MICONIC B Collective Control lKA,IKS Setting into Operation o f Lifts with Drive Typezt Single Speed Automatic LeveILing -: Dynatron 2 Novern ber 1981 Lift Controls MlCONlC B INVENTIO AG -NW/ Collective C0ntr0( 1KAI1 r KS .CA Settina into O m t i a - Gruppe 1-11 .ZOO 8149 TB M/U R 8 L I S T €01 - TA ai J 155101 E- -1 ,L OF CONTENTS 1 / . Page 1. AUXILIARY EQUIPMENT 2. TESTING & PREPARATIONS PRIOR TO SETTING INTO OPERATION 2.1 I n s t r u c t i o n f o r a s s e m b l i n g p r i n t s i n t o BGT BGT BGT BGT 16 16 25 25 Simplex Mu1 ti p1 ex Simplex Mu1 t i p 1 ex 2.2 Functional C o n f i g u r a t i o n o f t h e a d a p t e r p i n s i n BGT 2.3 Layout o f t h e p r i n t e d c i r c u i t boards 2.4 Socket t e r m i n a l s t r i p s f o r t h e p r i n t e d c i r c u i t boards 2.5 Layout o f t h e s u p p l y b a r s 2.6 Position-numbers o f t h e p r i n t s i n BGT 2.7 Survey of t h e p r i n t s f o r MICONIC B c o l l e c t i v e ' c o n t r o l s r 3. ERECTION TEST TRAVEL 4. COMPLETION WORK 5. INSPECTION TRAVEL 6. NORMAL TRAVEL 7. 6.1 P o s i t i o n and f u n c t i o n o f t h e p o t e n t i o m e t e r s on t h e MICONIC p r i n t s 6.2 F i n a l work and f i r s t normal t r a v e l 6.3 Gray-Code l a y o u t APPENDIX: - - P r i n t c o n n e c t i o n d i agrarns I n s t r u c t i o n f o r m a g n e t i c b r a k e adjustment Technical C a t a l o g u e s h e e t s f o r ; h a f t i n f o r m a t i o n LED F u n c t i o n a l i n d i c a t i o n s on . p r o c e s s o r p r i n t P E 80 * ) BGT = Bay compartment f o r t h e p r i n t s C Lift-Controls MICONIC B INVENTIO AG derung NW v l sc-c Coilective Conk01 1KAAKS Setting intu Operation E + FA Gruppe 1-1 1 .200 8149 TB M/U R8 1. EBI-TA M* J 1551O"l E ' *end .Index ( S*,,. 2/ 25 . AUXILIARY EQUIPMENT - A Universal measurement instrument t e s t buzzer - Erection-travel print MFV 5 - Field wiring diagram (e.g. Unigor 3 ) o r an e l e c t r i c a l Attention : MICONIC B p r i n t s a r e t o be t r e a t e d according hand1 ing p r i n t s wi t h MOS-modul es t o the i n s t r u c t i o n s f o r . In p a r t i c u l a r take care of the following: - Never plug the p r i n t s i n t o the multiple pin s t r i p nor pull them out of i t as long as the main switch JH i s closed. - Persons must undergo s t a t i c discharging before touching p r i n t s (by touching e a r t h , e.g. control l e r frame). - Only s p e c i a l l y instructed personnel a r e a1 lowed to make e l e c t r i c a l measurements on p r i n t s . - The p r i n t s t h a t a r e not in use (plugged-in) s h a l l always be kept in the a n t i s t a t i c package in which they have been supplied. d 2. TESTING & PREPARATIONS PRIOR TO SETTING INTO OPERATION - Switch off the main switch JH, as well as. the power supply u n i t f o r 80V and 22V. .c - - Q Prints must not be plugged into the multipole pin s t r i p s of the bay compartment - iP!,p (BGT). The e l e c t r i c a l i n s t a l l a t i o n must have been completed. (Provide the , ? * U L; jumpers needed in the MR and on c a r top f o r the terminals of the O K R ) . E. 1:s: 2;; z - 0 I -; 3 - c ::;:E v- 0 ! c 'of 2 :a.: € - " 8 ) - !Zfg . ':a:- " _ ;> 2 2 . 9;;;I :p: ;; t i €c'-C .= - 2 .z C a 1 Check t h a t the screws in the terminals a r e a l l t i g h t , as well as the connections t o contactors, r e l a y s , e t c . SQ.- Swing o u t the bay compartment BGT. (Unscrew the two o u t e r screws of the bay compartment). - Make a visual check of the c,onnection pins on the p r i n t edge connectors. The connection pins must not contact each other and thus cause conductive connections among themselves. Further take care t h a t the supply bars a r e properly clamped and a r e lined u p horizontally with clearance. INVEKTIO AG I - TA J 155101 E EBI Lift Controls MlCONlC B m i l ? u w /Sch.l. Gruppe 1-11.200 8149 TB M/U R8 . Collective Controt l M K S Setting into O m t i o n E FA + *.na.