ETegro Fastor JS200 G3 JBOD
ETegro Fastor JS200 G3 JBOD
Table of Contents
1. Etegro Fastor JS200 G3 JBOD .......................................................................................... 1
1.1. Conventions ........................................................................................................... 2
1.2. Safety Information .................................................................................................. 3
1.2.1. Important Safety Instructions ........................................................................ 3
1.3. Disclaimer .............................................................................................................. 4
2. About JBOD ...................................................................................................................... 5
2.1. Introduction ............................................................................................................ 6
2.2. System Features .................................................................................................... 7
2.3. Package content ..................................................................................................... 9
2.4. System requirements ............................................................................................ 10
2.5. JS200 G3 Front View ........................................................................................... 11
2.6. JS200 G3 (Dual SIM) Rear View ........................................................................... 12
2.7. JS200 G3 Rear LED Descriptions .......................................................................... 13
2.8. Disk Drives and Tray ............................................................................................ 14
3. Install/Replace HDD ........................................................................................................ 16
3.1. Before You Begin ................................................................................................. 17
3.2. Follow these steps below to Install/Replace HDD in the disk tray. ............................. 18
4. Before You Begin ............................................................................................................ 20
5. Setting up JS200 G3 System ........................................................................................... 21
5.1. Connection type 1(Single SIM) .............................................................................. 22
5.2. Connection type 2(Dual SIM) ................................................................................. 23
6. Power on the JS200 G3 .................................................................................................. 24
7. Management guide .......................................................................................................... 25
7.1. Connect by console .............................................................................................. 26
7.2. Connect by network .............................................................................................. 29
7.3. Firmware upgrade guide ....................................................................................... 31
iii
Chapter 1. Etegro Fastor JS200 G3
JBOD
1
Etegro Fastor JS200 G3 JBOD
1.1. Conventions
Several different typographic conventions are used throughout this manual. Refer to the following
examples for common usage.
Bold type face denotes menu items, buttons and application names.
Italic type face denotes references to other sections, and the names of the folders, menus,
programs, and files.
<Enter> type face denotes keyboard keys.
Warning information appears before the text it references and should not be ignored
as the content may prevent damage to the device.
CAUTIONS APPEAR BEFORE THE TEXT IT REFERENCES, SIMILAR TO NOTES
AND WARNINGS. CAUTIONS, HOWEVER, APPEAR IN CAPITAL LETTERS AND
CONTAIN VITAL HEALTH AND SAFETY INFORMATION.
Indicates information that is important to know for the proper completion of a
procedure, choice of an option, or completing a task.
Highlights general or useful information and tips.
2
Etegro Fastor JS200 G3 JBOD
1.2. Safety Information
1.2.1. Important Safety Instructions
Read all caution and safety statements in this document before performing any of the instructions.
Warnings
Heed safety instructions: Before working with the server, whether using this manual or any other
resource as a reference, pay close attention to the safety instructions. Adhere to the assembly
instructions in this manual to ensure and maintain compliance with existing product certifications
and approvals. Use only the described, regulated components specified in this manual. Use of
other products / components will void the UL listing and other regulatory approvals of the product
and will most likely result in non-compliance with product regulations in the region(s) in which the
product is sold.
System power on/off: The power button DOES NOT turn off the system AC power. To remove
power from system, you must unplug the AC power cord from the wall outlet. Make sure the AC
power cord is unplugged before opening the chassis, adding, or removing any components.
Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on
power, telephone, and communication cables. Turn off the server and disconnect the power cord,
telecommunications systems, networks, and modems attached to the server before opening it.
Otherwise, personal injury or equipment damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage drives, boards, and other
parts. We recommend that you perform all procedures in this chapter only at an ESD workstation.
If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached
to chassis ground any unpainted metal surface on the server when handling parts.
ESD and handling boards: Always handle boards carefully. They can be extremely sensitive to
electrostatic discharge (ESD). Hold boards only by their edges. After removing a board from its
protective wrapper or from the server, place the board component side up on a grounded, static
free surface. Use a conductive foam pad if available but not the board wrapper. Do not slide board
over any surface.
