Signal
Signal Relays
AXICOM
D2n* Relay V23105
n
n
n
n
n
n
Standard DIL relay
Dimensions 20x10x11mm (.795x.394x.433”)
Switching and continous current 3A
2 form C contacts (2 CO, 2 changeover contacts)
Immersion cleanable
Four different coil sensitivities, 150mW, 200mW, 400mW, >500mW
Typical applications
Communications equipment, office equipment, measurement and control
equipment, entertainment electronics, medical equipment, consumer
electronics.
Z
Approvals
UL61810-1 (former UL508) No. 214025
Technical data of approved types on request
Contact Data
Contact arrangement
2 form C (CO)
Max. switching voltage
220VDC, 250VAC
Rated current
3A
Limiting continuous current, 85°C
3A
Contact material
AgNi, gold-covered
Min. recommended contact load
10mA at 20mV
Minimum switching voltage
100μV
Initial contact resistance <100mΩ at 10mA, 20mV
Frequency of operation without load
max. 50 operations/s
Operate / release time max.
6ms/4ms
Bounce time max.
5 ms
Electrical endurance
at 230VAC/0.5A
typ. 3x105 operations
at 6VDC/0.1A
typ. 2x106 operations
at 30VDC/1A
typ. 5x105 operations
at 30VDC/2A
typ. 1x105 operations
UL contact ratings
60 VDC, 0.3 A
30 VDC, 1 A
24 VDC, 1.25 A
42.4 V peak, 50/60 Hz, 0.5 A
42.4 V peak, 50/60 Hz, 1 A
(2 NO/NC contacts provided)
Mechanical endurance
typ. 10x106 operations
Coil Data
Magnetic system
Coil voltage range
Max. coil temperature
Thermal resistance
neutral
3 to 48VDC
85 °C
< 85K/W
Coil versions, monostable
Coil
Rated
Operate Limiting Release
Coil
Rated coil
code
voltage
voltage
Voltage
voltage resistance power
VDC
VDCmin. VDCmax. VDCmin. Ω±10%
mW
150mW coil power
001
5
4.0
11.7
0.25
167
150
002
6
4.8
14.0
0.30
240
150
006
9
7.2
21.0
0.45
540
150
003
12
9.6
28.0
0.60
960
150
005
24
19.2
56.0
1.20
3840
150
200mW coil power
308
3
2.1
6.1
0.15
45
200
301
5
3.5
10.1
0.25
125
200
302
6
4.2
12.2
0.30
180
200
306
9
6.3
18.2
0.45
405
200
303
12
8.4
24.3
0.60
720
200
305
24
16.8
48.6
1.20
2880
200
307
48
33.6
97.2
2.40
11520
200
400mW coil power
401
5
3.5
7.2
0.25
62
400
402
6
4.2
8.6
0.30
90
400
406
9
6.3
12.9
0.42
203
400
403
12
8.4
17.2
0.60
360
400
405
24
16.8
34.3
1.20
1440
400
407
48
33.6
68.6
2.40
5760
400
>500mW coil power
501
5
3.5
6.1
0.25
36
695
502
6
4.2
7.3
0.30
70
515
506
9
6.3
10.9
0.45
140
580
503
12
8.4
14.5
0.60
280
515
505
24
16.8
29.1
1.20
1050
550
507
48
33.6
58.1
2.40
4000
575
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Other coil voltages on request.
Coil Data (continued)
06-2022, Rev. 0622
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
1
Signal
Signal Relays
AXICOM
AXICOM
Telecom-, Signal and RF Relays
108-98007 Rev A
D2n V23105
RelayV23105 (Continued)
D2n* Relay
Coil Operating Range
Unom
Umax
Coil Data (continued)
Coil operative range
graphs
3.0
2.6
2.0
1.8
1.6
AXICOM
1.4
Telecom-, Signal and RF Relays
1.2
108-98007 Rev A
Unom. nominal coil voltage
1.0
D2n V23105 Relay
0.8
V23105 Relay
2.6
0.4
Coil Operating Range
0.2
0.0
-30
-20
-10
0
10
3.0
Uop. min.