-lna.. ( SW. 3/25 - Make the fol l owing resi stance measurements whereby the resistance value ) : (Attention: Switch off the power supply must be i n f i n i t e l y high ( unit) . . On a l l the supply'bars t o connection M01. . From terminal P3 t o a l l the connection pins of the cross-sectional adaptor. Adaptors a r e multiple pin s t r i p s (bearing no p r i n t s ) i n the bay compartment. They serve f o r adapting normal-wrap to miniwrap. The positions of these adaptors d i f f e r from i n s t a l l a t i o n t o i n s t a l l a t i o n . The allocation of the pins and the positions of the adaptors are shown on the next following pages. - Interrupt connection PE t o M01. Interconnect the ohmmeter: The instrument shall indicate a value of > 20 k n u p t o i n f i n i t e value ( CO ) . Thereafter remove the o h m e t e r and replace the connections. - Connect 80V, disconnect 22V, by means of the 2 c i r c u i t breakers on power supply unit NGE. - Switch on the main switches JH and JTHS. Measure the voltage between M01 and the adaptor on print SF 83: A11 the connection pins must be f r e e of a1 ternating o r d i r e c t v01 tage, Positions of the adaptor of p r i n t SF 83: see page 9/25 and the fol lowing, o r page 8/25 upper section. -, 2.1 Reconnect 22V by means of the c i r c u i t breaker on power supply u n i t NGE. Switch off JH. Instruction f o r Assembling P r i n t s i n t o Bay Compartments BGT 16 and BGT 25 - The layout sketches on pages 4 7 show the max. print assembly into the bay compartments BGT 16 and BGT 25. Interchanging of the p r i n t s by mistake i s prevented by providing them w i t h code s t r i p s . On assembling the prints i n t o the bay'compartment, take care t h a t a l l the prints f i t t i g h t l y the multiple pin s t r i p s . I f Lif* Controls MlCONlC B INVENTIO AG ~ U b r r w S, c h r a Collective Control lKAllKS Setting into Operation E + FA G r u p p e 1-1 1 .ZOO 8149 TB M/U R8 * J 155101 E . €01-TA .., 1 .,,, 1 S..,. 4 1 25. Adapter I I Interference Suppression p r i n t - 2 I Processor print -- rr\ C a l l Memory p r i n t a W l C a l l Memory p r i n t [ 1 T -- C a l l Memory p r i n t U W 2 I W - [ C a l l Memory p r i n t ]-I U c3 C a l l Memory p r i n t - a I I W U CD U a r c C a l l Memory p r i n t 1- Signal p r i n t 5 3 3 voltage Supply p r i n t 5Amp1 if i e r p r i n t > INVENT10 AG m.rrMV, Lift Controls MlCONiC B -I Collective Control lKAllKS Setting intu Operation E + FA G r u p ~ e1 - 1 1 -200 8149 TB M/U R8 Amno.-ro~~ - U - rO - 1 1 I W U ~3 G Z - 1 U - W I - ro 1 L 7 W U J J I Call Memory p r i n t I l Call Memory - I Lprinr U - l ! I W U U Call Memory p r i n t r r Call Memory W a I1 I m F-l I 9 U 1 C.- ! print C1 6/25 1 1 I I Cal l Memory W U In10 I Call Memory p r i n t 9 b t 9 W U - TA a' J 155101 E E01 C O Y L I I J Call Memory p r i n t 1 -- Adapter V) 0 I a W - Q P r o c e s s o r ~ rn it CO Call Memory p r i n t S Call Memory p r i n t 1 l l I CO W U c' CD - CO I r 1 Call Memory p r i n t 5 r .- m > 1 Call Memory p r i n t 1 r 1 M Signal p r i n t 51. m % I Y m "7 V o l t a g e Supply p r i n t . m V n l taae m S U O DY ~ m i n t C a l l Memory p r i n t W U L3 - Call Y ; r y 9 print W U , P\' C 0 Interface print I I C m X N - Processor p r i n t I 0 m 9 I 'l W Interference Suppression p r i n t I R CO 1 I Q\ Adapter 1 C a l l Memory p r i n t ' 5) I I W W U b Signal p r i n t 1 I m > U? Vol t a g e S u p p l y p r i n t l I I Amp1 i f i e r p r i n t > m INVENT10 AG newt - JA e"; J 155101 E EBI Lift Controls MICONIC B -X Collective Control ~KMKS Setting