ETegro Fastor JS200 G3 JBOD ETegro Fastor JS200 G3 JBOD Table of Contents 1. Etegro Fastor JS200 G3 JBOD .......................................................................................... 1 1.1. Conventions ........................................................................................................... 2 1.2. Safety Information .................................................................................................. 3 1.2.1. Important Safety Instructions ........................................................................ 3 1.3. Disclaimer .............................................................................................................. 4 2. About JBOD ...................................................................................................................... 5 2.1. Introduction ............................................................................................................ 6 2.2. System Features .................................................................................................... 7 2.3. Package content ..................................................................................................... 9 2.4. System requirements ............................................................................................ 10 2.5. JS200 G3 Front View ........................................................................................... 11 2.6. JS200 G3 (Dual SIM) Rear View ........................................................................... 12 2.7. JS200 G3 Rear LED Descriptions .......................................................................... 13 2.8. Disk Drives and Tray ............................................................................................ 14 3. Install/Replace HDD ........................................................................................................ 16 3.1. Before You Begin ................................................................................................. 17 3.2. Follow these steps below to Install/Replace HDD in the disk tray. ............................. 18 4. Before You Begin ............................................................................................................ 20 5. Setting up JS200 G3 System ........................................................................................... 21 5.1. Connection type 1(Single SIM) .............................................................................. 22 5.2. Connection type 2(Dual SIM) ................................................................................. 23 6. Power on the JS200 G3 .................................................................................................. 24 7. Management guide .......................................................................................................... 25 7.1. Connect by console .............................................................................................. 26 7.2. Connect by network .............................................................................................. 29 7.3. Firmware upgrade guide ....................................................................................... 31 iii Chapter 1. Etegro Fastor JS200 G3 JBOD 1 Etegro Fastor JS200 G3 JBOD 1.1. Conventions Several different typographic conventions are used throughout this manual. Refer to the following examples for common usage. Bold type face denotes menu items, buttons and application names. Italic type face denotes references to other sections, and the names of the folders, menus, programs, and files. <Enter> type face denotes keyboard keys. Warning information appears before the text it references and should not be ignored as the content may prevent damage to the device. CAUTIONS APPEAR BEFORE THE TEXT IT REFERENCES, SIMILAR TO NOTES AND WARNINGS. CAUTIONS, HOWEVER, APPEAR IN CAPITAL LETTERS AND CONTAIN VITAL HEALTH AND SAFETY INFORMATION. Indicates information that is important to know for the proper completion of a procedure, choice of an option, or completing a task. Highlights general or useful information and tips. 2 Etegro Fastor JS200 G3 JBOD 1.2. Safety Information 1.2.1. Important Safety Instructions Read all caution and safety statements in this document before performing any of the instructions. Warnings Heed safety instructions: Before working with the server, whether using this manual or any other resource as a reference, pay close attention to the safety instructions. Adhere to the assembly instructions in this manual to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this manual. Use of other products / components will void the UL listing and other regulatory approvals of the product and will most likely result in non-compliance with product regulations in the region(s) in which the product is sold. System power on/off: The power button DOES NOT turn off the system AC power. To remove power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before opening the chassis, adding, or removing any components. Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Otherwise, personal injury or equipment damage can result. Electrostatic discharge (ESD) and ESD protection: ESD can damage drives, boards, and other parts. We recommend that you perform all procedures in this chapter only at an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts. ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to electrostatic discharge (ESD). Hold boards only by their edges. After removing a board from its protective wrapper or from the server, place the board component side up on a grounded, static free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board over any surface. 3 Etegro Fastor JS200 G3 JBOD 1.3. Disclaimer The information in this document is subject to change without notice. The manufacturer makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, the manufacturer reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of the manufacturer to notify any person of such revision or changes. For the latest information and updates please refer to www.etegro.com All the illustrations in this technical guide are for reference only and are subject to change without prior notice. 4 Chapter 2. About JBOD 5 About JBOD 2.1. Introduction This manual is written for system technicians who are responsible for troubleshooting, upgrading, and repairing the JBOD chassis. This document provides an overview of the hardware features of the system, management information, and instructions on how to add and replace components of the JBOD. For the latest version of this manual, see www.etegro.com. 6 About JBOD 2.2. System Features Table 2.1. JS200 G3 Specifications Hardware Features: Enclosure Form Factor 4U Rackmount HDD Support (24) 6Gb/s 3.5" SASII and SATAII Hot-Swap HDDs Host Interface/ per controller (3) 6Gb/s mini-SAS ports (1) RJ11 console port (1) RJ45 management port Expansion Support Scalable up to 72 Disk Drives: support 2 sets JS200 G3 systems daisy chain (total 3 sets of JS200 G3 systems) Power supply 2x 760W redundant PSUs Supported HBA Card See QVL list at www.etegro.com Hot-Swap and Redundancy Controller Module (2) Dual hot-swappable controller modules Disk Drives Hot-swap HDDs (24-bay) Cooling Fans Total 2+2 redundant in the system, 2 fans in each power supply module Power Supply (2) 760W redundant power supplies, input requirements 88 - 264V AC Physical Dimensions Dimensions, mm (H x W x D) 175 x 445 x 557 Weight 29.33kg Environmental Operating temperature 0°C to 40°C (32°F to 104°F) Humidity 50% to 93% relative humidity Altitude 40°C / 3200 Meter Shock 31G@2.6ms [mailto:31G@2.6ms], half-sine shock 0.26Grms random vibration 5~350Hz Vibration FCC- for US and Canada CE- for Europe BSMI- for Taiwan KCC- for Korea EMI/EMC Safety Regulations UL/CUL - for U.S. with Canada/ UL60950-1 7 About JBOD CB (by Demko)- IEC60950-1/ EN60950-1 BSMI- Taiwan/ CNS14336 Monitoring and Notification LED Indicators Power LED System ID/ Status LED HDD Active and ID/ Status LED Management Support SCSI Enclosure Service (SES-2), console port 8 About JBOD 2.3. Package content The JS200 G3 box contains the following items: • JS200 G3 Storage unit (1) • Power cord (2) • CD with user manual and drivers (1) • Universal Rail Kit(1) • 6/4 HDD Screws(96) 9 About JBOD 2.4. System requirements • Servers with supported HBA/Raid adapter, refer to JS200 G3 support matrix reference for complete listing of supported adapters. • SFF-8088 to SFF-8088 SAS cable. 10 About JBOD 2.5. JS200 G3 Front View Figure 2.1. System front view The button at the front of JS200 G3 is only used for locating for JS200 G3 storage with management software and it does not power on/off the system. 11 About JBOD 2.6. JS200 G3 (Dual SIM) Rear View Figure 2.2. System rear view Table 2.2. System Component Overview 1 PSU Module 1 2 PSU Module 2 3 Power Connectors 4 SIM board 1 5 SIM board 2 6 SIM1 SAS IN Connector (SFF-8088) 7 SIM1 SAS OUT Connector (SFF-8088) 8 SIM2 SAS IN Connector (SFF-8088) 9 SIM2 SAS OUT Connector (SFF-8088) 10 SIM1 NET MGT + Service port 11 SIM2 NET MGT + Service port NET MGT ports are for FW upgrade. Service port is for manufactory use only. 12 About JBOD 2.7. JS200 G3 Rear LED Descriptions Figure 2.3. System rear LED Table 2.3. Rear LED function and behavior No Component Color Description 1 AC Power Status Solid Green PS is ON Off No AC Power Off Normal Solid Amber Cooling Fan Failure Solid Green Normal Off No DC Power Off No failure Solid Amber Power Supply Failure Solid Green Connected No activity Blinking Green Accessing SAS OFF Not connected OFF Normal Solid Amber Fault SAS Green SIM is ON Blinking Green SIM is booting Solid Amber Fault SIM SIM Locate Off Normal Blinking White 2 3 4 5 6 7 8 Cooling Fan Power Fault DC Power Status Power Supply Status SAS Link Power SAS Link Status SIM Power 13 About JBOD 2.8. Disk Drives and Tray Figure 2.4. HDD tray 1 HDD Tray 2 Optional Interposer for SATA HDD 3 Disk Tray Handle Figure 2.5. HDD tray front view 1 HDD Activity LED 2 HDD Status LED 3 Release button (Blue) 4 Disk Tray Handle Table 2.4. HDD tray LED function and behavior No Component Color Description 1 HDD Activity LED Solid Blue HDD is ready Blinking Blue Spin up /Accessing Blinking Green Identify HDD Solid Red HDD fault Blinking Orange RAID Resilver/Rebuild Solid Orange Hot Spare 2 HDD status 14 About JBOD Alternate Green/ Orange 15 Scrub/Consistency Check Chapter 3. Install/Replace HDD 16 Install/Replace HDD 3.1. Before You Begin It is not recommend mixing SAS and SATA HDD in the same JS200 G3 system. If you have to, please use the following figures below to plan where you will be placing the disk drives. These figures represent fully-loaded JS200 G3 system with HDD. However, the same guidelines apply even if you are filling some of the HDD slots with blank disk trays in the mix-ing HDD setting. Figure 3.1. Recommended Disk Drive Configurations Figure 3.2. Unsupported Disk Drive Combinations 17 Install/Replace HDD 3.2. Follow these steps below to Install/ Replace HDD in the disk tray. 1. Remove HDD tray a) Press the release button to right and open the disk tray handle. b) Remove HDD carrier by pulling the disk tray handle out. Figure 3.3. HDD carrier remove 2. Insert the HDD inside the tray and tighten the four 6/4 screws on the SATA/SAS disks. Figure 3.4. Different drives If using SATA HDD, please make sure having Interposer card installed on the back of HDD tray. Otherwise there will be functionality problems. 