3
Etegro Fastor JS200 G3 JBOD
1.3. Disclaimer
The information in this document is subject to change without notice. The manufacturer makes
no representations or warranties with respect to the contents hereof and specifically disclaims
any implied warranties of merchantability or fitness for any particular purpose. Furthermore, the
manufacturer reserves the right to revise this publication and to make changes from time to time in
the content hereof without obligation of the manufacturer to notify any person of such revision or
changes.
For the latest information and updates please refer to www.etegro.com
All the illustrations in this technical guide are for reference only and are subject to change without
prior notice.
4
Chapter 2. About JBOD
5
About JBOD
2.1. Introduction
This manual is written for system technicians who are responsible for troubleshooting, upgrading,
and repairing the JBOD chassis. This document provides an overview of the hardware features of
the system, management information, and instructions on how to add and replace components of
the JBOD.
For the latest version of this manual, see www.etegro.com.
6
About JBOD
2.2. System Features
Table 2.1. JS200 G3 Specifications
Hardware Features:
Enclosure Form Factor
4U Rackmount
HDD Support
(24) 6Gb/s 3.5" SASII and SATAII Hot-Swap HDDs
Host Interface/ per
controller
(3) 6Gb/s mini-SAS ports
(1) RJ11 console port
(1) RJ45 management port
Expansion Support
Scalable up to 72 Disk Drives: support 2 sets JS200 G3 systems daisy
chain (total 3 sets of JS200 G3 systems)
Power supply
2x 760W redundant PSUs
Supported HBA Card
See QVL list at www.etegro.com
Hot-Swap and Redundancy
Controller Module
(2) Dual hot-swappable controller modules
Disk Drives
Hot-swap HDDs (24-bay)
Cooling Fans
Total 2+2 redundant in the system, 2 fans in each power supply
module
Power Supply
(2) 760W redundant power supplies, input requirements 88 - 264V AC
Physical Dimensions
Dimensions, mm (H x W
x D)
175 x 445 x 557
Weight
29.33kg
Environmental
Operating temperature
0°C to 40°C (32°F to 104°F)
Humidity
50% to 93% relative humidity
Altitude
40°C / 3200 Meter
Shock
31G@2.6ms [mailto:31G@2.6ms], half-sine shock
0.26Grms random vibration 5~350Hz
Vibration
FCC- for US and Canada
CE- for Europe
BSMI- for Taiwan
KCC- for Korea
EMI/EMC
Safety Regulations
UL/CUL - for U.S. with Canada/ UL60950-1
7
About JBOD
CB (by Demko)- IEC60950-1/ EN60950-1
BSMI- Taiwan/ CNS14336
Monitoring and Notification
LED Indicators
Power LED
System ID/ Status LED
HDD Active and ID/ Status LED
Management
Support SCSI Enclosure Service (SES-2), console port
8
About JBOD
2.3. Package content
The JS200 G3 box contains the following items:
• JS200 G3 Storage unit (1)
• Power cord (2)
• CD with user manual and drivers (1)
• Universal Rail Kit(1)
• 6/4 HDD Screws(96)
9
About JBOD
2.4. System requirements
• Servers with supported HBA/Raid adapter, refer to JS200 G3 support matrix reference for
complete listing of supported adapters.
• SFF-8088 to SFF-8088 SAS cable.
10
About JBOD
2.5. JS200 G3 Front View
Figure 2.1. System front view
The button at the front of JS200 G3 is only used for locating for JS200 G3 storage with
management software and it does not power on/off the system.
11
About JBOD
2.6. JS200 G3 (Dual SIM) Rear View
Figure 2.2. System rear view
Table 2.2. System Component Overview
1
PSU Module 1
2
PSU Module 2
3
Power Connectors
4
SIM board 1
5
SIM board 2
6
SIM1 SAS IN Connector
(SFF-8088)
7
SIM1 SAS OUT Connector
(SFF-8088)
8
SIM2 SAS IN Connector
(SFF-8088)
9
SIM2 SAS OUT Connector
(SFF-8088)
10
SIM1 NET MGT + Service port
11
SIM2 NET MGT + Service port
NET MGT ports are for FW upgrade. Service port is for manufactory use only.