infu O p t i o n E+FA Gruppe 1-1 1 .ZOO 8149 TB M/U R8 ~n y C . * - 9 W U U Vol tagc Supply p r i n t l Cc 1 I 1 Cc m 1 1 I I Call Memory I pI r i n t L 1 J I I Call Memory p r i n t 5 , J Call Memory 9 m C W C U W U cu o I l U W N c Call Memory f r i n t t L C W CD N " " U - 9 Q 3 Call Memory p r i n t 1 - 1 W U U ' ~.nQ-lnQ.. o . -- I 9 Call Memory e r i n t .. i I 1 Call Memory p1 r i n t - m h - 0 7 ..a LY U zc ED W a 0 m L I l W a m .m 1 1 - Processor p r i n t l l 3 Processor p r i n t I -P? C 1 1 Interference Sup - Call Memory p r i n t I I W U W I W U 1 I m 9 rD - 9 - Interface p r i n t p~ X W 0 Call Memory p r i n t I 9 0 C Q\ Call Memory C W .U - 9 Q) Call Memory print c3 L W U z > h 1 I Adapter Sianal p r i n t 51 rC\ Voltage Supply p r i n t In Cu 1 - 1 c-W m W > J Amp1 i f i e r p r i n t 1 I * - . . l s w 7 / 25 L c. . Lift Controls MlCONlC B INVENTIO AG rung m.rp.rlw - -- -- f - derung %-I ~ o l l e c i v econtrol IWIKS Setling into Opemtion E+FA Gruppe 1-11.200 8149 TB M / U RB rrna -mac. Functional C o n f i g u r a t i o n o f the Adapter Pins i n BGT possible positions of the a d a p t e r (dependent on t h e t y p e o f BGT and t h e assemb l age- v a r i a n t ) B 15 B 8 B 13 B 11 . possible positions o f t h e a d a p t e r (dependent on t h e t y p e of 8GT and t h e assembl age-vari a n t ) z 2 I b 4 d z 4 6 b 6 z 8 b 8' d 8 z 10 b 10 d 10 provided f o r check of p r i n t c o n n e c t i o n CNFI-E/=* CNF1-D CNF1-B CNF1-A JSPZS 20 JSPZS JBF b 2 d 18 z 20 b 20 d 20 z 22 b 22 d 22 z 24 b 24 d 24 z 26 b 26 DT-S ORE-U DRE-D JRV/JTTC d z b d z 2 4 4 4 6 CNF2-A CNF2-B CNF2-C CNF2-0 b 6 CNF2-E d 6 d 26 KET-0 z 12 JNFF z 28 KBR-D b 12 d 12 z 14 JNO DC-Z/IDC-Z DLI-D/I 2STOPS b 28 b 14 KFL d 14 z16 b 16 d 16 KSKB20 * IFEST** IENO-HH M01 or d 28 z 30 b 30 d 30 z 32 b 32 d 32 DDFLI** DLI-U/HAND OP. IRL ***on PO i f t h e r e i s no advance door o p e n i n g RLI/IKA DT20-0 KSE TRVl/KNR-U TRVZ. RKU ET**' TRT/ I RS IUET KRB F RKBI/SF. RTS/ JSP' z 8 b a 8 z 10 b 10 KB KKB / KF K HH- E IQ69 RRE-A HH-B HH- C HH- D d RAB IRBR z 12 KCS-4 b 12 KBR-U d 12 KCS-0 d 14 HH-A d 30 z16 b 16 z32 b 32 d 16 B 16 6 8 SH1 b 18 KL-M KL-V KSKB KET20-0 KET-S KET20-S KTZ KTZ20 ~ c * #W c 25 KBl/IZYD/ZWA d 32 r INVENT10 AG n 4 l r N w l fckl Gruppe 1-1 1 .200 8149 TB M/U R8 1' -- -hAlCONiC B Lift Controls Co[\ectivc rnnhnl 1KA 11KC Sethng into 0paf.--- - - TA J 155101 E €01 \ 2.3 Layout o f t h e P r i n t e d C i r c u i t Boards The p r i n t e d c i r c u i t boards a r e assembled i n a bay compartment. Exampl e: BGT 16 Two types o f bay compartments are used i n dependence on the number of p r i n t s requi r e d : 1. Bay compartment BGT 16 2. Ba'y compartment BGT 25 INVENT10 AG n.rp.lr NW, km. Gruppe 1-1 I.ZOO 8149 TB M/U R8 2.4 '- ,gu: ,..": -a=;= z 0 0 " " - Collective Control IKAllKS Setting into Operation E + FA ;X-: ir a 3 :- :-: :G g; Socket terminal strips in use: i: : a e ,. .P' - a UU 2z 8: * d G z c C& 5 #-. C 0 - -- - - ;2 I0 E:: 0 : :z >=. 0 - - D c" 3 , :? 3 a g z :2 Awe -1nd.a 1 t.ll. i n d i r e c t plug connection. The connection of the wires t o the socket terminal s t r i p i s made in wire-wrap technique. The voltage supply i s led t o the p r i n t s via supply bars. Y erung Connection pins f o r Connection pins f o r internal p r i n t t o p r i n t incoming and outgoing wiring conductors 3 J 155101 E Socket Terminal S t r i p s f o r the Printed C i r c u i t Boards 1 i: €01-TA The printed c i r c u i t boards a r e connected t o the control c i r c u i t by an -:c Lift Controls MlCONlC B 1 0/2 . 2.5 Layout of the Supply Bars (Bay-Reverse Side) . .- ---.-;?a . . l L .. _ . . I I' 1 ' 1 1 1 1 ! I! l!! Ill Ill I!! (I/ I . lit Ill Ill I * ' I l l I l l 111 . 2 , . . . .-- Pin 2..