Urel. min.
90
Umax. at400
0400
AmW
mW coil
Umax. at 2 x 1 A
max. at 0 A
UUmax.
at 2 x 2 A
Umax. at 2 x 1 A
UUmax.
at 0 A
max. at 2 x 2 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
2.2
2.4
2.6
2.0
2.2
2.4
1.82
2.2
1.6
1.8
2.0
1.4
1.6
1.8
1.2
1.4
1.6
1.0
1.2
1.4
108-98007 Rev A
Unom. nominal coil voltage
0.8
1.21
0.6
0.8
1.0
Unom. nominal coil voltage
Unom.
0.2
0.4
0.6
-20
-10
0
10
0.20
100 110 120
-30 -20 -10
0.03
-30
2.8
-20
-10
0
0
Uop. min.
Urel. min.
30
40
50
60
70
80
Ambient Temperature [°C]
20
30
40
50
60
70
80
Ambient
Temperature [°C]
20 30 40 50 60 70 80
Ambient Temperature [°C]
2.6
2.8
3.0
2.4
2.6
2.8
2.2
Voltage
[U/U
nom] nom]
Coil Coil
Voltage
nom] [U/U
Coil[U/U
Voltage
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
20
10
10
3.0
Umax. at 0400
AmW coil
400 mW
Umax. at 2 x 1 A
Umax. at 2 x 2 A
2.4
2.6
2
2.2
2.4
1.8
2.0
2.2
1.6
90
400 mW
Umax. at 0
550A
mW coil
550
mW
Umax. at 2 x 1 A
UUmax.
at
0
A
max. at 2 x 2 A
Umax. at 2 x 1 A
Umax. at 0 A
Umax. at 2 x 2 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
1.8
2.0
1.4
1.6
1.8
1.2
1.4
1.6
Unom. nominal coil voltage
1
1.2
1.4
0.8
1.0
1.2
0.6
0.8
1.0
0.20
0.4
120
0.0
0.2
Unom.
Uop. min.
Urel. min.
Uop. min.
U
rel. min.
Uop.
min.
Unom.
-30 -20 -10
-30
-20
-10
0
0
0.0
100 110 120
400 mW coil
400
mW
200 mW coil
200110
mW
100
120
400 mW coil
0.4
0.6
0.8
C]
Uop. min.
Urel. min.
Uop. min.
Urel. min.
Uop. min.
110 120
U100
rel. min.
90 100 110 120
90
0.2
0.4
0.6
Uop. min.
90 U
100
110
rel. min.
100 110 120
150 mW coil
150
mW
0.4
0.6
0.8
150 mW coil
150
mW
C]
80
200 mW coil
200
mW
0.0
0.2
0.4
-30
90
70
-30
-20
-10
0
10
10
20
30
40
50
60
70
80
Ambient Temperature [°C]
20
30
40
50
60
70
80
Ambient Temperature [°C]
10
20
30
40
50
60
70
80
U
90 100
110 120
rel. min.
2.6
2
2.4
Coil Voltage [U/Unom]
2.2
1.6
1.4
1.8
1.2
1.6
1
1.4
0.8
100 110 120
90
100 110 120
0.6
1.0
Unom.
1050V
1750V
1050V
> 109Ω
max. 2pF
max. 4pF
max. 2 pF
0.2/0.76mm
-39.0dB/-20.7dB
-0.02dB/-0.27dB
1.04/1.40
Uop. min.
Urel. min.
Other Data
0.2
Material compliance: EU RoHS/ELV,
China RoHS, REACH, Halogen content
Uop. min.
U100
rel. min.