12
About JBOD
2.7. JS200 G3 Rear LED Descriptions
Figure 2.3. System rear LED
Table 2.3. Rear LED function and behavior
No
Component
Color
Description
1
AC Power Status
Solid Green
PS is ON
Off
No AC Power
Off
Normal
Solid Amber
Cooling Fan Failure
Solid Green
Normal
Off
No DC Power
Off
No failure
Solid Amber
Power Supply Failure
Solid Green
Connected No activity
Blinking Green
Accessing SAS
OFF
Not connected
OFF
Normal
Solid Amber
Fault SAS
Green
SIM is ON
Blinking Green
SIM is booting
Solid Amber
Fault SIM
SIM Locate
Off
Normal
Blinking White
2
3
4
5
6
7
8
Cooling Fan Power Fault
DC Power Status
Power Supply Status
SAS Link Power
SAS Link Status
SIM Power
13
About JBOD
2.8. Disk Drives and Tray
Figure 2.4. HDD tray
1
HDD Tray
2
Optional Interposer for
SATA HDD
3
Disk Tray Handle
Figure 2.5. HDD tray front view
1
HDD Activity LED
2
HDD Status LED
3
Release button (Blue)
4
Disk Tray Handle
Table 2.4. HDD tray LED function and behavior
No
Component
Color
Description
1
HDD Activity LED
Solid Blue
HDD is ready
Blinking Blue
Spin up /Accessing
Blinking Green
Identify HDD
Solid Red
HDD fault
Blinking Orange
RAID Resilver/Rebuild
Solid Orange
Hot Spare
2
HDD status
14
About JBOD
Alternate Green/
Orange
15
Scrub/Consistency Check
Chapter 3. Install/Replace HDD
16
Install/Replace HDD
3.1. Before You Begin
It is not recommend mixing SAS and SATA HDD in the same JS200 G3 system. If you have to,
please use the following figures below to plan where you will be placing the disk drives.
These figures represent fully-loaded JS200 G3 system with HDD.
However, the same guidelines apply even if you are filling some of the HDD slots with blank disk
trays in the mix-ing HDD setting.
Figure 3.1. Recommended Disk Drive Configurations
Figure 3.2. Unsupported Disk Drive Combinations
17
Install/Replace HDD
3.2. Follow these steps below to Install/
Replace HDD in the disk tray.
1. Remove HDD tray
a) Press the release button to right and open the disk tray handle.
b) Remove HDD carrier by pulling the disk tray handle out.
Figure 3.3. HDD carrier remove
2. Insert the HDD inside the tray and tighten the four 6/4 screws on the SATA/SAS disks.
Figure 3.4. Different drives
If using SATA HDD, please make sure having Interposer card installed on the back
of HDD tray. Otherwise there will be functionality problems.
3. Slide in the HD tray back in the disk slot and close the disk tray handle.
Figure 3.5. HDD carrier insert
18
Install/Replace HDD
4. Repeat Steps above if you wish to install more HDD into the JS200 G3 storage.
19
Chapter 4. Before You Begin
Confirm that there is adequate power at your facility to support the high-availability features of the
system. It is recommended to connect each power connector to separate power circuit.
If necessary refer to the documentations shipped with the 6Gb/s SAS HBA/RAID card for hardware
and driver installation instructions.
There are several types of SAS Cables in the market, make sure that you order the right one.
For JS200 G3, it all uses SFF-8088 to SFF-8088 SAS Cable when connecting JS200 G3 to host
and when daisy chain to another JS200 G3.
Figure 4.1. SAS cable
20
Chapter 5. Setting up JS200 G3
System
21
Setting up JS200 G3 System
5.1. Connection type 1(Single SIM)
This illustration shows one host with a HBA/RAID card connected to three JS200 G3 with single
SIM used.
Figure 5.1. One channel architecture
22
Setting up JS200 G3 System
5.2. Connection type 2(Dual SIM)
This illustration shows one host with a HBA/RAID card connected to three JS200 G3 with dual
SIM.
Not All HBA/RAID card support this type of connection please refers to JS200 G3
support matrix reference for complete listing of supported dual port 6Gb/s HBA/RAID
cards.