-VD0 J ... I 11 l II Plug A - .-. -.. . - - .. P. .-.--.p - .-. ... Ill .. . C.. 3 I .l .l . -. -*.*a.- I t I L 1 ' I .. 7 + ...VCC 32 ...VSS P i n 26 Pin Pin 2...PO? Plug B Pin 30. ..M01 Pin 32.. .M01 v~~ = 12 V ( E l e c t r o n i c ) v ~ =c 5 "ss = . V (Electronic) 0 V (Electronic) 2.6 Posi tion-Numbers o f t h e P r i n t s (Bay-Front S i d e ) Bay compartment BGT 16 Bay compartment BGT 25 1 Place No. I Lift Controls MlCONlC B : INVENTIO AG -NW/ M. Gruppe 1-1 1 .ZOO 8149 TB M/U RE 2.7 Co(1ective Control 1KAIlKS Setting into O p t i o n E + FA EBI - TA 'M, J 155101 E '*and.-moan 1 snc* 13/ 25 Survey of the Prints f o r MICONIC B Collective Control S Electronic prints The following prints are used f o r MICONIC B collective controls: Supply p r i n t Call memory p r i n t 8NG 125. MA GCE 16 Power supply u n i t of the bay Memory car- & landing c a l l s Interference suppression print Processor print- - - - - - . Ampl i f i e r p r i n t Signal p r i n t Signal p r i n t SF 83 Sigrial former PE 80 V € 22 WV 31 WVV 31 Interface p r i n t AEX 81 .. .. Processor simple Amp1 i f i e r Travel continuation presel ection Travel ..continuation preselecti on amp1 i f i e r Adaption, E1 ectronic Central section These printed c i r c u i t boards have the Double Europe Format 223 X l60 m. The above p r i n t designation i s extended by tno l e t t e r s , which are separated from i t by period. The f i r s t l e t t e r indicates the s i z e of the p r i n t , here M = ~ o u b l eEumpe Format, t h e second l e t t e r the modification index: A = 0, B = 1 etc. Hence, the f u l l designation reads f o r instance: BNG 125. MA L. INVENT~OAG Collective coniro~1KA/IKS Sebng into Operation E FA Gruppe 1-1 1 .ZOO 8149 TB M/U R8 - EBI Lift Controls MlCONlC B Hrrg.mtuWI S e ) k l z ?-e J 155101 E ( s..c~1 4 / 2: *end.-lna.. + .. TA - ERECTION TEST TRAVEL 3. , the e l e c t r i c a l i n s t a l l a t i o n must Before performing the Erection Test Travel have been completed and the l i f t prepared f o r the f i n a l mechanical work. Further, a l l the. d e t a i l s of the instruction of para 2: "Testing and Preparations p r i o r t o s e t t i n g i n t o Operation" must have been gone through. - Switch off main switch JH. - Prints must not yet be plugged into the BGT (bay compartment). - A d j u s t the mechanical brake provisionally. - I n the case of automatic doors, overbridge the contact KTC conspicuously in the machine room, i f necessary (terminals No. 1108 - - 1116). I n the case of automatic doors, remove the wires from the t e m i n a l s No. 40L 40L2, 40L3 (automa t i c door drive di sconnected ) . - Switch the Inspection control switch JREC on t o p of tbe c a r t o "normal" position. - The s a f e t y c i r c u i t between the terminals P3 and 1190 i s closed (check with measurement instrument). - Check t h a t the s a f e t y c i r c u i t i s interrupted on operation of stop switch JHC. - Check function of t h e emergency l i m i t switch on the c a r roof ( i n t e r r u p t i o n of the s a f e t y c i rcui t ) . - Switch on main switch JH. - JTHS on the c o n t r o l l e r frame i s s t i l l closed. - Check d i r e c t i o n a l r o t a t i o n of MH, MV and brake release (change motor connections, i f necessary). - - Switch o f f again main switch JH.,I - Plug the p r i n t MFV 5. MA f o r Erection Test Travel i n t o the multiple pin - s t r i p of p r i n t BNG 1 2 5 . Caution: If the p r i n t f o r Erection Test Travel i s plugged i n , o t h e r p r i n t s must not be plugged i n t o the mu1 t i p l e pin s t r i p of the BGT. - l Switch on main switch JH. On operation of t h e red and white button on p r i n t MFV (Pos. A 3 - 831, the c a r m u s t travel downwards. On operation of the green and white b u t t