3. Slide in the HD tray back in the disk slot and close the disk tray handle. Figure 3.5. HDD carrier insert 18 Install/Replace HDD 4. Repeat Steps above if you wish to install more HDD into the JS200 G3 storage. 19 Chapter 4. Before You Begin Confirm that there is adequate power at your facility to support the high-availability features of the system. It is recommended to connect each power connector to separate power circuit. If necessary refer to the documentations shipped with the 6Gb/s SAS HBA/RAID card for hardware and driver installation instructions. There are several types of SAS Cables in the market, make sure that you order the right one. For JS200 G3, it all uses SFF-8088 to SFF-8088 SAS Cable when connecting JS200 G3 to host and when daisy chain to another JS200 G3. Figure 4.1. SAS cable 20 Chapter 5. Setting up JS200 G3 System 21 Setting up JS200 G3 System 5.1. Connection type 1(Single SIM) This illustration shows one host with a HBA/RAID card connected to three JS200 G3 with single SIM used. Figure 5.1. One channel architecture 22 Setting up JS200 G3 System 5.2. Connection type 2(Dual SIM) This illustration shows one host with a HBA/RAID card connected to three JS200 G3 with dual SIM. Not All HBA/RAID card support this type of connection please refers to JS200 G3 support matrix reference for complete listing of supported dual port 6Gb/s HBA/RAID cards. Figure 5.2. Dual channel architecture 23 Chapter 6. Power on the JS200 G3 1. Verify that all connections are correct. 2. Turn on both circuit breakers on cabinet. 3. Make sure that power-on LED on all JS200 G3 are steady blue. 4. Power on the server lastly. Please make sure power on all JS200 G3 first before the server. 24 Chapter 7. Management guide 25 Management guide 7.1. Connect by console Please prepare the following items: • RJ45 network cable • Windows machine with Telnet Client like Ayera TeraTerm Pro Web 3.1.3 URL of the download: http://ayera.com/teraterm/ttpro313.zip Login Password : jbodstorage 1. Select COM port 2. Set serial port 26 Management guide 3. Use commands "dhcp" and "ip" to set network "dhcp disable" to disable dhcp. "ip 192.168.36.1" set ip=192.168.36.1 "ip 192.168.36.1 255.255.0.0" set ip=192.168.36.1, mask=255.255.0.0 27 Management guide 28 Management guide 7.2. Connect by network Select TCP/IP and telnet: JBOD provides a basic command line interface (CLI) as an alternative for users to configure their JBOD. In order to use the CLI, users can use the UART or Ethernet port to communicate with JBOD. In host side, user can use a terminal program or telnet/SSH application to communicate with JBOD. In UART port, the baud rate should be set 115200bps. In Ethernet port, the speed can be 10M or 100M. Before entering CLI, user needs to enter the password. Table 7.1. General CLI Command Description Command format ver Show version sas_addr Set/Get SAS address sas_addr disks <base_addr> Show Disk status disks port Show all SAS port status port err_cnt Show all phys error count err_cnt err_clr Clear all phys error count err_clr reboot Reboot SIM reboot ver 29 Management guide enable Enable FRU enable <disk #/ps0/ ps1/peer/up/down> disable Disable FRU disable <disk #/ps0/ps1/peer/ up/down> reset Reset FRU reset who <disk #/ ps0/ps1/ peer> Show Mastership who date Set/Show date date <YEAR> <MON> <DATE> <HR> <MIN> <SEC> status Show System FRU/ state status status rpm Set/Get FAN RPM rpm <1/2/3> syslog Clear/Get System log syslog <clr> sda_show Show SDA count sda_show i2c Show I2c i2c help help Show I2C device ID i2c dev I2C reset i2c reset <all/devID> I2C device read i2c rd devID register I2C device write i2c wr devID register value Dump IIC device content i2c dump <devID/ all> eep_rd Read EEPROM data eep_rd <sim/peer/ mid/ps0/ps1> zoning Show/Toggle physical presence zoning <pp/help> ip Show/Set IP ip ip_addr net_mask address, gateway_addr and Default Net Mask Gateway address dhcp Show/Set DHCP on/off dhcp fru <enable/ disable> Access FRU ID fru <print/setssn/setppn/sync> quit quit exit Exit CLI interface 30 Management guide 7.3. Firmware upgrade guide • Stop all IO to JS200 G3 before upgrade 1. Connect RJ45 network cable from Windows machine to JS200 G3 SIM1 NET MGT port 2. Run Tera Term and connect to 169.254.144.1 by Telnet (preparation procedure described above) 3. Console prompt will show up and type “jobstorage” to enter protected Service Console 31 Management guide 4. Type “fdl 2 0 y” to upgrade the FW 5. Click File→Transfer→XMODEM→Send to transfer the FW 6. Select the FW file 32 Management guide 7. Transfer in process 8. Upgrade completed 33 Management guide 9. Reset JS200 G3 and use “ver” to make sure the FW has been upgraded successfully. 10.Please connect RJ45 network cable to SIM 2 NET MGT port and repeat step 3 to 10 to upgrade SIM2 34