the text displayed in the systems /
stations menu via entering alphanumerical text.
]
After the selection has been made using [F1] or [F2] function keys the
systems / stations text editor menu will be displayed.
216 :
System and station editor
System name :
Station name :
ABCDEFGHIJKLMNOPQRSTUVWXYZ ?!&().,;:/-<>
∧
Reset.
Delete Î[ ] [ ]Í Ins/O-W ABCabc
F1
Line 3:
Line 4:
Line 6:
Line 7:
F2
F3
F4
F5
Text line for system name
Text line for station name
Available letters and special characters are displayed here.
Information pointer (^) for a hand console without alphanumerical keyboard,
that can be positioned beneath the letter or special character that is to be
edited by using the joystick or by pressing the [Axis traverse] keys (1V 1R).
The function keys have the following assignments:
[F1] Return (only for old hand consoles)
Import the letter / character that is positioned beneath the information pointer
[F2] Delete
Individual characters or delete the complete text line using [SHF] and [F2]
[F3] Copy to buffer (memory)
The text entered in lines 3 or 4 can be copied to or inserted from the buffer using
[SHF] and [F3]
[F4] Switch between the insert / overwrite mode
[F5] Switch between capital letters / small letters
220 Angle offsets (degrees)
Hand-F2-F2-F4-F5-F5-F1
Angle offsets indicate the default possibilities for axis angles, provided that a
mechanical marking position opposite the standard marking position has been
modified.
Example LSV 25/A1:
The marking position for axis 1 is at 180 degrees and the one for axis 4 is moved to 90
degrees.
A correction input for axis 4 is required here, so that each future calculation of the axis
position can be made after the recalculation of the mechanical marking position in the
mathematical basic position.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-51
VRS 1
Modifying the angle offset value is only possible in conjunction with a
key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 220. The following screen will be displayed.
220:
Axis 1:
Axis 2:
Axis 3:
Angle offsets (degrees)
0.00
Axis 4: 0.00
0.00
Axis 5: 0.00
0.00
Axis 6: 0.00
Press ESC to abort
Input axis: 1 ->
Axis+ Axis-
F1
F2
F3
F4
F5
The possible correct angle offset setting will be displayed for each axis.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
221 Axis coupling factors
Hand-F2-F2-F4-F5-F5-F2
Axis coupling (feedback) is used when inevitable further mechanical turning is required
due to the turning of an axis.
Example:
Axis 4 ->
Axis 4 ->
Axis 5 ->
axis 5
axis 6
axis 6
A compensation can be achieved by the entering of coupling factors (except for
individual axis traversing in the [Hand] and [Test] operating modes).
Modifying the axis coupling factors is only possible in conjunction
with a key disc!
Page: 14-52
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Place the key disc in the controller disc drive.
]
Select constant No. 221. The coupling factor, for a VK10 here, will be
displayed.
221:
Mechanical axis coupling factors
K 1:-0.012500
(4→5)
K 2:0.020250
(4→6)
(5→6)
K 3:-0.020000
Press ESC to abort
Input axis: 1 ->
K+
K-
F1
F2
.
F3
F4
F5
]
Enter the factor.
]
Confirm the entry by pressing the [Return] key.
]
Use the [F5] function key to enter the decimal point.
]
Use the [F1] function key to select the next factor (K1 - K3) for entering.
Example:
The coupling factor must be determined for axis 5.
First of all, all hand axes must be traversed to the mark. Axis 4 will now be traversed
through 360 degrees as in test. Now axis 5 must be traversed in test again to the
marking position. The angle, through which axis 5 must be turned, divided by 360
degrees determines the K1 coupling factor.
222 Automatic adjustment velocity (bit/5 ms)
Hand-F2-F2-F4-F5-F5-F3
The traversing velocity for the automatic adjustment (EMT) is programmed for
equipment having the relevant adjustment device. The automatic adjustment velocity
tells you how far you are permitted to move an axis within a computer cycle (5 ms) for
the automatic adjustment movement. In order to attain precise results using the
automatic adjustment, this velocity must be greatly reduced (creep traversing).
Take into consideration that a modification to the automatic adjustment velocity
can result in standardisation errors. Only use the original constants for the
connected equipment.
!
Modifying the automatic adjustment velocity is only possible in
conjunction with a key disc!
]
Place the key disc in the controller disc drive.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-53
VRS 1
]
Select constant No. 222. The following screen will be displayed.
222:
Axis 1:
Axis 2:
Axis 3:
EMT - velocity bit / 5 ms
5
Axis 4: 7
5
Axis 5: 7
5
Axis 6: 5
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
F2
F3
F4
F5
Displayed here are the number of bits that you are permitted to set for each axis within
the control cycle (5 ms) for the automatic adjustment.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number will be increased by 1.
223 EMT - Offset
Hand-F2-F2-F4-F5-F5-F4
Different offsets are given for the robot models that have an adjustment device for the
automatic adjustment. These are given for both the equipment and the adjustment
device and compensate for a standardisation error during the adjustment.
!
Take into consideration that a modification to the automatic adjustment offsets
can result in standardisation errors. Only use the original automatic adjustment
constants for the connected equipment.
Modifying the automatic adjustment offsets is only possible in
conjunction with a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 223. The following screen will be displayed.
223:
Axis 1:
Axis 2:
Axis 3:
EMT - Offset
9
Axis 4: 56
32
Axis 5: 87
54
Axis 6: 37
Press ESC to abort
Input axis: 1 ->
Axis +
Axis -
F1
Page: 14-54
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The possible correct offset settings for each axis will be displayed.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Enter the new value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number will be increased by 1..
224 Adjustment offsets
Hand-F2-F2-F4-F5-F4
Due to the continually present elasticity of the robot mechanics (especially gearing
elasticity), the problem exists that a precise reproduction of the zero adjustment can
only be attained under the same conditions (especially axis positioning and load
bearing).
In practise this can result in a problem where the tool must be removed from the robot
head due to a loss of adjustment or for checking the correct zero position or the zero
position for all axes will not be achieved at the same time.
For this reason the option exists in the controller, to enter up to 7 adjustment offsets for
each axis at the end of a correct standardisation or for teaching. Each tool can be
assigned its own (tool specific) adjustment offset.
Read the "Angle encoder standardisation using adjustment offsets" section in
chapter 13 "Test" for more information regarding this.
Modifying the adjustment offsets is only possible in conjunction with
a key disc!
]
Place the key disc in the controller disc drive.
]
Select constant No. 224. The following screen will be displayed.
224:
Adjustment offsets TL No 1
Axis 1: 0
Axis 2: 0
Axis 3: 0
07.03.02
Axis 4: 0
Axis 5: 0
Axis 6: 0
Input axis: 1 ->
Axis +
Axis -
TL+
TL-
F1
F3
F4
F2
F5
Elektroplanung-und Anlagenbau
Page:14-55
VRS 1
The entered or taught adjustment offsets for each axis will be displayed for the selected
tool.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Press [F3] or [F4] function keys in order to select a tool number.
]
Enter the new adjustment offset.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
Page: 14-56
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
230 Editing AE values
Hand-F2-F2-F4-F5-F5-F5-F1
If a robot has been wrongly standardised the taught program will no longer match after
a standardisation correction. A correction will be necessary.
For this reason it is possible to edit the AE values.
!
Take into consideration, that if the SCC board or the RSC boards must be
changed in a robot system, the AE values will be lost.
]
Place the key disc in the controller disc drive.
]
Select constant No. 230. The following screen will be displayed.
230:
Axis
A1:
A2:
A3:
Editing the AE values
Stand ActualAE
AEstnd
ja
120000
120000
ja
000000
000000
ja
000000
000000
Axis 1
Axis +
Axis - Ed.actual
F1
F2
F3
AEp-up
120000
000000
000000
Ed.Norm AE=p-up
F4
F5
The AE current value or the values saved after a power-up will be displayed for each
axis.
]
Use [F1] or [F2] function keys to select the required axis No.
]
Press the function key [F3] or [F4] in order to select current AE or standard
AE.
]
Enter the new value.
]
If you have more than 6 axes in the robot system, press [F1] or [F2] function
keys in order to select an axis > 6.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen. The axis number displayed in the input line will
be increased by 1.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-57
VRS 1
Hand-F2-F2-F4-F5-F5-F5-F2
231 Accelerating factors and braking
factors for stopping
Braking factor for stopping
This constant has been included for the KLSV xxx mechanics.
The “0” setting is valid for all previous robot models and corresponds to the previously
used acceleration and braking ramps.
If these ramps induce mechanical vibrations, they can be dampened by using constant
type 231.
!
These functions only apply to the [SINGLE – STEP] operating mode.
]
Put the key-disc in the control system floppy drive.
]
The following menu is displayed after the relevant function key combination
has been pressed:
231:Accelerating and braking factors for stopping
F3 = Braking factor for stopping
:
0
F4 = Accelerating factor
:
0
+
-
F1
]
Braking fac Accel. fac
F2
F3
F4
Accel.
F5
Press [F3] and then enter a value between 0 – 200 in order to extend the
braking path
Vb
Vb
SSF/SSR key
SSF/SSR key
released
released
Braking factor = 200
Braking factor = 200
Braking factor = 0
Braking factor = 0
t
t
z ∆t = System cycle *
l
Example:
20ms * 200 = 4s
The unit will be stopped after ∆t = 4s!
Page: 14-58
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Modifying the braking factor is only possible in conjunction with a keydisc!
Accelerating factor (from a stop)
Put the key-disc in the control system floppy-drive.
] Press [F4] and then enter a value between 0 – 200 in order to delay the
acceleration
Vb
Vb
SSF/SSR key
SSF/SSR key
pressed
pressed
Acceleration = 200
Acceleration = 200
Acceleration = 0
Acceleration = 0
t
t
z ∆t = System cycle *
l
Example:
20ms * 200 = 4s
The unit will reach its maximum hand mode velocity after ∆t = 4s!
Modifying the accelerating factor is only possible in conjunction with a
key-disc!
]
Use the [F5] function key to change between the braking factor and
accelerating factor lines.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-59
VRS 1
300 - 349 Input / output constants
Hand-F2-F3
By using the I/O constants you can set how the inputs and outputs will be evaluated
and processed by the controller.
Entered here are:
• How many inputs and outputs the controller must process
• The relay assignments for the binary outputs
• In which format the sequence selection will be entered
• Which outputs to reserve for the gripper functions
• Which outputs should be static
• Which channels are responsible for the analog outputs
• From which components an PLC macro should be comprised
• The inter-bus input and output assignments
• etc.
]
The following screen will be displayed after selecting the [Hand] operating
mode and pressing the [F2] - [F3] function keys:
300..399:
I/O - constants
F1 = PLC I/O
F2 = System I/O
F3 = Analog outputs
F4 = PLC teaching macro
F5 = PLC counter
Input :
300..399
310..319
320..329
330..339
340..349
F1
F4
F2
F3
F5
The selection options for input /output constants 300 - 349 will be displayed.
The selection is made by:
1. Directly entering the constant number via the decimal key board or
2. Pressing [F1] - [F5] function keys
300 Allocating gripper
Hand-F2-F3-F1-F1
The controller differentiates between three different gripper functions:
Type 1 = Handling
Type 2 = Welding
Type 3 = Welding macro
Type 3 = Gripper sensor
Page: 14-60
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Up to 16 grippers can be processed (gripper-No. 1 - 16).
The gripper open/closed functions are executed via relays, which are controlled via the
programmable output commands Oopen or Oclosed.
When using welding gripper it is additionally required that the executed functions
GRIPPER ARE OPEN/CLOSED are sent to the controller as a status report. The input
commands Iopen or Iclosed are used for this.
In order to reduce the amount of programming for a complex welding process, the
relevant type 3 welding gripper-No. = can be assigned a welding macro.
This welding macro only has to be programmed once in the PLC. As agreed, the PLC
instructions for the complex welding process must be saved under macro-No. 0.
In order to start a welding program only the PLC instruction: macro 0 must be entered
in the respective TCP.
]
Select constant No. 300 an. The following screen will be displayed.
Module name:
No. Type Oopen Oclosed Iopen Iclosed
1
2
11
12
11
12
IBM module:
0
Position:
0
Module name:
No.+
No.-
F1
F2
DELETE
EDIT.
F3
F4
EDITOR
F5
If the gripper have not been entered the cursor will blink beneath the empty input field
for 'Type'. The remaining fields are also empty.
The following are displayed in this example:
No.:
gripper - No. 1
Type:
gripper - type 2 = welding gripper
Oopen:
ouput relay - No. 11 for gripper - OPEN
Oclosed:
ouput relay - No. 12 for gripper - CLOSED
Iopen:
input No. 11 for gripper open report
Iclosed:
input No. 12 for gripper closed report
IBM module: IBM module number
Position:
module position
Module name:module name
07.03.02
Elektroplanung-und Anlagenbau
Page:14-61
VRS 1
The function keys have the following functions:
F1 = gripper-No. +1
F2 = gripper-No. -1
F3 = delete the displayed allocation
F4 = correct the displayed gripper - types
F5 = gripper text editor
Gripper type allocation
If a gripper type has not been assigned, the cursor will blink beneath the type input
field:
No. Type Oopen Oclosed Iopen Iclosed
1
IBM module:
0
Position:
0
Module name:
No.+
No.-
F1
F2
DELETE
EDIT.
F3
F4
EDITOR
F5
The following screen will be displayed after the [F4] function key is pressed:
]
No. Type Oopen Oclosed Iopen Iclosed
1
IBM module:
0
Position:
0
Please enter a value and press RETURN
1 = HAND,2 = WELD, 3 = WELDING MACRO
No.+
No.DELETE
EDIT. EDITOR
F1
F2
F3
F4
F5
]
Enter the relevant gripper type.
]
Confirm the entry by pressing the [Return] key.
]
To allocate types to other gripper press the [F1] function key.
Displayed on the screen alongside the entered type will also be the automatically
assigned output relay number for the operation as well as the input numbers of the
same name for the relevant status report for this gripper-No. The default assignment of
the inputs and outputs for the functions [Gripper OPEN] or [Gripper CLOSED] or
[Gripper are OPEN] or [Gripper are CLOSED] can be corrected.
Page: 14-62
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Select the I/O - No. to be corrected using the [Cursor left] or
[Cursor right] keys.
]
Press the function key [F4] to make the correction.
]
Enter the new number of the input or outputs.
]
Confirm the entry by pressing the [Return] key.
Example: gripper - type 3 = welding macro
The use of welding macros offers the advantage that the run must only be programmed
once and then it can be repeated. This is done in the form of PLC instructions that are
saved under a specific macro-No. and can then be called up at any programmed point
within all of the existing sequences.
If gripper type 3 is entered for a gripper-No., the automatic assignment of the input
numbers for Iopen and Iclosed (status report) will not occur. Instead the code letter M
(macro) will be displayed under Iopen.
No. Type Oopen Oclosed Iopen Iclosed
1
IBM module:
0
Position:
0
Module name:
No.+
No.-
F1
F2
DELETE
EDIT.
F3
F4
EDITOR
F5
This means that when programming these gripper in a TCP the name 'Gripper' will not
be displayed as normal, but only the PLC macro and the associated macro-No., under
which the welding run using these gripper can be entered (edited).
The macro-Nos. (0 - 199) can be freely selected. If only one welding program is
available this will be saved under macro-No. 0.
Read the "PLC macros" section in chapter 9 "PLC Programming“ for further
information regarding this.
When editing welding macros it must be taken into consideration that the correct inputs
and outputs assigned to the respective gripper-No. are used.
Gripper 1
Gripper 2
Gripper 3
07.03.02
I11, I12
I13, I14
I15, I16
O11, O12
O13, O14
O15, O16 etc.