o n on p r i n t M F V , the c a r must travel uowards. INVENTIO AG Collective Control 1 m K S Setting .nfo Opgatfion E + FA Gruppe 1-1 1 -200 8149 TB M/U RB 4. EBI Lift Controls MlCONlC B ~l,m*/sch.m. - TA J 1551o'l E rand -Inam b/z Sot(. COMPLETION WORK - Level the c a r with the entrance - Clean and lubricate the guides - Adjust the car- and s h a f t doors mechanically - I n s t a l l the s h a f t information equipment - Align the magnet switch block - Set the magnetic switches on stop 1 t o the relevant switching position as shown in the t a b l e below: i C Function of Magnetic Switch On L i f t s with Automatic Levelling without Over1appi ng Braking Oi stances On L i f t s with Automatig Level l i ng wi t h Overlapping Braking Oi stances - KSERE-U 797-746 closed c1 osed closed KS E 70 7 open open open KCS-0 651 closed closed closed KCS-1 652 open open open KCS-2 653 open open open open open 4 KCS-3 654 open KCS-4 655 open open open KUET 1259 closed closed closed closed closed closed closed K U E I' i 1260 KTZ/KTZ 20 789/90 KS 705 K0 R 703 I On Single Speed Lifts KBR-U 704 KBR-0 703 --- open -- -- -- -- closed --- --- closed closed The swi tchi ng posi t i on can be measured w i t h the measurement instrument ( r e s i s t a n c e meaiurement), o r with the t e s t buzzer a t the terminals of the OKR o r the c o n t r o l l e r c a b i n e t , providing the i n s t a l l a t i o n i s switched off and the p r i n t s a r e pulled o u t . - n e w / Gruppe 1-1 1 .200 8149 TB M/U RB Collective Control 1KAI1KS Setting inb Operation E FA + J 155101 E **nd.-tne*s r -: c - Take :a? :i:L- 82;- - " a-. .: - 0 ; ; :z 0 : S*,. 1 5/2! care of the cables of the door l i g h t b a r r i e r (on automatic d o o r s ) , Check emergency l i m i t switch in e i t h e r direction on Erection Test Travel ( P r i n t MFV). . 2::- zz-2 ( i f t r a v e l l i n g with the c a r door f u l l y open. a- >pv: is €51 - T A L i f t Controls MlCONlC B INVEMIO AG - On i n s t a l l a t i o n s with E l e c t r i c a l Recall Operation, moving of the c a r can 0 0 =: g-; $ .;;G :. c f ;s - be i n i t i a t e d from the machine room by means of a special control s t a t i o n . - Test ?g?: Operation ( i f there i s no Electrical Recall Operation, move the c a r by S 2 , ;2:: S a'. --... hand winding). c", C the overtravel in e i t h e r direction by means of the E l e c t r i c a l Recall - If the Erection Test Travel from the machine room i s functioning properly, the f i r s t t r i p of the Erection Test Travel from the c a r roof may follow. 2 - Switch on the switch f o r - The Erection Test Travel Inspection travel JREC on c a r top. can now take place by pressing DRE-U resp. DRE-D (KSERE must be closed) . The Erection Test Travel from c a r t o p has p r i o r i t y over the Erection Test Travel from machine room. - Check'the function of the stop switch JHC. - I n s t a l l the cross arm of the s h a f t information f o r the magnet switch KSERE 1500 mm below the s h a f t c e i l i n g . - Test the l i m i t stop of the Erection Test Travel: Limitation above: by KSERE Limitation below: by emergency l i m i t switch - Examine a l l the contacts in the safety c i r c u i t . - In every case, examine t h a t a l l the connections on the c o n t r o l l e r frame a r e c o r r e c t , which a r e made on erection. The best way of performing such an examination i s t o take the connection pins out of the terminals and to ring them u p with the t e s t be1 l . - I t i s important t o check the connections of the " c a l l registered" lamps and the c a l l buttons on the car- and landing control s t a t i o n s , as wrong connections might cause s h o r t ci rcui t s . Subsequently, the f i n a l i n s t a l l a t i o n work can be completed. - TA J 155101 E EBI Lift Controls MICONIC B INVENTIOAG ckrp.r(Nw/tck. Collet tive Control 1WlKS Setting hh O p t i o n E FA Gruppe 1-11.200 8149 TB M/U RB ~m.9.