Figure 5.2. Dual channel architecture
23
Chapter 6. Power on the JS200 G3
1. Verify that all connections are correct.
2. Turn on both circuit breakers on cabinet.
3. Make sure that power-on LED on all JS200 G3 are steady blue.
4. Power on the server lastly.
Please make sure power on all JS200 G3 first before the server.
24
Chapter 7. Management guide
25
Management guide
7.1. Connect by console
Please prepare the following items:
• RJ45 network cable
• Windows machine with Telnet Client like Ayera TeraTerm Pro Web 3.1.3
URL of the download: http://ayera.com/teraterm/ttpro313.zip
Login Password : jbodstorage
1. Select COM port
2. Set serial port
26
Management guide
3. Use commands "dhcp" and "ip" to set network
"dhcp disable" to disable dhcp.
"ip 192.168.36.1" set ip=192.168.36.1
"ip 192.168.36.1 255.255.0.0" set ip=192.168.36.1, mask=255.255.0.0
27
Management guide
28
Management guide
7.2. Connect by network
Select TCP/IP and telnet:
JBOD provides a basic command line interface (CLI) as an alternative for users to configure their
JBOD. In order to use the CLI, users can use the UART or Ethernet port to communicate with
JBOD. In host side, user can use a terminal program or telnet/SSH application to communicate
with JBOD. In UART port, the baud rate should be set 115200bps. In Ethernet port, the speed can
be 10M or 100M. Before entering CLI, user needs to enter the password.
Table 7.1. General CLI
Command Description
Command format
ver
Show
version
sas_addr
Set/Get SAS address
sas_addr disks
<base_addr>
Show Disk status
disks
port
Show all SAS port status
port
err_cnt
Show
all phys
error
count
err_cnt
err_clr
Clear all phys error count
err_clr
reboot
Reboot SIM
reboot
ver
29
Management guide
enable
Enable FRU
enable <disk #/ps0/
ps1/peer/up/down>
disable
Disable
FRU
disable <disk #/ps0/ps1/peer/
up/down>
reset
Reset FRU
reset
who
<disk #/
ps0/ps1/
peer>
Show Mastership
who
date
Set/Show date
date <YEAR>
<MON> <DATE>
<HR> <MIN>
<SEC>
status
Show
System
FRU/
state
status
status
rpm
Set/Get FAN RPM
rpm
<1/2/3>
syslog
Clear/Get System
log
syslog <clr>
sda_show Show SDA count
sda_show
i2c
Show I2c i2c help
help
Show I2C device ID
i2c dev
I2C reset
i2c reset <all/devID>
I2C
device
read
i2c rd devID register
I2C device write
i2c wr
devID
register
value
Dump IIC device content
i2c dump <devID/
all>
eep_rd
Read EEPROM data
eep_rd <sim/peer/
mid/ps0/ps1>
zoning
Show/Toggle physical presence zoning <pp/help>
ip Show/Set
IP
ip ip_addr net_mask
address, gateway_addr and Default
Net Mask Gateway address
dhcp
Show/Set DHCP on/off
dhcp
fru
<enable/
disable>
Access FRU ID
fru <print/setssn/setppn/sync>
quit
quit
exit
Exit CLI interface
30
Management guide
7.3. Firmware upgrade guide
• Stop all IO to JS200 G3 before upgrade
1. Connect RJ45 network cable from Windows machine to JS200 G3 SIM1 NET MGT port
2. Run Tera Term and connect to 169.254.144.1 by Telnet (preparation procedure described
above)
3. Console prompt will show up and type “jobstorage” to enter protected Service Console
31
Management guide
4. Type “fdl 2 0 y” to upgrade the FW
5. Click File→Transfer→XMODEM→Send to transfer the FW
6. Select the FW file
32
Management guide
7. Transfer in process
8. Upgrade completed
33
Management guide
9. Reset JS200 G3 and use “ver” to make sure the FW has been upgraded successfully.
10.Please connect RJ45 network cable to SIM 2 NET MGT port and repeat step 3 to 10 to
upgrade SIM2
34