Elektroplanung-und Anlagenbau
Page:14-63
VRS 1
Example with PLC instructions for welding macros:
PLC program
Commentary
O11 = ON
Switch on gripper 1 OPEN relay
Wait for I11 & !I12
Wait for gripper 1 OPEN status report
and not CLOSED
O11 = OFF
Switch off gripper 1 OPEN relay
O12 = ON
Switch on gripper 1 CLOSED relay
Wait for !I11 & I12 &
I25
Wait until gripper 1 not OPEN and
status report gripper 1 CLOSED and
FK
O12 = OFF
Switch off gripper 1 CLOSED relay
O11 = ON
Switch on gripper 1 OPEN relay
Wait for I11 & !I12
Wait until gripper 1 OPEN status report
and not CLOSED
!
Take into account that O11 and O12 must be switched off, as they are pulse
valves and as must be controlled as such, otherwise there will be problems with
the dry run! Read chapter 9 "PLC Programming" for more information regarding
this.
The gripper text editor
This editor offers the possibility to replace (edit) the text displayed in gripper
information menu "Gripper No. xx open/closed" with an alphanumerical text entry.
This provides different individual assistance between the eight possible gripper
numbers and their functions, especially when a gripper function is set for controlling
another device; e.g. feeder cylinder Z12 FOR/BACK.
Page: 14-64
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The newly entered name is shown as a direct reference to the actual function.
Example:
Z1
A T T E N T I O N ! Gripper function
Gripper No. 1 open
ZNGclosed or F5 deletes the movement
open/cl
F1
F2
F3
F4
F5
Z1
A T T E N T I O N ! Gripper function
Feeder cylinder Z12 present
ZNGclosed or F5 deletes the movement
open/cl
F1
F2
F3
F4
F5
No. Type Oopen Oclosed Iopen Iclosed
1
IBM module:
0
Position:
0
Module name:
]
No.+
No.-
F1
F2
DELETE
EDIT.
F3
F4
EDITOR
F5
After selecting the required gripper-No. using [F1] or [F2] function keys, the
gripper text editor will be displayed after pressing the [F5] function key.
300:
Text editor for gripper No.1
Gripper No.1 open
Gripper No.1 closed
ABCDEFGHIJKLMNOPQRSTUVWXYZ ?!&().,;:/-<>
∧
Copy
Info
Return
Delete
Floppy
F1
07.03.02
F2
F3
F4
Elektroplanung-und Anlagenbau
F5
Page:14-65
VRS 1
Line 3 (11):
Line 4 (12):
Line 6 (14):
Line 7 (15):
Text line for gripper No. xx open
Text line for gripper No. xx closed
Display the available letters and special characters. Press the [Shift]
key (SHF) to switch over to small letters.
Information pointer (^) can be positioned beneath the letter or special
character to be edited by moving the joystick or by pressing the [Axis
traverse] keys (1V - 1R).
The numbers in brackets refer to the new hand console.
The function keys have the following assignments:
[F1] Return
Imports the letter/sign positioned beneath the pointer
[F2] Delete
Individual or all gripper texts
[F3] Floppy disc
Load the entire text from the floppy disc, save to floppy disc or verify
[F4] Copy
Copy the text entered text in lines 3 or 4 to another gripper-No.
[F5] Information
Short introduction to using the editor
A maximum of 40 letters or special characters can be entered per line. The cursor
blinks behind the displayed standard text.
Page: 14-66
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Use the [Cursor UP] and [Cursor DOWN] keys to position the cursor on the
required text line.
]
Use the [F2] function key or press the [Clr] key to clear the text line.
300 :
Text editor for gripper No.1
Gripper No.1 open
Gripper No.1 closed
ABCDEFGHIJKLMNOPQRSTUVWXYZ ?!&().,;:/-<>
∧
Copy
Info
Return
Clear
Floppy
F1
F2
F3
F4
F5
]
Move the information pointer beneath the required letter or special character
by turning the [Joystick] or by pressing the [Axis traverse] keys (1V - 1R).
]
Press the [F1] function key or the [Return] key. The required sign will be
displayed on the screen.
Z1
A T T E N T I O N ! Gripper function
Feeder cylinder Z12 present
ZNGclosed or F5 deletes the movement
open/cl
F1
F2
F3
F4
F5
This text will be displayed when the relevant gripper-No. is selected, if the [Gripper
OPEN] or [Gripper CLOSED] keys are pressed.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-67
VRS 1
[F4] Copying
With this copying function, the editing of the same or similar text is considerably
simplified. If, for example, the "Feeder cylinder Z12 present" text in line 3 must be
edited, the same gripper No. can be copied from line 4 or after modifying the gripperNo. there in line 3 it can be copied and slightly updated afterwards.
Example: Cursor blinks on the previously edited text line
300 :
Text editor for gripper No.1
Gripper No.1 FEEDER CYLINDER Z12 PRESENT
Gripper No.1
ABCDEFGHIJKLMNOPQRSTUVWXYZ ?!&().,;:/-<>
∧
Copy
Info
Return
Delete Floppy
F1
]
F2
F3
F4
F5
Press the function key [F4]. On the screen the line 7 (14) is added for the
displaying of the text to be copied as well as the requirement to enter the
destination where the text must be copied.
300 :
Text editor for gripper No.1
Gripper No.1 FEEDER CYLINDER Z12 PRESENT
Gripper No.1
Copy : ( select destination, then press Return )
Gripper No.1
FEEDER CYLINDER Z12
F1
F2
F3
F4
F5
]
Use the [Cursor] keys to move the blinking cursor to the relevant text line, or
]
Use [Gripper+] or [Gripper-] keys to select a gripper-No.
]
Position the cursor on the required text line.
]
Confirm the entry by pressing the [Return] key. The edited text will be copied
to the selected text line.
Page: 14-68
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
301 Output attributes
Hand-F2-F3-F1-F2
With the newly processed, adjustable output attributes it is now possible for the
operator to control the contents of the static outputs in the PLC much more than
previously.
Modifying the output attributes is only possible in conjunction with a
key disc!
]
The following text will be displayed after selecting constant No. 301:
Following outputs deviate from the
standard settings
F1 = Edit, ESC = Abort
F1
F2
F3
F4
F5
In example 1, the status of the output at the end of the sequence (static or non-static),
which is the new output attribute, is displayed alongside the output number (1-128).
With this you now have the option to program the default status of the relevant outputs
when the dry run is switched off. The contents of the output for drive system OFF and
Single-Step reverse can be defined with 0 or 1 or the existing status can be retained.
Furthermore you have the option to pulse the outputs for controlling pulse valves. The
setting of the pulse duration is realised in cycle increments (15 ms increments) and can
be set in the 2 - 255 cycles range.
Example 1:
Output number (1-128)
Non-stat. = 0 ; stat. = 1
Dry run (No, Yes)
Start if dry run off
Contents withidrive OFF
SSR contents
Pulse duration (1=const, 2 - 255)
F1
F2
F3
:
:
:
:
:
:
:
F4
1
non-stat.
Yes
retain
0
const.
F5
The default output attribute refers to the previous functionality of the output contents.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-69
VRS 1
Condition
Use shift right or left to scroll the output number with the associated output attributes.
Use UP and DOWN to select the individual attribute. The selection options are
displayed in the bottom line of the screen.
Dependencies
Dependencies exist between the static attributes and constant outputs (non-pulsed)
and the dry run attributes = Yes and start status, when no dry run = -.
Compatibility
Updating compatibility with previously available VRS controllers exists. If old constants
are loaded in the new version, the status of the output attributes will be updated at the
end of a sequence and the new attribute with the pre-set default status will be loaded.
302 Defining static flags
Hand-F2-F3-F1-F3
Flags correspond to the so-called marker characters in the PLC, which can only have
the logical 0 or 1 state (0 = not set, 1 = set).
A maximum number of 999 flags (F1 - F999) can be programmed, i.e. set, deleted or
interrogated regarding the current status. As opposed to normal flags, flags defined as
static contain their logical status even after the end of the sequence or after a
sequence change (analogous to static outputs). This option is used for operations with
sequence changes, when stacking using variable controls etc.
Prior to programming the flags it is sensible to sub-divide the flags (a maximum of 999
flags is possible) into two areas:
non-static flags
• Start area =
static flags
• End area =
The sub-division is always shown in sub-sections of 8 Flags, which by entering a
relevant flag-No. as non-static is sub-divided from the remaining static flag areas.
Example:
Enter: 77,
from the next block of 8, all flags (81 - 999) will be static
77
0
n o n sta tic
Page: 14-70
sta tic
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Entry:
0
=
77
=
1
=
]
flags
flags
flags
1 - 999 are non-static
1 - 80 are non-static
1 - 999 are static
Select constant No. 302. The following screen will be displayed.
302 :
Static flags
The following flags are static :
None
Input :
F1
(0 - 999)
F2
F3
F4
F5
Groups that have been defined will be displayed as static flags.
] Entering a relevant flag-No can move the range of the static flags.
]
Confirm the entry by pressing the [Return] key.
303 Selective setting/clearing of flags (editing)
Hand-F2-F3-F1-F4
Advantages of the selective setting / deleting are:
• Resetting of the flags that were defined as 'static'
• Simulation of operating statuses that can be interrogated via the flags
• Resetting flags that were set in the [Automatic] or [Single Step] operating
modes
• Updating of stack position numbers etc.
A maximum of 999 Flags (F1 - F999) can be selectively set or cleared.
If a flag is selectively set (logical 1), it will retain this state until it is selectively cleared
again!
If a flag is selectively cleared (logical 0), it will retain this state until it is selectively set
again!
The 'static' definition will also be removed from the flag!
07.03.02
Elektroplanung-und Anlagenbau
Page:14-71
VRS 1
]
Select constant No. 303 an. The following screen will be displayed.
303 :
Edit Flags
F1 - F32
0000 0000 0000 0000 0000 0000 0000 0000
∧
F1
Input : F
SET
RESET
F1
F2
F3
F4
F5
Flag-No. F 1 has been entered in this example. The current statuses of 32 flags (1 - 32,
33 - 64, 65 - 96 etc.) will be displayed.
]
Enter the required flag-No.
]
Confirm the entry by pressing the [Return] key.
The relevant group of flags will be displayed. In addition, the position of the entered
flag-No. will be indicated.
]
Use [F1] or [F2] function keys to now set the selected flag to '1' (SET) or '0'
(RESET).
304 Entering the binary output format
Hand-F2-F3-F1-F5
The binary outputs will be indicated in the controller at the same time as the outputs for
various relays are indicated (maximum of 16 relays at the same time!).
Read the "PLC binary outputs" section in chapter 9 "PLC Programming" for
further information regarding this.
The system makes 992 outputs free for use, from which a maximum of 16 consecutive
outputs (+1 parity output) can be freely selected for the binary output. The controller
then controls the corresponding relays after the decimal number has been converted
into the relevant binary code.
Page: 14-72
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Number of outputs:
Up to 16 binary outputs (b0 - b15) using different formats can be set.
ATTENTION!
b15 occupies a special position. The current sequence number will always be
created from this binary output. If this function is required, the starting point (bit
number), the binary output width (normally 7 (without parity) or 8 bits (with
parity)) and the parity format must be set-up in “Modify constants”. There are
only two possible states for the binary output b15 in the PLC:
b15 = 0;
this resets the sequence reverse mirroring to zero;
b15 = 1;
this activates the sequence reverse mirroring.
b15 then includes the current sequence number.
!
]
Select constant No. 304. The following screen will be displayed.
304 :
Binary output format
Size output
Start output
Parity
Parity
F1
0
0
Binary+
F2
:
:
:
0
0
----
Binary-
F3
F4
F5
]
Use [F2] or [F3] function keys to select the required output-No. (0 -9).
]
Enter the number of the consecutive relay outputs in the "width" field.
]
Enter the first position of the binary outputs (relay group) from the 16 relays on
the I/O board in the "Start" field (start = 1 from O1, start = 6 from O6 etc.). If
start = 0 or width = 0 there will be no output!
]
Enter the allocation of the control relay in the "Parity" field, which is always the
next relay in this relay group and the number of outputs to be set to even /
odd.
]
The following will be displayed after repeated pressing of the [F1] function
key:
• EVEN
to be made up to an even number
• ODD
to be made up to an odd number
• ---No parity output
07.03.02
Elektroplanung-und Anlagenbau
Page:14-73
VRS 1
Example:
10iteWidth
1 rity:
Parity:
1 . Bin ä1.raBinary
u sg a b output
e -W e rtsignificance
ig ke it 1 0 Bre
4 Sta4 rt:Start:
1
Pa
EV ENEVEN
(G e ra d e )
10 = significance
8 g+ ke
2 it=8 +A22 + A4
1 0 = W e rti
= A2 + A4
A1
A3
A4
1
2
4
WSignificance
e rtig ke it
A2
8
A5
A6
A7
A8
A9
A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20 A21 A22 A23 A24
Pa
rity
Parity
305 Defining the static outputs
Hand-F2-F3-F1-F5-F2
A maximum of 992 outputs (A1 - A992) can be programmed, i.e. can be polled
regarding the current status. As opposed to normal outputs, they keep their status as
statically defined outputs even at the end of a sequence end or during a sequence
change. This option is used when operating with sequence changes.
Example:
Entry: 77,
]
output 77 will now become static
Select constant No. 305. The following menu will be displayed.
305
300:
Static outputs
Defined outputs :
Enter O-No:
+ = set - = delete
F1
F2
(1 - 992)
Continue
F3
F4
F5
]
Enter the required O-No.
]
Confirm the entry by pressing the [Return] key and the following menu will be
displayed:
305
300:
Static outputs
Defined outputs :
77
Enter O-No:
+ = set - = delete
F1
F2
(1 - 992)
Continue
F3
F4
F5
O-No. 77 was entered in this example. The corresponding output will be displayed.
Page: 14-74
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Hand-F2-F3-F1-F5-F3
306 Displaying a point number on a counter
Use this constant to display point numbers from a sequence or a sub-program on a
counter, e.g. the BMS can be told in which tool centre point the robot is located.
] Select constant No. 306. The following menu will be displayed:
306
300: Displaying the point number on a counter
bbild
Minimum:
Default :
1
0
Maximum:
Abort with ESC
Enter:
F1
15
(1- 15)
F2
F3
F4
F5
]
The [F1] function key can be used to select a counter between 1 and 15,
which will display the current point number after being called up in [SingleStep] or [Automatic].
]
Press [ESC] to exit this menu
Hand-F2-F3-F1-F5-F4
307 Displaying a velocity on a counter
With this constant you have the option to display a velocity setting (override) on a
counter for comparison purposes. The counter will be updated after each operating
mode change.
!
ATTENTION! It is not possible to reset the velocity from a sequence/SP to
a higher or lower profile here!
]
Select constant No. 307. The following menu will be displayed:
307
300: Displaying the velocity on a counter
Minimum:
Default:
1
0
Maximum:
Abort with ESC
Enter:
F1
F2
15
(1 - 15)
F3
F4
F5
]
The [F1] function key can be used to select a counter between 1 and 15,
which will display the velocity setting after being called up in [Single-Step] or
[Automatic].
]
Press [ESC] to exit this menu.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-75
VRS 1
310 ... 319 SYSTEM I / O
Hand-F2-F3-F2
]
There are four methods of updating, which results in different menus being
used. These are:
]
Sequence selection via the physical I/O card to 5E-1428
]
Sequence selection via the interbus slave card to 5E-1432 (Cu)
]
Sequence selection via the interbus slave card to 5E-563 (LWL)
]
Sequence selection via the interbus master/slave card to 5E-1494 (without
SUPI3-OPC) or 5E-1528 (with SUPI3-OPC)
]
If using the hardware configurations from points 1 – 3 and selecting the
[Hand] operating mode, press one of [F2], [F3] and [F2] function keys and the
following text will be displayed:
310..319 : SYSTEM – I/O
F1 = Sequence selection
F2 = Number of input ports
F3 = Number of output ports
F5 = Continue
Input:
F1
F2
310
311
312
313 .. 316
F3
F4
F5
]
After entering the constant number or pressing the relevant [F1] - [F5] function
key the respective I/O function will be displayed.