-ua, + ( ~ . # 1 17/ 25 ' I C: INSPECTION TRAVEL (Formerly Maintenance Travel) 5. - Switch off main switch JH. - Set Inspection Travel switch JREC on c a r top t o *normal1' position. - Pull out Erection Test Travel p r i n t MFV (Pos. A3-83). - Plug i n p r i n t BNG 125 i n t o t h e positions A3-B3 of t h e bay compartment. - Connect the pin 03/62 with 83/4z on the p r i n t edge connector BNG 125 (print-plug checking f o r SF 83 and PE 80). This connection s h a l l be made provisionally by means of a laboratory cable and terminal clamp probe tips. - Switch off c i r c u i t breaker of power supply u n i t NGE 80V. Switch on c i r c u i t breaker of power supply unit NGE 22V. - Switch on main switch JK- - The following v01 t a g e measurements must be made ( i n t h i s respect c o n s u l t "Layout of t h e Supply Bars", page 11 of t h i s i n s t r u c t i o n ) . = 22V 2 20 % - Between P09 - bar (+) and BNG 03/20 d+z (-) + - - Between 12V - bar (+) and BNG 83/20 d+z ( - ) - Between 5V - bar - Between VSS - bar - Between M01 - bar - Between 12V - bar - Between 12V - bar = 12V (+) and BNG 03/20 d+z ( - ) = (+) and BNG 83/20 d+z ( - ) = (+) and BNG 83/20 d+z ( - ) = (+) and VSS (+) and M01 - bar - bar (-1 . (-1 5V OV - + c- 0,8V - 0,25V OV = 12V = 12V Switch off main switch JH. Remove the provisional connection from 03/62 t o B3/4z (Print-p1 ug checking). Attention: From now on t h e i n s t r u c t i o n of handling p r i n t s w i t h MOS-modules i s t o be observed ( s e e Instructions f o r Erection and Maintenance). - In the case of automatic doors No. 1108-1116). * - In t h e case of automatic doors * remove t h e bridging of KTC (Terminals re-connect the wires of t h e terminals No. 40L1, 40L2 and 40L3 (power operated door d r i v e ) . * Only i f t h e door d r i v e had been adjusted. - Plug i n cautiously a l l t h e p r i n t s i n the bay-compartment. - Switch on c i r c u i t breaker of power ,supply unit NGE 80. Switch on t h e evacuation t r a v e l switch i n the machine room ( E l e c t r i c a l recall operation). - - Switch on - t h e main switch JH (Light-emitt-ing diode indi'cator on PE 80, see Appendix page 25). In the case of automatic doors, check the rotational sense of MT. If e l e c t r i c a l r e c a l l operation control i s present, the l i f t can be operated from the machine room with t h i s f e a t u r e . C - INVENTIO AG m r l N w / 3Ch. Gruppe 1-1 1 .ZOO 8149 TB M/U R0 EBI-TA Lift. Controls MICONIC B Collective Confrol 1 U 1 K S Setting into Operation E + FA 1 J 15510'l E ,A . .~naes ( sstm - Switch on JREC on c a r roof. - I n s p e c t i o n t r a v e l can be made now by p r e s s i n g t h e i n s p e c t i o n b u t t o n s . 18/ 2! Check t h e l i m i t o f t h e i n s p e c t i o n t r a v e l a t t h e bottom. Limitation: a t level stop 1. 6. NORMAL TRAVEL 6.1 P o s i t i o n and Function o f t h e P o t e n t i o m e t e r s on t h e Miconic P r i n t s r 1 1 ( \ P R I N T PE 80 / P1 : ZK ON/OFF Time period m o n i t o r i n g on/off PZ: ZB P.3: ZFT ZKNO P4: ZK PS: ZKBI ZRL ~ 6 ZQZE : a p1 €3 p2 a C brake ( o n l y f o r Dynatron F i n a l Timer/moni t o r i n g m o n i t o r i n g ernergexy powe monitoring Time period m o n i t o r i n g eddy c u r r e n t brake ( o n l y f o r Dynatron) Time period autom. r e t u r n ( o n l y f o r Hydraul i c ) D i f f e r e n t i a t e d d o o r held-open time. The door held-open time i s e s t a b l i s h , by ZQZE and ZFF. P7: ZFF ZLC-A Time period s t a r t i n g r e l e a s e Time period c a r l i g h t o f f P8: ZW Time p e r i o d c o n t i