CO2 CO2 sensors ACCESSORIES RCO2-D-F2 RC02-F2 KCO2 The self-calibrating microprocessor-controlled room and duct CO2 sensors are used for the detection of the CO2 content in air within a range of 0 ppm to 2000 ppm CO2. The measurement signals generated by the CO2 transmitter are FRQYHUWHGLQWRVWDQGDUGVLJQDOVRI±97KH&2FRQWHQWLQWKH air is determined by a NDIR sensor (non-dispersive infrared technology sensor). The detection range of the CO2 sensor is calibrated for standard applications such as monitoring of apartment rooms or meeting rooms. Room ventilation on an as-needed basis, improvePHQWRIZHOOEHLQJDQGFXVWRPHUEHQH¿WLQFUHDVHGFRPIRUWDVZHOO as a reduction of operating costs by saving energy. 0LNURSURFHVRULDXV SDJDOED VDYDLPH VXVLNDOLEUXRMDQWLV NDPEDULQLV LU NDQDOLQLV &2 MXWLNOLV QDXGRMDPDV RUR &2 O\JLRQXVWDW\PXLUHLNãPơVHSSP±SSP&2&2 O\JLVRUHQXVWDWRPDVQDXGRMDQW1',5MXWLNOƳQRQGLVSHUVLYHLQIUDUHG technology sensor). CO2 aptikimo lygis sukalibruotas gyvenamoVLRPVLUVXVLULQNLPǐDUEDSDQDãLRPVSDWDOSRPV9ơGLQLPDVSDJDO SRUHLNƳ ± JHUHVQơ VYHLNDWD NRPIRUWDV EHL HQHUJLMRV LãODLGǐ PDåLnimas. 6DPRNDOLEUXMąF\VWHURZDQHPLNURSURFHVRUHPSRNyML&2 F]XMQLNL NDQDáRZH Vą VWRVRZDQH GR Z\NU\ZDQLD &2 ]DZDUWRĞüSRZLHWU]DZ]DNUHVLHRGGRSSPSSP&2 6\JQDá\ JHQHURZDQH SU]H] SRPLDU &2 QDGDMQLND Vą SU]HOLF]RQH QD VWDQGDUGRZ\FK V\JQDáyZ 9 ]DZDUWRĞFL &2 Z SRZLHWU]D MHVW RNUHĞORQD SU]H] F]XMQLN 1',5 QRQG\VSHUV\MQH WHFKQRORJLL SRGF]HUZLHQL F]XMQLND =DNUHV GHWHNFML F]XMQLND &2 MHVW NDOLEURZDQ\ GOD VWDQGDUGRZ\FK DSOLNDFML WDNLFK MDN PRQLWRURZDQLH SRPLHV]F]HĔ PLHV]NDOQ\FK OXE VDOH NRQIHUHQF\MQH :HQW\ODFMD QD PLDUĊ SRWU]HE SRSUDZD GREURE\WX L NRU]\ĞFL NOLHQWD ZLĊNV]\NRPIRUWRUD]MDNR]PQLHMV]HQLHNRV]WyZRSHUDF\MQ\FKSRSU]H] RV]F]ĊGQRĞFLHQHUJLL ɋɚɦɨɤɚɥɢɛɪɭɸɳɢɣɫɹɭɩɪɚɜɥɹɟɦɵHɦɢɤɪɨɩɪɨɰɟɫɫɨɪɨɦ ɞɚɬɱɢɤɢɭɝɥɟɤɢɫɥɨɝɨɝɚɡɚ&2ɢɫɩɨɥɶɡɭɸɬɫɹɜɩɨɦɟɳɟɧɢɢ ɢɜɜɨɡɞɭɯɨɜɨɞɚɯɢɫɥɭɠDɬɞɥɹɢɡɦɟɪɟɧɢɹɫɨɞɟɪɠɚɧɢɹ ɜ ɜɨɡɞɭɯɟ ɭɝɥɟɤɢɫɥɨɝɨ ɝɚɡɚ ɜ ɞɢɚɩɚɡɨɧɟ ɨɬ SSP ɞɨ SSP &2 ɋɢɝɧɚɥɵ ɢɡɦɟɪɟɧɢɹ ɩɪɟɨɛɪɚɡɭɸɬɫɹ ɜ ɫɬɚɧɞɚɪɬɧɵɟ ɫɢɝɧɚɥɵ ± ȼ ɋɨɞɟɪɠɚɧɢɟ ɭɝɥɟɤɢɫɥɨɝɨ ɝɚɡɚ ɜ ɜɨɡɞɭɯɟ ɨɩɪɟɞɟɥɹɟɬɫɹ ɫ ɩɨɦɨɳɶɸ ɧɟɞɢɫɩɟɪɫɧɨɝɨ ɢɧɮɪɚɤɪɚɫɧɨɝɨ ɚɧɚɥɢɡɚɬɨɪɚ 1',5 Ⱦɢɚɩɚɡɨɧ ɱɭɜɫɬɜɢɬɟɥɶɧɨɫɬɢ ɞɚɬɱɢɤɚ ɭɝɥɟɤɢɫɥɨɝɨɝɚɡɚɨɬɤɚɥɢɛɪɨɜɚɧɜɪɚɫɱɟɬɟɧɚɫɬɚɧɞɚɪɬɧɵɣɫɥɭɱɚɣ ɩɪɢɦɟɧɟɧɢɹ ± ɞɥɹ ɠɢɥɵɯ ɩɨɦɟɳɟɧɢɣ ɤɨɧɮɟɪɟɧɰɡɚɥɨɜ ɢ ɬɞ ȼɟɧɬɢɥɹɰɢɹɩɨɦɟɪɟɧɟɨɛɯɨɞɢɦɨɫɬɢɭɥɭɱɲɟɧɢɟɫɚɦɨɱɭɜɫɬɜɢɹ ɞɨɩɨɥɧɢɬɟɥɶɧɚɹɜɵɝɨɞɚɭɥɭɱɲɟɧɧɚɹɤɨɦɮɨɪɬɧɨɫɬɶɢɫɧɢɠɟɧɢɟ ɷɤɫɩɥɭɚɬɚɰɢɨɧɧɵɯɪɚɫɯɨɞɨɜɛɥɚɝɨɞɚɪɹɷɧɟɪɝɨɫɛɟɪɟɠɟɧɢɸ Technical data: Type RCO2-F2 Measuring range, CO2 RCO2-D-F2 0...2000 ppm 0...2000ppm, 0...5000ppm, 0...10000ppm 9 Output CO2 Power supply 9$&'& Ambient temperature 0...+50 0C Display Dimension Protection type Installation 182 KCO2 No Yes No 98x106x32 108x73,5x70 IP30 IP65 :DOOPRXQWLQJRULQZDOOÀXVK box, 55mm Duct The company reserves the right to make changes of technical data without prior notice