]
If using the hardware configuration from point 4 and selecting the [Hand]
operating mode, press one of the [F2], [F3] and [F2] function keys and the
following text will be displayed:
310..315,
350..354 : SYSTEM – I/O
300
F1 = Sequence selection
310
F2 = Number of input ports
311
F3 = Number of output ports
312
F4= SYS I/O -> Flags
315
F5 = Continue
350 . . 354
Input :
F1
]
F2
F3
F4
F5
After entering the constant number or pressing the relevant [F1] - [F5] function
key the respective I/O function will be displayed.
Selecting via the I/O card and the interbus master/slave card is described in the
following sections.
Page: 14-76
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
310 Sequence selection (binary/1 from n)
Hand-F2-F3-F2-F1
General information
The controller must be told which programmed working sequence the robot must run.
As the controller can process a maximum of 127 different sequences, this will also
require 127 inputs. This is carried out using fixed inputs. 8 bits (1 byte) are reserved for
the selection.
Sequence selection is activated by providing 24 volts to the input card or sending a
fibre optic signal to the interbus card and selecting a query byte.
Sequence selection 1 FROM N
With the 1 FROM N sequence selection, only sequence 1 - 8 can be selected when the
inputs 1 - 8 have been set.
Example:
Sequence 1
Sequence 2
Sequence 3
Sequence 8
=
=
=
=
set I1 or
set I2 or
set I3 or
set I8
If the sequence selection is entered from 1 from n, the controller will check to see if
only 1 input is set. Otherwise an error report will follow!
07.03.02
Elektroplanung-und Anlagenbau
Page:14-77
VRS 1
Binary sequence selection
In order to be able to select all 127 sequences, the SEQUENCE- No. can be selected
by setting several inputs at the same time.
SteController
u e ru n g
E1
E1 6
A1
A16
O pOpto-coupler
to ko p p le r
1 2 3 4 5
E1
6 7
8 N1
9 10 11 12 13 14 15 16 N 2
external
2 4 V Fre mvoltage
d sp a n24
nuVn g
1 2
E1 6
1 2
31 32
A 1 potential
p o te n tifree
a lfre(2A)
i(2 A )
A16
8 9
32
for
Füar mmax.
a x. 1of2 7127
Fo ls.
gen
free
•
Fre ifü
r Pefor
rip hperipheral
e rie e in g a input
n g sko m a n d o s
d
EinInputs
g ä ng e
E1
E8
rerezerv.
se rvie rt
1
8
fü
r
m
a
x.
1
2
7
Fo
l
g
e
n
for a max. of 127 s.
Inputs
Ei
ng ä ng e
E1 E2
W e rtizg keSit: 1
2
E3 E4
E5
E6 E7
4
16
Parity
3 2 6 4 Pa
rity
8
E8
In the binary display each of the 7 (+1) inputs has a so-called significance.
By the adding the relevant significances (they set the associated inputs) together all of
the sequences (1 - 127) can now be selected.
Page: 14-78
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Example:
Sequence 3
Sequence 9
Sequence 10
Sequence 16
Sequence 64
Sequence 67
Sequence 127
=
=
=
=
=
=
=
set I1 + I2
set I4 + I1
set I4 + I2
set I5 + parity
set I7 + parity
set I7 + I2 + I1 + parity
set I1 + I2 + I3 + I4 + I5 + I6 + I7 + parity
For safety reasons the number of set inputs must be made the same as input I8 with
the even parity.
!
Note:
The setting of even parity in conjunction with the interbus master/slave card is
not necessary, as the data transfer will be controlled via the hardware (CRC).
With I / O card and/or interbus slave card:
]
The following text will be displayed after constant No. 310 has been selected.
310 :
Sequence selection
Default:
1 FROM N
I1 to I8
Press ESC to abort
Input :
Binary 1 FROM N
F1
F2
F3
I+
I-
F4
F5
]
Press the [F1] function key to change the default setting to binary or press the
e [F2] function key to change the default setting to 1 FROM N
]
Press the [F4] function key to move the sequence selection up to the next
highest 8 inputs. The sequence selection will then change, e.g. from inputs I1
to I8 up to inputs I9 to I16.
]
Press the [F5] function key to move the sequence setting down to the next
lowest inputs. The sequence selection will then change, e.g. from inputs I9 to
I16 down to I1 to I8.
The binary sequence selection it also dependent on the byte address setting here, i.e.
the significance is interpreted from these inputs.
As a result of these settings, each sequence-No. entry will now be interpreted either as
an integer (1 from N) or as a binary value.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-79
VRS 1
With the inter-bus Master / Slave card:
] The following text will be displayed after constant No. 310 has been selected.
310 :
300
Sequence selection
Default setting: 1 FROM N
Sequence number at byte :
BMS interface byte, + / - = on / off:
VW diagn. At byte, + / - = on / off:
Enter :
Continue
Binary VW-diag BMS-byte
F1
]
F2
F3
F4
16
16
26
Sequence
F5
Press the [F1] function key in order to edit the inter-bus master system bits.
The following menu is then displayed:
310
300:
IBM system bits
IBM AUTO
IBM SSTEP
IBM HAND
IBM Fstart
Enter :
Continue AUTO
F1
F2
at bit, + / - = on / off O: 140
at bit, + / - = on / off O: 139
at bit, + / - = on / off O: 138
at bit, + / - = on / off I: 137
SSTEP
F3
HAND
FSTART
F4
F5
IBM AUTO, IBM SSTEP, IBM HAND: These three bits produce the current operating
mode for the robot controller. Each of these bits can be mapped to any I/O address. If
these bits are not required, the output can be inhibited by entering a negative bit
number.
IBM Fstart: This bit determines, which bit – address the “Sequence start” controller
must read.
] Press the [F1] function key to jump to the next interbus master menu. The
following menu is then displayed:
310
300:
IBM system bits
IBM READY
at bit, + / - = on / off A: 137
IBM RUN
at bit, + / - = on / off A: OFF
IBM WPROZ
at bit, + / - = on / off A: 142
IBM WSLAV
at bit, + / - = on / off A: 143
Enter:
Continue
READY
RUN
WPROZ WSLAV
F1
Page: 14-80
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
IBM READY: This bit passes the internal status onto the controller and signifies that
the system is “Ready for operation”. As soon as an internal error occurs, the bit is reset
to “zero”. External events such as waiting for a contact, EMERGENCY-OFF or safety
guard opened do not affect this bit, it is just that a non-permitted status has occurred
(automatic mode with activated “E2” termination).
IBM RUN: This bit passes on the status of the interbus master. If the interbus master is
in “RUN” mode, then this bit is set to “1”. If a bus failure occurs, this bit is reset to “0”.
This bit can only be meaningfully used in conjunction with the onboard slave and is
therefore used as a diagnostic report.
IBM WPROZ: If the robot controller is waiting for a contact which lies in the master I/O
sector, this bit is set to “1”.
IBM WSLAV: If the robot controller is waiting for a contact which lies in the slave I/O
sector, this bit is set to “1”.
]
Use the [F1] function key to jump to the next inter-bus master menu. The
following menu is then displayed:
310
300:
IBM system bits
IBM RK100
IBM DRIVE on
IBM WARN
at
bit, + / - = on / off
bit, + / - = on / off
bit, + / - = on / off
Enter :
Continue
RK100
DRIVE
WARN
F1
F2
F3
F4
O: 141
I: 140
O: 144
F5
]
IBM RK100: This bit passes the “Drive” status on to the robot. If the drive
system is switched on, a “1” will be generated by this bit.
]
IBM Drive on: This bit is an input, which can switch on the robot drive system
via the interbus.
]
IBM Warn: This bit generates a “1”, if the permitted error quota on the interbus
/ master / transfer path is exceeded. In this case, the master bus does not in
fact exit the “RUN” mode, however the data transfer on the master bus can no
longer be guaranteed to be error-free.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-81
VRS 1
]
Press the [F1] function key to jump back to the output menu:
310 :
300
Sequqence selection
Default setting: 1 FROM N
Sequence number at byte :
BMS interface byte, + / - = on / off:
VW diagnose at byte, + / - = on / off:
Enter:
Continue
Binary VW-diag BMS-byte
F1
F2
F3
16
16
26
Sequence
select.
F4
F5
]
Press the [F2] function key to change the default setting to Binary or 1 FROM
N.
]
Press the [F3] function key to change the VW-diagnose default setting.
]
This diagnostic value can be assigned to any byte address in the interbus I/O
sector. If this output is not required, it can be switched out by entering a
negative byte number in the diagnose output.
]
Press the [F4] function key to change the default setting for the BMSinterface.
The byte number must be entered here, as this sets the input and output bytes for the
BMS (operating materials controller). In normal cases this byte should be set so that it
is the same as the start address of the slave, as the robot controller communicates with
the BMS via its slave in normal operation. Another possible path is via an interbus
gateway. In this case the BMS byte must be in the in the master I/O sector. The BMS
interface can be inhibited by entering a negative value.
Page: 14-82
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The following assignments are being used at the moment:
Name
Sequence number at bit
BMS interface at bit
VW diagnose at bit
IBM AUTO at bit
IBM SSTEP at bit
IBM HAND at bit
IBM FStrt at bit
IBM READY at bit
IBM RUN at bit
IBM WPROZ at bit
IBM WSLAV at bit
IBM RK100 at bit
IBM DRIVE at bit
IBM WARN at bit
!
VW
16
17
26
140
139
138
137
137
OFF
142
143
141
140
144
AUDI
104
105
102
844
843
OFF
841
841
842
846
847
845
842
OFF
Important information:
These address assignments are examples only!
07.03.02
Elektroplanung-und Anlagenbau
Page:14-83
VRS 1
311 Number of PLC-inputs
Hand-F2-F3-F2-F2
A maximum of 128 inputs can be used in the controller. From these 8 inputs are
reserved for the sequence selection. The standard construction level covers 16 inputs
(1 I/O board). If extensions are used, the new inputs can be enabled for use. Modifying
the number of pre-entered inputs does this.
] The following screen will be displayed after selecting constant No. 311 the
following text will be displayed:
311 :
Number of inputs
Minimum :
Default :
0
Maximum : 128
(8 + 120)
32
Press ESC to abort
Input :
F1
F2
F3
F4
F5
The default number of inputs will be displayed.
] If you wish to modify the default setting by expanding the I/O, you must enter
the relevant number of inputs.
]
Confirm the entry by pressing the [Return] key. The entered number will be
displayed as the new default setting.
If a wrong number has been entered, e.g. greater than 128, then the entry will be
ignored and the cursor will blink beneath the input field. If the number entered for the
inputs is greater than 16, regardless if only 1 I/O board has been fitted, the following
error report will be displayed:
Error when MODIFYING CONSTANTS
Too many inputs !
Acknowledge using ESC / MOS :
F1
F2
F3
F4
F5
]
A wrong entry can be cleared using the [Clr] key.
]
Use the [Cursor] keys to position the cursor on the input field containing the
wrong entry and then the entry can be corrected.
]
Use the [Esc] to interrupt the entry. In this case the old pre-setting will be
retained and the cursor will blink beneath the wrong value.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen.
Page: 14-84
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
312 Number of PLC-outputs
Hand-F2-F3-F2-F3
A maximum of 128 outputs (O1 - O128) can be used in the controller. The standard
construction level covers 16 outputs (1 I/O board). If extensions are used, the new
outputs can be enabled for use. Modifying the number of pre-entered outputs does this.
] The following screen will be displayed after selecting constant No. 312 the
following text will be displayed:
312 :
Number of outputs
Minimum :
Default :
0
Press ESC to abort
Input :
F1
Maximum : 96
32
F2
(0 - 96)
F3
F4
F5
The default number of outputs will be displayed.
]
If you wish to modify the number of PLC inputs, you must enter the relevant
number. If a wrong number has been entered, e.g. greater than 128, then the
entry will be ignored and the cursor will blink beneath the input field. If the
number entered for the inputs is greater than 16, regardless if only 1 I/O board
has been fitted, the following error report will be displayed:
Error when MODIFYING CONSTANTS
Too many outputs !
Acknowledge using ESC / MOS :
F1
F2
F3
F4
F5
]
A wrong entry can be cleared using the [Clr] key.
]
Use the [Cursor] keys to position the cursor on the input field containing the
wrong entry and then the entry can be corrected.
]
Use the [Esc] to interrupt the entry. In this case the old pre-setting will be
retained and the cursor will blink beneath the wrong value.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed on the screen.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-85
VRS 1
313 Inter-bus outputs
Hand-F2-F3-F2-F4
The inter-bus interface is a serial I/O - bus working in conjunction with an PLC. The
controller can be connected to this bus as a slave (bus-terminal) via a special inter-bus
interface board. The inter-bus board functions via 64 inputs and outputs and can
operate in any controller (at the moment there is a maximum of 2 boards per
controller).
This cannot operate as a self-standing I/O - board. It must have at least one additional
standard I/O board available in the system as well.
The relevant entries for the 64 inter-bus board outputs (O1 - O64) can be selected for
linking with the following input or outputs of the robot I/O boards under these constant
numbers:
Robot inputs
System inputs
Robot outputs
System outputs
I1
IS1
O1
OS1
-
I128
IS16
O128
OS16
The following is to be taken into consideration:
• Each inter-bus signal can only be linked once.
• When an inter-bus bit is set to a robot input that is also set to a standard
input, the inter-bus input will have the highest priority. The standard input will
have no further function.
• The inter-bus assignment will be saved together with the robot constants.
They can also be saved to floppy disc and read in again at any time.
• The inter-bus outputs can be switched between active and passive.
]
The following screen will be displayed after selecting the constant No. 313
the following text will be displayed:
313 :INTER-BUS O – ROBOT I/O
O 1 = --O
2=
--O 3 = OS 14
O
4=
--O 5 = --O
6 = I128
O 7 = --O
8=
--O 9 = --O 10 =
--1st board 2nd board
F1
F2
* OFF **
1st board
* OFF **
2nd board
* OFF **
I/O/S
ON/OFF
FLOPPY
F3
F4
F5
In this example inter-bus output O3 has been linked to robot system output OS 14 as
well as inter-bus output O6 being linked to robot input I128.
[F1] 1st board and
[F2] 2nd board
by pressing these function keys it is possible to set or switch off the data transfer
mode according to the system configuration.
[F3] I/O/S
Identifier for the entered input or output-Nos. for robot I/O.
Page: 14-86
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
[F4] ON/OFF
Switch inter-bus outputs between ACTIVE/PASSIVE
[F5] FLOPPY DISC
Save inter-bus data to a floppy disc, read in from a floppy disc and verify
[SHF] + [Cursor] keys
Use these function keys to page forwards or backwards.
Intezrb Inter-bus
u s-Ka rte
Ro zb o Robot
te r I/O I/O
Robot
Ro b o te rinputs
e in g ä n g e
Robot
Ro b o te routputs
a u sg ä n g e
E 128
A 1
A 2
A 3
A 1
A 64
E1
A 33
A 34
A 35
A 128
SE 1
Syste m e in g ä n g e
SE 1 6
System
Syste m outputs
SA 1
a u sg ä n g e
AOutputs
u sg ä n g e
SA 1 6
D ie Izn te rThe
b u s-Ainter-bus
u sg ä n g eoutputs can be AA1
1 --A A64
64
kö n nze n combined
ko m b in ie rtwith
w e rdthe
e n robot
m it d eI/O
n
R o b o te rinputs
I/O Ein g ä n g e n
E1
28
E1--E1E128
SE1 -- SE1
6
z
SE1
SE16
o d e rz A uor
sg outputs
ä ngen
A 1 -- AA128
128
A1
SA 1 -- SA
16
z
Sa1
SA16
Ko
n fig ura tio n smmenu
e n üfor
fü rinter-bus
Inte rb u s-S
Configuration
interf.
Woptional
a h lfre ieinter-bus
Zu o rd nuoutput
n g In teassignments
rb u s-A u sg ä n g e
314 Inter-bus inputs
Hand-F2-F3-F2-F5
The inter-bus interface is a serial I/O - bus working in conjunction with an PLC. The
controller can be connected to this bus as a slave (bus-terminal) via a special inter-bus
interface board.
The inter-bus board functions via 64 inputs and outputs and can operate in any
controller (at the moment there is a maximum of 2 boards per controller).