n u a t i o n of t r a v e l P9: Zcd'A Time ' p e r i o d c o n t r 6 l e d ' adherance (not used). PRINT WV 31 ( o u t p u t = 1 , 2 Watt) P1 + P2 : Frequency of a r r i v a l gong P3 + P4 : Loudness l e v e l of a r r i v a l gong P3 P4 PRINT W 31 0 Time period Time period door open Time period SUPPIY Time period PRINT WVV 31 (Output = 5 Watt) P1 + P3 : Frequency of a r r i v a l gong P2' + P4 : Loudness l e v e l o f a r r i v a l gong r INVENTIO AG -NW/ Sdru Lift Controls MlCONlC B Gruppe 1-1 l .ZOO 8149 TB M/U R8 Collective Control 1MKS Setting -MOperation E+ FA 6.2 €01-TA J 155101 E ( Sw1*19/25 Awe.-md.. Final Work and f i r s t Normal Travel - Move t h e c a r t o l e v e l - 1 s t stop. Switch o f f main switch JH ( o r JTHS). Switch o f f i n s p e c t i o n c o n t r o l (JREC). - Initial adjustment o f .the time-lag elements on p r o c e s s o r p r i n t PE 80: ZK on/off = P1 = ZB ZFT/ZKNO ZK ZKB I /ZRL ZQZE = p2 = P3 = P4 = p5 = P6 ZFF/ZLC-A = P7 = 30% ZW Zcd ' A = p8 = = p9 = 304, 0% l e f t h a n d l i m i t s t o p = = = = = 0% l e f t h a n d limit s t o p 0% l e f t h a n d l imit s t o p 75% 100% r i g h t h a n d limit s t o p 0% l e f t h a n d l i m i t s t o p 0% l e f t h a n d l i m i t s t o p (S.imp1ex) -' - Switch on main s w i t c h JH ( o r JTHS) . - P o s i t i o n i n d i c a t o r on p r i n t SF 83 , i n d i c a t e s - . . . "1". A t t e n t i o n : I f p o s i t i o n i n d i c a t o r would i n d i c a t e E, then code 00000 c i r c u i t . Check c o n n e c t i o n s t o t h e magnetic s w i t c h e s KCS.. supply (Gray-Code) - the Green LED on p r i n t PE 80 i l l u m i n a t e s . - Red - . . and is i n LED i l l u m i n a t e s o n l y i f t h e door i s open. S t a r t f o r t h e f i r s t normal t r a v e l t o s t o p 2. Tip l i g h t l y terminal 102 w i t h t h e c a l l i n g plug ( c a r c a l l ). The c a l l i n d i c a t o r shows "2". The l i f t i s s t a r t i n g and s t o p s a t "2". Check the t r a v e l l i n g performance. -.I - Now, t h e p o s i t i o n i n d i c a t o r shows i'2". Repeat t h i s procedure f o r t h e f u r t h e r s t o p s by t i p p i n g a t t h e t e r m i n a l s 101 t o 1 0 0 d each time. Stop a t e v e r y l a n d i n g by means o f t h e c a r b u t t o n s . Adjust the mechanical b r a k e f i n a l l y ( t e s t i n g i t by emergency s t o p of t h e empty c a r going upwards). In t h i s r e s p e c t s e e K 601 358 f o r W54 K - W60 and K 600 298 f o r W 140. - Make a n a c c u r a t e l e v e l l i n g a d j u s t m e n t ; i n t h e c a s e of a u t o m a t i c l e v e l l i n g . by s h i f t i n g t h e KBR magnets; i n t h e c a s e o f automatic l e v e l l i n g with o v e r l a p p i n g braking d i s t a n c e s by s h i f t i n g t h e KBR-D resp. KBR-U magnets. - Adjust t h e time-lag elements f i n a l l y . ( f o r adjustment d a t a s e e the n e x t s h e e t ) . INVENT10 AG n.rg..lrrrw/ L i f t Controls MICONIC B Gruppe 1-1 1 .200 8149 TB M/U R8 Collective control 1KMKS Setting infu Operation E + FA - TA J 1551(Y E EBI ( s.11. 20/; *.no,-ma.. DATA FOR ADJUSTING THE TIME-LAG ELEMENTS : ."" a - ,Hv: v Y2: - Q - < U 3 z::" ? a : ;g:; ::m: * :, X2 TIME-LAG ELEMENT -:- G:-a ; 0 C 2::: 1 ADJUSTMENT BY p - p REFERENCE VALUEIADJUSTMENT RANGE ; . E l - 2 ; :Fw1. - ..d2; . _ V0* = 2 .- PI; cw: ZK o f f only l i m i t s t o p lefthand o r righthand (serves a s a s w i t c h ) P 2 ; cw: t i m i n g l o n g e r f o r Dynatron 2 o n l y u n t i l b r a k e d i s k i s a t s t a n d s t i l l and i s b e g i n n i n g t o t u r n backwards. . 