0 10 20 30 40 50 60 refer
Product
Compliance Support Center at
70 80 to
90the
110 120
Ambient Temperature [°C]
www.te.com/customersupport/rohssupportcenter
0.0
Ambient10temperature
-40 to +85°C
-30 -20 -10 0
20 30 40 50 60 70 80 90 100 110 120
3.0
Temperature [°C]
CategoryAmbient
of environmental
protection
550 mW coil
550 mW
2.8
IEC 61810
RT III -wash tight
2.6
Vibration resistance (functional)
10g, 10 to 55Hz
Umax. at 0 A
2.4
Shock resistance (functional)
Umax. at 2 x 1 A
2.2
Umax. at 2 x 2 A
IEC 60068-2-27 (half sine)
10g
2.0
Shock resistance (destructive)
50g
1.8
Terminal type
PCB-THT
Unom1.6
=
Nominal coil voltage
Weight
max. 6g
1.4
Resistance
tooperative
soldering
heat
Umax. =
Upper
limit of the
range
of theTHT
coil voltage (limiting
1.2
IEC 60068-2-20
265°C/10s
voltage) when coils are continously energized
1.0 Unom.
Ultrasonic cleaning
not recommended
0.8
Packaging
unit
1000 pcs.
Uop. min.
= Lower
limit of the
operative range of
0.6
0
0.4
-30 -20 -10
0.2
0.6
the coil voltage (reliable operate voltage)
Uop. min.
Urel. min.
0.4
0.2 = Lower limit of the operative range of
Urel. min.
-30
the coil voltage (reliable release voltage)
-20
-10
0
10
20
30
40
50
60
70
80
90
100 110 120
Ambient Temperature [°C]
5 of 12
Terminal assignment
TOP view on component side of PCB
2.0
Unom =
1.8
Nominal coil voltage
1.4
1.2
Umax. =
Upper limit of the operative range of the coil voltage (limiting
voltage) when coils are continously energized
Unom.
1.0
0.6
0.0
-30
TOP
on(reliable
component
side of
the
coilview
voltage
operate voltage)
-10
0
10
20
30
40
50
60
70
PCB
Urel. min. = Lower limit of the operative range of
the coil voltage (reliable release voltage)
the coil voltage (reliable release voltage)
-20
Upper limit of the operative range of the coil voltage (limiting
PCB limit
layout
Uop. min. = Lower
of the operative range of
Uop. min.
Urel. min.
the coil voltage (reliable operate voltage)
0.4
Nominal coil voltage
voltage) when coils are continously energized
0.2 = Lower limit of the operative range of
Urel. min.
80
90
100 110 120
Ambient Temperature [°C]
All specifications subject to change. Consult Tyco Electronics for latest specifications.
06-2022, Rev. 0622
www.te.com
© 2015 Tyco Electronics Corporation,
a TE ConnectivityUnom
Ltd.=company.
Nominal coil voltage
Umax. =
5 of 12
5 of 12
o Electronics for latest specifications.
2
750Vrms
1250Vrms
750Vrms
1.2
0.4
0.8
100 110 120
Isolation at 100MHz/900MHz
Insertion loss at 100MHz/900MHz
Voltage standing wave ratio (VSWR)
Unom. nominal coil voltage
at 100MHz/900MHz
2.0
0.8
Uop. min. = Lower limit of the operative range of
Uop. min.
Urel. min.
RF Data
1.8
2.2
0.0
90
Umax. at 2 x 2 A
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
2.6
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
2.4
Umax. =
C]
1.4
2.8
Unom1.6
=
90
Initial dielectric strength
between open contacts
between contact and coil
108-98007 Rev A
1.2
between adjacent contacts
1 Unom. nominal coil voltage
Initial surge withstand voltage
0.8
between open contacts
0.6
Uop. min.
between contact and coil
0.4
Urel. min.
between
adjacent
contacts
0.2
Initial
insulation
resistance
at
500
VDC
0
-30 -20
-10 0 10 20 30 40 50 60 70 80 90 100 110 120
Capacitance
3
200 mW coil
Ambient
[°C]
between
openTemperature
contacts
200
mW
2.8
between contact and coil
2.6
3.0
between adjacent contacts
mW coil
Umax. at
0550AmW
550
2.4
2.8
Umax. at 2 x 1 A
Clearance/Creepage
1.6
3.0
Ambient Temperature [°C]
550 mW coil
550
mW
All specifications subject to change. Consult Tyco Electronics
for latest specifications.