This board cannot operate as a standalone I/O board. There must be at least one
standard I/O board available in the system as well.
The relevant entries for the 64 inter-bus board inputs (I1 - I64) can be selected for
linking with the following input or outputs of the robot I/O boards under these constant
numbers:
Robot inputs
System inputs
I1
IS1
- I128
- IS16
The following must be taken into consideration:
• Each inter-bus signal can only be linked (assigned) once.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-87
VRS 1
• When an inter-bus bit is set to a robot input that is also set to a standard
input, the inter-bus input will have the highest priority. The standard input will
have no further function.
• The inter-bus assignment will be saved together with the robot constants.
They can also be saved to floppy disc and read in again at any time.
• The inter-bus inputs can be switched between active and passive.
]
The following screen will be displayed after selecting constant No. 314. The
following text will be displayed:
313 :INTER-BUS I – ROBOT I/O
I
1 = --I
2 = --I
3 = IS 14
I
4=
--I
5 = --I
6 = I128
I
7 = --i
8=
--I
9 = --I
10 =
--1st board 2nd board
F1
F2
* OFF **
1st board
* OFF **
2nd board
* OFF **
I/O/S
ON/OFF
FLOPPY
F3
F4
F5
In this example inter-bus input I3 is linked to robot system input IS 14 as well as interbus input I6 being linked to robot input I128.
[F1] 1st board and
[F2] 2nd board
By pressing these function keys it is possible to set or switch off the data transfer
mode according to the system configuration.
[F3] I/S
Identifies the entered input-Nos. for robot I/O (I, IS)
[F4] ON/OFF
Switches inter-bus inputs between ACTIVE/PASSIVE
[F5] FLOPPY
Save inter-bus data to a floppy disc, read in from a floppy disc and verify.
Page: 14-88
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Robot
Ro bz o te
r I/O I/O
Ro b o te re in g ä n g e
Robot
Ro
b o te raoutputs
u sg ä n g e
Inter-bus
board
Inte rb u s-Ka
rte
E 128
A 1
A 2
A 3
A 1
A 64
E1
A uOutputs
sg ä n g e
A 33
A 34
A 35
A 128
SE 1
Syste
m System
einputs
in g ä n g e
SE 1 6
SA 1
Syste m a u sg ä n g e
SA 1 6
inter-bus
D ie Izn te rThe
b u s-A
u sg ä n g eoutputs can be AA1
1 --AA64
64
kö n nze n combined
n u r ko m b inwith
ie rt wthe
e rdrobot
e n m I/O
it d e n
R o b o te rinputs
I/O Ein g ä n g e n
E1
28
E1--E1E128
o d e zr or outputs
SE1 -- SE1
6
SE1
SE16
Configuration
interf.
Ko
n fig ura tio n menu
sm e n üforfüinter-bus
r Inte rb u s-S
assignments
Woptional
a h lfre ieinter-bus
Zu o rd nuoutput
n g In te
rb u s-A u sg ä n g e
315 SYS I/O displayed with FLAGS
Hand-F3-F2-F5-F3
In the VRS1-PLC the flags correspond to the so-called marker characters that can only
be set to 0 or 1 logical state.
The advantage of the >flags, is that conditions that only occur once can be
permanently: e.g. cycle control, stacking position occupied or system inputs as well.
A maximum of 999 flags can be programmed.
The following must be taken into consideration with sequences:
• A flag cannot be used for another marker, so long as it is still ON.
• Whether the flag being used has been defined as static and consequently always
retains the logical mark status at the end of the sequence.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-89
VRS 1
The following system inputs can be displayed with flags in the VRS1-controller:
IS 1
IS 2
IS 3
IS 4
IS 5
IS 6
IS 8
IS 10
IS 11
IS 12
IS 13
IS 15
IS 16
IS 17 a
IS 17 b
IS 18
IS 19
IS 20
IS 21
IS 22
IS 23
IS 24
Wait 1
Select Automatic
Select Hand
Select Single-Step
Wait 2
Drive system on
Start sequence
Control O.K.
Process velocity for Single-Step
Protection lattice linked out
Protection circuit O.K.
Ramp braking
Acknowledge HP diagnostics
Emergency Off a
Emergency Off b
Start sequence
Drive system On
Drive system Off
Reserved for enhancements
Reserved for enhancements
Reserved for enhancements
Reserved for enhancements
Modifying the output attributes is only possible in conjunction with a
key disc!
Page: 14-90
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
] Place the key disc in the controller disc drive.
] Select constant No. 315. The following screen will be displayed:
315 :
SYS I/O copy to flags
Flag number :
Adjusting :
]
]
969
Disable
Number
Enable
F1
F2
F3
F4
F5
By entering a flag number, all the above listed system inputs will be mapped to
the following flags from this flag number. It is then available for further
processing, e.g. used in the free running PLC.
Use the [F2] function key to enable or disable the flags.
Example:
If, for example, the flag number 1 is entered, all the 22 system inputs will now be
set to the following flags from flag 1 onwards.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-91
VRS 1
320 Assigning the analog output channels
HAND-F2-F3-F3-F1
Up to 16 analog outputs can be outputted simultaneously by the controller. These can
be: a pre-selected constant DC voltage or a DC voltage proportional to the traversed
velocity (VTCP).
Before you can output an analog voltage the relevant analog output channels must be
defined. This will allocate fixed physical analog outputs to the analog output channels.
In order to differentiate between which D/A - output is responsible for which of the 16
analog voltage outputs, these must be passed out via the so-called output channels
(channels 1 - 16).
Controller
Analog
output set
No. 1
Analog
output set
No. 2
Analog
output set
No. 3
Analog
output set
No. 4
Analog
output set
No. 16
Freely selectable assignment
in each TCP
Channel 1
Channel 2
Channel 3
Channel 4
Channel 16
Freely selectable assign.
via const. 320
z
I/O board 1
I/O board 2
Output example
VVVV-
anal. Vtcp
constant
constant
anal. Vtcp
Should an analog output occur in a TCP, only the relevant channel No. has to be
programmed.
Page: 14-92
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
The following screen will be displayed after selecting the [Hand] operating
mode and the following menu will be displayed after pressing the [F2], [F3]
and [F3] function keys:
320 .. 329 : Analog outputs
F1 =
Channel assignment 1 - 8
F2 =
Attribute for analog output
320
321
Input :
F1
]
F2
F3
F4
F5
The following menu will be displayed after pressing the [F1] function key or
entering the number 320:
320 :
Allocating analog channels
Channel 1 : DA -Channel 5 :
Channel 2 : DA -Channel 6 :
Channel 3 : DA -Channel 7 :
Channel 4 : DA -Channel 8 :
Press ESC to abort
Input channel No. : 1 =
Lochan+ Lochan- Delete
F1
F2
F3
DA -DA -DA -DA --
F4
F5
[F1]
Channel+
the displayed channel No. will be increased by 1
[F2]
Channelthe displayed channel No. will be decreased by 1
[F3]
Delete
When a D/A output No. has to be deleted, you must first use F1 or F2 to set
up the respective channel No.
[F4]
DO/IB0/IB1
Use this function key to change between DO, IB0 and IB1.
The difference between them is that DO is used to describe a digital output,
IB0 is used to describe the data format for ST-module and IB1 is used to
describe the data format for IL-module.
[F5]
Edit
Press this function key to be able to modify the DO output-No. or the interbus
master address.
All analog outputs can now be mapped to the new interbus master card as well. It is
still possible to access the analog outputs via the physical DA channels that are
integrated in the control system as before. If required, the analog output a(n) (n = 0 to
15) can be assigned to an interbus master target address (IBM) in “Modify constants”.
!
ATTENTION! The target address must be an even number and divisible by
two. The address assignments are freely selectable in the 0 to 160 sectors.
As addresses 0 to 127 are reserved for the I/O sector, we recommend
using the IBM - addresses 128 to 160 for the analog outputs.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-93
VRS 1
The following Phoenix 16 bit output format is used for an analog output via the interbus
(for master/slave only):
For ST-module (IB0):
MSB
SN
0
LSB
14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Volts
1
1
0
0
0
1
0
0
0
0
0
1
X
X
X
7.66V
1
1
1
X = reserved
0
0
0
1
0
0
0
0
0
1
X
X
X
-7.66V
For IL-module (IB1):
MSB
LSB
15
14 13 12 11 10
9
8
7
6
5
4
3
2
1
SN
Volts
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
9.99 V
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
-9.99V
These tables show two examples of a DO output going to a Phoenix DO module via the
interbus. The uppermost / lowermost bits are reserved for the sign (SN) in Phoenix DOoutput format. DO-modules that only have positive output voltages will ignore this bit,
so that if there is a negative digital DO value at the module’s analog output, only the
voltage value will be outputted. The outputted voltage will be adjusted to that of the
level of the internal reference for the analog module. This reference voltage is normally
rated at 10 volts.
This produces the following unit values for the interbus DO-module being used:
Interbus DO module
model
8 bit analog module
12 bit analog module
Reference voltage
Voltage / bit
10 Volt
10 Volt
39.216 mV / bit
2.441 mV / bit
As the analog output size in the VRS controller is programmed in mV, the conversion of
the relevant digital output sizes is carried out by the controller. However, please note
that the actual analog output voltage is quantified, i.e. the analog output voltage can
only be a multiple of the “Voltage / bit” value (rounding effect).
Page: 14-94
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
321 Attributes for analog outputs
HAND-F2-F3-F3-F2
Analog outputs are now retained when drive system is OFF. If the parameter "Retain"
is selected, the analog value at the time of drive system OFF will be frozen. Other
attributes will follow with version 1.14, such as, responses during operating mode
changes and responses during operating mode changes made in HAND mode.
]
The following menu will be displayed after pressing the [F2] function key or
entering the number 321:
321 :
Attributes for analog outputs o1 - o8
Analog channel number
:
o1
Status when act. off
:
Zero
Status after BAW
:
Zero
[F1]
[F2]
[F3]
[F4]
+No
-No
ZERO
Retain
F1
F2
F3
F4
F5
+No.
The displayed channel No. will be increased by 1
-No.
The displayed channel No. will be decreased 1
ZERO
The displayed channel No. will be set to zero by the corresponding status
Retain
The last entered status will be retained
330 PLC-macros
Hand-F2-F3-F4
PLC-macros offer the advantage that a specific order of repeatable PLC instructions
only have to be programmed once and afterwards it can be called up from any
programmed point within all programmed sequences.
These combined instructions are known as a macro. Up to 200 different PLC-macros
(M0 - M199) can be defined in the controller. Each individual macro can contain up to
100 PLC instructions or links to inputs, outputs, markers, gripper functions, wait
conditions etc., that will be executed consecutively.
The combination is so wide that in one macro up to 10 other macros can be called up
one after the other (encapsulated depth = 10).
Exception:
Macros cannot call up themselves (e.g. macro 1 cannot call up macro 1).
07.03.02
Elektroplanung-und Anlagenbau
Page:14-95
VRS 1
]
The following screen will be displayed after selecting the constant No. 330
the following text will be displayed:
The following macros are programmed :
Macro
0: Gripper 1 work table closed
Macro
1: Gripper 1 work table open
Macro
2: Stroke closed
Macro
3: Stroke open
Please enter the macro – No. (0 – 199) >
Continue
F1
F2
F3
F4
F5
The previously programmed macros will be displayed. The macro-No. for processing
can now be entered.
Teaching/editing macros
] The screen will change after entering the macro-No. for teaching:
The following macros are programmed :
Macro
0: Gripper 1 work table closed
Macro
1: Gripper 1 work table open
Macro
2: Stroke closed
Macro
3: Stroke open
Please enter the macro – No. (0 – 199) >
Delete
All
Name
Edit
Copy
F1
Page: 14-96
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Now press the [F1] function key in order to teach a new macro and the screen
will change to:
Edit macro No.1
1 >
2
3
4
5
OUTPUT MACRO
F1
F2
MACRO TEACHING
WAIT
F3
GRIPPER Continue
F4
F5
Use the [F1] - [F5] function keys to call up and enter the relevant PLC instructions that
are to be combined under this macro-No.
FLAG
ARITH.
VERIF.
MARKER
F1
F2
F3
COUNTER
TIMER
BINARY
F1
F2
F3
JUMP
MARK
JUMP
F1
F2
Continue
F4
ANALOG Continue
F4
IBM
Dock
F3
F5
F5
Continue
F4
F5
The programming and editing of macros is carried out analogous to point
related PLC. Read the section in chapter 9 "PLC-Programming" for further
information regarding this.
Deleting a macro
]
Enter the macro No.
]
Confirm the entry by pressing the [Return] key. The following text will be
displayed:
The following macros are programmed :
Macro
0: Gripper 1 work table closed
Macro
1: Gripper 1 work table open
Macro
2: Stroke closed
Macro
3: Stroke open
Please enter the macro – No. (0 – 199) >
Delete
All
Name
Edit
Copy
F1
07.03.02
F2
F3
F4
Elektroplanung-und Anlagenbau
F5
Page:14-97
VRS 1
]
Macro 2 will be deleted after the [F3] function key is pressed.
]
Press [F4] or [F5] function keys in order to delete all macros. The following
menu will be displayed:
Delete macro No.
2
Yes
No
All
F1
F2
F3
F4
F5
]
After pressing the [F1] function key macro 2 will be deleted. The 'macro 2 was
deleted' report will be displayed afterwards.
]
Press the [F2] function key to retain the macro and the next programmed
macro-No. will be displayed.
]
Press [F3] function key and all following programmed macros including macro
No.2 will be deleted and the output menu will be displayed.
]
Press the [Esc] key when the output menu is displayed and you can enter a
new macro-No.
340 Setting the PLC-counters (arithm.)
Hand-F2-F3-F5
In the PLC there are 16 arithmetical counters ( i0 - i15) available for use that can
accept whole numbers between -9999 and +9999.
These counters can be used as:
• Result displays for a logical link
• Identifier (flag)
The content of a counter can also be set or reset to a specific starting value. If they are
exceeded (> +9999) or under run (< -9999) the counter contents will remain at the
maximum value.
The counters are global, i.e. valid for all sequences and S-Ps and are not automatically
reset to "0" at the end of a sequence or by a sequence change!
Apart from this, they are so linked that they do not lose their current values during the
power-down routine or during power failures.
!
Note:
Positive number divided by "0" =
Negative number divided by "0" =
0 divided by "0"
=
Page: 14-98
+9999
-9999
0
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The following menu will be displayed after selecting constant No. 340:
]
340 :
I0:
I2:
I4:
I6:
I8:
I+
F1
Counter value
0
0
0
0
0
i1:
i3:
i5:
i7:
i9:
0
0
0
0
0
i-
F2
F3
F4
F5
]
Use the [F1] or [F2] function keys to position the cursor on the required
counter input field
]
Enter the relevant value (maximum +/-9999).
]
Confirm the entry by pressing the [Return] key.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-99
VRS 1
350 - 354 Interbus master menu
General information
The interbus master/slave cards (5E-1494 and 5E-1528) will be first supported as from
Version 1.14. The difference between the cards is that the 5E-1494 is not fitted with
light controls and the 5E-1528 is fitted with light controls (SUPI-OPC).
The interbus master / slave cards include full G4 master functionality. The bus interface
operates using LWL-technology. The front side of these cards are sub-divided into
three sections. The master section with two LWL connections (REMOTE IN / REMOTE
OUT) and the associated diagnostic LEDs are located in the upper third. The centre
third of the card holds the slave part of this card. There are two LWL connections for
the incoming bus and two other connections for the outgoing bus fitted here. The 24volt DC power supply for the slave and a RS 232 interface are fitted in the lower third of
the card. This interface is provided so that a serial connection can be made with a PC
running Windows 95, in which Phoenix CMD Tool Version 4.42 has been installed. This
enables the interbus to be set-up and the diagnostics to be run.
!
Attention! It is no longer possible to use the card from the previous
version, which was called the auxiliary module (I/O card), with this upgrade
due to the major software modifications.