0 , l s - 2s ( f o r FA = ' l i m i t s t o p ccw) Iv p W O " ";ca :5 - 8 21 Uk /P /& P3; cw: t i m i n g l o n g e r #p 56 1 *i)oon fi+ P4; cw: t i m i n g l o n g e r bfW-5 ~ , \ , , ~ ~ J l ( ~ ~ I ZKBI I P5; cw: t i m i n g l o n g e r nbGL, Q,A&LbWYr41 I ZRL ZQZE M 'Jpu I l s - L lra bh- bd_ p& l o n g e r t h a n ZFT i f no ZFT, t h e n l o n g e r t h a n ZQZE 9s - 6 0 s - P 6 ; cw: t i m i n g l o n g e r f o r Simplex = ccw l i m i t s t o p f o r Mu1 t i p l e x = a p p r o x . 2s 1 s - 20s f o r Simplex = a p p r o x . 5 s f o r Mu1 t i p1 ex = a p p r o x . 2s 0,5s - 1 0 s L Zcd ' A P8; cw: t i m i n g l o n g e r &&W a p p r o x . 3s I s - 10s P9; cw: t i m i n g l o n g e r ccw l i m i t s t o p , n o t u s e d 0,3s rung ZLC-A=8xZFF l ZW ZFF FA: ccw l i m i t s t o p f o r Dynatron: see " S e t t i n g i n t o S e r v i c e " p a r a . 16.4 0.1s 20s: only f o r Hydraulic (60s) 60s - 1500s P7; cw: t i m i n g l o n g e r + l -for PS; cw: t i m i n g l o n g e r @pL ZFFIZLC-A s h o r t e r t h a n ZK ( a p p r o x . 1 2 s ) l o n g e r t h a n ZQZE + ZFF 95 - 6 0 s - 10s JNVENTIOAG Lift Controls MlCONlC B -MW/ Gruppe 1-1 l ,200 8149 TB M/U 6.3 RB Collective Confrd W M S Setting 'nio Operation E + FA STOP LEVEL - 1 TA J 1551Ot E ~ma.4M.a Gra y-Code Layout ARRANGEMENT OF MAGNETS €B1 S.*. 2 1/ 25 lerung m.I(Nw/ -. Collective Control lWlKS Setting into Operation E + FA Gruppe 1-1 1 .200 8149 TB M/U R8 APPENDIX P r i n t Connection Diagrams P r i n t GCE 16.MA P r i n t VE 22.MB P r i n t WV 31 .MA P r i n t WVV 31 .MA P r i n t SF 83.MB F r i n t PE 80 .M8 .- - Erection t e s t t r a v e l c o n t r o l P r i n t BNG 125 P r i n t VCE 16.MA - TA J 155101 E I r . n 22/ 2 . €01 Lift Controls MICONIC B INVENTIO AG . INVENTIO AG -m/ sskrir Gruppe 1-1 1 .ZOO 8149 TB M/U R8' Lift Controls MlCONlC EBI B J 155101 E Coilective Control IWMS Setting inin Operation E + FA A ~ . ~ ~ . . I n s t r u c t i o n for magnetic brake adjustment I n s t r u c t i o n for s e t t i n g i n t o operation t h e geared machines: W54 S W57 Catalogue sheets K 601 358 D - TA page 3 . . .S - W60 ( W. 23/25 + deruna INVENTIO AG -NW/ Lift Controls MlCONlC B Sehr. Collective Control 1W1KS Setting into O p t i o n E + FA Gruppe 1-1 1 .ZOO 8149 TB M/U R8 €01 v - TA J 155101 E ( A.~Q-IW.. SWI. 25/2 LED Functional I n d i c a t i o n s on P r o c e s s o r P r i n t PE 80 Functions of t h e c o n t r o l a r e i n d i c a t e d on t h e p r o c e s s o r p r i n t by t h r e e l i g h t e m i t t i n g d i o d e s (LED). Processor P r i n t - L i f t Section Light-emi t t i n g d i o d e LFN green : i l l u m i n a t e d , i f c o n t r o l i s switched t o normal o p e r a t i o n . e x t i n g u i s h e d , i f c o n t r o l i s switched t o i n s p e c t i o n o p e r a t i o n and t h e supply v o l t a g e o f 22V is not a v a i l a b l e , - t h e c o n t a c t s on b r a k z magnet do n o t work i n t h e same s e n s e ( w i t h i n 250 ms) . flashing, - i f m o n i t o r i n g KSE responds (Car blocked i n t h e lower s h a f t e n d ) . Light-emi t t i n g d i o d e LT-0 red : i l l u m i n a t e d , i f d o o r s a r e opened. extinguished, if doors a r e closed ( s w i t c h i n g p o i n t through KET-S) flashing, . i f m o n i t o r i n g "door o v e r - b r i d g i n g " responds (KUET-range). I n t h i s i n s t a n c e , t h e green LED i s C 2 5g X:: C 5; O: z C&:?: sy ; ~ : ' 2 5 2 2 I switched o f f . ;; SE. ; . ' A . V E -G.: : ;zi f 3.J; 0 =:P? derung L i g h t - e m i t t i n g d i o d e LSPT-0 yellow: i l l u m i n a t e d , i f t h e c a r i s l e v e l l i n g - i n and t h e d o o r s remain c l o s e d , e . g . s t o p p i n g w i t h o u t responding t o a c a l l , c o r r e c t i o n t r a v e l , a u t o m a t i c r e t u r n t o t h e main f l o o r , d i s t r i b u t i o n through group c o n t r o l s . Keeps i l l u m i n a t e d t i l l ZW has timed o u t . .--