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
80
1.8
2.2
Coil[U/U
Voltage
Coil Voltage
nom][U/Unom]
n V23105 Relay
80
60
Insulation Data
2
Coil Voltage [U/Unom]
-, Signal and RF Relays
80
50
2.6
2.8
3.0
Coil Voltage
[U/U
nom][U/U
Coil Coil
Voltage
[U/U
nom] nom]
Voltage
COM
90
40
2.4
2.6
2.8
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
80
30
2.83
150 mW coil
150
mW
C]
20
Ambient Temperature [°C]
Umax. at 2 x 2 A
2.2
Uop. min.
Urel. min.
0.6
Urel. min.
2.4
Coil Voltage [U/Unom]
, Signal and RF Relays
Coil Voltage [U/Unom]
2.2
Uop. min.
2.8
Umax. at 0 A
Umax. at 2 x 1 A
Umax. at 2 x 2 A
2.4
COM
3
150 mW coil
150
mW
2.8
Nominal coil voltage
Upper limit of the operative range of the coil voltage (limiting
voltage) when coils are continously energized
200 mW coil
200
Lower limit of the operative range
ofmW
the coil voltage (reliable operate voltage)
Lower limit of the operative
range of
Umax. at 0 A
the coil voltage (reliable release
Umax. atvoltage)
2x1A
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Upper limit of the operative range of the coil voltage (limiting
voltage) when coils are continously energized
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
Signal
Signal Relays
AXICOM
D2n* Relay V23105 (Continued)
Dimensions
Packing
Product code structure
Typical product code
V23105-A5
001
A201
*
Type
V23105-A5
D2n Series Signal Relay
Coil
Coil code: please refer to coil versions table
0xx
150 mW
4xx
400 mW
3xx
200 mW
5xx
550 mW
Contacts
A201 2 from C, 2 CO, AgNi-Au contacts
*
Version re-designed
Product code
Version
Coil power
Coil voltage
Part Number
V23105A5001A201*
V23105A5002A201*
V23105A5006A201*
V23105A5003A201*
V23105A5005A201*
V23105A5308A201*
V23105A5301A201*
V23105A5302A201*
V23105A5306A201*
V23105A5303A201*
V23105A5305A201*
V23105A5307A201*
V23105A5401A201*
V23105A5402A201*
V23105A5406A201*
V23105A5403A201*
V23105A5405A201*
V23105A5407A201*
V23105A5501A201*
V23105A5502A201*
V23105A5506A201*
V23105A5503A201*
V23105A5505A201*
V23105A5507A201*
V23105A5475A201*
V23105A5479A201*
V23105A5476A201*
V23105A5477A201*
V23105A5478A201*
AgNi+Au
contacts
150mW
5VDC
6VDC
9VDC
12VDC
24VDC
3VDC
5VDC
6VDC
9VDC
12VDC
24VDC
48VDC
5VDC
6VDC
9VDC
12VDC
24VDC
48VDC
5VDC
6VDC
9VDC
12VDC
24VDC
48VDC
5VDC
10VDC
12VDC
24VDC
48VDC
8-1393792-5
8-1393792-7
9-1393792-1
8-1393792-8
9-1393792-0
1393793-5
9-1393792-3
9-1393792-5
1393793-2
9-1393792-7
9-1393792-9
1393793-3
1393793-6
1393793-7
1-1393793-0
1393793-8
1393793-9
1-1393793-1
1-1393793-6
1-1393793-8
2-1393793-3
1-1393793-9
2-1393793-1
2-1393793-4
1-1393793-2
3-1393794-0
1-1393793-3
1-1393793-4
1-1393793-5
06-2022, Rev. 0622
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company.
200mW
400mW
>500mW
BT 47 type
spec T4563C
(current tested)
Catalog and product specification according
to IEC 61810-1 and to be used only together
with the ‘Definitions’ section.
Catalog and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Catalog product data, ‘Definitions’ section,
application notes and all specifications are
subject to change.
3