Installation information:
The supplier of the VRS 1 interbus card has completely set-up and correctly fitted the
jumpers. This card can be installed in any slot in the control system computer. The
transmitting power of the LWL transmitting module can be individually optimised via the
jumpers. The jumper settings must be set so that they comply with the Phoenix
guidelines for the LWL interbus.
Page: 14-100
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Please pay attention to the attached guidelines for “Phoenix” Contact when installing
the LWL lines. The permitted bending radiuses must be adhered to. The maximum
length of an LWL path is restricted. The glass fibre fitted at the end of a LWL cable
must be of sufficient size. If necessary, check the attenuation of the cable.
A current of approx. 0.5A should be maintained for the external 24-volt supply for the
slave.
Preconditions:
VRS 1 operating system version 1.14 or higher.
Interbus master / slave cards for VRS1 robot system using 5E-1494 or 5E-1528.
The “Online Diagnose” has been expanded accordingly in automatic or single step
modes. A small change has been made to DA – output only. The virtual output sizes of
the DA channels are now displayed here. The logical analog channel in not assigned a
physical output channel in “Modify constant”, so an analog value is in fact displayed in
“Online Diagnose” , however there is no output without a physical assignment.
All 16 logical output channels will be displayed at first when paging through the analog
output channels using the online diagnostics. If you continue to page through using
[CURSOR DOWN], the current axes velocities will then be displayed as analog output
sizes.
Entering / Displaying of “Hexadecimal numbers”:
Hexadecimal entries are required in certain menus. A short description of how to enter
hexadecimal values from “A” to “F” for the different PHGs.
With the new VRS 1B/C PHG, the entry is made via the integrated ASCII keyboard.
The old PHG is not fitted with an alphanumerical keyboard. The entering of a
hexadecimal number is made using the [SHIFT] key. The following table shows the key
assignments:
Keys
SHIFT + 1
SHIFT + 2
SHIFT + 3
Significance
Hexidec “A”
Hexadec “B”
Hexadec “C”
Keys
SHIFT + 4
SHIFT + 5
SHIFT + 6
Significance
Hexadec “D”
Hexadec “E”
Hexadec “F”
Take note here that the [SHIFT] key must be pressed and held down first (e.g. the
“SHF” and then key “2” produce a hexadecimal value of “B”).
Hexadecimal input fields start with a “0” and finish with the letter “h”.
Example:
028AEh (Hex) => 10414 (decimal).
07.03.02
Elektroplanung-und Anlagenbau
Page:14-101
VRS 1
]
Select the [Hand] operating mode and then press the [F2], [F3], [F4] and [F5]
function keys. The following menu will then be displayed:
350 - 354: INTERBUS MASTER MENU
F1 = Execute IBM operations
F2 = Edit configurations
350 F3
354= Slave configurations
F4 = Edit module names
F5 = IBM config./ Top 10 error list
350
351
352
353
354
Enter: (F1 - F5), 350 - 354
F1
F2
F3
F4
F5
350 Executing interbus operations
]
The following menu is displayed after constant No. 350 is selected:
350:
Execute IBM operations
IBM Status = Run
F1: Stop the data transfer
F2: Load configuration
F3: Save
F4: Acknowledge / diagnose error
F5: Start the bus
Report:
Stop bus
Load
Save Ack. error
Start
F1
F2
F3
F4
F5
]
Press the [F1] function key to stop the data transfer
]
Press the [F2] function key to load a configuration
]
Press the [F3] function key to save a new configuration set-up to the RAMcard
]
Press the [F4] function key to acknowledge a displayed error report
]
Press the [F5] function key to start the BUS
]
Press the [Esc] key to redisplay the output menu
Page: 14-102
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
351 Setting-up and editing the interbus
The interbus can be set-up in various ways. An error report is displayed (if an interbus
configuration is not available) after the control system has booted up, which states that
the interbus is not in “RUN” mode. Acknowledge this report in Hand mode.
A configuration can be set-up here by directly editing the CFG, PDRL and PDDL lists
(experts only!).
]
The following menu is displayed after constant No. 351 is selected:
351:
IBM set-up / edit
F1: Edit IBM CFG
F2: Edit IBM PDRL
F3: Edit IBM PDDL
CFG
F1
PDRL
F2
PDDL
F3
F4
F5
It is only possible to make the modifications in conjunction with a key
disc!
07.03.02
Elektroplanung-und Anlagenbau
Page:14-103
VRS 1
Editing the IBM CFG
] The following menu is displayed after the [F1] function key is pressed:
Edit IBM CFG
IBM Status = Run
Mod.No. :
1
Position :
0
Length
:
1
ID :
11
Level
:
0
Alt.Gr.No. :
0FFh
Alt.No. : 0FFh
Entry No.
:
1
Entry + Entry Delete
Insert
F1
F2
F3
F4
F5
The individual names are explained in the following:
Mod. No.
Position:
Module-ID:
Module length
code
Bus level:
Alt. Gr. No.:
Indicates a bus module by referring to the module number
(e.g. 3.1)
Indicates the position of the module
The module-ID indicates the type of interbus module and its
function.
The length code describes the address area of an interbus
module and also the length of the input and output process
data in coded form (in words).
ATTENTION! A “-1““ must be entered for a byte module here.
The bus level states at which level each module can be found
in the interbus tree structure. The maximum permitted value
for this is 16.
This function (alternative group number and Alt. No.:
alternative number) is used for docking or undocking bus
segments (both values must differ from $FF).
Please read the “Interbus docking function” section in this chapter as well.
!
Note:
The “ID-code”, “Length code” and “bus level” information are obligatory entries
for each module. The module sequence in the frame corresponds with the
position within the bus system. Exceptions to this are alternative modules, which
are not operated simultaneously in the bus system.
Page: 14-104
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
IBM process data reference list
In general the assignments of the interbus I/O addresses for the individual modules are
to be found in this list. Bus modules that do not have any process data (e.g. bus
terminals), are not shown in this list.
Index: only one defined index number is permitted for each PDRL entry. You must
ensure that index 0000h (hexadecimal) to 3FFFh is specifically used for inputs, index
4000h to 7FFFh is specifically used for outputs and index 8000h to BFFFh is
specifically used for throughput data.
PDD-index indicates a reference to any existing PDDs. This means so-called “Default”
– PDDs. The value 6010h indicates a so-called “Default-index” for inputs and the value
6011h indicates the “Default-index” for outputs. All input or output modules, which are
included in one of these indexes, do not have PDD-entries, i.e. their I/O images are to
be briefly found in memory. All other indexes are only allowed to be used once for a
given module. It refers to an entry in the PDD-list (single bytes or bits can be set in
another I/O sector here).
]
The following menu is displayed after the [F2] function key is pressed:
351:
IBM process inputs data reference list
IBM Status = Run
Index
:
1
Mod.No.
:
1
Position:
0
PDD-Index :
06010h
BYTE.Adr. :
0
Bit-No.
:
0
Data-Cons :
0
Entry No.
:
1
Entry + Entry Delete
Insert
F1
F2
F3
F4
F5
The individual names are explained in the following table:
ModuleNo.
Position
PDDindex
Byteaddr.
Bit-No.
07.03.02
Indicates the associated module number
Indicates the position on the bus
Indicates a reference to any existing PDDs. There are also socalled “Default” PDDs. The value 6010h indicates a so-called
default-index for inputs and the value 6011h indicates the
default-index for outputs.
All input or output modules, which have one of these indexes,
do not have PDD entries, i.e. their I/O images are to be briefly
found in memory. All other indexes are only allowed to be
used once for a given module. It refers to an entry in the PDDlist.
Indicates the byte number, from which the process data image
of the respective bus module has been filed.
Indicates a reference type for the PDD-list. The respective
value describes if one or more bit(s) or a byte have to be
moved in the PDD-list.
Elektroplanung-und Anlagenbau
Page:14-105
VRS 1
IBM Process data description list
If single bits or bytes of a module have to be mapped to different addresses, PDD
entries are required.
]
The following menu is displayed after the [F3] function key is pressed:
351:
Edit IBM process data desciption list
IBM Status = Run
Mod.No.
:
1
Position :
0
0
PDD Index :
00000h
PDD type :
Byte-No.
:
0
Data type :
0
Bit/byte No. :
0
Number :
0
Entry No. :
1 (new)
Entry + Entry Delete
Insert
F1
F2
F3
F4
F5
The individual names are explained in the following table:
Module-No.
Position
PDD-index
PDD-type
Byte-No.
Bit/byte-No.
Number
]
Indicates the respective bus module
Indicates the position of the module on the bus
Is the reference for the respective bus module
Can only be entered if one or more bits or a complete byte has
to be mapped into another I/O sector.
If a PDD bit has been provided, the byte from the mapped bit
will be entered in the byte-No. If a PDD byte has been
provided, the byte that requires moving will be entered in the
“Byte-No.”.
The bit number from the previously entered byte must now be
assigned to the bit/byte-No.
The number of bits or bytes by which the following bits or
bytes must be moved must now be entered.
The output menu will be displayed after the [Esc] key is pressed
Page: 14-106
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Interbus – docking function:
The interbus docking function is required, when one or more interbus modules have to
be docked or undocked whilst the operation is running. A classic example of this is the
physical docking of an interbus welding piece. A precondition here is that a bus
terminal must be available in the interbus ring, and this will provides a sample link for
the dockable welding piece.
z Inter
bus
z mast
16 bit I/O
gripper
Mod. 4.0
Bus
terminal
Mod. 1.0
Bus
terminal
Mod. 2.0
8 bit I/O
docking
piece
Mod 5 0
8 bit I/O
docking
piece
Mod 6 0
Altern. No. 1
Altern. No. 2
Alternative group number 1
z 16 bit
I/O
z Mod.
32 bit I/O
gripper
Mod. 7.0
Altern. No. 1
Altern. No. 2
Alternative group number 2
Certain modifications must be made in the CFG-list (constant 351 F1) in order to be
able to dock the piece. In this example module 4.0 must be linked to level 1.
Furthermore, an “alternative” group number (e.g. 1) and an alternative number must be
entered for this module (e.g. 1). The value must be different to “FF”. An alternative
group number always indicates a defined switching point. In this example the
relationship is with the bus terminal 2.0. Up to 255 different alternatives can now be
undocked at this switching point. These different alternatives are identified by the
“Alternative number”.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-107
VRS 1
Interbus
master
Bus terminal
Mod. 1.0
Bus terminal
Mod. 2.0
16 bit I/O
Mod. 3.0
16 bit I/O
gripper
Mod. 4.0
8 bit I/O
docking
piece
Mod. 5.0
8 bit I/O
docking piece
Mod. 6.0
32 bit I/O
gripper
Mod. 7.0
Altern. No. 1
Altern. No. 2
Alternative group number 1
Altern. No. 1
Altern. No. 2
Alternative group number 2
This example shows a bus configuration with two docking points. Correspondingly,
alternative group numbers must be entered for the dockable modules.
In this example modules 4.0 and 5.0 contain the alternative group number 1 and
modules 6.0 and 7.0 contain the alternative group number 2. Module 4.0 contains the
alternative number 1 together with the group number 1, etc.
The docking commands in the PLC can now be used to execute the docking
processes. A precondition here regarding this is that a dockable interbus module must
be entered in the piece menu for a docking piece. There is now a new “Dock”
command in the PLC. The letter “D” is then displayed in the PLC line. Either a “0” for
“undock” or a “1” for “dock” can be entered afterwards. A module number is now
displayed and the associated module name (if available). The required module can
now be selected from the list of dockable modules using CURSOR UP or DOWN.
Terminate the selection process by pressing the “RETURN” key.
Page: 14-108
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
352 Setting-up the interbus slave
]
Hand-F2-F3-F2-F5-F3
The following menu is displayed after constant No. 352 is selected:
352:
IBS Slave setting-up
IBM Status = Run
Length
:
3
ID :
Master queue at address: 100
F1
F2
F3
F4
3
F5
]
The slave length must be set first; the length has been set to 3 words in the
example above.
It is possible to enter up to 10 words.
]
The slave ID is automatically set to 3
The master status can be mapped into an unused sector and evaluated accordingly.
In this example the word has been assigned to byte address 100.
The 16 bits have the following significances at status one:
Output
801
802
803
804
805
806
807
]
Name
BSA
BASP/SYS_FILE
RESULT
SY_ESULT
DC_RESULT
WARN
QBIT
808
809
SDS1
AF
810
811
812
813
814
815
816
PF
BUS
CTRL
DETECT
RUN
ACTIVE
READY
Significance
The bus segment is switched off (docked)
The outputs will be reset
A standard function was negatively processed
Synchronisation error
Erroneous data cycle
A specific waiting period has been exceeded
The quality of the transfer is unacceptable (e.g.
the LWL cable has become porous)
Control system report
Application error, e.g. wrong configuration
loaded
Peripheral error , e.g. blown fuse
Bus failure
Error at connecting module (hardware)
Diagnose is active
Bus is in RUN mode
Bus is active
Bus running without errors
The output menu will be displayed after the [Esc] key is pressed
07.03.02
Elektroplanung-und Anlagenbau
Page:14-109
VRS 1
353 Editing the interbus module names
Hand-F2-F3-F2-F5-F4
An option that can be used in constant 353 is the ability to give each module a socalled module name. This is of significance when running error diagnostics or for the
docking function. If, for example, a bus failure occurs whilst the system is running, then
an error report consisting of the error code (see user handbook) and the module
number will be displayed. If an additional module name is entered for this module, this
will be displayed on the PHG display. This makes determining the location of the error
much easier.
]
The following menu is displayed after constant No. 353 is selected:
353:
Edit IBS module names
Mod.No. :
Entry :
Report:
Entry +
F1
1
1 Name: I/O
Entry -
Save
F2
F3
Pos.:
8 bit
0
Text
F4
F5
]
Press [F1] or [F2] function keys to either jump to the next entry or to jump
back by one entry.
]
Press the [F3] function key to save the settings.
]
Press the [F5] function key to pop-up the text editor and freely defined text
can then be entered.
]
The output menu will be displayed after the [Esc] key is pressed
Page: 14-110
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
354 Interbus configuration
Hand-F2-F3-F2-F5-F5
In this menu you have the options to see the error list, to switch the
MASTER mode in or out or to use two different methods to set-up the configuration.
The different functions are described one after the other.
]
The following menu is displayed after constant No. 354 is selected:
354:
IBS configuration / Top 10 list
IBM Status = Run
F1: Top 10 error list
F2: Master activate/deactivate
F3: Read out IBM configuration
F5: IBM automatic configuration
Report:
Top 10 Master Read out
F1
]
F2
F3
AutoCFG
F4
F5
Press the [F1] function key to jump to the Top10 error list
IBM Top 10 error list
ErrCode:
Module:
Entry:
No entry, acknowledge with ESC
Entry + Entry -
F1
F2
F3
F4
F5
]
Press the [F1] or [F2] function keys to page backwards or forwards in the
error list
]
Press [ESC] to exit this menu and jump to the output menu
07.03.02
Elektroplanung-und Anlagenbau
Page:14-111
VRS 1
Activating / deactivating the master
] Press the [F2] function key to branch to a menu in which the master status
can be activated or deactivated or the slave address can be set.
354:
Activate the IBM Master
F1: Master status
F2: Slave address
active
104
Passive Slave add.
F1
F2
F3
F4
F5
]
Press the [F1] function key to switch the IBM master on or off
]
Press the [F2] function key to match the slave address
]
Press [ESC] to exit this menu again
Reading out the IBM configuration
After the interbus master/slave card has been parameterised with the CMDtool,
the parameterisation can be read into the control system by pressing the [F3] function
key
IBM automatic configuration
Press the [F5] function key to automatically read in an interconnected master bus.
You must ensure that all modules are read in sequence, i.e. one after the other. The
configuration can be optimised if necessary.
Page: 14-112
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Configuring using the control system
] The bus must already be in the “READY” state. If necessary, a data transfer
already underway must be stopped by pressing [F1] in constant 350. This
action will also log-off the existing configuration.
]
Select constant 354 and press the [F5] key to read in the bus configuration
automatically. The interconnected bus user will then be automatically stored in
a configuration frame. Check the configuration frame against the actual bus
set-up.
]
Press [F1] in constant 351 to identify all of the users on the bus that have
been read in.
]
Press [F2] to view the process data reference list for the individual users and
match or modify the parameter wherever necessary. Basically, this list
contains both input & output assignment tables for the individual users and the
source addresses for the inputs and the destination addresses for the outputs
must be matched according to the details.
ATTENTION! The addresses that have to be entered are byte addresses,
however please note that a module can only be mapped to an even address,
as only one byte’s length of usable data can be transferred (byte address 0
corresponds to bits 1 to 8; byte address 1 corresponds to bits 9 to 16; byte
address 3 corresponds to bits 17 to 24, etc.).
]
Now press [F5] to restart the data transfer and this will up-date the
modifications (PDRL-list). If the bus starts without any error reports, this
configuration can now be saved by pressing [F3]. If the bus fails to start, an
error report, consisting of the error code and the parameters will be displayed.
An itemised breakdown of these error codes can be found, for example, in the
“User handbook for service and error reports for 4.x firmware” from “Phoenix”.
It is usually possible to precisely localise the error and then make a correction
using this. Now try to restart the bus by pressing [F5] in constant 350.
]
When the required configuration has been set-up, it must be saved by
pressing [F3] in constant 350, so that this configuration will be launched
automatically the next time the controller is started.
]
The master state must now be activated in constant 354 as well.
]
The output menu will be redisplayed after the [Esc] key is pressed.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-113
VRS 1
Changing the output bytes using the control system
Example:
The bytes for output module 2.1 have to be changed. Two new entries have to be setup and parameterised in the PDRL and PDDL lists for this.
Procedure:
] The bus must be stopped
]
Call up the edit configuration menu and open the PDRL list
]
Delete the old entries for module 2.1
]
Two new entries must be entered, to this go to the end of the list and press
[F5] = OUT-PDR
351:
IBM inputs process data reference list
IBM Status = Run
Index
:
0
Mod.No.
:
0
Position:
0
PDD-Index :
0000h
BYTE.Addr.:
0
Bit-No.
:
0
Data-cons :
0
Entry No.
:
1(New)
Entry + Entry Delete
OUT-PDR
F1
F2
F3
F4
F5
Note:
Toggle the [F5] function key between:
OUT – PDR (for output module)
IN – PDR (for input module)
THR – PDR (for going through the inputs and outputs)
] The following parameters must be entered:
Index
Module-No.
PDD - index
Bit-No.
Position
Byte-No.
Data – Cons.
!
Old entry
4002 h
2
6011 h
0
1
0
2
1st new entry
4002 h
2
6012 h
0
1
0
2
2nd new entry
4003 h
2
6013 h
0
1
1
2
Please ensure that all index hexadecimal numbers have to be entered
consecutively!
Page: 14-114
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The 2 in the data-cons indicates the number bits being handled, in this case they are 8bit.
] Press insert and the entry will be inserted into the list. Proceed in the same
way for the second entry.
]
Press the [ESC] key to exit this menu
]
The PDRL-list must now be called-up, the following menu will be displayed:
351:
Edit IBM process data desciption
IBM Status = Run
Mod.No.
:
1
Position :
0
PDD Index :
00000h
PDD type :
0
Byte-No.
:
0
Data type :
0
0
Number :
0
Bit/byte No. :
Entry No.
:
1 (new)
Entry + Entry Delete
Insert
F1
]
F2
F4
F5
Insert two new entries at the end and then enter the following parameters:
Old entry
-
Mod. No.
PDD – index
Byte-No.
Bit/byte No.
Position
PDD type
Data type
Number
!
F3
1st new entry
2
6012 h
1
0
1
13
10
1
2nd new entry
2
6013 h
0
0
1
13
10
1
Note:
Ensure that the PDD-index has the same names as those in the PDRL-list
]
Save the modified configuration in constant 350
]
Now restart the BUS
The bit-swap and pass-through are programmed in the same way.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-115
VRS 1
400 - 419 Tool constants
Hand-F2-F4
Up to 7 different tools are available for use in the controller. Each tool is allocated a
permanent tool number (No.1 - 7), under which the special constants for each tool will
be saved in the controller. An additional tool (No. 8) is exclusively defined as the
reference tool.
Read the "Automatically measuring the TCP using the reference tool" section
in this chapter for further information regarding this.
The following measures are required for entering the tool constants:
• Set tool-No. for teaching (see constant 400)
• Measure the TCP and enter them (see constant 401)
]
Select [Hand] operating mode, then press [F2] and [F4] function keys. The
following menu will be displayed:
400 - 419 : Tool constants
F1 = Set tool for TEACHING
F2 = Set tool centre point (TCP)
F3 = Set tool loading data
400
401
402
Input :
F1
F2
F3
F4
F5
A tool can be also be allocated other functions (so-called gripper functions). For this
reason the tool must be allocated a gripper type.
The definitions for the handling or welding gripper or the welding macros can
be found in the constant 300 description.
Page: 14-116
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
400 Setting the tool for teaching
Hand-F2-F4-F1
The number of the current tool must be selected before the teaching of an operating
sequence, i.e. set up for teaching.
Important note
A movement sequence can only be traversed using the precise trajectory run
and the correct tool number has been selected and this tool has been precisely
measured for teaching the operating sequence.
!
]
The following input menu will be displayed after selecting constant No. 400:
400 :
Setting tool for TEACHING
Minimum : 1
Maximum :
Default :
1
7
Press ESC to abort
Input :
(1 - 7)
F1
F2
F3
F4
]
Enter the tool-No. (maximum 1 - 7)
]
Confirm the entry by pressing the [Return] key.
F5
The trajectory module takes into account the geometrical offsets of the selected tools
when calculating the cartesian co-ordinates of the operating sequence.
]
Press the [Esc] key to exit the menu.
401 Tool measuring (TCP)
Hand-F2-F4-F2
The tool tip (Tool-Centre-Point) is the point from which the actual processing of the
work piece will be carried out, e.g.:
Welding gripper:
TCP
=
between both electrodes
Handling gripper:
TCP
=
between the gripper jaws
Spray pistol:
TCP
=
at the nozzle tip
The monitoring of the tools can be carried out at the robot head (hand fitting plate) or
an externally constructed securing position.
If the tools are fitted at the hand fitting plate the mechanical robot measurements will
be modified in relation to the working point.
In order to make a precise calculation of the working points, the orientation, the
traversing path as well as guaranteeing the traversing velocity, the trajectory module
requires the exact position of the Tool-Centre-Points relative to the head co-ordinates
system.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-117
VRS 1
Due to the additional input options of the RPY-angles a, b and c, the turning of the
head co-ordinate systems can be achieved in a tool co-ordinates system.
Advantage:
• Clearly improved, task orientated programming by means of contour parallel
traversing of the TCP during teaching.
• Weaving according to the axes of the tool co-ordinate systems.
In order to measure the flanged tools, axes 4, 5 and 6 must be in the basic mechanical
positions (marking position). Reference point for the measurement is the flange of axis
No. 6 (see next page for an example).
]
The following menu will be displayed after selecting constant No. 401:
401 :
Enter tool (TCP)
Head
x : 0 1/10 mm
|
a : 0 1/10 mm
y : 0 1/10 mm
|
b : 0 1/10mm
z : 0 1/10 mm
|
c : 0 1/10 mm
Tool No.:
1
| Enter axis x :
Modified TCP affects sequence:
Automatic tool TOGGLE
No+/Axis+/TCP
RPY
BC/HC
F1
F2
F3
F4
F5
]
Use the [F1] function key to select the required tool.
]
Use the [F2] function key to position the axis (X, Y & Z) or the EULER-angle
(a, b & c).
]
Enter the measured axis value or the angle.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed.
]
Use the [F5] function key to select the head co-ordinates system (HC) if the
tool is fitted on the robot or the basic co-ordinates system (BC) if the tool was
fitted externally.
]
Press the [Esc] key to exit the menu.
The example shows a flanged welding gripper. The TCP lies between the tips of the
electrodes.
Page: 14-118
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
The deviation of the TCP in X, Y & Z directions refers to the presumed head coordinates system at the flange of axis 6 which must be measured and entered. When
making the entry, attention must be paid to the sign for the co-ordinate device without
fail!
TCP
forr LSV_2
LSV_25
TC P fü
5
+X
TC P
+Y
g sp u nreference
kt Fla n sc h
•Be zuFlange
for 6the axis 6
d e rpoint
A c hse
Y
Z
X
-Y
+Z
-X
Tool measuring (TCP external)
By using the controller you can traverse the robot to an externally secured tool in order
to process the tool piece. This procedure is especially suitable for spreading adhesive,
de-burring etc. Because of this assignment the TCP (tool working point) is no longer
locked to the robot head (head co-ordinates system), but with the basic (global) coordinates system.
e r TC P
+ XExtez rnExterna
TC P
+Y
Z +Y
Y
-Y
+Z
•Exte Externally
rn b e fe stig te s
attached
W e rkze
u g tool
X
Basic
(global)
Ba si+
s-(W
Ze lt-) co-ordinates
system
Ko o rd in a te n syste m
(in central robot foot)
(im Ze n tru m R o b o te rfu ß
07.03.02
-X
+X
Elektroplanung-und Anlagenbau
Page:14-119
VRS 1
]
The following menu will be displayed after selecting constant No. 401:
401 :
Enter tool (TCP)
Head
x : 0 1/10 mm
|
a : 0 1/10 mm
y : 0 1/10 mm
|
b : 0 1/10mm
z : 0 1/10 mm
|
c : 0 1/10 mm
Tool no: 1
| Enter axis x :
Modified TCP affects sequence:
Automatic tool TOGGLE
No+/Axis+/TCP
RPY
BC/HC
F1
F2
F3
F4
F5
]
Use the [F1] function key to select the required tool.
]
Use the [F5] function key to select the basic co-ordinates (BA).
]
Use the [F2] function key to position the axis (X, Y & Z) or the EULER-angle
(a, b & c).
]
Enter the measured axis value or the angle.
]
Press the [Return] key to finalise and then the entered value will be imported
and displayed.
]
Press the [Esc] key to exit the menu.
Automatic tool measuring
With many tools the measuring of the TCP is very costly and is only possible when
using costly measurement traversing.
The measuring and reading accuracy generated by this can result in an unsatisfactory
robot application.
The automatic measurement:
• Simplifies this process and prevents inaccuracies from occurring
• Covers the automatic measuring of the TCP's
• Also enables the automatic determining of the tool orientation (angle offsets
for RPY-angles)
The tool measuring involves 3 methods that can be applied individually:
• TCP measurement without a reference tool (4 point method)
• TCP measurement with a reference tool (2 point method)
• Orientation setting via 2 points
Page: 14-120
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Automatic TCP-measuring
In addition to the existing traversing for the TCP determining via a reference tool, an
additional traversing has been integrated which does not use a reference tool. It has to
traverse from various directions to any selectable TCP that is using an unknown tool.
Procedure:
• A reference sequence having 4 points must be taught.
• The sequence can be taught using an unknown tool.
• All values have zero entered for the tool measuring (constant 401).
• The 4 points are taught, so that the TCP of the unknown tool can traverse a fixed
area using 4 different orientations.
• The fixed area is best realised using the tip of a tripod.
The order of the points can be seen in the following diagram.
Po in t 1
Po in t 2
Po in t 3
Po in t 4
07.03.02
Elektroplanung-und Anlagenbau
Page:14-121
VRS 1
Use [F3] in constant menu 401 to start the automatic tool measuring. The controller
calculates the geometric tool dimensions from the reference sequence and enters the
determined values.
In order to check the dimensions, you can swivel the tool around the determined fixed
point.
Poi1
Puz nkt
t1
Point
Pu
nkt33
Pu nkt22
Point
Fixed
Fe ste r
TCP
Ra u m p u n kt
Point
Pu
nkt44
The determining of the tool orientation is carried out as previously using a reference
sequence with two points that will set the Z-impact direction of the tool.
Page: 14-122
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Teaching the reference sequence
After fitting the tool to be measured, a reference sequence using 4 points must be
programmed. The reference sequence must be taught using a zero tool! The order is
given in the illustration.
]
Use the [F1] function key to select the teaching menu from the [Hand] main
menu
]
Enter any unused sequence -No.
]
Press the [F1] function key = New teaching.
]
Traverse to an identified point (fixed point) using the tool's TCP.
]
Press the [F2] function key = co-ordinates in order to teach this reference
point as point "0" of the reference sequence.
]
Traverse to the fixed point with the tool's TCP again but use a different
orientation.
]
Press the [F2] function key in order to teach this reference point as point 1 of
the reference sequence.
]
Traverse points 2 and 3 in the same manner as used for point 1.
]
Press the [F4] function key in order to finalise the reference sequence.
]
Use the [Esc] key to exit the menu.
Automatic calculation of the TCP
If the reference sequence has been taught using 4 points, the TCP - co-ordinates for
the relevant tool can now be determined.
]
Select constant No. 401. The following menu will be displayed:
401 :
Enter tool (TCP)
Head
X : 0 1/10 mm
|
a : 0 1/10 mm
y : 0 1/10 mm
|
b : 0 1/10mm
Z : 0 1/10 mm
|
c : 0 1/10 mm
Tool no: 1
| Enter axis x :
Modified TCP affects sequence:
Automatic tool TOGGLE
No+/Axis+/TCP
RPY
BC/HC
F1
]
F2
F3
F4
F5
Press the [F1] function key until the tool No. that you wish to save the new tool
under is displayed.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-123
VRS 1
]
Press the [F3] key to change the screen:
401 :
Enter tool (TCP)
Head
X : 0 1/10 mm
|
a : 0 1/10 mm
y : 0 1/10 mm
|
b : 0 1/10mm
Z : 0 1/10 mm
|
c : 0 1/10 mm
Tool no: 1
| Enter sequence No :
Ehter the seq, number for the calculation !
Automatic tool TOGGLE
No+/Axis+/TCP
RPY
BC/HC
F1
F2
F3
F4
F5
]
The cursor blinks beneath the input field for the sequence-No. Now enter the
reference sequence -No. that was used for the four point teaching.
Only a reference sequences with 4 point are permitted.
]
Press the [Return] key to start the automatic calculation. The calculated
values for x, y & z will be displayed and saved.
]
Press the [Esc] key to exit the menu.
TCP automatic measuring (using reference tool)
When measuring using a reference tool (known tool), the tool data for x, y and z will be
calculated by first traversing to a fixed point using a known tool and afterwards using
an unknown tool.
A pre-condition is that a reference tool is required whose geometric x, y and z
dimensions are known precisely.
The geometrical dimensions (x, y & z) of the reference tools are to be entered in a
menu (for tool-No. 8) specially created for this.
]
Use the [F5] function key to select the head co-ordinates system.
]
Mount the reference tool on the robot.
]
Select constant No. 401.
401 :
Enter tool (TCP)
Head
X : 0 1/10 mm
|
a : 0 1/10 mm
y : 0 1/10 mm
|
b : 0 1/10mm
Z : 0 1/10 mm
|
c : 0 1/10 mm
Tool no: 1
| Enter axis x :
Modified TCP affects sequence:
Automic tool TOGGLE
No+/Axis+/TCP
RPY
BC/HC
F1
Page: 14-124
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Press the [F1] function key until tool-No. 8 is displayed. Afterwards the menu
will change so that the reference tool data can be entered.
401 :
Enter tool (TCP)
Head
X : 0 1/10 mm
|
a : 0 1/10 mm
y : 0 1/10 mm
|
b : 0 1/10mm
Z : 0 1/10 mm
|
c : 0 1/10 mm
Tool no.:
8
| Enter sequence No :
Enter the seq. Number for the calculation !
No+/-
F1
Axis+/-
F2
F3
F4
F5
]
Use the [F2] function key to select the respective axis (X, Y, & Z).
]
Enter the relevant value for the reference tool.
]
Each entry must be confirmed by pressing the [Return] key. The entered
value will be displayed.
]
Press the [Esc] key to exit the menu.
Teaching the reference sequence
After fitting and entering the reference tool data a reference sequence must be
programmed using a zero - tool.
]
Select the [Hand] operating mode from the main menu.
]
Press the [F1] function key.
]
Enter any unused sequence -No.
]
Press the [F1] function key.
]
Traverse to a fixed point using the reference tool.
]
Press the [F2] function key in order to teach this reference point as point "0" of
the reference sequence.
]
Switch off the robot drive system.
]
Traverse back to the fixed point using the original tool TCP.
]
Press the [F2] function key in order to teach this as point 1 of the reference
sequence
]
Press the function key [F4] in order to finalise the reference sequence.
]
Use the [Esc] key to exit the menu.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-125
VRS 1
Automatic calculation of the TCP
If the reference sequence was taught using 2 points and a reference tool, the TCP - coordinates for the relevant tool can be determined from this.
]
Select constant No. 401 an. The following menu will be displayed:
401 :
Enter tool (TCP)
X : 0 1/10 mm
|
a:
y : 0 1/10 mm
|
b:
Z : 0 1/10 mm
|
c:
Tool no: 1
| Enter axis
Modified TCP affects sequence:
Automic tool
No+/Axis+/TCP
Head
0 1/10 mm
0 1/10mm
0 1/10 mm
x:
F1
F4
F2
F3
TOGGLE
RPY
BC/HC
F5
]
Press the [F1] function key until the tool No. that you wish to save the new tool
under is displayed.
]
The screen will be changed after pressing the [F3] function key.
401 :
Enter tool (TCP)
Head
X : 0 1/10 mm
|
a : 0 1/10 mm
y : 0 1/10 mm
|
b : 0 1/10 mm
Z : 0 1/10 mm
|
c : 0 1/10 mm
Tool no: 1
| Enter sequence No :
Enter the seq. Number for calculation !
Automic tool TOGGLE
No+/Axis+/TCP
RPY
BC/HC
F1
F2
F3
F4
F5
]
The cursor blinks beneath the input field for the sequence -No. Now enter the
reference sequence -No. under which the two point teaching was made. Only
reference sequences with 2 points are permitted.
]
Press the [Return] key to start the automatic calculation. The calculated
values for x, y & z will be displayed and saved.
]
Press the [Esc] key to exit the menu.
Page: 14-126
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Automatic determination of the tool orientation (RPY-angle)
Due to this determination process the tool will be turned using the robot head coordinates system, in order to clearly simplify a precise program correction as well as
handling (using joystick) in cartesian traversing with complicated tool geometry!
If the robot is traversed in the head co-ordinates system, the effective direction will be
in the +Z - co-ordinate direction.
Ko
p fkoco-ordinates
o rd ina te n syste
m m itwith
W irkroperating
ic htun g + direction
Z
Head
system
+Z
+ X
+ Y
-Y
+ Z
-X
Without the correction to the RPY (a, b, & c) orientation angle, the robot with the
flanged tool will retain the effective direction of the head co-ordinates systems and
corresponding tool movement. For robot applications such as the spreading of
adhesive there is an optimisation option in the effective direction of the tool for the
decisive benefit of the application (e.g. distance adhesive dispenser -> tool piece).
Operating direction:
Adhesive pistol:
adhesive spreading direction
07.03.02
Elektroplanung-und Anlagenbau
Page:14-127
VRS 1
Example for an adhesive pistol
By entering the orientation angle the robot head co-ordinates system will be positioned
in the tool co-ordinates system (adhesive pistol). The cartesian traversing is now made
in the effective tool direction.
+ Y
Robot
W irkricoperating
h tun g
direction
Ro b o te r
+ X
-X
-Y
+ Z
+ X
-Y
+ Y
+ Z
-X
W irkr
ic h tun g
Tool
operating
direction
W e rkze u g
After fitting the tool to be measured a 2 point reference sequence must be
programmed.
Teaching a reference sequence
] Select [Hand] mode in the main menu. Use the [F1] function key to select the
teaching menu.
]
Enter any unused sequence-No.
]
Press the [F1] function key.
]
Traverse using the TCP to a point on an edge (e.g. table edge) so that the
effective direction of the tool lays parallel to the edge.
]
Press the [F2] function key to teach this reference point as point "0" of the
reference sequence.
]
Use cartesian traversing (in conjunction with the [Joystick] key) to traverse to
a second point on the edge. The effective direction of the tool must be
retained and lay parallel to the assisting edge. This point lay at the greatest
possible distance from the first point.
]
Press the [F2] function key to teach this reference point as point 1 of the
reference sequence.
]
Press the function key [F4] in order to finalise the reference sequence.
]
Press the [Esc] key to exit the menu.
Automatic calculation of the tool orientation
If the reference sequence was taught using 2 points, the orientation settings for the tool
can be determined from them.
Page: 14-128
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Select constant No. 401 an. The following menu will be displayed:
401 :
Enter tool (TCP)
Head
X : 0 1/10 mm
|
a : 0 1/10 mm
y : 0 1/10 mm
|
b : 0 1/10mm
Z : 0 1/10 mm
|
c : 0 1/10 mm
Tool no: 1
| Enter axis x :
Modified TCP affects sequence:
Automic tool TOGGLE
No+/Axis+/TCP
RPY
BC/HC
F1
]
F2
F3
F4
F5
Press the [F1] function key until the tool-No. that you wish to save the new
tool under is displayed.
401 :
Enter tool (TCP)
Head
X : 0 1/10 mm
|
a : 0 1/10 mm
y : 0 1/10 mm
|
b : 0 1/10mm
Z : 0 1/10 mm
|
c : 0 1/10 mm
Tool no: 1
| Enter sequence No :
Enter the seq. Number for calculation !
Automic tool TOGGLE
No+/Axis+/TCP
RPY
BC/HC
F1
F2
F3
F4
F5
]
Press the [F4] function key to change the screen.
]
The cursor blinks beneath the input field for the sequence-No. Enter the
reference sequence-No., which was used for the two point teaching.
]
Press the [Return] key and the automatic calculation will be started. The
calculated angles (a, b & c) will be displayed and saved.
]
Press the [Esc] key to exit the menu.
Example: a reference sequence
Pu
nkt 11
Point
Point
Pu
nkt 00
Kle b e r-A u strittsriAdhesive
c h tu n g =
W irkric h tu n g W espreading
rkze u g
A straight edge (e.g. edge table) can be used here as help.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-129
VRS 1
402 Tool loading data
Hand-F2-F4-F3
At the moment this constant does not have any significance in the controller. After the
implementation of a dynamic model, the load data for each tool can be determined.
402 :
Tool loading data
Tool number
:
Distance in z - direction :
Radius of ideal z–R.
:
Loading weight
:
1
0 mm
0 mm
0 kg
+No.
-No.
z
r
Load
F1
F2
F3
F4
F5
]
Press the [F1] or [F2] function keys to select the relevant tool-piece
]
Press the [F3] or [F4] function keys to enter the ideal state for the flange
]
Press the [F5] function key and you will be asked to enter a load
Page: 14-130
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
403 Calibration plate position for tool-piece determination
It is possible to optimally measure (with the help of a predefined calibration plate) the
following tool-pieces using this method of tool-piece measurement:
Laser optics
Jet nozzles
Adhesive nozzles
]
The following menu is displayed after constant 403 has been selected:
403 :
Calibration plate position for tool-piece
A1:
A4:
A2:
A5:
A3:
A6:
Impact direction :
Z+
Rotary direction :
0 degree
Cal. position
Import Impact dir.
Angle
Delete
F1
F2
F3
F4
F5
The function keys have the following significances:
[F1] = Import cal. position
Imports the current robot axis angle
[Shift] + [F1] = Import cal. position
Imports the calibration plate position from an X sequence and point Y.
[F2] = Impact direction
The impact direction can be freely selected.
[F3] = Angle
Any rotation angle required can be entered here.
[F4] = Delete
Use this to delete the entered data
07.03.02
Elektroplanung-und Anlagenbau
Page:14-131
VRS 1
Procedure:
Place the calibration plate in a suitable position. The position should be selected
so that the centre point of the calibration plate can be found by the tool-piece
e.g. soldering optic, and the forward movement direction of the soldering optic
corresponds to the X+ direction of the head coordinates system.
Remove the magnet from the calibration plate
Traverse the robot into a position whereby there is 2 1/10 mm of free “space”
between the robot flanges and the calibration plate
Enter the predefined mass of the calibration plate as the REF tool-piece (TP 8)
(e.g. the calibration plate for LSV 25: Z = 50 1/10 mm)
Traverse the robot, without the tool-piece, up to the calibration plate.
Calibration plate
Y+
X+
Robot impact direction
Z+
Either import the current robot axis angle using the [F1] function key or use [Shift]
+ [F1] to import the calibration plate position from an X sequence & point Y.
Fit the original tool-piece and traverse the robot with its new TCP up to the crosshairs on the calibration plate
The original tool-piece can now be measured automatically by pressing [Shift] +
[F3] in constant 401.
Page: 14-132
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Teaching a calibration plate positioning sequence:
Teach an x sequence with 2 points so that the centre point of the robot flange is
registered with the “Cross-hairs” on the calibration plate.
The robot tool-piece must never touch the plate!
]
The following menu is displayed after selecting constant 403 and
simultaneously pressing the [Shift] + [F1] function keys:
403 :
Calibration plate position for tool-piece
Import calibration plate position from sequence
b Sequence No. :
0
Point No.
:
0
Sequence
F1
Point
F2
F3
F4
F5
]
Press [F1] to select the previously taught sequence
]
Use [F2] to select the point where the cross-hairs on the calibration plate and
the robot flanges register.
]
This data will be imported as the current robot coordinates after the sequence
and the point number have been selected.
]
Fit the original tool-piece and traverse the robot with its new TCP to the crosshairs on the calibration plate
]
The original tool-piece can now be measured automatically by pressing [Shift]
+ [F3] in constant 401.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-133
VRS 1
420 - 439 Sensor constants
Hand-F2-F5-F1
Up to 15 sensors (S1 - S15) can be set and evaluated in the controller.
Modifying the sensor constants is only possible in conjunction with
a key disc!
]
Place the key disc in the controller disc drive.
]
Select die [Hand] operating mode, press the [F2], [F5] and [F1] function keys.
The following menu will be displayed:
420 - 439 : Sensor constants
F1 = Sensor activation
F2 = Load sensor
F3 = Sensor constants
420
421
422
Input :
F1
F2
F3
F4
F5
420 Switching on and off sensor functions
Hand-F2-F5-F1-F1
Switching on:
The switching on of the respective sensors will first activate the relevant sensor
commands already programmed in a sequence!
Switching off:
Due to the switching off of a defined sensor, sequences with programmed sensor
functions can also be traversed without active sensors.
] Select constant No. 420. The following screen showing the sensors that are
already switched on will be displayed.
420 :
Sensor activation
Sensors already switched on:
Press ESC to abort
Input S-No:
(1 - 15)
+ = switch on
- = switch off
F1
Page: 14-134
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
Switching on a sensor:
] Enter the required sensor-No.
]
Press the [+] key.
]
Confirm the entry by pressing the [Return] key. The sensor-No. for the
switched on sensor will be displayed.
Switching off a sensor:
] Enter the required sensor No.
!
]
Press the [-] key.
]
Confirm the entry by pressing the [Return] key.
The switched off sensor-No. will be deleted.
Switching the sensors on or off can be carried out via the “Sensor module”
service program as from Version 2.0.
421 Loading the sensor module
Hand-F2-F5-F1-F2
The instructions and data required for the individual interfacing of sensors to the robot
controller are set up separately in a sensor module that is loaded into the controller via
a floppy disc. This is carried out via the 'LOAD SENSOR' function.
!
Loading the sensors can be carried out via the “Sensor module” service
program as from Version 2.0.
Sensor module:
This module contains the following components (as well as others):
• Module name
• Instructions for the data traffic between sensor and robot controllers
• Instruction for controlling the robots
• Sensor specific data (constants)
• Sensor error report
A listing of the presently available sensor modules can be found in chapter 15
"Auxiliary modules".
Modifying the sensor module is only possible in conjunction with a
key disc!
07.03.02
Elektroplanung-und Anlagenbau
Page:14-135
VRS 1
]
Place the key disc in the controller disc drive.
]
Select constant No. 421 an. The following screen will be displayed.
421 :
Load sensors
Module name : - - -
Load
F1
]
!
F2
F3
F4
F5
Press the [F1] function key. The entire sensor module will be transferred to the
controller. The loaded module name will be displayed.
Important note
The sensor module will only be activated after a new start of the robot system.
]
Press the [Reset] key on the CPU or switch off the control cabinet for a
minimum of 10 sec.
422 Sensor module constants
Hand-F2-F5-F1-F3
The sensor specific data (constants) defined in the sensor module can be:
• Displayed
• Corrected
• Saved to a floppy disc and can be read at any time
These are valid for all sensors (S1 - S15) defined in the module.
]
Select constant No. 422. The following screen will be displayed.
422 :
C1:
C3:
C5:
C7:
C9:
Constants for sensor No:
C2:
C4:
C6:
C8:
C 10 :
C+
C-
F1
F2
Sensor+ Sensor-
F3
F4
Floppy
F5
The sensor-Nos. for the relevant constants (they can also be corrected now) are
displayed here.
Page: 14-136
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
[F1]
K+
The cursor is positioned on the constant input field C1 and this key can move it
forwards via C2 up to C10.
[F2]
KThe same function is carried out here, but in reverse.
[F3]
Sensor+
The displayed sensor No. will be increased by 1.
[F4]
SensorThe displayed sensor No. will be decreased by 1.
[F5]
!
Floppy disc
Read from or save to the floppy disc.
Please pay attention to the supplied documentation, as a wrong sensor constant
can result in the system being damaged.
You can save the sensor constants for the current selected sensor-No. to a constant or
sequence disc or load them from a disc.
!
Saving the sensors can be carried out via the “Sensor module” service
program as from Version 2.0.
]
Select constant No. 422.
]
Use [F3] or [F4] function keys to select the sensor-No. that you wish to load or
save.
Constants for sensor-No.:
1
Floppy : PDOS - disc
Load
F1
]
Save
F2
F3
Verify
F4
F5
Press the function key [F5]. The following menu will be displayed:
07.03.02
Elektroplanung-und Anlagenbau
Page:14-137
VRS 1
!
]
Press the [F1] function key in order to load the sensor constants for the
selected sensor-No. from the disc or
]
Press the function key [F3] in order to save the sensor constants for the
selected sensor-No. to the disc or
]
Press the function key [F5] in order to verify the present sensor constants for
the selected sensor-No. against those on the disc.
Reading, saving or verifying only applies to the selected sensor-No.
Page: 14-138
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
460 - 479 Trajectory module constants
]
Hand-F2-F5-F2
The following screen will be displayed after selecting the [Hand] operating
mode and pressing the [F2], [F5] and [F2] function keys:
460 - 479 : Trajectory pl. constants 1
F1 = Alternate inv. kin. transf.
460
F2 = Add. axis transformation (AATF)
461
F3 = AATF constants
462
F4 = Transformation module
463
(464 - 468)
F5 = Continue
Input :
F1
F2
F3
F4
F5
Modifying the trajectory module constants is only possible in
conjunction with a key disc!
460 Alternate inverse transformation (AIT)
Hand-F2-F5-F2-F1
A robot having a 3 axes hand (axis 4, 5 & 6) has a problem area due to its joining
position.
If axis 5 is in the marking position, the rotational axes 4 and 6 will align. This is
identified as a critical hand position.
Trajectory module l offers two options for traversing this area, with or without the socalled substitute inverse transformation (AIT).
When traversing without AIT the programmed trajectory and orientation will be
retained, but axes 4 + 6 will be turned by 180 degrees against each other. As the
trajectory velocity cannot normally be maintained with this severe turning, the program
will reduce it to the necessary amount. This loss of velocity is intolerable for many
application tasks.
When traversing using ASIT there follows a sign change for axis 5. The same retained
velocity and true trajectory can quickly result in a reduced orientations error.
A xis 4
C ritic a l
ha nd p o sitio n
A xis 6
A xis 5 in
m a rkin g p o sitio n
Flo w line
07.03.02
Elektroplanung-und Anlagenbau
Page:14-139
VRS 1
]
Select constant No. 460 an. The following input menu will be displayed.
460 :
Alternate IKT
Default :ON
Press ESC to abort
On
Off
F1
F2
F3
F4
F5
]
Use the [F1] function key to switch on the substitute inverse transformation
and
]
Use the [F2] function key to switch substitute inverse transformation off.
461 Additional axes transformation (AATF)
Hand-F2-F5-F2-F2
The basic controller is supplied having a 6 axes trajectory control system for articulated
arm equipment. As soon the trajectory controller uses more than 6 robot axes, the
robot will have a greater degree of freedom than is necessary. The equipment is then
over-dimensioned.
6 robot axes
=
=
6 robotic degrees of freedom
6 cartesian degrees of freedom (X, Y & Z plus 3 orientation
angles a, b & c)
Due to the use of additional axes transformation the superfluous degree of freedom is
integrated into the interpolation so that a trajectory traversing is possible without having
to reduce the various performance characteristics (corner creeping, weaving etc.).
The additional axes transformation is individually aligned for each application case and
is loaded into the robot controller via disc in the form of a module.
In the case of an application that no longer requires the additional axes, the loaded
AATF module can be switched to 'passive = ineffective'.
A listing of the additional axes transformation modules available at the
moment can be found in chapter 15 "Auxiliary modules".
Modifying the additional axes transformation is only possible in
conjunction with a key disc!
Page: 14-140
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Select constant No. 461 an. The following input menu will be displayed.
461 :
Add. Axis TransFormation (AATF)
Module name : DUMMY
(PASSIVE)
Modifying will affect the sequences
LOAD
F1
]
ACTIVE
F2
PASSIVE
F3
F4
F5
The following text will be displayed after pressing the [F1] function key:
Please put the system disc in the drive.....
and acknowledge using F1 !
F1
F2
F3
]
Put the AATF system disc in the drive.
]
Press the [F1] function key.
F4
F5
The module will be loaded and the following screen will be displayed:
461 :
Add. Axis TransFormation (AATF)
Module name : RED 7/8
(PASSIVE)
Modifying will affect the sequences
LOAD
F1
ACTIVE
F2
PASSIVE
F3
F4
F5
The name RED 7/8 is used here as an example to identify the loaded module and it is
set to PASSIVE.
] Press the [F2] function key to activate the module.
!
Important note:
After loading the AATF module the robot system must be restarted. Press the
reset key on the CPU or switch off the control cabinet for a minimum of 10 sec.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-141
VRS 1
462 AATF constants
Hand-F2-F5-F2-F3
With prior agreement, up to 10 free parameters can be entered here for each
individually processed AATF module. The significances of the parameters are
documented in the instructions for the module.
Modifying the constants is only possible in conjunction with a key
disc!
]
Select constant No. 461 and press the [F2] function key. The following input
menu will be displayed.
462 :
AATF constants:
C1:
0
C2:
0
C3:
0
C4:
0
C5:
0
C6:
0
C7:
0
C8:
0
C9:
0
C 10 : 0
Modifying C1 – C10 affects the sequences
C+
C-
F1
F2
F3
F4
F5
[F1]
K+
The cursor is positioned on the constant input field C1 and this key can move it
forwards via C2 up to C10.
[F2]
KThe same function is carried out here, but in reverse.
463 Transformation module
Hand-F2-F5-F2-F4
The basic controller is supplied with a trajectory control system for articulated arm
equipment. If equipment with different kinematics is being used, the relevant trajectory
control can be loaded via a transformation module.
This transformation module for the respective kinematics is processed on an external
computer and loaded by disc into the controller.
A listing of the transformation modules available at the moment can be found
in chapter 15 "Auxiliary module".
Modifying the constants is only possible in conjunction with a key
disc!
Page: 14-142
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
]
Select constant No. 463. The following input menu will be displayed.
463 :
Transformation module
Module name : - - -
LOAD
F1
]
!
F2
F3
F4
F5
Put the floppy disc in the drive and press the [F1] function key. The
transformation module will be loaded. In addition, the programmed name of
the module will also be displayed.
Important note
After loading the AATF module the robot system must be restarted. Press the
reset key on the CPU or switch off the control cabinet for a minimum of 10 sec.
464 Kinematics in the [Hand] operating mode
Hand-F2-F5-F2-F5-F1
For special requirements a selection of the active (mathematically interfaced) additional
axes (kinematics) is necessary. The selection of the current additional axes is made via
the kinematic-No. (No. 0-9). Normally kinematic No. 0 is pre-selected. This has no
affect on the programmed sequence.
The selection of a kinematic No. (1 - 9) is only of use when made in conjunction with a
special AATF module.
When teaching a movement sequence you must ensure that the correct kinematics-No.
has been selected. Only then will the movement sequence traverse correctly in
[Automatic] or [Single Step] operating modes.
]
In order to modify the kinematic No. select constant No. 464 in the [Hand]
operating mode. The following input menu will be displayed:
464 :
Kinematic default for TEACHING
Minimum : 0
Maximum : 9
Default :
0
Only of use in conjunction with an
AATF module (constants 461 & 462)
Input :
F1
07.03.02
F2
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:14-143
VRS 1
]
Enter the required kinematic No. (0 - 9).
]
Confirm the entry by pressing the [Return] key.
]
Press the [Esc] key to exit the menu.
Pre-selected kinematic No. will be displayed in the main menu for the [Hand] operating
mode beneath the current tool No. (kinematic No. 0 will not be displayed).
H A N D mode
Ei1..6
F1 = TEACHING
F2 = MODIFY CONSTANTS
F3 = TEST
F4 = SERVICE PROGRAM
F5 = OVERVIEW
F1
F2
F3
F4
100% Z1
Tool 1
Kinematic 2
F5
465 Loading the S-P- module
Hand-F2-F5-F2-F5-F2
The loading of a sub-program generating module is identical to the loading of other
modules.
465 :
Load special S-P module
Module name : - - -
LOAD
F1
F2
F3
F4
F5
A listing of the sub-program generating module available at the moment can
be found in chapter 15 "Auxiliary modules".
!
Special S-Ps can now be loaded via the “sensor module” service program as
from Version 2.0 onwards.
Page: 14-144
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
466 Accuracy ball parameters
Hand-F2-F5-F2-F5-F3
The matching of the radius and velocity parameters against over looping can be made
via these constants.
466 :
Matching the traversing in the point
F1 = Radius matching
= FALSE
F2 = Velocity matching
= TRUE
TRUE
F1
FALSE
F2
F3
F4
F5
Radius matching
Use this parameter to set whether the looping radius should be modified to be
dependent on the velocity override (TRUE) If the radius matching is switched off
(FALSE), then the TCP will loop so regardless of the velocity override.
Velocity matching
Use this parameter to set whether the programmed velocity should be reduced to the
same dimensions as the looping radius (TRUE), if this results in over cutting of the
programmed accuracy ball (45% criteria).
07.03.02
Elektroplanung-und Anlagenbau
Page:14-145
VRS 1
467 Loading the robot model
Hand-F2-F5-F2-F5-F4
At the moment there are no dynamic robot models for the VRS controller.
467 :
Robot model
Module name : Dummy model
LOAD
F1
ACTIVE
(PASSIVE)
PASSIVE
F2
F3
F4
F5
468 Velocity profile selection
Hand-F2-F5-F2-F5-F5
The robot mechanics require a filter function so that they will not vibrate during
traversing. This filter function will smooth the velocity profile during both the
acceleration and the braking phases. With a sinus profile the robot -mechanics will
produce a severe overshoot response to a short path as compared to a parabolic
profile. For spot welding applications it is therefore an advantage to switch the velocity
profile to parabolic.
]
Select constant type 468:
468 :
Velocity profile selection
Profile shape :
Sinus
Parabolic
F1
]
F2
F3
F4
F5
Use the [F1] function key to select parabolic.
In order to attain a better cycle time the filter value must be reduced to 80 %.
The value of 80 % is dependent on the robot mechanics being used.
When the default filter value is reduced an overshoot measurement with the robot
mechanics being used must be carried out.
Page: 14-146
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
480 Hand console (teach box) language
Hand-F2-F5-F3
The controller can display the text in German, Spanish, English, Portuguese, Czech
and Slovakian.
]
The following menu will be displayed after selecting constant No. 480:
480 :
Teach box language
Default setting : German
Press ESC to abort
German
F1
Spanish
F2
English
F3
Portug.
F4
F5
]
Select the required language by pressing the relevant function key.
]
[F2]
Spanish
480 :
Idioma
Valor actual :
Español
Cancelar con ESC
]
[F3]
Aleman
Español
Ingles
Portug.
F1
F2
F3
F4
F5
English
480 :
Teach box language
Default :English
Press ESC to quit
German Spanish
F1
07.03.02
F2
English
Portug.
F3
F4
F5
Elektroplanung-und Anlagenbau
Page:14-147
VRS 1
]
[F4] Portuguese
480 :
Idioma de consola manual
Pre-ajuste : Portuguese
Cancelar com ESC
]
Aleman
Espanol
F1
F2
Ingles
F3
Portug.
Continue
F4
F5
[F5] Continue, other languages will be displayed
480 :
Teach box language
Default setting : German
Press ESC to abort
]
Czech
Slovakian
F1
F2
Continue.
F3
F4
F5
[F1] Czech
480 :
Jazyk ruc. panelu
Prednastaveni : cestina
Ukonceni s ESC
Nem.
F1
]
Spanel.
Anglic.
Portug.
F2
F3
F4
Dale
F5
[F2] Slovakian
480 :
Jazyk ruc. panelu
Prednastavenie : slovencina
Ukoncenie s ESC
Nem.
F1
]
Spaniel.
Anglic.
Portug.
F2
F3
F4
Dalej
F5
Use the [ESC] key to confirm the language selection. The text will now be
displayed in the selected language. The respective language remains active
until another is selected.
Page: 14-148
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
HAND-F2-F5-F4
490 The free running PLC
PLC (SPC) = Stored Program Controller forms an automatic system for controlling,
monitoring, collecting and processing of data as well as providing communications and
other process related tasks. The controller operates via an integrated mini-PLC, i.e. this
stored program controller does not exist as a customary additional hardware module,
but the PLC instructions are programmed in the [Hand] operating mode and are
executed by the controller as point related or free running instructions in the
[Automatic] and [Single Step] operating modes.
The free running PLC can, provided that it has been set to do so, supplement the point
related PLC, as well as administering individual controlling tasks. As opposed to a point
related PLC, the instructions are repeated, i.e. cyclically executed. This makes the free
running PLC especially suitable for monitoring and controlling point independent
system statuses (e.g. full level monitoring of adhesive supply containers).
The PLC instructions are programmed in the [Hand] operating mode in the constants
menu using constant type 490 and automatically executed with the selection of the
Automatic or Single Step operating modes. A free running PLC program will only be
stopped when the operating mode is changed to the [Hand] mode.
A total of 13 different free running PLC-Programme can be programmed in the VRS 1,
however only one PLC program can be executed at a time. The command syntax for
the free running PLC is normally identical to the command syntax used for the point
related VRS1-PLCl. Commands, that work directly in conjunction with the robot TCPs,
e.g. traversing conditions, gripper functions, wait conditions and jump conditions,
cannot be used with the free running PLCs.
With the exception of the PLC marker, all PLC operands for the point related PLCs and
the free running PLCs are identical. This includes: outputs, inputs, flags, sensor flags,
timer, counter and binary outputs.
The programmer must ensure that these operands are not used twice (from the point
related and the free running PLC).
]
In order to program the free running PLC select constant No. 490. The
following screen will be displayed:
Following PLC programs are programmed :
1
Current program number :
1
Edit
Copy
Delete
Cycle
time
F1
F2
F3
F4
F5
Read "The free running PLC" section in chapter 9 "PLC Programming" for
further information regarding this.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-149
VRS 1
Hand-F2-F5-F5
500 PLC-Operands
In the controller it is possible to add commentaries for the individual PLC operands
(e.g. inputs, outputs etc.). These are, for example, for programmed PLC wait or
traversing conditions for the running time of the movement sequence and will be
displayed on the hand console screen.
If no commentaries are to be allocated to the PLC operands, the following line will be
displayed during a wait condition, e.g.:
Wait for: I12 & I2
If the inputs are to be allocated commentaries, the following line will be displayed for
the same wait condition:
Wait for: Temperature contact 1 & ready contact
With this documentation option you can prevent any visual dual loading of a marker or
a flag. Document each PLC operand that is used, in which you have allocated a
commentary. Keep the current print out of the allocations list by the controller.
Select constant No. 500 for entering the PLC commentary. The following
screen will be displayed:
]
DOCUMENTATION for PLC OPERANDS
I1 = --I2 = --I3 = --I4 = --i5 = --I6 = --EDIT
FLOPPY
SWITCH
F1
F2
F3
F4
F5
The following types of operands can be allocated to any commentary:
•
•
•
•
•
•
Inputs
Outputs
Marker
Sensor flags
Flags
Timer
Read the "500: editing PLC operands" section in chapter 14 "Modifying the
constants" for more information regarding this
Page: 14-150
Elektroplanung-und Anlagenbau
07.03.02
VRS 1
555 Setting the system clock time
This is a newly developed functionality included in the VRS1 controller from version
1.13 and requires more computer time than previously. In order to guarantee a
program run without any breakdowns, the system clock time must be increased from
15 ms to 20 ms as from version 1.13. With a system clock time of 20 ms a vibration
free traversing can be guaranteed even with unfavourable robot constellations.
Modifying the constants is only possible in conjunction with a key
disc!
]
Select constant No. 555 in order to enter the system clock time. The following
screen will be displayed:
555 :
Adjust cycle time
Adjusting :
15 ms
F1
]
15 ms
20 ms
25 ms
F2
F3
F4
F5
Restart the system after the modification has been made!
Stopping the load conditions
If to many PLC instructions were previously programmed in the point related PLC, it
could occur that the robot began to vibrate, as it was so busy processing the PLCs.
Because of the present additional possibility to program loops in the PLC, realised
through jumps, this can result in an increase in such vibrations, caused by wrong
programming. As from version 1.11 such errors were intercepted by an PLC check that
was carried out in the previous point. If there are too many PLC instructions and
markers programmed in the point being traversed to, the robot will brake when entering
the accuracy ball until the additional PLC instructions have been processed. If a neverending loop has been programmed the robot will stop and the report "Inclusive PLC
instruction" will be generated on the hand console. The new stopping the load
conditions performance characteristic is only to prevent the robot from vibrating due to
a programming error. The programming instructions with the defaults for the number of
markers and PLC instructions are kept so that the clock time can be guaranteed.
07.03.02
Elektroplanung-und Anlagenbau
Page:14-151
VRS 1
556 Setting the PLC - load
Depending on the robot model and the programmed program runs, the robot can
execute a specific number of PLC instructions in a TCP, which were taught using
accuracy and point velocity not equal to zero. With the options now available for use in
version 1.13, more PLC instructions can be programmed than the controller can
process. For this reason the known load conditions resulted in braking in version 1.12.
With this constant you can set the number of PLC instructions that will be processed
before the braking. The PLC instructions are therefore sub-divided over several cycles.
When the controller has finished processing the PLCs, the robot will accelerate to the
programmed velocity again.
Select constant No. 556. The following screen will be displayed:
]
556 :
PLC load settings
Number of PLC instructions : 10
Input :
Number
F1
F2
F3
F4
]
Enter the required number of PLC instructions.
]
Confirm the entry by pressing the [Return] key.
]
Press the [Esc] key to exit the menu.
F5
The default value of 15 guarantees a vibration free program run. Should the robot
begin to vibrate when entering the programmed accuracy ball due to a multitude of
PLC instructions, the value should be reduced. In some application cases the value
can also be increased, however this must be individually checked for each application
case.
Page: 14-152
Elektroplanung-und Anlagenbau
07.03.02
Скачать